Rev. 05.25.11_#43
LPQ200-M Series
1 of 3
Embedded Power for
Business-Critical Continuity
LPQ200-M Series
200 Watts
Special Features
• MedicalandITEsafeties
• Activepowerfactorcorrection
• 3”x5”footprint
• Lessthan1Uhigh
• EN61000-3-2compliant
• Remotesense
• Powerfail
• Adjustableoutputs
• Built-inClassBEMIfilter
• Overvoltageprotection
• Overloadprotection
• Thermaloverloadprotection
• LPX200enclosurekitavailable
Total Power: 100-200Watts
Input Voltage: 90-264Vac
# of Outputs: Quad
Electrical Specifications
Safety
Input
Inputrange: 90-264Vac;120-300Vdc
Frequency: 47-63Hz
Inrushcurrent: 50Amax.,coldstart@25°C,230Vacinput
Efficiency: 84%typicalatfullload
EMI/RFI: FCCClassBconducted;CISPR22ClassBconducted;
EN55022ClassBconducted;VDE0878PT3ClassBconducted
Safetyground
leakagecurrent:
275uA@50/60Hz,264Vacinput
Output
Maximumpower: 100Wforconvection;200Wwith30CFMforcedair
Adjustmentrange: Alloutputs-20%,+10%,exceptforthe3.3Voutputwhichwillbe-15%,
+10%(LPQ201-M)
Hold-uptime: 16ms@200Wload,120Vacinput
Overloadprotection: Shortcircuitprotectiononalloutputs.V1,V2&V3overloadprotected@
110-160%.V4is150-250%aboverating
Overvoltageprotection: 30-50%abovenominaloutputonV1(andV2onLPQ202)
LogicalControl
Powerfailure: Activelowlogicsignalgoeshigh100-500msecaftermainoutput;itgoes
lowatleast6msecbeforelossofregulation
Remotesense: Compensatesfor0.5Vleaddropmin.Willoperatewithoutremotesense
connected.Reverseconnectionprotected.
• TUV 60950,60601-1
• UL 60950,60601-1
• CSA 60950,60601-1
• CB Certificate&report
• CE Mark(LVD)
Embedded Power for
Business-Critical Continuity
OrderingInformation
Model
Number
Output
Voltage
Minimum
Load
MaximumLoadwith
ConvectionCooling
MaximumLoadwith
30CFMForcedAir
Peak
Load Regulation2Ripple
P/P(PARD)3
LPQ201-M
+3.3V 0A 13A 18A 20A ±2% 50mV
+5V 0A 13A 18A 20A ±5% 50mV
+12V 0A 5A 9A 10A ±5% 120mV
-12V 0A 1A 2A 2.5A ±5% 120mV
LPQ202-M
+5V 0A 13A 18A 20A ±2% 50mV
+12V 0A 5A 9A 10A ±5% 120mV
+24V 0A 1.5A 3A 3.5A ±7% 240mV
-12V 0A 1A 2A 2.5A ±5% 120mV
1. Peakcurrentlasting<30secondswithamaximum10%dutycycle.
2. At25°Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings.
3. Peak-to-peakwith20mHzbandwidthand10µF(tantalumcapacitor)inparallelwitha0.1µFcapacitoratratedlinevoltageandloadranges.
Rev. 05.25.11_#43
LPQ200-M Series
2 of 3
Operatingtemperature: 0°to50°Cambientderateeachoutputas2.5%perdegreefrom50°to70°C.-20°C
start up
Storagetemperature: -40°Cto+85°C
Electromagnetic
susceptibility:
DesignedtomeetEN61000-4;
-2,-3,-4,-5,-6,-8,-11Level3
Humidity: Operating;non-condensing10%to90%RH,non-operating,non-condensing10-95%
Vibration: IEC68-2-6tothelevelsofIEC721-3-2
MTBFcalculated: 516,000hoursatfullloadand25°Cambientconditions.230Vacinput,Bellcore
EnvironmentalSpecifications
PinAssignments
ConnectorLPQ200-M
SK1 Pin1 Neutral
Pin3 Line
SK2 Pin1 V1OUT
Pin 2 V2OUT
Pin3 GNDOUT
Pin4 GNDOUT
Pin5 GNDOUT
Pin6 GNDOUT
Pin7 V3OUT
Pin 8 V4OUT
SK3 Pin1 +V1Remotesense
Pin 2 -V1Remotesense
Pin3 N/C
Pin4 N/C
Pin5 +Powerfail
Pin6 Common
Pin7 N/C
Pin 8 Common
Pin 9 +V2RemoteSense(LPQ201-Monly)
Pin10 -V2RemoteSense(LPQ201-Monly)
MatingConnectors
ACInput(SK1): Molex09-50-8031(connector)
PINS:08-52-0113
ACGround: Molex01-90020001
DCOutput(SK2): Terminalblock
WiresizebasedonCableAmpacity/AWG
ControlSignals
(SK3):
Molex90142-0010(USA)
PINS:90119-2110or
Amp:87977-3
PINS:87309-8
EmersonNetworkPowerConnectorKit#70-841-027,includesalloftheabove.
1. Specificationssubjecttochangewithoutnotice.
2. Alldimensionsininches(mm),toleranceis±0.02”(±0.5mm)
3. MountingholesMH1andMH2shouldbegroundedforEMIpurposes.
4. MountingholeMH1issafetygroundconnection.
5. Specificationsareforconvectionratingatfactorysettingsat115VACinput,25
°Cunlessotherwisestated.
6. Thispowersupplyrequiresmountingonmetal
standoffs0.20”(5m)inheight.
7. Warranty:2years
8. Weight:1.5lbs/0.68kg
Rev. 05.25.11_#43
LPQ200-M Series
3 of 3
Embedded Power for
Business-Critical Continuity
MechanicalDrawing
100W
Output Voltage
Adjust POTs
2.55 (64.8)
3.00 (76.2)
0.224 (5.7) (4X)
0.224 (5.7) (4X)
5.00 (127)
4.55 (115.6)
PIN - 5
PIN - 10
PIN - 1
PIN - 8
SK3
SK2
Ø4 (4X)
Mounting Hole
V4 Adjust POT
PIN - 1
Ground Tab
PIN - 3
SK1
0.06 (1.5) (2X)
0.472 (12) 1.32 (33.6) max
0.098 (2.5)
MH1 Safety Gnd
V1 Pot AdjV2 Pot Adj.
V3 Pot Adj
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
informationorforanyerrorsoromissions.
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksand
servicemarksofEmersonElectricCo.
©2011EmersonElectricCo.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCooling
Racks&IntegratedCabinets
Services
SurgeProtection
Emerson Network Power.
Thegloballeaderinenabling
business-criticalcontinuity.
ACPower
Connectivity
DCPower