INTEGRATED CIRCUITS DIVISION
IX2127
R03 www.ixysic.com 5
1.6 Electrical Characteristics
Unless otherwise specified, the test conditions are: VCC=VBS=12V; VCC, IN, FAULT, and Leakage voltages and
currents are referenced to COM; VB, HO, and CS voltages and currents are referenced to VS .
1.6.1 Power Supply Specifications
1.6.2 Gate Drive and Shutdown Specifications
* RGATE value must be 20 or greater.
1.6.3 Logic I/O Specifications
1.6.4 Thermal Specifications
Parameter Conditions Symbol Minimum Typical Maximum Units
Quiescent VCC Supply Current VIN=0V IQCC -280400
A
Quiescent VBS Supply Current VIN=0V IQBS - 500 1000
VBS UVLO Positive-Going Threshold -VBS_UV+ 6.8 7.7 8.6 V
VBS UVLO Negative-Going Threshold -VBS_UV- 6.3 7.2 8.1
Offset Supply Leakage Current VB=VS=600V ILKG --2
A
Parameter Conditions Symbol Minimum Typical Maximum Units
High Level Output Voltage, VB-VHO IHO=0A VOH --100
mV
Low Level Output Voltage, VHO IHO=0A VOL --100
Output Short Circuit Pulsed Current
VHO=0V, VIN=5V, PW<10s,
RGATE=20* (see Figure 1) IHO+ -200 -250 -
mA
VHO=12V, VIN=0V, PW<10s,
RGATE=20* (see Figure 1) IHO- 420 500 -
CS Input, Positive-Going Threshold VCC=9V to 12V VCS_TH+ 180 260 320 mV
“High” CS Bias Current VCS=3V ICS+ --1
A
VCS=0V ICS- ---1
Parameter Conditions Symbol Minimum Typical Maximum Units
Logic “1” Input Voltage VCC=9V to 12V VIH 3.0 - - V
Logic “0” Input Voltage VCC=9V to 12V VIL --0.8
Logic “1” Input Bias Current VIN=5V IIN+ -2.615
A
Logic “0” Input Bias Current VIN=0V IIN- ---1
FAULT On-Resistance - FLT, RON -72-
Parameter Conditions Symbol Minimum Typical Maximum Units
Thermal Resistance, Junction to Ambient:
8-Lead DIP -RJA
--125
°C/W
8-Lead SOIC --200