HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz POWER DETECTORS - SMT 8 Typical Applications Features The HMC602LP4(E) is ideal for IF and RF applications in: Wide Dynamic Range: up to 70 dB * Cellular/PCS/3G Fast: 8ns Output Response Time * WiMAX, WiBro, WLAN, Fixed Wireless & Radar Supply Voltage: +5V * Power Monitoring & Control Circuitry Power-Down Mode * Receiver Signal Strength Indication (RSSI) Excellent Stability over Temperature * Automatic Gain & Power Control Buffered Temperature Sensor Output High Accuracy: 1 dB with 60 dB Range Up To 6 GHz Compact 4x4mm Leadless SMT Package Functional Diagram General Description The HMC602LP4(E) Logarithmic Detector/Controller converts RF signals at its input, to a proportional DC voltage at its output. The HMC602LP4(E) employs a successive compression topology which delivers extremely high dynamic range and conversion accuracy over a wide input frequency range. As the input power is increased, successive amplifiers move into saturation one by one creating an accurate approximation of the logarithm function. The output of a series of square law detectors is summed, converted into voltage domain and buffered to drive the LOGOUT output. For detection mode, the LOGOUT pin is shorted to the VSET input, and will provide a nominal logarithmic slope of -25mV/ dB and an intercept of 12 dBm (19 dBm for 5.8 GHz). The HMC602LP4(E) can also be used in the controller mode where an external voltage is applied to the VSET pin, to create an AGC or APC feedback loop. Electrical Specifications, TA = +25C, EN= 5V, Vcc1, Vcc2, Vcc3= +5V [1] Typ. Typ. Typ. Typ. Typ. Typ. Typ. Typ. Typ. Typ. Units Input Frequency Parameter 50 100 900 1900 2200 3600 5800 7000 7500 8000 MHz 3 dB Dynamic Range 70 70 72 71 72 70 66 62 59 57 dB 3 dB Dynamic Range Center -30 -30 -30.5 -32.5 -33 -31 -25 -22 -22 -20.5 dBm 1 dB Dynamic Range 61 61 63 63 62 57 60 55 50 46 dB Output Slope -25.7 -25.7 -25.3 -25.0 -24.9 -24.8 -25.5 -27.5 -28.9 -30.2 mV/dB Output Intercept +13.2 +13.2 +13.4 +13.0 +12.4 +14.2 +21.3 +20.2 +19.2 +18.5 dBm Temperature Sensitivity @ -10 dBm Input [2] 12.3 11.2 11.4 11.6 12.5 14.7 16.9 24.6 27.7 33.0 mdB/C [1] Detector mode measurements; LOGOUT (Pin 15) is shorted to VSET (Pin 16). [2] Measured from TA = -40C to TA = +85C 8 - 22 For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz Electrical Specifications, (continued) Parameter Conditions Min. Typ. Max. Units LOGOUT Interface Output Voltage Range 0 Output Rise Time/Fall Time From 0% to 90% Vcc -1.0 V 7.5 / 8.1 ns 30 k VSET Interface Input Voltage Range Low Frequency Gain VSET to LOGOUT Open Loop Corner Frequency 0.25 to 1.35 V 56 dB 700 kHz Power Down (EN) Interface Voltage Range for Normal Mode Voltage Range for Powerdown Mode 0.8 x Vcc [1] Vcc [1] V 0 0.2 x Vcc [1] V Vcc [1]/2 Threshold Voltage V Power Supply (Vcc1, Vcc2, Vcc3) Operating Voltage Range 4.5 Supply Current in Normal Mode Supply Current in Power Down Mode 5.5 V 113 mA 1 mA [1] Vcc= Vcc1= Vcc2= Vcc3= +5V 8 POWER DETECTORS - SMT Input Impedance Test Conditions Parameter Condition Vcc1, Vcc2, Vcc3 +5V Input Zo - w/ 68 Term Resistor at INP 50 TA +25C Fin 900 MHz INN Port connected to ground through a 1000pF capacitor For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com 8 - 23 HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz LOGOUT Voltage & Error vs. Input Power, Fin = 50 MHz LOGOUT Voltage & Error vs. Input Power, Fin = 100 MHz 3 2.6 IDEAL 1 1.8 1 1.4 0 1.4 0 -1 ERR +25C ERR +85C ERR -40C 0.2 -70 -60 -50 -40 -30 -20 -10 LOGOUT (V) 1.8 1 -1 1 -2 0.6 -3 0.2 0 -70 -3 -60 -50 -40 -30 -20 -10 LOGOUT Voltage & Error vs. Input Power, Fin = 1900 MHz 3 2.6 3 2.6 IDEAL ERR +25C ERR +85C ERR -40C ERR +25C ERR +85C ERR -40C 1 1.8 1 1.4 0 1.4 0 -1 IDEAL LOGOUT +25C LOGOUT +85C LOGOUT -40C 0.6 0.2 -70 -60 -50 -40 -30 -20 -10 LOGOUT (V) 1.8 1 -1 1 -2 0.6 -3 0.2 0 -70 LOGOUT +25C LOGOUT +85C LOGOUT -40C -50 -40 -30 -20 -10 LOGOUT Voltage & Error vs. Input Power, Fin = 3600 MHz 3 ERR +25C ERR +85C ERR -40C 5 2.2 LOGOUT +25C LOGOUT +85C LOGOUT -40C 2 0 -1 1 0 1.2 0.7 LOGOUT +25C LOGOUT +85C LOGOUT -40C -3 0.2 -70 -60 -50 -40 -30 IDEAL -2 -20 -10 0 INPUT POWER (dBm) ERR +25C ERR +85C ERR -40C -5 0.2 -70 -60 -50 -40 -30 -20 -10 INPUT POWER (dBm) Unless otherwise noted: Vcc1, Vcc2, Vcc3 = +5V, TA = +25C For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com 0 10 ERROR (dB) 1.4 ERROR (dB) 1 LOGOUT (V) 1.7 1.8 0.6 0 INPUT POWER (dBm) 2.6 IDEAL -2 -3 -60 INPUT POWER (dBm) 2.2 2 ERROR (dB) 2.2 ERROR (dB) 2 2.2 LOGOUT Voltage & Error vs. Input Power, Fin = 2200 MHz 8 - 24 0 INPUT POWER (dBm) LOGOUT Voltage & Error vs. Input Power, Fin = 900 MHz LOGOUT (V) -2 LOGOUT +25C LOGOUT +85C LOGOUT -40C INPUT POWER (dBm) LOGOUT (V) 2 ERROR (dB) 2.2 ERROR (dB) LOGOUT (V) ERR +25C ERR +85C ERR -40C 2 0.6 POWER DETECTORS - SMT IDEAL LOGOUT +25C LOGOUT +85C LOGOUT -40C 2.2 8 3 2.6 HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz LOGOUT Voltage & Error vs. Input Power, Fin = 5800 MHz LOGOUT Voltage & Error vs. Input Power, Fin = 7000 MHz 5 2.2 IDEAL LOGOUT +25C LOGOUT +85C LOGOUT -40C -5 -60 -50 -40 -30 -20 -10 0 -5 0.2 -70 10 -60 -50 5 2.2 -20 2.2 LOGOUT +25C LOGOUT +85C LOGOUT -40C -10 0 10 LOGOUT (V) 5 IDEAL 1.4 0 1 0.7 0.6 ERR +25C ERR +85C ERR -40C -5 0.2 -70 -60 -50 -40 -30 -20 -10 0 ERR +25C ERR +85C ERR -40C -5 0.2 10 -70 INPUT POWER (dBm) -40 -30 -20 -10 0 10 LOGOUT Slope vs. Supply Voltage -20 -20 -22 -22 SLOPE (mV/dB) SLOPE (mV/dB) -50 INPUT POWER (dBm) LOGOUT Slope vs. Frequency -24 -26 +25 C +85 C -40 C -28 -60 ERROR (dB) 0 1.2 LOGOUT +25C LOGOUT +85C LOGOUT -40C 1.8 ERROR (dB) LOGOUT (V) -30 LOGOUT Voltage & Error vs. Input Power, Fin = 8000 MHz LOGOUT Voltage & Error vs. Input Power, Fin = 7500 MHz IDEAL -40 INPUT POWER (dBm) INPUT POWER (dBm) 1.7 8 ERR +25C ERR +85C ERR -40C 0.2 -70 LOGOUT (V) 0.7 ERR +25C ERR +85C ERR -40C POWER DETECTORS - SMT 0.7 0 1.2 ERROR (dB) 0 1.2 LOGOUT +25C LOGOUT +85C LOGOUT -40C IDEAL 1.7 ERROR (dB) LOGOUT (V) 1.7 5 2.2 100 MHz 1900 MHz 3600 MHz 5800 MHz 8000 MHz -24 -26 -28 -30 -30 -32 1000 2000 3000 4000 5000 6000 7000 8000 FREQUENCY (MHz) 4.5 5 5.5 Vcc1, Vcc2, Vcc3 (Volts) Unless otherwise noted: Vcc1, Vcc2, Vcc3 = +5V, TA = +25C For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com 8 - 25 HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz LOGOUT Intercept vs. Frequency LOGOUT Intercept vs. Supply Voltage 24 24 20 18 16 14 12 20 18 16 14 12 10 0 1000 2000 3000 4000 5000 6000 7000 10 4.5 8000 5 FREQUENCY (MHz) 5.5 Vcc1, Vcc2, Vcc3 (Volts) LOGOUT Error vs. Input Power, Normalized [2], Fin= 1900 MHz LOGOUT Voltage vs. Input Power & Frequency 2 2.4 50 MHz 100 MHz 900 MHz 1900 MHz 2200 MHz 3600 MHz 5800 MHz 6500 MHz 7000 MHz 7500 MHz 8000 MHz 2.2 1.5 2 1 1.8 0.5 LOGOUT (V) ERROR (dB) POWER DETECTORS - SMT 100MHz 1900 MHz 3600 MHz 5800 MHz 8000 MHz 22 +25 C +85 C -40 C INTERCEPT (dBm) 8 INTERCEPT (dBm) 22 +85 C -40 C 0 -0.5 1.6 1.4 1.2 1 0.8 -1 0.6 0.4 -1.5 0.2 -2 -70 -60 -50 -40 -30 -20 -10 0 -70 0 INPUT POWER (dBm) -60 -50 -40 -30 -20 -10 0 10 INPUT POWER (dBm) 1.2 S11 0. 5 2.0 1.8 0.6 1.6 1.4 0.7 0.8 0.9 1.0 Input Impedance vs Frequency [3] 4 3. 0 0. 0.3 4.0 5.8 GHz 5.0 0.2 6.0 6.8 GHz 2.2 GHz 8.0 10 0.1 10 5.0 4.0 3.6 GHz 3.0 2.0 1.0 0.9 20 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0 0.1 1.9 GHz 0.1 GHz 20 0.1 0.9 GHz 8.0 10 6.0 0.2 5.0 RF Cafe 2002 4.0 4.7 GHz 8.0 GHz 3. 0 0.3 8 - 26 1 .6 1.4 1.2 1.0 0.9 0.8 0.7 0.6 1.8 0. 2 .0 5 0 .4 [1] Unless otherwise noted: Vcc1, Vcc2, Vcc3 = +5V, TA = +25C [2] This data is relative to the room temperature performance of the HMC602LP4(E) [3] Reference plane at J1 connector on eval board For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz Absolute Maximum Ratings +5.5V EN +5.5V VSET Input Voltage +5.5V LOGOUT Output Current 3 mA RF Input Power +15 dBm Junction Temperature 125 C Continuous Pdiss (T = 85C) (Derate 7.95 mW/C above 85C) 1.55 Watts Thermal Resistance (Rth) (junction to lead) 42 C/W Storage Temperature -65 to +150 C Operating Temperature -40 to +85 C ELECTROSTATIC SENSITIVE DEVICE OBSERVE HANDLING PRECAUTIONS 8 POWER DETECTORS - SMT Vcc1, Vcc2, Vcc3 Outline Drawing NOTES: 1. LEADFRAME MATERIAL: COPPER ALLOY 2. DIMENSIONS ARE IN INCHES [MILLIMETERS]. 3. LEAD SPACING TOLERANCE IS NON-CUMULATIVE 4. PAD BURR LENGTH SHALL BE 0.15mm MAXIMUM. PAD BURR HEIGHT SHALL BE 0.05mm MAXIMUM. 5. PACKAGE WARP SHALL NOT EXCEED 0.05mm. 6. ALL GROUND LEADS AND GROUND PADDLE MUST BE SOLDERED TO PCB RF GROUND. 7. REFER TO HMC APPLICATION NOTE FOR SUGGESTED PCB LAND PATTERN. Package Information Part Number Package Body Material Lead Finish MSL Rating HMC602LP4 Low Stress Injection Molded Plastic Sn/Pb Solder MSL1 HMC602LP4E RoHS-compliant Low Stress Injection Molded Plastic 100% matte Sn MSL1 Package Marking [3] [1] H602 XXXX [2] H602 XXXX [1] Max peak reflow temperature of 235 C [2] Max peak reflow temperature of 260 C [3] 4-Digit lot number XXXX For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com 8 - 27 HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz Pin Descriptions Pin Number Function Description 1, 6, 7, 13, 17, 18 N/C These pins are not connected internally; however, this product is specified with these pins connected to RF/DC ground. 2 TEMP Temperature sensor output pin. 3, 4 INP, INN RF Input pins. Connect RF to INP, and AC couple INN to ground for single-ended operation. 5 EN Enable pin, connect to Vcc1, Vcc2, Vcc3 for normal operation. Applying voltage <0.2 x (Vcc1, Vcc2, Vcc3) will initiate power saving mode. 8 - 12, 19, 20, 23, 24 Vcc1, Vcc2, Vcc3 Bias supply. Connect supply voltage to these pins with appropriate filtering. 14 CLPF Loop filter capacitor for output ripple filtering. Interface Schematic POWER DETECTORS - SMT 8 8 - 28 For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz Pin Descriptions (Continued) Pin Number Function Description 15 LOGOUT Logarithmic output that converts the input power to a DC level in detector mode. Short this pin to VSET for detector mode. Interface Schematic 16 VSET VSET input in controller mode. Short this pin to LOGOUT for detector mode. 21, 22 CPB, CPA Temperature compensation pins. Connect CPB directly to ground and leave CPA floating for all frequencies Package Base GND Exposed paddle must be connected to RF and DC ground. For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com POWER DETECTORS - SMT 8 8 - 29 HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz Application & Evaluation PCB Schematic POWER DETECTORS - SMT 8 Notes Note 1: The HMC602LP4 & HMC602LP4E evaluation boards are pre-assembled for single-ended input, and detector/RSSI mode. Note 2: For detector mode, connect high impedance volt meter to the LOGOUT port, and make no connection to VSET. LOGOUT is shorted to VSET by R9, as required for detector mode. Note 3: For controller mode, remove R9 and install 0 ohm resistor (R11), then make appropriate connection to LOGOUT and VSET. In controller mode, the LOGOUT output can be used to drive a variable gain amplifier, or a variable attenuator, either directly or through a buffer or microcontroller. VSET should be connected to an external supply, typically between +0.6 and +1.9V. Note 4: Terminal CPB must be connected to ground for proper operation. 8 - 30 For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com HMC602LP4 / 602LP4E v01.0407 70 dB, LOGARITHMIC DETECTOR / CONTROLLER, 1 - 8000 MHz Evaluation PCB List of Materials for Evaluation PCB 115402 [1] Item Description J1 - J3 PC Mount SMA Connector J4 Molex Connector Header J5 - J11 DC Pin C1, C2 1000 pF Capacitor, 0402 Pkg. C3, C5, C7 100 pF Capacitor, 0402 Pkg. C4, C6, C8 0.1F Capacitor, 0603 Pkg. C9 220 pF Capacitor, 0603 Pkg. R1 68 Resistor, 0603 Pkg. R2 1k Resistor, 0603 Pkg. R3 10k Resistor, 0603 Pkg. R4 - R6, R9 0 Resistor, 0603 Pkg. R8, R12 0 Resistor, 0402 Pkg. U1 HMC602LP4 / HMC602LP4E Logarithmic Detector / Controller PCB [2] 115400 Eval Board The circuit board used in the final application should use RF circuit design techniques. Signal lines should have 50 ohm impedance while the package ground leads and exposed paddle should be connected directly to the ground plane similar to that shown. A sufficient number of via holes should be used to connect the top and bottom ground planes. The evaluation circuit board shown is available from Hittite upon request. POWER DETECTORS - SMT 8 [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 For price, delivery, and to place orders, please contact Hittite Microwave Corporation: 20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373 Order On-line at www.hittite.com 8 - 31