Click on Series name for product info on aimtec.com Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter FEATURES: * AC-DC Constant Current or Constant Voltage LED Driver * Input range 90-305VAC/47-440Hz * High efficiency up to 84% * Operating temperature -40 to 85C * Dimmable via resistive / 0-10Vdc / PWM * 5 Years Limited Warranty Models Single output * * * * * Max Output Power (W) Output Voltage Range (V) Output Current (A) Input Voltage (VAC/Hz) Input Voltage (VDC) AMEPR30-5070AZ 35 36-50 0.7 90-305/47-440 130-430 AMEPR30-4864AZ 30.7 36-48 0.64 90-305/47-440 130-430 AMEPR30-36100AZ 36 24-36 1 90-305/47-440 130-430 AMEPR30-24140AZ 33.6 12-24 1.4 90-305/47-440 130-430 AMEPR30-12250AZ 30 5-12 2.5 90-305/47-440 130-430 Model Over temperature protection Over current protection Waterproof case rated IP68 Power Factor Correction Short circuit protection Mode of Operation Constant Current Constant Voltage Constant Current Constant Voltage Constant Current Constant Voltage Constant Current Constant Voltage Constant Current Constant Voltage Efficiency (%) 115 230 277 VAC VAC VAC 84 84 84 84 84 84 83 83 81 81 83 83 83 83 83 83 82 82 80 80 83 83 83 83 83 83 82 82 80 80 Exceeding the maximum output power will permanently damage the converter. The dimming feature is not supported when units are used in Constant Voltage mode only. In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add "-NA" to part number when ordering. NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-saleAMEPR30-AZ's AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to `dirty' electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current Power factor External fuse Start-up time www.aimtec.com F 052.1e R3.AH Conditions Typical 115 VAC 230 VAC 277 VAC 115 VAC 230 VAC 277 VAC I/O I/FG, O/FG 115 VAC 230 VAC 277 VAC Recommended slow blow type 430 250 210 25 40 55 0.25 3.5 0.96 0.90 0.85 1 450 Tel: +1 514 620 2722 1 of 15 Maximum Units mA mA mA A A A mA mA A ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Output Specifications Parameters Conditions Typical Maximum Units Current accuracy 3 Line regulation (LL-HL) 2 Load regulation 0-100% load 3 Ripple & Noise* 100 Hold-up time 50 100-10 Current adjustment range Tested with 0.1F (C/C) or (M/C) and 47F (E/C) parallel capacitors at the end. Note: from 0% to 10% dimming adjustment signal instability may be present. % % % mV p-p ms % Isolation Specifications Parameters Tested voltage Conditions I/O I/FG O/FG Isolation resistance Typical 3sec 500VDC Rated Units 3750 2000 500 VAC VAC VAC M >1000 General Specifications Parameters Conditions Typical Switching frequency Maximum 130 Over current protection Over voltage protection Short circuit protection Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X W X H) MTBF Units KHz AMEPR30-5070AZ AMEPR30-4864AZ AMEPR30-36100AZ AMEPR30-24140AZ AMEPR30-12250AZ Refer to Constant Current vs. Constant Voltage Mode curve Auto recovery 110~120 With derating over 55C Refer to model application 0.77 0.68 1.04 1.45 2.55 oC oC 100 -40 to +95 0.02 Free air convection Non condensing 20~95 Plastic Epoxy (IP68 rated) UL1015 18AWG * 20CM 530 5.30 x 2.27 x 1.59 inches 134.80 x 57.68 x 40.50 mm >400,000 hrs (MIL-HDBK-217F at t=+25C) A oC oC % / oC % RH g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.AH CE Designed to meet UL8750, IEC/EN 60950-1 standards, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Dimensions End View 40.50 (1.59) Top View 16.75 (0.66) 134.80 (5.30) 57.68 (2.27) 32.00 57.68 (1.26) (2.27) Side View 40.50 (1.59) 200.00 (8.00) 200.00 (8.00) 2.30 (0.09) Input/Output Wires are 18 AWG 20cm 158.50 (6.24) NOTE: to adjust the output current connect a 20K Ohm pot between blue and white wire Wire connection: Connection Wire Brown Blue Green Red Black Blue (Dimming) White (Dimming) AC L AC N Ground +V output -V Output + Vs dimming -Vs dimming Analog (Resistive) Dimming Application Circuit BROWN L GREEN +Vout RED 1st LED 1 AC AMEPR30-AZ BLUE 1 BLUE WHITE www.aimtec.com F 052.1e R3.AH AMEPR30-5070AZ AMEPR30-4864AZ AMEPR30-36100AZ AMEPR30-24140AZ AMEPR30-12250AZ -Vout N Model Number BLACK Maximum Pot Value (k) 4.68 2.98 11.13 42.60 44.04 Pot Tel: +1 514 620 2722 3 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter 0-10V Dimming Application Circuit U1 0-10Vdc +Vs R28 1K5, 0805 -Vs LTV-817C GND PWM (1KHz) Dimming Application Circuit www.aimtec.com F 052.1e R3.AH Tel: +1 514 620 2722 4 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Derating Free Air Convection 55 C 100 80 Safe Operating Area 60 50% 40 20 20% 0 -40 -20 0 20 40 60 70 80 85 100 Ambient Temperature C Efficiency Vs. Input Voltage & Output Current (Constant Current Mode) AMEPR30-5070AZ (%) 90 Efficiency VS. Input Voltage & Output Current 85 85.27 84.24 83.46 80 76.53 75 115Vac 230Vac 277Vac 70 66.42 64.60 65 60 55 50 0 www.aimtec.com F 052.1e R3.AH 0.2 0.4 0.6 0.8 (A) Tel: +1 514 620 2722 5 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter AMEPR30-4864AZ (%) 90.0 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 Efficiency VS. Input Voltage & Output Current 85.2 84.1 83.2 76.2 66.1 64.3 0 0.1 0.2 0.3 0.4 0.5 0.6 115Vac 230Vac 277Vac 0.7 0.8 (A) AMEPR30-36100AZ (%) 90 Efficiency VS. Input Voltage & Output Current 85 80 115Vac 230Vac 277Vac 84.15 84.14 83.95 78.28 75 70 69.30 69.30 65 60 55 50 0.0 0.2 www.aimtec.com F 052.1e R3.AH 0.4 0.6 0.8 1.0 1.2 (A) Tel: +1 514 620 2722 6 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter AMEPR30-24140AZ (%) 90 Efficiency VS. Input Voltage & Output Current 80 115Vac 230Vac 277Vac 84.96 83.54 83.34 85 77.82 75 70 67.24 65 67.24 60 55 50 0.1 0.4 0.7 1.0 1.3 1.6 (A) AMEPR30-12250AZ (%) 90 Efficiency VS. Input Voltage & Output Current 85 80 77.58 75 70 115Vac 230Vac 277Vac 83.50 81.77 81.35 66.09 65 64.71 60 55 50 0 www.aimtec.com F 052.1e R3.AH 1 2 3 (A) Tel: +1 514 620 2722 7 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter PFC Value vs. Output Load Current (Constant Current Mode) AMEPR30-5070AZ PF VS. Output Current (PF) 1.2 1.0 0.8 115VAC 1.00 0.98 0.95 0.85 1.00 0.95 0.90 0.86 230VAC 277VAC 290VAC 0.6 0.4 305VAC 0.48 0.46 0.2 0.0 0.3 0.4 0.5 0.6 0.7 0.8 (A) AMEPR30-4864AZ www.aimtec.com F 052.1e R3.AH Tel: +1 514 620 2722 8 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter AMEPR30-36100AZ PF VS. Output Current (PF) 1.2 1.0 0.8 115VAC 1.00 0.98 0.93 0.99 0.90 0.88 0.78 230VAC 277VAC 290VAC 0.74 0.6 305VAC 0.4 0.48 0.46 0.2 0.0 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 (A) AMEPR30-24140AZ PF VS. Output Current (PF) 1.2 1.00 1.0 0.8 0.6 0.4 0.94 0.89 1.00 0.98 0.93 0.72 0.76 0.46 0.48 115VAC 230VAC 277VAC 290VAC 305VAC 0.2 0.0 0.6 0.8 www.aimtec.com F 052.1e R3.AH 1.0 1.2 1.4 1.6 (A) Tel: +1 514 620 2722 9 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter AMEPR30-12250AZ (PF) 1.2 1.0 0.8 0.6 0.4 PF VS. Output Current 0.99 0.93 115VA C 230VA C 277VA C 1.00 0.98 0.94 0.86 0.82 0.79 0.48 0.46 0.2 0.0 1.15 1.40 1.65 1.90 2.15 2.40 2.65 (A) PFC vs. Output power AMEPR30-5070AZ www.aimtec.com F 052.1e R3.AH Tel: +1 514 620 2722 10 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter AMEPR30-24140AZ Constant Current vs. Constant Voltage Mode AMEPR30-5070AZ Constant Cuurrent Vs Constant Voltage (A) 0.8 36 0.7 50 115 & 230 Vac 0.6 0.5 0.4 0.3 0.2 0.1 50.63 0 36 38 www.aimtec.com F 052.1e R3.AH 40 42 44 46 48 50 52 52 54 (V) Tel: +1 514 620 2722 11 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter AMEPR30-4864AZ Constant Current Vs Constant Voltage (A) 0.7 36 48 0.6 115 & 230 Vac 0.5 0.4 0.3 0.2 0.1 48.6 0.0 36 38 40 42 44 46 48 50 50 52 (V) AMEPR30-36100AZ Constant Current Vs Constant Voltage (A) 1.2 24.00 1.0 36.00 115 & 230 Vac 0.8 0.6 0.4 0.2 36.57 0.0 24 26 www.aimtec.com F 052.1e R3.AH 28 30 32 34 36 38.00 38 40 (V) Tel: +1 514 620 2722 12 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter AMEPR30-24140AZ Constant Current Vs Constant Voltage (A) 1.6 12.0 1.4 24.0 115 & 230 Vac 1.2 1.0 0.8 0.6 0.4 0.2 24.7 0.0 12 14 16 18 20 22 24 26.0 26 28 (V) AMEPR30-12250AZ Constant Current Vs Constant Voltage (A) 3.0 5 2.5 115 & 230 Vac 12 2.0 1.5 1.0 0.5 14 12.6 0.0 5 www.aimtec.com F 052.1e R3.AH 7 9 11 13 15 (V) Tel: +1 514 620 2722 13 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Dimming Control (Output Current vs. Radj) AMEPR30-5070AZ (A) 0.8 Output Current VS. Dimming-Resistance 0.7 0.692 0.6 0.5 115 & 230 Vac 4.682 1.225 0.368 0.225 0.167 0.108 0.0626 0.023 0.01 0 0.4 0.3 0.2 0.1 0 0 2 4 6 (K) AMEPR30-4864AZ (A) 0.7 Output Current VS. Dimming-Resistance 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0.522 2.980 0.964 0.293 0.175 0.096 0.045 0.014 0.002 0.001 0.000 0.0 1.0 2.0 3.0 150 & 230 Vac 4.0 (K) AMEPR30-36100AZ (A) 1.2 Output Current VS. Dimming-Resistance 1.0 2.02 115 & 230 Vac 11.13 3.88 0.8 1.20 0.79 0.57 0.38 0.25 0.15 0.06 0.00 0.6 0.4 0.2 0.0 0 www.aimtec.com F 052.1e R3.AH 5 10 15 (K) Tel: +1 514 620 2722 14 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter AMEPR30-24140AZ (A) 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Output Current vs. Dimming-Resistance 42.3 6.21 2.956 1.804 1.274 0.8699 0.584 0.385 0.226 0.113 0 0 10 20 30 115 & 230 Vac 40 50 K() AMEPR30-12250AZ (A) 3.0 2.5 Output Current VS. Dimming-Resistance. 4.21 115 & 230 Vac 44.04 10.17 2.0 2.82 1.87 1.24 1.0 0.838 0.532 0.5 0.3 0.125 0.0 0 0 10 1.5 20 30 40 50 (K) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.AH Tel: +1 514 620 2722 15 of 15 Toll free: + 1 888 9 AIMTEC (924 6832) North America only