CSM_M7E(80_120_200mm)_DS_E_10_3
1
Digital Display (80/120/200 mm)
M7E
Digital Display with Wire-saving Serial
Transmission Function (B7A Output)
Single-color (red or green) and three-color (red, green, or
orange selectable) displays with a character height of 80, 120,
or 200 mm are available for a variety of applications and
locations.
Thin design with a 39.5-mm depth for the 120-mm model is
perfect for saving space in equipment and devices.
Decimal display including negative sign () display with signal
codes is possible.
Ordering Information
List of Models
Models with 80 mm-high Characters
Models with 120 mm-high Characters
Models with 200 mm-high Characters
Display contents Type Logic input Display color Model
Decimal Front
mounting
Negative Red M7E-08DRN2
Green M7E-08DGN2
Hexadecimal Front
mounting
Red M7E-08HRN2
Green M7E-08HGN2
Display contents Type Logic input Display color Model
Decimal Rear
mounting
Negative Red M7E-12DRN1
Green M7E-12DGN1
Red/green/orange M7E-12DKN1
Front
mounting
Red M7E-12DRN2
Green M7E-12DGN2
Red/green/orange M7E-12DKN2
Hexadecimal Rear
mounting
Red M7E-12HRN1
Green M7E-12HGN1
Red/green/orange M7E-12HKN1
Front
mounting
Red M7E-12HRN2
Green M7E-12HGN2
Red/green/orange M7E-12HKN2
Display contents Type Logic input Display color Model
Decimal Rear
mounting
Negative Red M7E-20DRN1
Green M7E-20DGN1
Red/green/orange M7E-20DKN1
Hexadecimal Rear
mounting
Red M7E-20HRN1
Green M7E-20HGN1
Red/green/orange M7E-20HKN1
Specifications
Ratings
Characteristics
Note: 1. Initial values
2. Impulse conditions:
Rise time: 1 ns +10% max.
Pulse width: 100 ns, 1 μs
Polarity: Positive, negative, asynchronous to power
frequency, 100 Hz repeat frequency.
Rated power supply 24 VDC
Allowable voltage
fluctuation range
90% to 110% of rated voltage
Current consumption
(per display)
M7E-08 (at 24 VDC)
Red LED: 120 mA max.
Green LED: 160 mA max.
M7E-12 (at 24 VDC)
Red LED: 200 mA max.
Green LED: 330 mA max.
Red/Green LED (orange: lit): 330 mA max.
M7E-20 (at 24 VDC)
Red LED: 420 mA max.
Green LED: 500 mA max.
Red/Green LED (orange: lit): 500 mA max.
Input
level
Nega-
tive
logic
Stan-
dard
High: 4 V to power supply voltage
Low: 0 to 1.5 V
Ambient temperature Operating: 10 to 55°C (with no icing)
Storage: 25 to 70°C (with no icing)
Ambient humidity Operating: 35% to 85% (with no
condensation)
Insulation
resistance
100 MΩ min. (at 500 VDC) between each
terminal and mounting panel
Dielectric
strength
500 VAC, 50/60 Hz for 1 min between each
terminal and mounting panel
Noise immunity
(See note.)
Power terminal: ±500 V
Input terminals: ±500 V (normal mode)
±1,500 V (common mode)
Vibration
resistance
Destruction: 10 to 55 Hz, 0.75-mm double
amplitude
Shock resistance Destruction: 300 m/s2
Degree of
protection
IEC IP40 (portion on panel surface)
Connectable PLCs
M7E model PLC's output method
Display Logic
input
Static output
PNP output NPN output
Decimal Negative Not connectable Connectable
Hexadecimal Negative Not connectable Connectable
Accessories (Order Separately)
Harness Connector
Dimensions Model
70 mm M7E-WH0111A
500 mm M7E-WH0511A
1,000 mm M7E-WH1011A
M7E
2
Installation
Cables
Refer to M7E Options for information on using cables
(OMRON XW2Z-R@C, XW2Z-RY@C, and XW2Z-RO-@C-@).
M7E-WH@11A
Harness Connector
Input Codes
Negative Logic Standard Unit
* Either low or high. All inputs are pulled up internally. Therefore high can be open.
Note: 1. Only the numeral will be OFF. (There is no relationship to the decimal point.)
2. Only the numeral will be OFF if there is parallel input with CN1. The decimal point will be lit if there is B7A serial input with TB1.
3. Only the numeral will be OFF if there is parallel input with CN1. The decimal point will be OFF if there is B7A serial input with TB1.
4. The previous statuses of A to D before LE goes low will be held. There is no relationship to the decimal point. The LE latch function will not, however, operate
at the time of serial transmission.
CN3 CN2
Japan Solderless
Terminal EHR-11
L
lModel
70 mm M7E-WH0111A
500 mm M7E-WH0511A
1,000 mm M7E-WH1011A
Input signal Output display condition
Connector pin No. (CN1) ANMLKEF
Terminal symbol LE D C B A DP BI RBI RBO Decimal Hexadecimal
Input signals HHHHHHHL LBlank Blank
HHHHHHHHH 00
HHHHHLH * H 0. 0.
HHHHLHH * H 11
HHHLHHH * H 22
HHHL LHH * H 33
HHLHHHH * H 44
HHLHLHH * H 55
HHL LHHH * H 66
HHLLLHH*H 77
HLHHHHH * H 88
HLHHLHH*H 99
HLHLHHH*H a
H L H L L H H * H Blank (See note 1.) b
H L L H H H H * H DP lights at serial input.
(See note 2.)
c
H L L H L H H * H DP lights at serial input.
(See note 3.)
d
H L L L H H H * H Blank (See note 1.) e
H L L L L H H * H Blank (See note 1.) f
*****LH*H
* * * * * * L * H Blank (See note 1.) Blank (See note 1.)
L * * * * * H * H (See note 4.) (See note 4.)
M7E
3
Terminal Arrangement/Functions
1. Input Terminal
TB1
CN1 (Connector: XG4C-2031 for 80-mm Models,
XG4A-2034 for 120-mm/200-mm Models)
Note: If the R and G of the multi-color display are set low, the Unit will display in orange.
Terminal symbol Name Function
+V Power supply Positive (+) power-supply terminal.
GND Power supply 0 V power-supply terminal.
SI Serial data input B7A serial data received
Terminal
No.
XG4-
2034 pin
No.
Terminal
symbol
Name Function
1(20)LE1 Control input 1st-digit latch input: The previous display is held when this signal is input.
2(18)LE2 Control input 2nd-digit latch input: The previous display is held when this signal is input.
3(16)LE3 Control input 3rd-digit latch input: The previous display is held when this signal is input.
4(14)LE4 Control input 4th-digit latch input: The previous display is held when this signal is input.
5(12)DP Data input The decimal point lights. Operates independently of the LE signal.
6(10)BI Control input Blank input: Turns OFF all the displays.
7(8)R Control input Color selector input: Red is lit when low is input (See note.)
8(6)G Control input Color selector input: Green is lit when low is input (See note.)
9(4)GND Power supply 0 V power-supply terminal. (Terminals 9 and 19 are connected internally.)
10 (2) +V Power supply Positive side (+) power-supply terminal. (Terminals 10 and 20 are connected
internally.)
11 (19) A Data input A (20)
The value and symbol corresponding to the input code
signal are displayed. Refer to the list of input codes for the
contents of display.
12 (17) B Data input B (21)
13 (15) C Data input C (22)
14 (13) D Data input D (23)
15 (11) NC Open ---
16 (9) NC Open ---
17 (7) NC Open ---
18 (5) NC Open ---
19 (3) GND Power supply 0 V power-supply terminal. (Terminals 9 and 19 are connected internally.)
20 (1) +V Power supply Positive side (+) power-supply terminal. (Terminals 10 and 20 are connected
internally.)
Supply voltage: 24 VDC
Terminal Arrangement
Models with 120/200-mm-high
Characters
M7E
4
2. Multi-digit Connection Terminals
CN2, CN3
Note: 1.
The CN2 or CN3 Multi-digit Connector must be used for serial
transmission and dynamic control with the B7A Link Terminal.
Refer to page 5 for details. To use zero suppression, refer to
page 8. Use the CN2 and CN3 for connection with the M7E only.
2. Use the following connectors for the connector terminals:
CN1: XG4M-2030 or equivalent
CN2 and CN3: M7E-WH@11A
Refer to CN1 Terminal Arrangement for the pin numbers.
Refer to page 2 for the dedicated harness.
3. Refer to the list of input codes for RBO or RBI control.
CN1 Terminal Arrangement
Note: 1. The numbers in parentheses are the pin numbers for the
XG4C-2031 Connector for Models with 80-mm-high
Characters and for the XG4A-2034 Connector for Models
with 120/200-mm-high Characters.
2. Connectors
Flat-cable Connector: XG4M-2030
Connectors for Loose Wires with Crimp Terminals:
XG5M-2032-N (Applicable wire gauge: AWG24)
XG5M-2035-N (Applicable wire gauge: AWG28 to AWG26)
Models with 80 mm-high Characters
Block Diagram
Note: Circled numbers are the connector pin numbers. Signal Input Circuit
Negative Logic Model
Terminal
No.
CN2 (IN) CN3 (OUT)
Symbol Name Function Symbol Name Function
1A Data
input A (20)A Data
output A (20)
2B Data
input B (21)B Data
output B (21)
3C Data
input C (22)C Data
output C (22)
4D Data
input D (23)D Data
output D (23)
5+V Power
supply
Positive side
(+) power-
supply terminal
+V Power
supply
Positive side
(+) power-
supply terminal
6GND Power
supply
0 V power-
supply terminal
GND Power
supply
0 V power-
supply terminal
7SI Control
input
B7A serial data
received
SO Control
output
B7A serial data
transmitted
8RBO Control
output
Zero-suppress
output
(See note 3.)
RBI Control
input
Zero-suppress
input
(See note 3.)
9LEI1 Control
input
1st-digit latch
input
LEO1 Control
output
2nd-digit latch
output
10 LEI2 Control
input
2nd-digit latch
input
LEO2 Control
output
3rd-digit latch
output
11 LEI3 Control
input
3rd-digit latch
input
LEO3 Control
output
4th-digit latch
output
(19)(17) (1)
(20)(18) (2)
11 12 13 14 15 16 17 1819 20
12345678910
PCB
View of Mating Portion
CN1
1
11
2
12
10
20
1
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
11
A
B
C
D
+24 V
GND
RBO
SI
LEI1
LEI2
LEI3
A
B
C
D
+24 V
GND
RBI
SO
LEO1
LEO2
LEO3
DSWCN3CN2
TB1
+24 VGNDSI
PCB
Case
Input connector
Power
supply circuit
Input circuit
Driver
LED elements
Multi-digit
connector from
the rightmost digit
Multi-digit
connector to the
leftmost digit
Operation Examples of Zero Suppression
Zero suppression operates when the display is 0, RBI is low, and the decimal
point is not lit. Then low is output to RBO.
Example 1: Zero suppression is not required and the RBI input and RBO
output of each digit are open.
Example 2: Zeros are suppressed only for the digits on the left of the digit
where the decimal is lit when both zero suppression and a
decimal point are being used.
Note: Use RBO output for the connection with RBI input only.
Signal input
3.9 kΩ
4.3 kΩ
+5 V
M7E
5
External Connections
Refer to Block Diagram on page 4 and Terminal Arrangement/Functions on page 3 for external connections for each Unit.
PLC Connections
Refer to your PLC operation manual before connecting the PLC.
PC
OUTPUT UNIT
(BCD output)
Harness connector
M7E-WH@11A
PLC
A to D,
DP, BI
PLC
A to D,
DP, LE
Harness connector
M7E-WH@11A
Static Control
Connected to CS1W-OD261 and CJ1W-OD231 Transistor Output Unit
Connect the PLC's output to the A to D (BCD
output), DP, and BI terminals individually.
Note: Use separate output terminals for DP
or BI control.
Dynamic Control
Connected to C200H-OD215 (Static Mode) Transistor Output Unit
Connect the PLC's output to the A to D (BCD
output) terminals of the rightmost digit.
Latch control is set with the LE1 to LE4 terminals of
the rightmost Unit.
The terminals correspond as follows:
LE1: Rightmost digit (example: 1's digit)
LE2: Second digit (example: 10's digit)
LE3: Third digit (example: 100's digit)
LE4: Forth digit (example: 1,000's digit)
Note: 1. The display colors of the three-color displays must be selected individually.
2. In static mode, ladder programming is required for latch control.
3. If the cycle time of the PLC is too short, its relationship with the ON/OFF
response time of the M7E may not work well. Set a minimum cycle time or
otherwise adjust the cycle time accordingly.
4. The reception of orders for C200H-OD215 was discontinued at the end of
March 2017.The recommended replacements are the CS1W-OD231 and
CJ1W-OD231, but they not Dynamic Output Units. Therefore, ladder
programming will be required to use them as replacements.
B7A Link Terminal By supplying power to a single display, all the displays will be
supplied with power.
The B7A's serial output must be connected to the SI terminal of
the rightmost TB1.
Use OMRON's M7E-WH@11A Harness Connectors or
equivalent to connect all Units.
The DP and BI terminals can be controlled by transmitting the
following special data
Hexadecimal C data: Turns ON the decimal point of the relevant
digit.
Hexadecimal D data: Turns OFF the decimal point of the
relevant digit.
Hexadecimal F data: Deletes the display (BI control) of the
relevant digit.
Use the B7A Link Terminal with a normal I/O delay of 19.2 ms.
The B7A with short I/O delay cannot be used.
Note: The display colors of the three-color displays must be selected individually.
Connected to CS1W-OD211 and CJ1W-OD211
Transistor Output Unit
M7E
6
Serial Transmission with B7A Link Terminal
A series of models incorporating a communications (serial transmission) function is available.
By using the B7A Link Terminal (PLC connector model), the Units can be connected to the PLC with ease. The 16-point B7A Link Terminal allows
the control of a maximum of four digits over two wires.
Available Link Terminal Models
Transmission Path
Transmission distance:
A maximum transmission distance of 500 m is
possible by using the VCTF 0.75 x 2C Cable if
power is supplied independently to the Input and
Output Link Terminals.
A maximum transmission distance of 100 m is
possible by using the VCTF 0.75 x 3C Cable if a
single pow er supply is connected to the Input or
Output Link Terminal, in which case the current
flow on the power lines (positive and negative
lines) is 1.8 A maximum.
Transmission delay:
A maximum of 50 ms for data display after the
B7A's input signal becomes definite.
Minimum Input Time
Use an input time of 80 ms min. to the Input
Unit for the B7A.
Signal Allocation
B7A-M7E Corresponding Pin List
The B7A's switch terminals correspond to the
M7E's parallel input signals as follows:
Note: A maximum of two Display Units can be
connected when the 10-point B7A Link
Terminal is used and a maximum of four
Display Units can be connected when the
16-point B7A Link Terminal is used.
Errors
1. No signal transmission is available due to the
disconnection of the transmission path (the SI
or GND wire).
2. The waveform is greatly distorted due to
ex ternal noise interference or because the
transmission path is longer than the
permissible transmission path.
Error Indication
When an error results, “-” will be displayed and
the display will flash. After the condition returns to
normal, reception data will be displayed.
Display after Error
Correction
After the condition returns to normal, the display
will be reset automatically and reception data will
be displayed.
Transmission side Wiring No. of I/O points Connectable M7E
Display Units
B7A-T10S1 Screw terminal model 10 2 Note: 1. Use the B7A Link Terminal with a normal I/O delay of
19.2 ms. The B7A with short I/O delay cannot be used.
2. The connection of the 32-point connector model is as
follows:
3. For details on corresponding models, refer to each
applicable model’s catalog.
B7A-T10S3 Screw terminal model 10 2
B7A-T10M2 Module model 10 2
B7A-T6A1 Screw terminal model 16 4
B7A-T6B1 Screw terminal model 16 4
B7A-T6C1 Screw terminal model 16 4
B7A-T6D2 Module model 16 4
B7A-T6E3 Connector model 16 4
B7A-T3E3 (See note 2.) Connector model 32 8
C200H-B7A (See note 3.) Screw terminal model 16 × @ ports 4 × @ ports
CQM1-B7A (See note 3.) Screw terminal model 16 × @ ports 4 × @ ports
CJ1W-B7A (See note 3.) Screw terminal model 16 × @ ports 4 × @ ports
CS1W-B7A (See note 3.) Screw terminal model 16 × @ ports 4 × @ ports
M7E-08/12/20
M7E-08/12/20
Transmission distance: 500 m max.
24-VDC
power
supply DC power
supply
24-VDC
power
supply
Transmission distance: 100 m max.
(12 to 24 V)
B7A
(PLC connector model)
B7A
(PLC connector model)
PLC
PLC
Power Supplies Placed on Both the Transmitting and Receiving Sides
Power Supply Placed Only on the Receiving Side
Units can be
connected easily
with the dedicated
harness.
SIG1
SIG2
PLC
connector
model 32
points
B7A switch terminal M7E parallel input
A0
A1
A2
A3
First digit
(1's digit) A
B
C
D
A4
A5
A6
A7
Second dig i t
(10's digit) A
B
C
D
A8
A9
A10
A11
Third digit
(100's digit) A
B
C
D
A12
A13
A14
A15
Fourth digit
(1000's digit) A
B
C
D
M7E
7
Serial Transmission Control Examples
1. 1234 is displayed.
Note: The transmission data is hexadecimal.
2. 123 is displayed.
3. 12.34 is displayed.
4. 9.876 is displayed.
5. 4.2-1 is displayed.
6. The displayed decimal point will be OFF.
7. Changing the numeral and decimal point simultaneously.
(It is, however, impossible to change the numeral and decimal
point on the same digit simultaneously.)
8. Turn OFF the display by sending data F.
Note: DP and BI control using serial transmission is not displayed in
hexadecimal.
A Variety of Control Operations with Short-circuit Sockets
By removing the rear cover of the Display Unit and setting the XJ8A-0211 Short-circuit Socket, the following control operations are possible.
Transmission data
1234 Display 1234
Transmission data
A123 Display 123
Transmission data
DCDD Display 1. 2 3 (The decimal point
is controlled first.)
Transmission data
1234 Display 12.34(Numeral data is
transmitted next.)
Transmission data
CDDD Display 12.34(The decimal point
is controlled first.)
Transmission data
9876 Display 9. 8 7 6 (Numeral data is
transmitted next.)
Transmission data
42A1 Display 4. 2 1(Numeral setting
is possible.)
Transmission data
DDDD Display 421
Transmission data
C311 Display 4311
Transmission data
DDDD Display 4314(The decimal
point is OFF.)
Transmission data
32F1 Display 32 1
(Display turns OFF
with F transmission.)
ON
ONOFF
ONOFF
ONOFF
OFF
RBI
TER
1. DP (J5)
2. RBI (J9)
TER (J11)
3. R (J8)
G (J10)
Short-circuit
socket
ON
123456 SW1
DP
RBI
TER
N.C
SEL1
SEL2
M7E
Leftmost digit
Short-circuited
Short-circuited
Open
Short-circuited
Open
Short-circuited
Open
Open
M7E
Rightmost digit
M7E-WH@11A
M7E
RBI (J9)
TER (J11)
M7E
Decimal Control
Short-circuit the DP (J5) terminals with a short-circuit socket so that the decimal point will be
always lit.
The short-circuit socket is short circuited at the factory (i.e., normally lit). Open the short-circuit
socket if external control or lighting are not required
Zero Suppression Control
When the z ero suppre ssio n funct ion is not u se d, the RB I (J9 ) terminals mu st b e o pen. The TER
(J11) terminals can be either short-circuited or open.
When zero suppre ssio n i s not used, the RBI (J9) terminals of the M7E Digital Display Unit for
the leftmost digit must be short-circuited, those of all the other M7E Digital Displa y Units m ust be
open, the TER (J11) terminals of the M7E Digital Display Unit for the rightmost digit must be
open, and those of all the other M7E Digital Display Units must be shor t-circuited.
Example of Zero Supp r ession Setting for Four Digits on the M7E (120/
200-mm Model)
Note: To use zero suppression, CN2 and CN3 must be connected with an M7E-
WH@11A Harness Connector.
In static mode, ladder programming is required for latch control. If latch control
is not used, cut the data I/O lines (pins 1 to 4) on the Harness Connector.
Display Color Contr ol (Three-color Model Only)
Short-circuit the R (J8) terminals with a short-circuit socket so that the display will be lit in red.
Short-circuit the G (J10) terminals with a short-circuit socket so that the display will be lit in
green.
Short-circuit the R (J8) as well as G (J10) terminals with two short-circuit so ckets so that the
display will be lit in orange.
Note: When the R (J8) as well as G (J10) terminals are open, the display will be OFF if the CN1
Input Connector has not been connected yet.
Note: 1. All the terminals are short-circuited before shipping. Short-circuit or open the terminals according
to the application.
2. Single-color (red or green) models do not incorporate the R (J8) and G (J10) terminals.
3. These terminals must be open when controlling the DP (J5), R (J8), and G (J10) terminals
externally by inputting signals from the CN1. (The short-circuit socket will take precedence.)
4. All the terminals J5 to J11 are connected to GND.
5. The 80-mm Model uses DIP switches. ON: Short-circuited OFF: Open
(SEL1 and SEL2 are switches to adjust brightness.)
80-mm Model
DIP Switch
Pins 1 to 4 are all factory-set
to OFF.
Pins 5 and 6 are factory-set
for brightness adjustment. Do
not change the setting of
these pins; the brightness will
change.
Example of Zero Suppr ession Setting for Four Digits on the M7E (80-
mm Model)
M7E
8
Zero Suppression
To use zero suppression, first connect the CN3 and CN2 connectors on the M7E to the M7E-WH@11A Harness Connector.
Then, set the DIP s witch on the M7E-08@ (80-mm model) or short the required pins with short-circuit sockets on the M7E-12@ (80-mm model) or
M7E-20@(200-mm model).
Zero Suppression for 80-mm Models
To use zero suppression, turn ON the RBI and TER pins on the DIP
switch on the M7E for the most-significant digit, turn OFF the RBI
and TER pins on the DIP switch on the M7E for the least-significant
digit, and then turn the RBI pin OFF and the TER pin ON on the DIP
switches on the M7E for the other digits.
To use zero suppression, CN2 and CN3 must be connected with the
M7E-WH@11A Harness Connector.
In static mode, ladder programming is required for latch control. If latch
control is not used, cut the data I/O lines (pins 1 to 4) on the Harness
Connector.
Example of Zero Suppression Setting for Four Digits on
the M7E (80-mm Model)
Zero Suppression for 120/200-mm Models
To use zero suppression, short-circuit the RBI and TER pins with the
short-circuit sockets on the M7E for the most-significant digit, and
leave these pins open on the M7E for the least-significant digit. For
the M7E for other digits, leave the RBI pin open and short-circuit the
TER pin.
By removing the rear cover of the Display Unit and setting the XJ8A-
0211 Short-circuit Socket, the following control operations are
possible.
To use zero suppression, CN2 and CN3 must be connected with the
M7E-WH@11A Harness Connector.
In static mode, ladder programming is required for latch control. If latch
control is not used, cut the data I/O lines (pins 1 to 4) on the Harness
Connector.
Note: 1. All the terminals are short-circuited before shipping. Short-
circuit or open the terminals according to the application.
2. Single-color (red or green) models do not incorporate the R
(J8) and G (J10) terminals.
3. These terminals must be open when controlling the DP (J5),
R (J8), and G (J10) terminals externally by inputting signals
from the CN1. (The short-circuit socket will take
precedence.)
4. All the terminals J5 to J11 are connected to GND.
ON
123456 SW1
DP
RBI
TER
N.C
SEL1
SEL2
DIP Switch
Pins 1 to 4 are all factory-set to OFF.
Pins 5 and 6 are factory-set for
brightness adjustment. Do not
change the setting of these pins;
the brightness will change.
OFF
ON/OFF OFF
ON/OFF OFF
ON/OFF OFF
ON/OFF
RBI
TER
ON
ONOFF
ONOFF
ONOFF
OFF
RBI
TER
M7E-WH@11A
M7E M7E
ON
ONOFF
ONOFF
ONOFF
OFF
RBI
TER Turn ON pin 1 on the DIP switch
to light the decimal point.
OFF
ON/OFF OFF
ON/OFF OFF
ON/OFF ON
ON/OFF
RBI
TER
M7E
Leftmost digit
M7E
Rightmost digit
M7E-WH@11A
M7E M7E
M7E
Leftmost digit
M7E
Rightmost digit
M7E-WH@11A
M7E M7E
M7E
Leftmost digit
M7E
Rightmost digit
Short-circuit
socket
- - - - - - -1. DP (J5) Decimal Control
Short-circuit the DP (J5) terminals with a short-
circuit socket so that the decimal point will be
always lit.
The short-circuit socket is short circuited at the
factory (i.e., normally lit). Open the short-circuit
sock et if e x ternal control or light ing are n ot required
- - - -2. RBI (J9)
TER (J11) Zero Suppression Control
When the zero suppression function is not used, the
RBI (J9) terminals must be open. The TER (J11)
terminals can be either short-circuited or ope n.
When zero suppression is not used, the RBI (J9)
terminals of the M7E Digital Display Unit f or the leftmost
digit must be short-circuited, those of all the other M7E
Digital Display Units must be open, the TER (J11)
terminals of the M7E Digital Display Unit f or the
rightmost digit must be open, and those of all the other
M7E Digital Disp lay Units must be short-circuited.
M7E
9
Example of Zero Suppression Setting for Four Digits on
the M7E (120/200-mm Model)
RBI
TER
RBI
TER
M7E-WH@11A
M7E M7E
Open
Open
Open
Short-circuited
Open
Short-circuited
Short-circuited
Short-circuited
RBI
TER Turn ON pin 1 on the DIP switch
to light the decimal point.
Short-circuited
Open/Short-circuited
Open
Open/Short-circuited
Open
Open/Short-circuited
Open
Open/Short-circuited
RBI
TER
M7E
Leftmost digit
M7E
Rightmost digit
M7E-WH@11A
M7E M7E
M7E
Leftmost digit
M7E
Rightmost digit
M7E-WH@11A
M7E M7E
M7E
Leftmost digit
M7E
Rightmost digit
Open
Open/Short-circuited
Open
Open/Short-circuited
Open
Open/Short-circuited
Open
Open/Short-circuited
Open
Open
Open
Short-circuited
Open
Short-circuited
Short-circuited
Short-circuited
M7E
10
Operation
Operation Timing (Input Signal Timing)
Operation Chart
The following example shows the relationship between each input terminal and the display condition.
ts
tw
th
Data latch
Data input
signals A to D
Latching
input LE
tw: Pulse duration
th: Hold time
ts: Setup time
Data latchData read
H
L
Pulse duration (tw) 1.5 ms
Hold time (th) 0.75 ms
Setup time (ts) 2. 2 5 m s
Negative Logic
Data
Terminal
displayed
value
0123456789 Description
Input
signals A
(20)H
L
Inputs the data signal
as BCD (or binary
code).
B
(21)H
L
C
(22)H
L
D
(23)H
L
DP H
L
Low when the decimal
point lights. The
decimal point can light
without regard to the LE
signal.
BI H
L
Low when the display is
turned OFF.
LE H
L
Low when the display is
to be retained. (High is
retained until the signal
goes low.)
Display
condition ---
Remarks ---
(No display)
The “1” display is retained by
the LE signal. The “5” display is retained
by the LE signal. The display turned OFF by
the BI signal (no display).
M7E
11
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Note: Tolerance is ±0.4 mm unless otherwise specified.
Note: Tolerance is ±0.4 mm unless otherwise specified.
A
72.4
76
113 108.6
25.7
29.3
3
109.6±0.2
46
80
7°
M7E-08@@N2 Number
of Units Dimension
A
1
2
3
4
5
6
7
8
73.1±0.4
149.3±0.4
225.5±0.4
301.7±0.4
377.9±0.4
454.1±0.4
530.3±0.4
606.5±0.4
Panel Cutout
(Panel thickness: 1 to 4 mm)
LED
114
42.5
165.6
3
170
110.4
A
166.6±0.2
120
7°
69
M7E-12@@N2 Number
of Units Dimension
A
1
2
3
4
5
6
7
8
111.1±0.4
225.3±0.4
339.5±0.4
453.7±0.4
567.9±0.4
682.1±0.4
796.3±0.4
910.5±0.4
LED
Panel Cutout
(Panel thickness: 1 to 4 mm)
160.8164180195
16.7 25.5
58
105.6
5
42.2
180±0.2 165±0.2
5 dia. (max.)
106±0.2
58±0.2 A
120
7°
69
M7E-12@@N1
Number
of Units Dimension
A
1
2
3
4
5
6
7
8
106.6±0.4
212.6±0.4
318.6±0.4
424.6±0.4
530.6±0.4
636.6±0.4
742.6±0.4
848.6±0.4
Panel Cutout LED
243
19.6 22.4
42.2
266.2281296
120
176
5
281±0.2 267.2±0.2
5 dia. (max.)
A
120±0.2
176.4±0.2
200
7°
116
M7E-20@@N1
Number
of Units Dimension
A
1
2
3
4
5
6
7
8
177±0.4
353.4±0.4
529.8±0.4
706.2±0.4
882.6±0.4
1,059±0.4
1,235.4±0.4
1,411.8±0.4
Panel Cutout LED
M7E
12
Safety Precautions
Precautions for Correct Use
Environment
Use the switches in locations that are not subject to organic
solvents (thinner , benz ene, etc.), strong alkali, strong acid, sunlight,
corrosive gases, water, and oil.
Use the units in areas not subject to vibration or shoc k in excess of
specifications.
Wiring
When wiring with terminals or a connector, remove the rear cover
of the M7E and connect the M7E to the terminals or connector
properly, and be sure not to leave any wire cuttings inside the
Display Unit.
Make sure that no wire is more than five meters long when wiring
the B7A link terminal.
Mounting
When mounting Display Units to a box, make slits on the rear part
and the top of the box for ventilation. If there is no proper ventilation,
the life of each Display Unit may be shortened.
Connecting Cable
When connecting an XG4M-2030 or XG4M-2030-T G79 Cable to a
Digital Display with 80-mm-high Characters, an XG4Z-0002 Lock
Lever can be used.
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2017.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2017 All Right Reserved.