SIMATIC MV320 / SIMATIC MV325
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
SIMATIC Ident
Handheld reading systems
SIMATIC MV320 / SIMATIC MV325
Operating Instructions
08/2015
C79000
-G8976-C352-03
Preface
Safety notes
1
Description
2
Installing and connecting
(SIMATIC MV325)
3
Connecting (SIMATIC
MV320)
4
Commissioning
5
Operation
6
Alarm, error and system
messages
7
Service and maintenance
8
Technical data
9
Dimension drawings
10
Ordering data
11
Appendix
A
ERG
C79000-G8976-C352-03
09/2015 Subject to change
Copyright © Siemens AG 2013 - 2015.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified
for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 3
Preface
Validity of these operating instructions
This document contains information on the products listed below.
Valid for devices with the following article numbers
Article number
Device
6GF3320-0HT01
SIMATIC MV320
6GF3325-0HT01
SIMATIC MV325
The SIMATIC MV320 and SIMATIC MV325 readers are sophisticated, powerful, and
versatile handheld barcode readers. Typical areas of application: Health care, pharmacy,
retail trade and manufacturing.
SIMATIC MV320
SIMATIC MV325
Product designation
In the remainder of this document, the term "device" or "reader" or "handheld reader" is also
used instead of the full product name "SIMATIC MV320" or "SIMATIC MV325".
Preface
SIMATIC MV320 / SIMATIC MV325
4 Operating Instructions, 08/2015, C79000-G8976-C352-03
Purpose of the operating instructions
Note
The operating instructions contain all the important information about the device
Read the operating instructions before starting to work with this device.
Noting and acting on this information:
Ensures the device functions correctly
Saves you service costs
These operating instructions contain all the information you need for commissioning and
using the device.
It is intended both for persons who connect up the device electrically and commission and
operate it as well as for service technicians and maintenance technicians.
New in this release
Revision of contents and editing
Code configuration section updated and removed from manual.
Replaced operating instructions
These operating instructions replace the operating instructions edition 03/2014.
Current operating instructions on the Internet
You will also find the latest version of these operating instructions on the Internet pages of
Siemens Industry Online Support under the following entry ID:
78905254 (https://support.industry.siemens.com/cs/ww/en/view/78905254)
Additional documentation
A current list of the code configurations mentioned in this manual is available in the manuals:
SIMATIC MV320 Configuration guide
(https://support.industry.siemens.com/cs/ww/en/ps/15160/man)
SIMATIC MV325 Configuration guide
(https://support.industry.siemens.com/cs/ww/en/ps/15161/man)
Environmental protection
Devices described in this programming manual can be recycled owing to the low content of
noxious substances in their version. Please contact a certified waste disposal company for
eco-friendly recycling and to dispose of your old devices.
Preface
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 5
History
Previous editions of these operating instructions:
Edition
Remark
12/2013
First edition
08/2015 Revision of contents and editing
Code configuration section updated and removed from manual.
Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, solutions, machines, equipment and/or networks. They are
important components in a holistic industrial security concept. With this in mind, Siemens
products and solutions undergo continuous development. Siemens recommends strongly
that you regularly check for product updates.
For the secure operation of Siemens products and solutions, it is necessary to take suitable
preventive action (e.g. cell protection concept) and integrate each component into a holistic,
state-of-the-art industrial security concept. Third-party products that may be in use should
also be considered. For more information about industrial security, visit
http://www.siemens.com/industrialsecurity.
To stay informed about product updates as they occur, sign up for a product-specific
newsletter. For more information, visit http://support.automation.siemens.com.
Preface
SIMATIC MV320 / SIMATIC MV325
6 Operating Instructions, 08/2015, C79000-G8976-C352-03
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 7
Table of contents
Preface ................................................................................................................................................... 3
1 Safety notes ............................................................................................................................................ 9
2 Description ............................................................................................................................................ 11
2.1 Product package ..................................................................................................................... 11
2.2 SIMATIC MV320 ..................................................................................................................... 12
2.3 SIMATIC MV325 ..................................................................................................................... 13
3 Installing and connecting (SIMATIC MV325) ......................................................................................... 15
3.1 Mounting the charging station ................................................................................................. 15
3.2 Mounting the charging station with base plate and rubber feet .............................................. 16
3.3 Charging station with base plate secured to a working surface ............................................. 19
4 Connecting (SIMATIC MV320) .............................................................................................................. 21
4.1 Connecting and removing cables ........................................................................................... 21
4.2 Connector assignment USB and RS-232 cable ..................................................................... 22
4.3 Connector assignment reader ................................................................................................ 24
5 Commissioning ..................................................................................................................................... 25
5.1 Inserting and removing the battery (SIMATIC MV325) ........................................................... 25
5.2 Charging the reader (SIMATIC MV325) ................................................................................. 25
5.3 Turn the reader on .................................................................................................................. 27
5.4 Establishing a Bluetooth connection (SIMATIC MV325) ........................................................ 28
6 Operation .............................................................................................................................................. 29
6.1 Working with the SIMATIC MV320 reader .............................................................................. 29
6.2 Aligning the SIMATIC MV325 reader ...................................................................................... 31
6.3 Setting the communication mode (SIMATIC MV325) ............................................................. 32
6.4 Communication in batch mode (SIMATIC MV325) ................................................................. 33
6.5 Codes with enabled factory setting ......................................................................................... 35
6.6 Codes with disabled factory setting ........................................................................................ 36
6.7 Enabling "Suffix - Enter" .......................................................................................................... 38
7 Alarm, error and system messages ....................................................................................................... 39
7.1 Feedback from the reader ...................................................................................................... 39
7.2 Charge status displays of the battery (SIMATIC MV325) ....................................................... 40
7.3 Batch mode display (SIMATIC MV325) .................................................................................. 41
Table of contents
SIMATIC MV320 / SIMATIC MV325
8 Operating Instructions, 08/2015, C79000-G8976-C352-03
8 Service and maintenance ...................................................................................................................... 43
9 Technical data ...................................................................................................................................... 45
10 Dimension drawings .............................................................................................................................. 49
11 Ordering data ........................................................................................................................................ 51
A Appendix .............................................................................................................................................. 53
A.1 Code configurations ............................................................................................................... 53
A.2 "Specify character length to be read" function ....................................................................... 54
A.3 Service and Support .............................................................................................................. 57
A.4 Certificates and approvals ..................................................................................................... 59
A.4.1 FCC information ..................................................................................................................... 61
A.4.2 IC-FCB information ................................................................................................................ 62
Index .................................................................................................................................................... 63
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 9
Safety notes
1
Alterations to the device
CAUTION
Alterations to the devices are not permitted.
Failure to observe this requirement shall constitute a revocation of the radio equipment
approval, CE approval and warranty. Therefore do not make any alterations to the device.
Repairs
WARNING
Personal injury or equipment damage due to unauthorized opening or repairing
Unauthorized opening or repairing of the device can lead to personal injury or equipment
damage. Therefore do not carry out repairs yourself. Repairs may only be carried out by
authorized qualified personnel at the manufacturer's site. See section Service and
maintenance (Page 43).
Proper disposal and recycling
The HMI devices described in these Operating Instructions can be recycled due to the low
levels of pollutants. Contact a certified disposal service company for environmentally sound
recycling and disposal of your old devices.
When disposing of batteries, observe the locally applicable legal regulations.
Safety notes
SIMATIC MV320 / SIMATIC MV325
10 Operating Instructions, 08/2015, C79000-G8976-C352-03
Adherence to FCC requirements
NOTICE
Adherence to FCC requirements for RF radiation
To adhere to the FCC requirements relating to the effects of RF radiation, this device must
not be operated beside or in conjunction with other antennas or transmitting devices.
NOTICE
Changes or modifications to the device
Changes or modifications not expressly approved by the person responsible for adherence
to the relevant regulations could result in the loss of the user's operating approval for the
device.
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 11
Description
2
2.1
Product package
SIMATIC MV320
The SIMATIC MV320 reader (article number 6GF3320-0HT01) is supplied with the following
components:
SIMATIC MV320 handheld reader
The reader can be used on the USB or RS-232 interface. To use the RS-232 interface, you
need to order the RS-232 cable and, if necessary, the appropriate power supply as
accessories.
SIMATIC MV325
The SIMATIC MV325 reader (article number 6GF3325-0HT01) is supplied with the following
components:
SIMATIC MV325 handheld reader with battery, charging station and USB cable (0.9 m)
The charging station has a USB interface and a Bluetooth wireless interface.
Description
2.2 SIMATIC MV320
SIMATIC MV320 / SIMATIC MV325
12 Operating Instructions, 08/2015, C79000-G8976-C352-03
2.2
SIMATIC MV320
Characteristics and areas of application
Due to the following features, the reader is also suitable for demanding applications.
Due to the optical dual-field platform, the SIMATIC MV320 can read wide and extremely
small barcodes.
Thanks to intuitive targeting, 1D and 2D barcodes as well as barcodes belonging to postal
services can be read reliably and at little expense.
Thanks to glare control, barcodes can be read from bottles, packed foodstuffs and cans
without any problem.
Whether in health care, retail trade or in other areas of application with intensive use - the
plastic housing, which is resistant to disinfectants and has degree of protection IP54,
protects the performance and the working lifetime of the reader from aggressive cleaning
agents, dust, penetration of water and even being dropped.
Are you on the move, working in different environments or do you need to read codes
accurately on a large number of items? If so, the SIMATIC MV320 will be a valuable addition
to your equipment.
Areas of application
Health care
Mobile voucher or ticket reader (events, air tickets, cinema etc.)
Pharmacy
Retail trade and manufacturing
Reading strongly reflecting barcodes
Overview of the functions and benefits
Available on a stand or as a handheld device.
Manual or automatic triggering
Feedback on correct read function with programmable LED display, acoustic signal and
vibration.
Optional metal stand
Efficient current consumption
Description
2.3 SIMATIC MV325
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 13
2.3
SIMATIC MV325
Characteristics and areas of application
Due to the following features, the reader is also suitable for demanding applications.
The super fast and extremely durable device works with a high-performance scan engine
for recognition of all 1D and 2D barcodes, as well as barcodes of individual postal
services.
With its patented dual-field optics, both wide and very small barcodes can be read.
With the patented glare control technology, codes on shining surfaces can be reliably
detected.
The long-life batteries of the device with their fast triggering mechanism measure the
battery charge level precisely and show the remaining lifetime of the battery in a 4 LED
level display at the press of a button.
The charging station is available with an integrated Bluetooth modem.
The housing, which is resistant to disinfectants and has degree of protection IP65,
prevents damage to plastic parts and protects the electronics and optics.
Areas of application
Health care
Manufacturing
Retail trade
Warehouse management
Reading strongly reflecting barcodes
Overview of the functions and benefits
Light design: The reader weighs only 171 g.
Long-life batteries with fast trigger mechanism.
Charge status LED with charge display.
Read confirmation by vibration, acoustic and LED signal.
Fast, direction-independent reading of 1D and 2D barcodes and barcodes of postal
services.
Compatible with Bluetooth-supported Android, iOS and Windows mobile devices and
tablets.
The housing, which is resistant to disinfectants and has IP65, prevents damage to plastic
parts and protects the electronics and optics.
Paging button supports the localization of the mobile reader.
Reads barcodes on mobile devices.
Description
2.3 SIMATIC MV325
SIMATIC MV320 / SIMATIC MV325
14 Operating Instructions, 08/2015, C79000-G8976-C352-03
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 15
Installing and connecting (SIMATIC MV325)
3
3.1
Mounting the charging station
You can mount the charging station according to your requirements:
Charging station without base plate (Page 15)
Charging station with base plate (Page 16)
Secure charging station with base plate to a working surface (Page 19)
1. Insert the USB cable or power cable with the cylindrical side into the charging station.
Figure 3-1 Inserting the USB cable/power cable into the charging station
2. To prevent the station from slipping: Secure the rubber feet to the corners on the
underside of the charging station.
Figure 3-2 Charging station: Securing the rubber feet
Installing and connecting (SIMATIC MV325)
3.2 Mounting the charging station with base plate and rubber feet
SIMATIC MV320 / SIMATIC MV325
16 Operating Instructions, 08/2015, C79000-G8976-C352-03
The charging station is ready for use.
3.2
Mounting the charging station with base plate and rubber feet
1. Insert the USB cable or power cable with the cylindrical side into the charging station.
Figure 3-3 Inserting the USB cable/power cable into the charging station
For mounting the weighted base plate:
2. Lay the side of the base plate marked with "THIS SIDE DOWN" on the supporting
surface.
3. Place the charging station on the base plate.
Installing and connecting (SIMATIC MV325)
3.2 Mounting the charging station with base plate and rubber feet
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 17
4. Secure the charging station with the supplied screws in the threaded holes of the
base plate.
Figure 3-4 Base plate: Threaded holes
Figure 3-5 Charging station: Tightening the screws
You have secured the charging station to the base plate.
Installing and connecting (SIMATIC MV325)
3.2 Mounting the charging station with base plate and rubber feet
SIMATIC MV320 / SIMATIC MV325
18 Operating Instructions, 08/2015, C79000-G8976-C352-03
5. To prevent the charging station from slipping: Secure the rubber feet to the round
markers on the underside of the base plate.
Figure 3-6 Base plate: Rubber feet markers
Figure 3-7 Base plate: Rubber feet secured
The charging station is ready for use.
Installing and connecting (SIMATIC MV325)
3.3 Charging station with base plate secured to a working surface
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 19
3.3
Charging station with base plate secured to a working surface
1. Insert the USB cable or power cable with the cylindrical side into the charging station.
Figure 3-8 Inserting the USB cable/power cable into the charging station
To mount the charging station on a working surface:
2. Lay the side of the base plate marked with "THIS SIDE DOWN" on the supporting
surface.
3. Secure the base plate to the working surface with screws through the pre-drilled mounting
holes .
Note
Mounting screws are not supplied with the product
Since the mounting surfaces can differ, the mounting screws are not sup
plied with the
product.
Figure 3-9 Base plate: Mounting holes
Installing and connecting (SIMATIC MV325)
3.3 Charging station with base plate secured to a working surface
SIMATIC MV320 / SIMATIC MV325
20 Operating Instructions, 08/2015, C79000-G8976-C352-03
4. Place the charging station on the secured base plate.
5. Secure the charging station with the supplied screws in the threaded holes of the
base plate.
Figure 3-10 Base plate: Threaded holes
Figure 3-11 Charging station: Tightening the screws
You have secured the charging station with the base plate on the working surface.
The charging station is ready for use.
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 21
Connecting (SIMATIC MV320)
4
NOTICE
Avoid exceeding the maximum voltage
If the maximum voltage is exceeded, this voids the manufacturer's guarantee.
Maximum voltage tolerance: 5 V ± 10 %
The components must comply with the requirements of the EC directive RoHS and the
REACH Regulation: See EC directive 2011/65/EU (RoHS 2) and the Regulation (EC) No.
1907/2006 (REACH Regulation).
4.1
Connecting and removing cables
Connecting the cable
Plug the RJ-50 end of the cable into the bottom of the device handle.
Press the connector firmly into the device until it audibly locks in place. The cable is then
correctly connected.
Connecting (SIMATIC MV320)
4.2 Connector assignment USB and RS-232 cable
SIMATIC MV320 / SIMATIC MV325
22 Operating Instructions, 08/2015, C79000-G8976-C352-03
Removing the cable
1. Insert a paper clip into the opening on the side of the device handle.
2. Remove the cable carefully from the device.
4.2
Connector assignment USB and RS-232 cable
USB cable
Example with connector assignments
:
Table 4- 1 Connector table
Connector A
Designation
Wire
Color
Connector B
1
VIN
24 AWG
Red
1
2
DM
28 AWG
White
2
3
DP
28 AWG
Green
3
4
GND
24 AWG
Black
10
Housing
-
Shield
Blank
Housing
Description of the connector assignment of the reader (Page 24).
Connecting (SIMATIC MV320)
4.2 Connector assignment USB and RS-232 cable
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 23
RS -232 cable
Example with connector assignments
:
Figure 4-1 RS-232 cable with pin assignment
Table 4- 2 Connector table
Connector
A
Designation
Wire
Color
Connector
B
Wire
Color
Connector
C
1 VIN 24
AWG
Red 9 24 AWG Red PIN
4 TX 28
AWG
Brown 2
5 RTS 28
AWG
Orange 8
6 RX 28
AWG
Yellow 3
7 CTS 28
AWG
Green 7
10 GND 24
AWG
Black 5 24 AWG Black RING
Housing
-
Shield
Shield
Description of the connector assignment of the reader (Page 24).
Connecting (SIMATIC MV320)
4.3 Connector assignment reader
SIMATIC MV320 / SIMATIC MV325
24 Operating Instructions, 08/2015, C79000-G8976-C352-03
4.3
Connector assignment reader
The SIMATIC MV320 has an RJ-50 connector (10P-10C). The connector assignment is as
follows:
Connector
Name/function
1
+VIN (5v)
2
USB_DM
3
USB_DP
4
RS-232 TX (output from the reader)
5
RS-232 RTS (output from the reader)
6
RS-232 RX (input to the reader)
7
RS-232 CTS (input to the reader)
8
External triggering (active-low input to the reader)
9
Free
10
GND
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 25
Commissioning
5
5.1
Inserting and removing the battery (SIMATIC MV325)
Insert the battery in the device as shown in the figure on the left. If the battery is inserted
correctly, it locks in place.
To remove the battery, push the slider (figure on the right) to unlock the battery.
Slider
Inserting the battery (figure on the left):
If the battery is inserted correctly, it locks in place.
Removing the battery (figure on the right):
Push the slider (in the direction of the arrow) and remove the battery.
5.2
Charging the reader (SIMATIC MV325)
Charge the batteries before turning on the device for the first time
In the delivery state, the batteries are approximately 50% charged. Charge the batteries
before turning on the device for the first time.
The charging time for a completely discharged battery with the charging station and the USB
cable is about 4 hours.
Commissioning
5.2 Charging the reader (SIMATIC MV325)
SIMATIC MV320 / SIMATIC MV325
26 Operating Instructions, 08/2015, C79000-G8976-C352-03
Charging the reader
1. Connect the USB cable to the USB port of the computer.
2. Remove the cover labeled "Remove Before Use".
3. Place the device in the charging station .
Charge indicator
Charging station
Commissioning
5.3 Turn the reader on
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 27
5.3
Turn the reader on
SIMATIC MV320
With USB cable
1. Plug the USB end of the cable into a USB connector on the host device.
After a few seconds, you will hear two beeps.
2. The LED goes off, indicating that the reader is ready for operation.
With RS-232 cable
1. Connect the power supply unit to an alternating current power supply.
2. Insert the power cable in the corresponding connector of the RS-232 cable.
3. Connect the RS-232 plug to the suitable serial connector of the host device.
After a few seconds, the reader generates two beeps and vibrates.
4. The LED goes off, indicating that the reader is ready for operation.
SIMATIC MV325
To turn on the device, press one of the buttons or the trigger and hold it down for 1 s.
The reader beeps, vibrates and the LEDs flash when the device is turned on and ready for
operation.
Commissioning
5.4 Establishing a Bluetooth connection (SIMATIC MV325)
SIMATIC MV320 / SIMATIC MV325
28 Operating Instructions, 08/2015, C79000-G8976-C352-03
5.4
Establishing a Bluetooth connection (SIMATIC MV325)
Note
Using the SIMATIC MV325 in an area where there is WLAN communication
If you use the SIMATIC MV325 in an area where there is WLAN communication, this may
result in interference. We therefore recommend that you select the 5
GHz frequency range
for the WLAN communication and take this into account in the radio field planning.
Establishing the connection
To establish a Bluetooth connection from the charging station with the integrated Bluetooth
modem:
1. Slide the switch for the communication mode on the bottom of the charging station to
the right in the direction of the arrow.
2. Scan in the QuickConnect code . The QuickConnect code is on the front of the
charging/Bluetooth modem station or on the external Bluetooth modem.
While the connection is being established, the symbol for a wireless connection at the
top of the reader flashes.
The blue LED on the charging station or on the Bluetooth modem also flashes while
the connection is being established. As soon as the connection has been established
successfully, the blue LED is lit permanently.
The reader beeps once and the wireless symbol is lit constantly.
Communication mode switch
Blue LED
QuickConnect code
Wireless symbol
Read confirmation
Memory symbol
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 29
Operation
6
6.1
Working with the SIMATIC MV320 reader
Without metal stand
1. Hold down the trigger button of the reader.
2. The two blue beams sent out by the reader are used for targeting.
The blue beams must be directed to the center of the barcode. The ideal read distance
between the device and barcode is approximately 10 cm.
As soon as the reader is at the optimum read distance, the barcode is read. To confirm that
the barcode was read correctly, the reader generates a beep, vibrates and a green LED
flashes.
Note
Changing factory settings
To change factory settings, scan in the appropriate code: See section
Code configurations
(Pa
ge 53).
Operation
6.1 Working with the SIMATIC MV320 reader
SIMATIC MV320 / SIMATIC MV325
30 Operating Instructions, 08/2015, C79000-G8976-C352-03
With metal stand/with stand detection
The
hardware product version 2
of the reader has stand detection.
By default, the reader automatically changes to the motion detection mode when it is placed
on the stand. In this mode, the reader is activated by holding a barcode in the scanner field.
To confirm that the barcode was read correctly, the reader generates a beep, vibrates and a
green LED flashes.
When the reader is taken off the stand, it changes to manual mode:
To read a barcode, you need to press the trigger button (see "Without metal stand").
With metal stand / without stand detection
The hardware product version
1
of the reader does not have automatic stand detection with
which barcode reading on detection of motion is activated when the reader is placed on the
stand.
To configure this hardware product version for scanning on detection of motion, scan in
the appropriate code: See section Code configurations (Page 53).
Operation
6.2 Aligning the SIMATIC MV325 reader
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 31
6.2
Aligning the SIMATIC MV325 reader
1. Press a button or the trigger button of the reader.
2. Hold down the button or trigger button.
The two blue beams sent out by the reader are used for targeting.
3. The blue beams must be directed to the center of the barcode.
If the barcode is in the viewing field of the device and at the optimum read distance
(approximately 10 cm from the device), the barcode will be read automatically.
The reader beeps and vibrates and the read confirmation LED flashes green.
Operation
6.3 Setting the communication mode (SIMATIC MV325)
SIMATIC MV320 / SIMATIC MV325
32 Operating Instructions, 08/2015, C79000-G8976-C352-03
6.3
Setting the communication mode (SIMATIC MV325)
Charging stations with an integrated Bluetooth modem are equipped with a switch for the
communication mode . With this switch, the reader can transfer data either via the
Bluetooth modem or via a cable connection.
The switch is located on the bottom of the charging station.
Data is transmitted over Bluetooth (direction of the arrow)
Data is transmitted over USB port
Switch for the communication mode
Wireless communication via Bluetooth
If you move the switch for the communication mode to the position (direction of the
arrow), the reader communicates via the Bluetooth modem.
To establish a Bluetooth link, you need to scan the "QuickConnect" code on the front of
the charging station. The scanned data is then transferred wirelessly to the host device.
Wired communication via USB port
To transfer scanned data in cable mode, you need to place the reader in the charging station
so that data can be transferred to the host device.
If a cable connection is required, move the switch for the communication mode to the
position .
For USB download mode or USB keyboard mode, you need to scan in the activation code
of the batch mode.
Operation
6.4 Communication in batch mode (SIMATIC MV325)
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 33
6.4
Communication in batch mode (SIMATIC MV325)
In batch mode, you can collect data with the reader and buffer it in the reader. Depending on
the selected batch mode, the data is not transferred to the host device until you put the
reader back in the charging station or scan the configuration code for data transmission.
You can distinguish between the following communication modes for communication in batch
mode:
Via Bluetooth
Via USB port
Depending on the required communication mode, you must move the switch on the bottom
of the charging station to the corresponding position.
Data is transmitted over Bluetooth (direction of the arrow)
Data is transmitted over USB port
Transmission of saved data via Bluetooth
Use the following procedure to enable data transmission in batch mode via Bluetooth:
1. Move the switch for the communication mode on the bottom of charging station to the
position (direction of the arrow).
2. Scan the configuration barcode of the batch mode:
Batch Mode Enable - Log Only 1)
3. Scan the "QuickConnect" code on the front of the associated charging station or the
associated Bluetooth modem.
Once you have enabled the communication mode, you can start collecting data.
To transfer the data to the host device, you must scan the configuration code "Batch Mode
Transfer All Data in Memory".
Operation
6.4 Communication in batch mode (SIMATIC MV325)
SIMATIC MV320 / SIMATIC MV325
34 Operating Instructions, 08/2015, C79000-G8976-C352-03
Transmission of the saved data via USB port
Use the following procedure to enable data transmission in batch mode via USB:
1. Move the switch for the communication mode on the bottom of charging station to the
position .
2. Scan the configuration code of the USB communication mode:
USB Keyboard Mode - Batch Mode Only 1)
3. Scan the configuration barcode of the batch mode:
Batch Mode Enable - Send and Log 1)
4. Scan the configuration barcode for automatic data transfer:
Batch Mode Auto Transfer Buffer memory On
Once you have enabled the communication mode, you can start collecting data.
To transfer the data to the host device, you must place the reader in the charging station.
The reader will start transmission of the data after 5 seconds. The delay allows the host
device to prepare itself to receive the data.
1) A list of all configuration codes, e.g. for batch mode or communication mode, is available in
the manual "SIMATIC MV325 Configuration Guide
(https://support.industry.siemens.com/cs/ww/en/ps/15161/man)".
Operation
6.5 Codes with enabled factory setting
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 35
6.5
Codes with enabled factory setting
To enable or disable the codes, scan in the relevant codes (see section Code configurations
(Page 53)).
If a reader needs to be configured for reading codes that are not included in the list:
Scan in the relevant codes in to enable them (see section Code configurations
(Page 53)).
SIMATIC MV320
The following codes are enabled in the factory settings:
Codabar
Code 39
Code 93
Code 128
Data matrix
Data Matrix Rectangle
All GS1 DataBar
Interleaved 2 of 5
MSI Plessey
PDF417
QR code
UPC/EAN/JAN
SIMATIC MV325
The following codes are enabled in the factory settings:
Aztec
Codabar
Code 39
Code 93
Code 128
Data matrix
Data Matrix Rectangle
All GS1 DataBar
Interleaved 2 of 5
PDF417
Operation
6.6 Codes with disabled factory setting
SIMATIC MV320 / SIMATIC MV325
36 Operating Instructions, 08/2015, C79000-G8976-C352-03
QR code
UPC/EAN/UPC-E
6.6
Codes with disabled factory setting
To enable or disable these codes:
Scan in the relevant codes (see section Code configurations (Page 53)).
SIMATIC MV320
The following codes are disabled in the factory settings:
Codablock F
Code 11
Code 32
Composite
Han Xin Code
Hong Kong 2 of 5
IATA 2 of 5
Matrixcode
Matrix 2 of 5
Micro PDF417
MSI Plessey
NEC 2 of 5
Pharmacode
Postal Codes
Plessey
Standard 2 of 5
Telepen
Trioptic
Operation
6.6 Codes with disabled factory setting
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 37
SIMATIC MV325
The following codes are disabled in the factory settings:
Codablock F
Code 11
Code 32
Composite
Data Matrix Inverse
Han Xin Code
Hong Kong 2 of 5
IATA 2 of 5
Matrixcode
Matrix 2 of 5
Micro PDF417
MSI Plessey
NEC 2 of 5
Pharmacode
Plessey
Postal Codes
Straight 2 of 5
Telepen
Trioptic
Operation
6.7 Enabling "Suffix - Enter"
SIMATIC MV320 / SIMATIC MV325
38 Operating Instructions, 08/2015, C79000-G8976-C352-03
6.7
Enabling "Suffix - Enter"
In the factory settings of the readers, "Suffix - Enter" is disabled.
To enable "Suffix - Enter", scan in the required configuration code:
SIMATIC MV320:
Suffix Enter (USB Keyboard Mode Only)
Suffix Carriage Return Line Feed (RS232 Mode Only)
SIMATIC MV325:
Suffix Enter (USB Keyboard Mode Only)
A list of the mentioned codes is available in the manuals "SIMATIC MV320 Configuration
guide (https://support.industry.siemens.com/cs/ww/en/ps/15160/man)" and "SIMATIC
MV325 Configuration guide (https://support.industry.siemens.com/cs/ww/en/ps/15161/man)".
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 39
Alarm, error and system messages
7
7.1
Feedback from the reader
Table 7- 1 SIMATIC MV320
Situation
LED displays on the
reader
Acoustic signal
Vibration signal
SIMATIC MV320 is turned on. Green LED flashes 1x
Successful establishment of the con-
nection between SIMATIC MV320 and
the host (by cable).
Green LED goes off
after connection
establishment
1x
Decoding attempt active. Green LED is off -- --
Decoding and data transfer successful.
Green LED flashes
1x
Configuration code successfully
decoded and processed.
Green LED flashes 2x
Configuration code successfully
decoded but not successfully
processed.
Green LED flashes 4x
Table 7- 2 SIMATIC MV325
Situation
LED displays on the
reader
Acoustic signal
Vibration signal
SIMATIC MV325 turned on
successfully.
All LEDs flash 1x
SIMATIC MV325 connected to host
successfully.
Wireless symbol
flashes
1x
SIMATIC MV325 not connected to host
successfully.
-- 3x --
Decoding and data transfer successful.
Read display flashes
1x
Decoding and data transfer not
successful.
-- 3x --
Configuration code successfully
decoded and processed.
Read display flashes 2x
Configuration code not successfully
decoded and processed.
-- 4x --
Batch mode enabled and no data
stored
Batch symbol off -- --
Batch mode enabled and data stored. Batch symbol flash-
ing
-- --
Alarm, error and system messages
7.2 Charge status displays of the battery (SIMATIC MV325)
SIMATIC MV320 / SIMATIC MV325
40 Operating Instructions, 08/2015, C79000-G8976-C352-03
Situation
LED displays on the
reader
Acoustic signal
Vibration signal
Memory for batch process full. Batch symbol flash-
es 5x per second
-- --
Batch mode enabled, data stored and
SIMATIC MV325 in sleep mode.
Batch symbol flash-
es 10x per second
-- --
7.2
Charge status displays of the battery (SIMATIC MV325)
Checking the charge status
Charge status button
Charge status displays
To find out how much battery charge remains, press the button for the charge status .
If the battery charge is less than 10%, the 1st LED flashes at short intervals.
If there is 25% or more charge remaining, the LEDs flash "ON" for 4 seconds.
Alarm, error and system messages
7.3 Batch mode display (SIMATIC MV325)
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 41
Charge status display during charging
If there is less than 10% battery charge remaining, the 1st LED flashes at short intervals
during charging.
If the battery charge is 25% or more, the LEDs flash "ON" for 4 s and "OFF" for 1 s.
Battery charge status
Charge status display
< 10%
Flashing quickly
< 25%
25 ... 50%
50 ... 75%
> 75%
7.3
Batch mode display (SIMATIC MV325)
In batch mode, the memory symbol of the SIMATIC MV325 flashes at 10 second intervals
indicating that data was stored.
If the memory is full, the memory symbol flashes 5 times per second.
To release memory space, you need to download or delete data.
If no data is stored, the memory symbol does not flash.
You will find an explanation of how to switch the SIMATIC MV325 to batch mode in
Communication in batch mode (SIMATIC MV325) (Page 33).
Wireless symbol
Read confirmation
Memory symbol
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 43
Service and maintenance
8
The reader requires little maintenance. Below, you will find several useful tips on upkeep and
maintenance.
To ensure optimum performance of the reader, the window of the reader must be clean. The
window is the colorless plastic part in the head of the reader. The reader works with CMOS
technology in much the same way as a digital camera. A dirty window could have the result
that the reader is no longer capable of reading barcodes.
If the window is dirty, clean it with a soft, non-abrasive cloth or a cosmetic wipe (without
lotion and not impregnated) and a little water.
You can also use a mild cleansing agent: Then wipe the window with a damp cloth.
Approved cleaning agents
The following products have been approved for cleaning the SIMATIC MV320:
Wipes soaked in alcohol
Clorox® disinfecting wipes
Clorox® bleach solution (10% bleach, 90% tap water)
Medical DiAirKem
Sani-Cloth® HB, Super Sani-Cloth® germicidal, Sani-Clot Plus germicidal disposable
wipes
Virex® II disinfectant cleaner
Service and maintenance
SIMATIC MV320 / SIMATIC MV325
44 Operating Instructions, 08/2015, C79000-G8976-C352-03
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 45
Technical data
9
SIMATIC MV320
6GF3320-0HT01
Memory capacity
128 MB flash ROM / 32 MB RAM
Communication Interfaces RS-232, USB 2.0 (generic, keyboard, virtual
COM port)
Field selection
Near field or wide field
Dimensions and weight
Dimensions, H x L x W in mm
140 x 70 x 50
Weight
0.110 kg
Color
Dark gray
Permitted ambient conditions
Degree of protection
IP54
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +65 °C
Humidity
5 ... 95%, no condensation
Impact resistance Resistant to being dropped repeatedly on con-
crete from a height of 1.8 m
Resistant to ambient light
Sunlight: up to 96 890 lx
Electrical data/power requirements
Reader at 5 VDC (mA)
Typical < 450 mA
Idling < 80 mA
Sleep mode < 31 mA
Decoding capability
1D codes Codabar, Code 11, Code 32, Code 39, Code 93,
Code 128, Interleaved 2 of 5, GS1 DataBar
(RSS), Hong Kong 2 of 5, Matrix 2 of 5, MSI
Plessey, NEC 2 of 5, Pharmacode, Plessey,
Straight 2 of 5, Telepen, Trioptic, UPC/EAN/JAN
Stacked 1D codes Codablock F, GS1 Composite (CC-A/CC-B/CC-
C), MicroPDF, PDF417
2D codes Aztec Code, Data Matrix, Han Xin, MaxiCode,
Micro QR Code, QR Code
Postal codes Australian, Intelligent Mail, Japan Post Group,
KIX Code, Korea Post, Planet,Postnet, Royal
Mail Group Ltd, UPU ID-tags
Technical data
SIMATIC MV320 / SIMATIC MV325
46 Operating Instructions, 08/2015, C79000-G8976-C352-03
6GF3320-0HT01
Optical data
Read field
Near field 30° x 20° (horizontal x vertical)
Wide field 50° x 33.5° (horizontal x vertical)
Read distance
Approx. 100 mm
Sensor
CMOS 1.2 megapixels (1280 x 960) gray shades
Optical resolution
Near field 960 x 640
Wide field 960 x 640
Roll angle
±60° (from front to rear)
Angle of inclination
± 60° level parallel to symbol (between sides)
Rotational tolerance
± 180°
Print contrast resolution 25% (1D codes) or 35% (2D codes) absolute
dark/light reflectance differential measured at
650 nm
Target beam
Single, blue target strip
SIMATIC MV325
6GF3325-0HT01
Memory capacity
128 MB flash ROM / 32 MB RAM
Bluetooth modem
USB 2.0 (generic, keyboard, virtual COM port)
Communications interfaces
Operating modes
Bluetooth (Class II)
Field selection
Near field or wide field
Time stamp
Interval logging
Dimensions and weight
Dimensions, H x L x W in mm
Reader 135 x 130 x 51
Charging station 60 x 115 x 83
Weight
Reader 0.171 kg
Battery 0.48 kg
Charging station with integrated Bluetooth
modem
0.153 kg
Technical data
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 47
6GF3325-0HT01
Permitted ambient conditions
Degree of protection
IP65
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +65 °C
Humidity
5 ... 95%, no condensation
Impact resistance Resistant to being dropped repeatedly on con-
crete from a height of 1.8 m
Resistant to ambient light
Sunlight: up to 96 890 lx
Electrical data/power requirements
Reader at 4.2 VDC (mA)
Typical and peak 362 mA
Idling 80 mA
Sleep mode 20 mA
Charging station with integrated Bluetooth mo-
dem at 5 VDC (mA)
Max. USB charging current 555 mA
USB trickle charge current 165 mA
Charging station with external Bluetooth modem
at 5 VDC (mA)
Max. USB charging current 514 mA
Decoding capability
1D codes Codabar, Code 11, Code 32, Code 39, Code 93,
Code 128, IATA 2 of 5, Interleaved 2 of 5,
GS1 DataBar (RSS), Hong Kong 2 of 5, Matrix 2
of 5, MSI Plessey, NEC 2 of 5, Pharmacode,
Plessey, Straight 2 of 5, Telepen, Trioptic,
UPC/EAN/JAN
Stacked 1D codes Codablock F, GS1 Composite (CC-A/CC-B/CC-
C), MicroPDF, PDF417
2D codes Aztec Code, Data Matrix, Han Xin, MaxiCode,
Micro QR Code, QR Code
Postal codes Australian, Intelligent Mail, Japan Post, KIX
Code, Korean Post, Planet, Postnet, UK Royal
Mail, UPU ID-tags
Optical data
Read field
Near field 30° horizontal by 20° vertical
Wide field 50° horizontal by 33.5° vertical
Read distance
Approx. 100 mm
Sensor
CMOS 1.2 megapixels (1280 x 960) gray shades
Technical data
SIMATIC MV320 / SIMATIC MV325
48 Operating Instructions, 08/2015, C79000-G8976-C352-03
6GF3325-0HT01
Optical resolution
Near field 960 x 640
Wide field 960 x 640
Roll angle
±60° (from front to rear)
Angle of inclination
± 60° level parallel to symbol (from side to side)
Rotational tolerance
± 180°
Print contrast resolution 25% (1D codes) or 35% (2D codes) absolute
dark/light reflectance differential measured at
650 nm
Target beam
Single, blue target strip
Number of scanning operations
Up to 50 000 scans/charge
Read distances
The read distances are made up of a wide field and a near field.
All code patterns must be of high quality and on a physical midline at an angle of 1
when read.
The table refers to the AGC factory settings; accuracy: ± 10 %
Table 9- 1 Read distances
Test code
Min. mm
Max. mm
3 mil Code 39
80
102
7.5 mil Code 39
33
182
10.5 mil GS1 DataBar
20
220
13 mil UPC
28
280
4.2 mil Data Matrix
48
110
5 mil Data Matrix
43
115
6.3 mil Data Matrix
33
150
10 mil Data Matrix
20
180
20.8 mil Data Matrix
28
343
1 mil = 0.0254 mm
The ideal read distance is about 100 mm. Depending on the code type and code size,
smaller or larger distances are possible.
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 49
Dimension drawings
10
All dimensions in mm
Figure 10-1 SIMATIC MV320 dimension drawing
Dimension drawings
SIMATIC MV320 / SIMATIC MV325
50 Operating Instructions, 08/2015, C79000-G8976-C352-03
Figure 10-2 SIMATIC MV325 dimension drawing
Figure 10-3 SIMATIC MV325 charging station dimension drawing
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 51
Ordering data
11
Table 11- 1 SIMATIC MV320 / SIMATIC MV325 ordering data
Article number
SIMATIC MV320
Handheld reader
6GF3320-0HT01
SIMATIC MV325
Handheld reader with battery, charging station and USB cable
(0.9 m)
6GF3325-0HT01
Table 11- 2 SIMATIC MV320 accessories ordering data
Article number
Power supply unit 1)
EU
6GF3020-0AC40-0AP2
USA
6GF3020-0AC40-0AP1
Power supply unit
2)
EU
6GF3320-0AC04
USB cable (1.8 m) 6GF3320-0AC02
RS-232 cable, coiled (2.4 m)
6GF3320-0AC03
Metal stand
6GF3320-0AC07
1)
Delivery possible until 10/2015
2) Delivery possible from 10/2015
Table 11- 3 SIMATIC MV325 accessories ordering data
Article number
Charging station with USB interface
Bluetooth wireless interface and USB cable (0.9 m)
6GF3325-0AC03
Battery
lithium-ion 1 300 mAh, 50 000 charging cycles
6GF3325-0AC07
Bluetooth M3 modem
1)
6GF3325-0AC05
RS-232 cable, coiled (2.4 m)
1)
6GF3325-0AC06
1) Delivery possible from 10/2015
Ordering data
SIMATIC MV320 / SIMATIC MV325
52 Operating Instructions, 08/2015, C79000-G8976-C352-03
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 53
Appendix
A
A.1
Code configurations
Note
Changing the configuration
Changes to the configuration take effect immediately and are stored.
Note
Rate of data transmission depends on set keyboard
Note that the data transmission rate is slower with a set universal keyboard (Universal
Keyboard Mapping) than with selection of a specific keyboard language (e.g. US keyboard).
SIMATIC MV320
Codes for configuration of the device
A current list of the codes for configuration of the SIMATIC MV320 reader is available at the
following link:
SIMATIC MV320 Configuration guide
(https://support.industry.siemens.com/cs/ww/en/ps/15160/man)
Motion detection with the reader with and without stand detection
If the reader is placed on a stand, the reader with stand detection automatically switches to
the motion detection mode.
When the code for "Disable Motion Detection with Stand Detection" is scanned in, the
reader switches to the motion detection mode. Detection depends on whether or not the
reader is on a stand.
To disable motion detection, you need to scan in the code for "Disable Motion Detection
with Stand Detection" and "Motion Detection Scanning Off".
To enable motion detection on readers with stand detection after disabling motion
detection:
You need to scan in the code for "Enable Motion Detection with Stand Detection"
To enable motion detection on readers without stand detection:
You need to scan in the required code for "Motion Detection On".
Appendix
A.2 "Specify character length to be read" function
SIMATIC MV320 / SIMATIC MV325
54 Operating Instructions, 08/2015, C79000-G8976-C352-03
SIMATIC MV325
A current list of the codes for configuration of the SIMATIC MV325 reader is available at the
following link:
SIMATIC MV325 Configuration guide
(https://support.industry.siemens.com/cs/ww/en/ps/15161/man)
A.2
"Specify character length to be read" function
Description of the function
With the help of this function, you can specify the code character length to be read by the
SIMATIC MV320 and SIMATIC MV325 handheld readers. When you enable this function,
the handheld readers will only read codes that have exactly the character length you have
specified.
This function is particularly useful when multiple codes with different character lengths are
printed on the product that is to be scanned.
Enabling/disabling the function
Enable
Follow these steps to enable the function:
1. Scan the following code to enable the function:
2. Scan the following code to restart the handheld reader:
Appendix
A.2 "Specify character length to be read" function
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 55
3. For SIMATIC MV325:
Scan the "QuickConnectCode" on the charging station.
4. Scan the required character length code with which you specify which codes with which
character length are to be read.
The table below contains the character length codes.
Disable
Follow these steps to disable the function:
1. Scan the device-specific reset code:
MV320:
MV325:
When the reset code is scanned, the handheld reader is reset to the factory settings and
restarted.
Appendix
A.2 "Specify character length to be read" function
SIMATIC MV320 / SIMATIC MV325
56 Operating Instructions, 08/2015, C79000-G8976-C352-03
Character length codes
The table below contains the codes with which you can specify the permitted character
length as described in step 4 above.
Table A- 1 Character length codes
1 character
2 characters
3 characters
4 characters
5 characters
6 characters
7 characters
8 characters
9 characters
10 characters
11 characters
12 characters
13 characters
14 characters
15 characters
16 characters
17 characters
18 characters
19 characters
20 characters
21 characters
22 characters
23 characters
24 characters
Appendix
A.3 Service and Support
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 57
A.3
Service and Support
Technical Support
You can contact Technical Support for all Process Industries and Drives products as follows:
Phone: + 49 (0) 911 895 7222
Fax: + 49 (0) 911 895 7223
E-mail (mailto:support.automation@siemens.com)
Internet: Online support request form:
(https://support.industry.siemens.com/My/ww/en/requests)
Contact partner
If you have any further questions on the use of our products, please contact one of our
representatives at your local Siemens office.
The addresses are found on the following pages:
On the Internet (http://w3.siemens.com/aspa_app)
In Catalog CA 01
In the catalog ID 10 for Industrial identification systems
Service and Support at Process Industries and Drives (PD)
You will find various services on the Support homepage
(https://support.industry.siemens.com/cs/de/en/) of PD on the Internet.
There you will find the following information, for example:
Our newsletter containing up-to-date information on your products.
Relevant documentation for your application, which you can access via the search
function in "Product Support".
A forum for global information exchange by users and specialists.
Your local PD representative.
Information about on-site service, repairs, spare parts, and much more can be found
under "Our service offer".
SIMATIC Ident home page
For the latest general information about our identification systems, visit us on the Internet at
Identification systems home page (http://w3.siemens.com/mcms/identification-systems/).
Appendix
A.3 Service and Support
SIMATIC MV320 / SIMATIC MV325
58 Operating Instructions, 08/2015, C79000-G8976-C352-03
SIMATIC documentation on the Internet
A guide to the technical documentation for the various SIMATIC products and systems is
available on the Internet:
SIMATIC Guide manuals (http://www.siemens.com/simatic-tech-doku-portal)
Online catalog and ordering system
The online catalog and the online ordering system can also be found on the Industry Mall
home page (https://mall.industry.siemens.com).
Training center
We offer appropriate courses to get you started. Please contact your local training center or
the central training center in
D-90327 Nuremberg.
Phone: +49 (0) 180 523 56 11
(€ 0.14 /min. from the German landline network, deviating mobile communications prices are
possible)
For information about courses, see the SITRAIN homepage
(http://sitrain.automation.siemens.com/sitrainworld/).
Appendix
A.4 Certificates and approvals
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 59
A.4
Certificates and approvals
According to the conditions of the guarantee, the product guarantee becomes void if the
housing is opened or handled improperly.
SIMATIC MV320
CE marking
Description
Conformity with EMC directive.
FCC standard
Description
FCC CFR 47 Part15-Digital Devices, Subpart B-Unintentional Radiators, Class B (Octo-
ber 1st 2011).
This device is equivalent to the CR1400-Handheld from CodeCorp.
SIMATIC MV325 (reader and charging station)
CE marking
Description
Conformity with the R&TTE directive.
Appendix
A.4 Certificates and approvals
SIMATIC MV320 / SIMATIC MV325
60 Operating Instructions, 08/2015, C79000-G8976-C352-03
FCC standard
Description
FCC CFR 47, Part 15 Digital Devices, Subpart C, sections 15.203, 15.207, and 15.247
Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
The device MV325 (6GF3325-0HT01) is equivalent to the CR2612_01 and CR2612_02
devices from CodeCorp.
FCC ID: QQ6-BTR11 (CR2612_01 from FS: A1)
FCC ID: QQ6-BTR12 (CR2612_02 from FS: B1)
The device MV325 CHARGING STATION (6GF3325-0AC03) is equivalent to the CRA-
A104_02 device from CodeCorp.
FCC ID: QQ6-BTC02 (CRA-A104_02 from FS: A1)
Industry Canada Radio
Standards Specifications
RSS-210 Issue 8, December 2010
The device MV325 (6GF3325-0HT01) is equivalent to the CR2612_01 and CR2612_02
devices from CodeCorp.
IC: 9966A-BTR11 (CR2612_01 from FS: A1)
IC: 9966A-BTR12 (CR2612_02 from FS: B1)
The device MV325 CHARGING STATION (6GF3325-0AC03) is equivalent to the CRA-
A104_02 device from CodeCorp.
IC: 9966A-BTC02 (CRA-A104_02 from FS: A1)
Appendix
A.4 Certificates and approvals
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 61
A.4.1
FCC information
Siemens SIMATIC MV325 (reader)
FCC ID: QQ6-BTR11 (CR2612_01 from FS: A1)
FCC ID: QQ6-BTR12 (CR2612_02 from FS: B1)
Siemens SIMATIC MV325 (charging station)
FCC ID: QQ6-BTC02 (CRA-A104_02 from FS: A1)
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Important Note
To comply with FCC RF exposure compliance requirements, this device must not be co-
located or operate in conjunction with any other antenna or transmitter.
Caution
Changes or modifications not expressly approved by the party responsible for compliance
could void the users authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Appendix
A.4 Certificates and approvals
SIMATIC MV320 / SIMATIC MV325
62 Operating Instructions, 08/2015, C79000-G8976-C352-03
A.4.2
IC-FCB information
Siemens SIMATIC MV325 (reader)
IC: 9966A-BTR11 (CR2612_01 from FS: A1)
IC: 9966A-BTR12 (CR2612_02 from FS: B1)
Siemens SIMATIC MV325 (charging station)
IC: 9966A-BTC02 (CRA-A104_02 from FS: A1)
This Class B digital apparatus complies with
Canadian ICES
-003.
This device complies with Industry Canada
licence
-exempt RSS standard(s).
Operation is subject to the following two co
n-
ditions:
(1) this device may not cau
se interference,
and
(2) this device must accept any interference,
including interference that may cause und
e-
s
ired operation of the device.
Cet appareil numérique de la classe B est
conforme à la norme NMB
-003 du Canada.
Le pré
sent appareil est conforme aux CNR
d
Industrie Canada applicables aux appareils
radio exempts de licence.
L
exploitation est autorisée aux deux condi-
t
ions suivantes :
(1) l
appareil ne doit pas produire de brouil-
lage, et
(2) l
utilisateur de lappareil doit accepter tout
brouillage radioélectrique subi, même si le
brouillage est susceptible d
en compromettre
le fonctionnement.
SIMATIC MV320 / SIMATIC MV325
Operating Instructions, 08/2015, C79000-G8976-C352-03 63
Index
C
CE marking, 59, 59
Charging batteries, 25
Cleaning agents, 43
Codes
Enabling/disabling, 35
Contact partner, 57
Courses, 58
D
Disposal, 9
E
Environmental protection, 4
F
FCC standard, 59, 60
I
Industry Canada Radio Standards Specifications, 60
O
Operating instructions on the Internet, 4
R
REACH
Registration, Evaluation, Authorisation and
Restriction of Chemicals, 21
Read distance (SIMATIC MV325)
Optimum, 31
Read distances, 48
Recycling, 4
RoHS
Restriction of (the use of certain) Hazardous
Substances, 21
S
Scope
for devices, 3
SIMATIC documentation
On the Internet, 58
SIMATIC MV320
Area of application, 12
Features, 12
SIMATIC MV325
Area of application, 13
Features, 13
T
Technical Support, 57
Training, 58
U
Use in an area where there is WLAN
communication, 28
W
WLAN communication
Selecting the frequency range, 28
Use in an area with, 28
Index
SIMATIC MV320 / SIMATIC MV325