http://www.tracopower.com Page 2 of 12
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Open Frame Power Supplies
TOL Series 10–300 Watt
Input Specifications
Input voltage range 85 – 264 VAC
Input frequency 47 – 63 Hz
Recommended circuit breaker 10 – 150 Watt models: 6 A
(characteristic C) or slow blow fuse 300 Watt models: 10 A
Output Specifications
Output voltage adjustment range ±10 %
Regulation – Input variation 0.5 % max.
– Load variation (10–100%) 0.8 % max.
Ripple and noise (20 Mhz Bandwidth) 5 VDC output models: 100 mV pp max.
12/24 VDC output models: 180 mV pp max.
48 VDC output models: 300 mV pp max. (TOL 300: 600 mV pp max)
Output current limitation (except for F versions) 105 % – 140 % of Inom.
Short circuit protection – 10 to 30 Watt models: hiccup mode, indefinite (automatic recovery)
– 50 to 300 Watt models: constant current (automatic recovery)
Overvoltage protection 115 – 135 % Vout nom.
Capacitive load – TOL 10 10’000 µF max. (24 Vout model: 2’000 µF)
– TOL 15 15’000 µF max. (24 Vout model: 6’000 µF)
– other models 18’000 µF max.
General Specifications
Temperature ranges – Operating temperature –10°C to +60°C (TOL 150: –10°C to +50°C)
– Derating above +50°C 3 %/K (TOL 150: 1.5 %/°C above 35°C)
– Storage (non operating) –20°C to +70°C
Temperature coefficient 0.02 %/K
Efficiency 75 % typ.
Humidity (non condensing) 20 % – 90 % rel. H
Switching frequency 100 kHz typ. (PWM)
Hold-up time 20 ms typ. at full load
Isolation voltage – Input / output 3‘000 VAC for 1min.
– Input / FG (or case) 2’000 VAC for 1min.
– Output / FG (or case) 500 VDC for 1min.
Isolation resistance 100 MOhm
Leakage current 0.6 mA RMS typ. / 230 VAC / 60 Hz
Electromagnetic compatibility – Conducted input RI suppression EN 55022, class B; FCC Part 15, level B
(EMC) Emission – Harmonic current emissions IEC/EN 61000-3-2, class D
Electromagnetic compatibility – Electrostatic discharge IEC/EN 61000-4-2 8kV / 15kV
(EMC) Immunity – Surge immunity IEC/EN 61000-4-5 2kV / 4kV
Environmental compliance – Reach www.tracopower.com/products/tol-reach.pdf
– RoHS RoHS directive 2002/95/EC