https://www.phoenixcontact.com/us/products/2908206 Surge protection device-TTC-6P-2X1-F-12DC-PT-I-2908206 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge protection, consisting of protective plug and base element, with integrated status indicator for two signal wires with common reference potential, e.g., Digital IN/OUT. Indirect grounding via gas-filled surge arrester. Your advantages Space-saving and cost-saving with a narrow overall width of just 6mm Continuous monitoring of protective devices, plus mechanical status indicator with optional remote signaling Finding the right product for all possible requirements in MCR applications is easy, thanks to the complete range of products with customized features Easy testing and documentation with CHECKMASTER2 with pluggable protective modules The signal is not influenced during maintenance work, thanks to the impedance-neutral insertion and removal of protective plugs Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626282909 Weight per Piece (excluding packing) 40.000 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 105.8 mm Width 6.2 mm +0.1mm Depth 100 mm (incl. DIN rail 7.5mm) 01/03/2021Page1/8 https://www.phoenixcontact.com/us/products/2908206 Surge protection device-TTC-6P-2X1-F-12DC-PT-I-2908206 Technical data Ambient conditions Ambient temperature (operation) -40 C ... 85 C Ambient temperature (storage/transport) -40 C ... 85 C Permissible humidity (operation) 5 % ... 95 % Altitude 4000 m (amsl (above mean sea level)) Degree of protection IP20 General Housing material PBT Flammability rating according to UL 94 V-0 Color traffic grey A RAL 7042 light grey RAL 7035 Mounting type DIN rail: TH 35 - 7.5 mm Type DIN rail module, two-section, divisible Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/ShieldEarth Ground Protective circuit IEC test classification C1 C2 C3 D1 Nominal voltage UN 12 VDC Maximum continuous voltage UC 15 VDC 10 VAC Rated current 600 mA (56 C) Operating effective current IC at UC 100 A Residual current IPE 1 A Nominal discharge current In (8/20) s (line-earth) 5 kA Nominal discharge current In (8/20) s (line-signal ground) 5 kA Pulse discharge current Iimp (10/350)s (line-earth) 0.5 kA Pulse discharge current Iimp (10/350)s (line-signalground) 0.5 kA Total discharge current Itotal (8/20)s 10 kA Voltage protection level Up (line-earth) 750 V (C1 - 1 kV/500 A) 750 V (C2 - 10 kV / 5 kA) 1.2 kV (C3 - 25 A) 1.3 kV (C3 - 100 A) Voltage protection level Up (line-signalground) 145 V (C1 - 1 kV/500 A) 285 V (C2 - 10 kV / 5 kA) 01/03/2021Page2/8 https://www.phoenixcontact.com/us/products/2908206 Surge protection device-TTC-6P-2X1-F-12DC-PT-I-2908206 Technical data Protective circuit 25 V (C3 - 25 A) 30 V (C3 - 100 A) Voltage protection level Up static (line-earth) 750 V (C1 - 1 kV/500 A) 750 V (C2 - 10 kV / 5 kA) Voltage protection level Up static (line-signalground) 35 V (C1 - 1 kV/500 A) 105 V (C2 - 10 kV / 5 kA) Response time tA (line-signalground) 1 ns Response time tA (line-earth) 100 ns Input attenuation aE, asym. typ. 0.3 dB ( 140 kHz / 150 ) Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system typ. 440 kHz Capacity (line-signalground) typ. 5.2 nF Resistance per path 1.65 20% Max. required back-up fuse 630 mA (FF) Impulse durability (line-earth) C1 - 1kV / 500A C2 - 10kV / 5kA C3 - 100A D1 - 500A Impulse durability (line-signalground) C1 - 1kV / 500A C2 - 10kV / 5kA C3 - 100 A D1 - 500A Pulse reset time (line-earth) 30ms Pulse reset time (line-signalground) 30ms Additional technical data Max. total discharge current I total max (8/20)s 20 kA (1x) Connection data Connection method Push-in connection Stripping length 8 mm Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section solid 0.2 mm ... 4 mm Conductor cross section AWG 24 ... 12 Standards and Regulations Standards/specifications IEC61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 EN61643-21 2001 + A1:2009 + A2:2013 Environmental Product Compliance 01/03/2021Page3/8 https://www.phoenixcontact.com/us/products/2908206 Surge protection device-TTC-6P-2X1-F-12DC-PT-I-2908206 Technical data Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Pictogram Diagram 800 I [mA] U 600 400 200 40 50 60 70 80 T [C] Dimensional drawing 105,8 90 Circuit diagram 6,2 1 4 2 5 3 6 protected 92,5 100 unprotected ! Classifications eCl@ss eCl@ss 10.0.1 27130807 eCl@ss 11.0 27130807 eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130800 eCl@ss 7.0 27130807 eCl@ss 8.0 27130807 eCl@ss 9.0 27130807 01/03/2021Page4/8 https://www.phoenixcontact.com/us/products/2908206 Surge protection device-TTC-6P-2X1-F-12DC-PT-I-2908206 Classifications ETIM ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 5.0 EC000943 ETIM 6.0 EC000943 ETIM 7.0 EC000943 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 UNSPSC 18.0 39121620 UNSPSC 19.0 39121620 UNSPSC 20.0 39121620 UNSPSC 21.0 39121620 Approvals Approvals Approvals DNV GL / CSA / UL Listed / CSAus / cCSAus Ex Approvals Approval details DNV GL https://approvalfinder.dnvgl.com/ TAE000027G CSA http://www.csagroup.org/services-industries/product-listing/ 70136717 01/03/2021Page5/8 https://www.phoenixcontact.com/us/products/2908206 Surge protection device-TTC-6P-2X1-F-12DC-PT-I-2908206 Approvals UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 138168 CSAus http://www.csagroup.org/services-industries/product-listing/ 70136717 cCSAus Accessories Accessories End block End clamp-CLIPFIX 35-5-3022276 Quick mounting end clamp for NS 35/7,5 DIN rail or NS 35/15 DIN rail, with marking option, with parking option for FBS...5, FBS...6, KSS 5, KSS 6, width: 5.15 mm, color: gray Labeled terminal marker Zack Marker strip, flat-ZBF 6 CUS-0825027 Zack Marker strip, flat, Strip, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap into flat marker groove, for terminal block width: 6.2 mm, lettering field size: 5.15 x 6.15 mm, Number of individual labels: 10 Zack Marker strip, flat-ZBF 6,QR:FORTL.ZAHLEN-0808765 Zack Marker strip, flat, Strip, white, labeled, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 91 ... 100, mounting type: snap into flat marker groove, for terminal block width: 6.2 mm, lettering field size: 5.15 x 6.15 mm, Number of individual labels: 10 01/03/2021Page6/8 https://www.phoenixcontact.com/us/products/2908206 Surge protection device-TTC-6P-2X1-F-12DC-PT-I-2908206 Accessories Marker pen Marker pen-X-PEN 0,35-0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm Terminal marking Zack Marker strip, flat-ZBF 6:UNBEDRUCKT-0808710 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 6.2 mm, lettering field size: 5.15 x 6.15 mm, Number of individual labels: 10 Zack Marker strip, flat-ZBF 6/WH-100:UNBEDRUCKT-0808736 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 6.2 mm, lettering field size: 5.15 x 6.15 mm, Number of individual labels: 10 Additional products Remote signaling set-TTC-6-FMRS-PT-2907811 Module set for the optical monitoring and floating remote signaling of adjacent surge protective devices in the TERMITRABcomplete or CLIXTRAB product family. Suitable for directly grounded DIN rails. 01/03/2021Page7/8 https://www.phoenixcontact.com/us/products/2908206 Surge protection device-TTC-6P-2X1-F-12DC-PT-I-2908206 Accessories Shield connection-SSA 3-6-2839295 Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm, color: black Shield connection-SSA 5-10-2839512 Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm, color: black Spare parts Surge protection plug-TTC-6P-2X1-12DC-I-P-2907842 Surge protection plug with integrated status indicator on the module for two signal wires with a common reference potential. Nominal voltage: 12V DC Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 01/03/2021Page8/8