No more writing data down. Capture up to 65000
sets of min/max/avg readings over single or multiple
logging sessions using the recording capability.
Each reading and session is time stamped
Avoid awkward or uncomfortable measurement
positions. Set up the measurement once, step
back and read it as many times as you want, when
you want
Identify up to 10 placed modules with meter or PC
and choose only the ones you need
View up to 10 live readings at once on a PC to get a
complete understanding of the situation
Easily see backlit displays in dark or dimly lit work
environments
Choose auto or manual ranging
Use the optional TPak magnetic hanger for even
more hands-free working
Integrated holster protects the meters, while probe
holders keep accessories organized
Safety
Increase safety by taking readings in a separate
location than the point of measurement
Fluke CNX meets Measurement Category 1000 V
CAT III and Category IV 600 V safety standards: AC
current clamp 600 V CAT III; AC Voltage Module and
iFlex Clamp Meters 600 V CAT IV / 1000 CAT III
Fluke CNX 3000
Series Test Tools
The Fluke Wireless Team
The new Fluke wireless troubleshooting
team lets you see live measurements
from multiple modules simultaneously
and remotely on a single screen. This
customizable tool set, built with the
durability, reliability and quality you’ve come
to expect from Fluke tools, will change the
way you work.
Wireless multimeter displays readings
from up to three wireless modules, plus
the meter from up to 20 meters away. Add
a laptop and review ten measurements at
once.
Fluke CNX 3000 Series
Digital Multimeter
AC Voltage Module
AC True-rms Current Clamp Module
iFlex True-rms AC Current Clamp Module
K-Type Temperature Module
PC Adapter
Productivity
Save money and time by taking multiple measure-
ments simultaneously
Isolate intermittent events or record signal fluc-
tuations without even being there using the log
function on the modules
Work with fewer interruptions by recording multiple
sessions before downloading. Data is saved to a PC
in .csv format (comma separated variable) file format
for easy viewing at your convenience
Capture readings at different intervals, with user-set
recording intervals from one second to one hour
Choose the module(s) that work best for your
applications
Convenience
No more run-around. See up to four measurements
(DMM and 3 modules) on one screen, in one place
at the same time.
Technical Data
2 Fluke Corporation Fluke CNX 3000 Series Test Tools. The Fluke Wireless Team.
Fluke CNX 3000 Series Wireless Multimeter
Detailed specifications
For all specifications: accuracy is specified for one year after calibration, at operating tem-
peratures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications
take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
AC voltage
Range1Resolution
Accuracy2,3
45Hz to 500Hz 500Hz to 1kHz
600.0mV 0.1mV
1.0% + 3 2.0% + 3
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
1000V 1V
1 All ac voltage ranges are specified from 1% of range to 100% of range.
2 Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor < 1.5 at 1000V.
3 For non-sinusoidial waveforms, add –(2% of reading + 2% full scale) typical, for crest factor up to 3.
DC voltage, continuity, resistance, diode test and capacitance
Function Range Resolution Accuracy
mV 600.0mV 0.1mV 0.09% + 2
V 6.000V 0.001V
0.09% + 260.00V 0.01V
600.0V 0.1V
1000V 1V 0.15% + 2
600Ω 1Ω Meter beeps at < 25Ω, beeper detects opens or shorts
of 250μs or longer.
600.0Ω 0.1Ω 0.5% + 2
6.000kΩ 0.001kΩ
0.5% + 1
60.00kΩ 0.01kΩ
60.00kΩ 0.1kΩ
600.0kΩ 0.001MΩ
50.00MΩ 0.01MΩ 1.5% + 3
Diode test 2.000V 0.001V 1% + 2
µF 1000nF 1nF
1.2% + 210.00μF 0.01μF
100.0μF 0.1μF
9999μF11μF 10% typical
1 In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2.
AC and DC current
Function Range1Resolution Accuracy
mA AC (45Hz to 1kHZ) 60.00mA 0.01mA 1.5% + 3
400.0mA30.1mA
mA DC260.00mA 0.01mA 0.5% + 3
400.0mA 0.1mA
1 All ac current ranges are specified from 5% of range to 100% of range.
2 Input burden voltage (typical): 400mA input 2mV/mA.
3 400.0 mA accuracy specified up to 600mA overload.
Specifications
Contents
3 Fluke Corporation Fluke CNX 3000 Series Test Tools. The Fluke Wireless Team.
Frequency
Range Resolution Accuracy [1]
99.99Hz 0.01Hz
0.1% + 1
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99kHz 0.01kHz
1 Frequency is specified up to 99.99kHz in volts and up to 10kHz in amps.
Input characteristics
Function
Overload
Protection
Input Impedance
(nominal) Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V rms > 10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V rms > 10 MΩ < 100 pF > 60 dB, dc to 60 Hz
1100 V rms > 10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale voltage Typical short circuit current
To 6 MΩ 50 MΩ
1100 V rms < 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 mA
1100 V rms < 2.7 V dc 2.000 V dc < 1.1 mA
Function Overload Protection Overload
mA Fused, 44/100A, 1000V FAST Fuse 600mA overload for 2minutes maximum, 10minutes rest minimum
MIN/MAX recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General specifications
Maximum voltage between any
terminal and earth ground
1000 V dc or ac rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range 20meters
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35°C to 40°C), 0% to 45% (40°C to 50°C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Electromagnetic compatibilty
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249,
FCCID : T68-FWCS IC:6627A-FWCS
Safety compliance US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
4 Fluke Corporation Fluke CNX 3000 Series Test Tools. The Fluke Wireless Team.
Fluke CNX 3000 Series AC Voltage Module
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges
are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by
autoranging, from 18 °C to 28 °C.
AC voltage
Range1Resolution Accuracy2,3
45Hz to 500Hz 500Hz to 1kHz
6.000V 0.001V
1.0% + 3 2.0% + 3
60.00V 0.01V
600.0V 0.1V
1000V 1V
1 All ac voltage ranges are specified from 1% of range to 100% of range.
2 Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor ≤ 1.5 at 1000V.
3 For non-sinusoidial waveforms, add –(2% of reading + 2% full scale) typical, for crest factor up to 3.
General specifications
LCD w/backlight 3½ digits, 6000 counts, updates 4/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 400 Hours
Memory Record up to 65000 readings
RF communications 2.4 GHZ ISM Band
RF communication range 20meters
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient 0.1X (specified accuracy)/°C (< 18°C or > 28°C)
Operating humidity 90% at 35°C, 45% at 40°C, 45% at 50°C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42
Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Contents
5 Fluke Corporation Fluke CNX 3000 Series Test Tools. The Fluke Wireless Team.
Fluke CNX 3000 Series
True-rms AC Current Clamp Module
General specifications
Range 0.5 A to 400.0 A
Resolution 0.1A
Accuracy 400.0 A: 2% ± 5 digits (10Hz to 100Hz), 2.5% ± 5 digits (100Hz
to 500Hz)
Inrush Max displayed reading: 999.9A
Crest factor (50Hz/60Hz) 3 at 500A, 2.5 at 600A, 1.42 at 1000A, add 2% for C.F. > 2
LCD w/backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range 20meters
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1x (specified accuracy)/°C (< 18°C or > 28°C)
Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1-030:2010 to 600 V Measurement Category (CAT) III
EN/IEC 61010-2-030:2010
EN/IEC 61010-032:2002
Safety rating CAT III 600 V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP30
Jaw opening 34 mm (1.33 in)
Size (HxWxD) 20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)
Weight .22 kg (8 oz)
6 Fluke Corporation Fluke CNX 3000 Series Test Tools. The Fluke Wireless Team.
Fluke CNX 3000 Series
iFlex True-rms AC Current Clamp Module
General specifications
Range 0.5 A to 2500 A AC
Resolution 0.1 A
Accuracy 3% ± 5 digits
Crest factor (50Hz/60Hz) 3.0 at 1100A, 2.5 at 1400A, 1.42 at 2500A, add 2% for C.F. > 2
LCD w/backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range 20meters
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1X (specified accuracy)/ °C (<18°C or >28°C)
Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42
Jaw opening 25.4 cm (10 in) coil
Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
7 Fluke Corporation Fluke CNX 3000 Series Test Tools. The Fluke Wireless Team.
Fluke CNX 3000 Series
K-Type Temperature Module
General specifications
Range K-type: -200°C to 1372°C
Resolution 0.1°C
Accuracy ± [0.5% + 0.3°C] counts
Input terminals K-type mini
LCD w/backlight 3 ½ digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range 20meters
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient 0.01% of reading +0.03°C per °C
Temperature scale ITS-90
Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C
EMC EN 61326-1:2006
Safety compliance CAT I per IEC/EN 61010-1:2010, EN/IEC 61010-2-030:2010
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP30
Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2012 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 9/2012 4237028B_EN
Modification of this document is not permitted
without written permission from Fluke Corporation.
Fluke. The Most Trusted Tools
in the World.
Ordering information
Models Description
Kits
FLK-CNX Industrial Kit Fluke CNX 3000 Industrial System includes Multimeter, 3 iFlex Clamp
Modules, 1 Voltage Module and accessories
FLK-CNX 3000 General
Maintenance Kit
Fluke CNX 3000 General Maintenance System includes Multimeter,
iFlex Clamp Module, Voltage Module and accessories
FLK-CNX 3000 HVAC Kit Fluke CNX 3000 HVAC Kit System includes Multimeter, AC Current
Clamp Module, Temperature Module and accessories
FLK-CNX T3000 Kit Fluke CNX T3000 Kit includes Multimeter, Temperature Module and
accessories
FLK-CNX I3000 Kit Fluke CNX I3000 Kit includes Multimeter, iFlex Clamp Module and
accessories
FLK-CNX A3000 Kit Fluke CNX A3000 Kit includes Multimeter, AC Current Clamp Module
and accessories
FLK-CNX V3000 Kit Fluke CNX V3000 Kit includes Multimeter, Voltage Module and
accessories
Modules
FLK-CNX 3000 Series Digi-
tal Multimeter
FLK-CNX 3000 Digital Multimeter and accessories
FLK-CNX 3000 Series iFlex
AC Current Clamp Module
FLK-CNX 3000 iFlex Module and iFlex Clamp
FLK-CNX 3000 Series AC
Current Clamp Module
FLK-CNX 3000 AC Current Clamp Module
FLK-CNX 3000 Series AC
Voltage Module
FLK-CNX 3000 AC Voltage Module and accessories
FLK-CNX 3000 Series
K-Type Temperature Module
FLK-CNX 3000 K-Type Temperature Module and accessory