PREPARED
DATE
P.S.
REV.
Y
AA1282US-AT
A
AC FAN (RoHS)
研發處
吳靜心
2011.08.05
2011.08.05
發行章
卓振強
2011.08.05
2011.08.05
D A T A - S H E E T
Engineering
11/08/05
BRUSHLESS AXIAL COOLING FANS
Customer Ref: (RoHS)
Adda Model No AA1282US-AT
Samples attached Piece(s),
Safety Approval UL,CUL,TUV, CE
Specifications
ITEM SPECIFICATION / CONDITION
DIMENSIONS
mm
BEARING TYPE
SLEEVE
RATED VOLTAGE
230 VAC
OPERATING VOLTAGE RANGE
220 VAC 240 VAC
  OPERATIONG FREQUENCY 50 / 60 Hz
REAL CURRENT
0.140 / 0.120 Amp
REAL POWER
17.50 / 19.80 Watt
RATED CURRENT 0.170 / 0.130 Amp + 10%
RATED POWER
21.30 / 21.50 Watt
RATED SPEED
2400 / 2600 RPM ±10%
AIR FLOW
96.000 / 107.000 CFM (min: 86.400 / 96.300 CFM)
AIR FLOW
2.716 / 3.028 CMM (min: 2.444 / 2.725 CMM)
/ (min at zero air flow.)
STATIC AIR PRESSURE
0.240 / 0.250 Inch H2O(min: 0.194 / 0.202 Inch H2O)
STATIC AIR PRESSURE
6.096 / 6.350 mm H2O(min: 4.937 / 5.143 mm H2O)
/
NOISE LEVEL
46.4 / 48.1 dB(A) (max.: 50.4 / 52.1 dB(A))
MOTOR PROTECTION
Impedance Protect
LIFE EXPECTANCY
30000 Hours at 25/ 65% RH
NET WEIGHT
550 Gram.
PACKING
40 pcs. Per Export Carton.
120x120x38.5
Printed On:
Page 1/4ADDA CORPORATION Model No.: AA1282US-AT
TUV:EN60335-1:2002+A1+A11+A12
EN60335-2-80:2003+A1
UL:UL 507
CE:EN 55014-1:2006
EN 55014-2:1997+A1
EN 61000-3-2:2006
EN 61000-3-3:1995+A1+A2
Unless otherwise stated, the relative humidity is 65%, and the temperature is 25oC
for the standard testing.
Should you have any doubt, please refer to the environmental conditions specified in the
acknowledgement document.
2011.08.05
SPECIFICATION
Page 2/4ADDA CORPORATION AC FAN SERIES
10 Scope This documentation defines the mechanical & electrical charcterists
of AC brushless fans.
20 Material
21 Housing High quality aluminum die-casting frame flated with
black paint.
22 Fan blade UL 94V - 0 Glass filled polyester ( P.B.T )
23 Bearing Sys Oil impregnated sleeve or
Ball Bearing : Japan
Hypro Bearing
one Ball one Sleeve
RoHS
24 RoHS wire UL 1430 , 22 AWG
25 Connector Not included in this fan
Note as : _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
30 Dimension & construction : All dimension, direction of rotation and air flow, rated
characteristics are specifide in drawing & data-sheet
of enclosed.
40 Characteristics definition :
41 Rated current Rated current shall be measured after 30 minutes
continuous rotation at rated voltage.
42 Rated speed Rated speed shall be measured after 30 minutes
continuous rotation at rated voltage.
43 Start voltage The voltages that enable to start the fan by sudden
switch on.
44 Input power Input power shall be measured after 30 minutes
continuous rotation at rated voltage.
45 Locked current Locked current shall be measured with in one minutes
or rotor locked , After 30 minutes continuous rotation at
rated voltage in clean air.
46 Air flow & static pressure The air flow data and static pressures are
determined in accordance with AMCA-210 standard or DIN
24163 specification in a double-chamber testing with
intake-side measurement.
V
V
2011.08.05
發行章
SPECIFICATION
Page 3/4ADDA CORPORATION AC FAN SERIES
47 Noise level The measurement of noise level is carried out with
reference to CNS8753 in a anechoic chamber with
the microphone positioned 1 M from the air intake.
Testing fan shall be hung in clear air.
50 Mechanical inspection
51 Rotation direction Clockwise from the front face of the fan. A clear
" = = > " ( arrow mark ) shall be found on the body
of housing .
52 Safe design All fans have intergrated protection against locked rotor
condition so that there can be no damage on winding
and / or any electrical components. Restart is automatic
as soon as any constraint to running has been released.
53 Locked rotor protection No damage shall be found for continuous 72
hours at condition of rotation locked. Restart is automatic
as soon as constraint to running has be relessed.
54 Free drop shock In minute package condition. The fan should withstand
each one drop of three faces from 30 cm distance height
onto 10 mm thickness of wooden board
60 Electrical inspection
61 Insulation resistance 100 M or more at 500 V megger.
62 Dielectric strength 1 minute at 1500 VAC / 50-60Hz
70 Environmental
71 Operating Temperature - 10 ~ + 70
72 Humidity RH 20 % ~ 85 % ( Max )
73 Storage Temperature Will satisfy performace standards after 500
hours storage at - 40 ~ 70 ( normal
humidity ) with a 24 - hour recovery period
at room temperature.
Feature of noise
level
measurement
microphone test fan
= = > air flow
1.0 M
2011.08.05
發行章
SPECIFICATION
ADDA CORPORATION Page 4/4AC FAN SERIES
74 Humidity After 96 hrs, 95 % RH, 40 ± 2 per MIL - STD - 202F,
method 103B, Humidity test, The measured data of insulation
resistance & dielectric strength should meet the specification
listed in attach.
75 Theraml Shock After thermal shock test per MIL - STD - 202F,
method 107G, condition D, The measured data of insulation
resistance & dielectric strength should the specification
listed in datasheet.
80 Remark
81 Material and construction are subject to change without advance notice.
The changes should be within specification listed in this approved sheet.
82 All the fans shall meet the inspection under sampling plan MIL - STD - 105E,
The AQL are as follow
Critical AQL = 0 . 25 %
Major AQL = 1 . 00 %
Minor AQL = 2 . 50 %
90 Drawing
2011.08.05
發行章
2011.08.05
發行章
2011.08.05
發行章