VOL628A
www.vishay.com Vishay Semiconductors
Rev. 1.8, 09-Aug-2018 3Document Number: 82401
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 2 - Test Circuit Fig. 3 - Test Circuit and Waveforms
Note
• According to DIN EN 60747-5-5 (VDE 0884), § 7.4.3.8.2, (see Fig. 4). This optocoupler is suitable for safe electrical isolation only within the
safety ratings. Compliance with the safety ratings shall be ensured by means of suitable protective circuits
CURRENT TRANSFER RATIO (Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT
IC/IFIF = ± 1 mA, VCE = 5 V
VOL628A CTR 50 - 600 %
VOL628A-2 CTR 63 - 125 %
VOL628A-3 CTR 100 - 200 %
VOL628A-4 CTR 160 - 320 %
SWITCHING CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Turn on time VCC = 5 V, IC = 2 mA, RL = 100 Ωton -6-μs
Rise time VCC = 5 V, IC = 2 mA, RL = 100 Ωtr-3.5- μs
Turn off time VCC = 5 V, IC = 2 mA, RL = 100 Ωtoff -5.5- μs
Fall time VCC = 5 V, IC = 2 mA, RL = 100 Ωtf-5-μs
isfh618a_13
VOUT
VCC = 5 V
RL
±I
F
isfh618a_12
10 %
90 %
Input pulse
Output pulse
tr
ton
tf
toff
SAFETY AND INSULATION RATINGS
PARAMETER TEST CONDITION SYMBOL VALUE UNIT
Climatic classification According to IEC 68 part 1 55 / 110 / 21
Pollution degree According to DIN VDE 0109 2
Comparative tracking index Insulation group IIIa CTI 275
Maximum rated withstanding isolation voltage According to UL1577, t = 1 min VISO 5000 VRMS
Maximum transient isolation voltage According to DIN EN 60747-5-5 VIOTM 8000 Vpeak
Maximum repetitive peak isolation voltage According to DIN EN 60747-5-5 VIORM 1050 Vpeak
Isolation resistance
Tamb = 25 °C, VIO = 500 V RIO ≥ 1012 Ω
Tamb = 100 °C, VIO = 500 V RIO ≥ 1011 Ω
Tamb = TS, VIO = 500 V RIO ≥ 109Ω
Output safety power PSO 265 mW
Input safety current ISI 130 mA
Input safety temperature TS150 °C
Creepage distance ≥ 8mm
Clearance distance ≥ 8mm
Insulation thickness DTI ≥ 0.4 mm
Input to output test voltage, method B VIORM x 1.875 = VPR, 100 % production test
with tM = 1 s, partial discharge < 5 pC VPR 2000 Vpeak
Input to output test voltage, method A VIORM x 1.6 = VPR, 100 % sample test
with tM = 10 s, partial discharge < 5 pC VPR 1680 Vpeak