Keysight Technologies N8700 Series System DC Power Supplies N8731A-42A (3.3 kW), N8754A-62A (5 kW) Data Sheet 02 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Family of Affordable Basic System DC Power Supplies The Keysight Technologies, Inc. N8700 series system DC power supplies give you just the right performance -- at just the right price -- in a compact (2 U) package. This family of affordable 3300 W and 5000 W single-output programmable DC power supplies consists of 21 models for simple DC power applications. They provide stable output power, built-in voltage and current measurement, and output voltage and current from 8 V to 600 V and 5.5 A to 400 A. These economical supplies offer many system-ready features like multiple standard I/O interfaces to simplify and accelerate test-system development for R&D, design validation, and manufacturing engineers in the aerospace/defense, automotive, component and communications industries. Small, high-density package saves you rack space The N8700 provides up to 5200 W in a small space-saving 2 U-high, 19-inch-wide package. Its air vents are in the front and rear (not on the top or bottom), so you can stack other instruments directly above or below it to save valuable rack space. Features - - - - - - - - 21 Models: 3300 W and 5000 W output power Up to 600 V and up to 400 A Small, high density 2 U package Built-in voltage and current measurement Full protection from over-voltage and over-current Flexible AC input voltage options LAN, USB, and GPIB interfaces standard Fully compliant to LXI Class C speciication (R) 03 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Easy front-panel operation You can quickly and easily operate the power supply with its rotary knobs and buttons. Using the front-panel controls, you can make coarse or ine adjustments of output voltage and current, protection settings, and set power-on states (last setting memory or factory default setting). The output voltage and current are displayed simultaneously, and LED indicators show power supply status and operating modes. You can lock the front panel controls to protect against accidental power-supply parameter changes. Extensive device protection To safeguard your device from damage, the N8700 Series power supplies provide over-temperature, over-current and over-voltage protection (OVP) to shut down the power supply output when a fault condition occurs. They also offer an undervoltage limit (UVL) that prevents adjustment of the output voltage below a certain limit. The combination of UVL and OVP capabilities lets you create a protection window for sensitive load circuitry. Simplify system connections The N8700 Series power supplies comes standard with GPIB, Ethernet/LAN, and USB 2.0 interfaces giving you the lexibility to use your I/O interface of choice today and safeguard your test setup for the future. The N8700 is fully compliant with the LXI Class C speciication. Figure 1. Front panel control knobs and buttons make the N8700 easy to use in a system and on the bench Figure 2. The N8700's standard LAN (LXI C), USB 2.0 and GPIB interfaces enable simple system connections 04 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Remote access and control The built-in Web server provides remote access and control of the instrument via a standard browser such as Microsoft Internet Explorer or Mozilla Firefox. This control goes above and beyond the LXI speciication, giving user's the ability to monitor and control the instrument from anywhere. Using the Web browser, you can set up, monitor and operate the N8700 remotely. Easy system integration and coniguration To simplify system development, the N8700 comes standard with IVI-COM drivers. The N8700 supports the easy-to-use SCPI (Standard Commands for Programmable Instruments). Flexible coniguration: connect multiple units in parallel or series Should you need greater output power, the N8700 series power supplies give you the lexibility to connect in parallel up to four identical units (same model number) for greater output current or connect two identical units (same model number) in series for greater output voltage (see output terminal isolation information). Analog programming and monitoring The output voltage and current can be programmed from zero to full scale by either an analog voltage 0 to 5 V or 0 to 10 V or by resistance of 0 to 5 k or 0 to 10 k. Flexible AC input voltage options The N8700 models offer lexible AC input voltage options. Every N8700 model can be purchased with either a 208 V 3-phase or 400 V 3-phase voltage input option. The 3.3 kW models have the additional option of a 230 V single-phase AC input voltage. Choose the one that best its your operating environment. They also provide power factor correction. Rack mounting The rack mount ears and handles are provided standard with every unit. In addition, the N5740A rack mount slide kit makes it easy to integrate an N8700 into a test rack by providing all the necessary hardware to rack mount an N8700 series power supply in only 2 U of rack space. The N5740A rack mount slide kit is the same kit used with the N5700 series. Figure 3. N8700 series web graphical user interface for remote access and control of the power supply Please choose carefully the AC input voltage option for your N8700 power supply. The AC input voltage cannot be changed without returning the unit to Keysight and placing a new order. 05 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Performance Speciications N8731A N8732A N8733A N8734A N8735A N8736A Voltage 1 8V 10 V 15 V 20 V 30 V 40 V Current 400 A 330 A 220 A 165 A 110 A 85 A 3200 W 3300 W 3300 W 3300 W 3300 W 3400 W CVp-p 3 60 mV 60 mV 60 mV 60 mV 60 mV 60 mV CVrms 4 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV 6.2 mV 6.5 mV 7.25 mV 8 mV 9.5 mV 11 mV 85 mA 71 mA 49 mA 38 mA 27 mA 22 mA CV line regulation 7 2.8 mV 3 mV 3.5 mV 4 mV 5 mV 6 mV CC line regulation 7 42 mA 35 mA 24 mA 18.5 mA 13 mA 10.5 mA 4 mV 5 mV 7.5 mV 10 mV 15 mV 20 mV 800 mA 660 mA 440 mA 330 mA 220 mA 170 mA DC output ratings 2 Power Output ripple and noise Load effect CV load regulation 5 CC load regulation 6 Source effect Programming accuracy Voltage 1 0.05% + Current 2, 8 0.1% + Measurement accuracy Voltage 0.1% + 8 mV 10 mV 15 mV 20 mV 30 mV 40 mV Current 8 0.1% + 1200 mA 990 mA 660 mA 495 mA 330 mA 255 mA <1 ms <1 ms <1 ms <1 ms <1 ms <1 ms Load transient recovery time Time 9 1. 2. 3. 4. 5. 6. 7. 8. 9. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage. Minimum current is guaranteed to maximum 0.4% of rated output current. 20 MHz 5 Hz - 1 MHz From no-load to full-load, constant input voltage. Maximum drop in remote sense. For load voltage change equal to the unit voltage rating, constant input voltage Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense. 06 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Performance Speciications (continued) N8737A N8738A N8739A N8740A N8741A N8742A Voltage 1 60 V 80 V 100 V 150 V 300 V 600 V Current 2 55 A 42 A 33 A 22 A 11 A 5.5 A Power 3300 W 3360 W 3300 W 3300 W 3300 W 3300 W CVp-p 3 60 mV 80 mV 100 mV 100 mV 300 mV 500 mV CVrms 4 8 mV 25 mV 25 mV 25 mV 100 mV 120 mV CV load regulation 5 14 mV 17 mV 20 mV 27.5 mV 50 mV 95 mV CC load regulation 6 16 mA 13.4 mA 11.6 mA 9.4 mA 7.2 mA 6.1 mA CV line regulation 7 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV CC line regulation 7 7.5 mA 6.2 mA 5.3 mA 4.2 mA 3.1 mA 2.6 mA DC output ratings Output ripple and noise Load effect Source effect Programming accuracy Voltage 1 0.05% + 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV Current 2, 8 0.1% + 110 mA 84 mA 66 mA 44 mA 22 mA 11 mA Measurement accuracy Voltage 0.1% + 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV Current 8 0.1% + 165 mA 126 mA 99 mA 66 mA 33 mA 16.5 mA <1 ms <1 ms <1 ms <2 ms <2 ms <2 ms Load transient recovery time Time 9 1. 2. 3. 4. 5. 6. 7. 8. 9. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage. Minimum current is guaranteed to maximum 0.4% of rated output current. 20 MHz 5 Hz - 1 MHz From no-load to full-load, constant input voltage. Maximum drop in remote sense. For load voltage change equal to the unit voltage rating, constant input voltage Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense. 07 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Supplemental Characteristics N8731A N8732A N8733A N8734A N8735A N8736A Up-prog response time 1 80 ms 80 ms 80 ms 80 ms 80 ms 80 ms Down-prog response time Full-load 1 20 ms 100 ms 100 ms 100 ms 160 ms 160 ms Down-prog response time No-load 2 500 ms 600 ms 700 ms 800 ms 900 ms 1000 ms Output response time Command response time (add this to the output response time to obtain the total programming time) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 2V 2V 2V 2V 5V 5V 0.5-10 V 0.5-12 V 1-18 V 1-24 V 2-36 V 2-44 V 1300 mA 1200 mA 880 mA 660 mA 300 mA 200 mA Remote sense compensation Over-voltage protection Range Output ripple and noise CC rms 3 Programming resolution Measurement resolution Voltage 0.96 mV 1.2 mV 1.8 mV 2.4 mV 3.6 mV 4.8 mV Current 48 mA 39.6 mA 26.4 mA 19.8 mA 13.2 mA 10.2 mA Voltage 40 mV 50 mV 75 mV 100 mV 150 mV 200 mV Current 2000 mA 1650 mA 1100 mA 825 mA 550 mA 425 mA Front panel display accuracy (4 digits; 1 count) Temperature stability (over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature) Voltage 4 mV 5 mV 7.5 mV 10 mV 15 mV 20 mV Current 200 mA 165 mA 110 mA 82.5 mA 55 mA 42.5 mA Temperature coeficient (after a 30 minute warm-up) Voltage (from rated output voltage) 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C Current (from rated output current) 200 PPM/C 200 PPM/C 200 PPM/C 200 PPM/C 200 PPM/C 200 PPM/C 1. From 10% to 90% or 90% to 10% of rated output voltage, with rated, resistive load. 2. From 90% to 10% of rated output voltage. 3. For 8 V - 15 V models the ripple is measured from 2 V to rated output voltage and rated output current. For other models, the ripple is measured at 10 - 100% of rated output voltage and rated output current. 08 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Supplemental Characteristics (continued) N8737A N8738A N8739A N8740A N8741A N8742A Up-prog response time 1 150 ms 150 ms 150 ms 150 ms 150 ms 250 ms Down-prog response time Full-load 1 160 ms 300 ms 300 ms 300 ms 300 ms 500 ms 1100 ms 1200 ms 1500 ms 2000 ms 3500 ms 4000 ms Output response time Down-prog response time No-load 2 Command response time (add this to the output response time to obtain the total programming time) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 5V 5V 5V 5V 5V 5V 5-66 V 5-88 V 5-110 V 5-165 V 5-330 V 5-660 V 100 mA 80 mA 70 mA 60 mA 20 mA 10 mA Remote sense compensation Over-voltage protection Range Output ripple and noise CC rms 3 Programming resolution Measurement resolution Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV Current 6.6 mA 5 mA 4 mA 2.6 mA 1.3 mA 0.66 mA Voltage 300 mV 400 mV 500 mV 750 mV 1500 mV 3000 mV Current 275 mA 210 mA 165 mA 110 mA 55 mA 27.5 mA Front panel display accuracy (4 digits; 1 count) Temperature stability (over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature) Voltage 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV Current 27.5 mA 21 mA 16.5 mA 11 mA 5.5 mA 2.8 mA Temperature coeficient (after a 30 minute warm-up) Voltage (from rated output voltage) 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C Current (from rated output current) 200 PPM/C 200 PPM/C 200 PPM/C 200 PPM/C 200 PPM/C 200 PPM/C 1. From 10% to 90% or 90% to 10% of rated output voltage, with rated, resistive load. 2. From 90% to 10% of rated output voltage. 3. For 8 V - 15 V models the ripple is measured from 2 V to rated output voltage and rated output current. For other models, the ripple is measured at 10 - 100% of rated output voltage and rated output current. 09 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Performance Speciications N8754A N8755A N8756A N8757A N8758A 20 V 30 V 40 V 60 V 80 V 250 A 170 A 125 A 85 A 65 A 5000 W 5100 W 5000 W 5100 W 5200 W CVp-p 3 75 mV 75 mV 75 mV 75 mV 100 mV 4 10 mV 10 mV 10 mV 10 mV 15 mV 8 mV 9.5 mV 11 mV 14 mV 17 mV 250 mA 170 mA 125 mA 85 mA 65 mA 2 mV 3 mV 4 mV 6 mV 8 mV 125 mA 85 mA 62.5 mA 42.5 mA 32.5 mA 15 mV 22.5 mV 30 mV 45 mV 60 mV 750 mA 510 mA 375 mA 255 mA 195 mA 25 mV 37.5 mV 50 mV 75 mV 100 mV 750 mA 510 mA 375 mA 255 mA 195 mA <1 ms <1 ms <1 ms <1 ms <1 ms DC output ratings Voltage 1 Current 2 Power Output ripple and noise CVrms Load effect CV load regulation 5 CC load regulation 6 Source effect CV line regulation 7 CC line regulation 7 Programming accuracy Voltage 1 Current 0.025% + 2, 8 0.1% + Measurement accuracy Voltage Current 0.025% + 8 0.1% + Load transient recovery time Time 9 1. 2. 3. 4. 5. 6. 7. 8. 9. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage. Minimum current is guaranteed to maximum 0.4% of rated output current. 20 MHz 5 Hz - 1 MHz From no-load to full-load, constant input voltage. Maximum drop in remote sense. For load voltage change equal to the unit voltage rating, constant input voltage Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense. 10 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Performance Speciications (continued) N8759A N8760A N8761A N8762A 100 V 150 V 300 V 600 V 50 A 34 A 17 A 8.5 A 5000 W 5100 W 5100 W 5100 W CVp-p 3 100 mV 120 mV 300 mV 500 mV CVrms 4 15 mV 25 mV 60 mV 120 mV CV load regulation 5 20 mV 27.5 mV 50 mV 95 mV CC load regulation 6 50 mA 34 mA 17 mA 8.5 mA CV line regulation 7 10 mV 15 mV 30 mV 60 mV CC line regulation 7 25 mA 17 mA 8.5 mA 4.3 mA 75 mV 112.5 mV 225 mV 450 mV 0.1% + 150 mA 102 mA 51 mA 25.5 mA 0.025% + 125 mV 187.5 mV 375 mV 750 mV 0.1% + 150 mA 102 mA 51 mA 25.5 mA <1 ms <2 ms <2 ms <2 ms DC output ratings Voltage 1 Current 2 Power Output ripple and noise Load effect Source effect Programming accuracy Voltage 1 0.025% + Current 2, 8 Measurement accuracy Voltage Current 8 Load transient recovery time Time 9 1. 2. 3. 4. 5. 6. 7. 8. 9. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage. Minimum current is guaranteed to maximum 0.4% of rated output current. 20 MHz 5 Hz - 1 MHz From no-load to full-load, constant input voltage. Maximum drop in remote sense. For load voltage change equal to the unit voltage rating, constant input voltage Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense. 11 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Supplemental Characteristics N8754A N8755A N8756A N8757A N8758A Up-prog response time 1 30 ms 30 ms 30 ms 50 ms 50 ms Down-prog response time Full-load 1 50 ms 80 ms 80 ms 80 ms 100 ms Down-prog response time No-load 2 700 ms 800 ms 900 ms 1000 ms 1200 ms Output response time Command response time (add this to the output response time to obtain the total programming time) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 2V 5V 5V 5V 5V 1-24 V 2-36 V 2-44 V 5-66 V 5-88 V 1000 mA 460 mA 300 mA 150 mA 120 mA Voltage 2.4 mV 3.6 mV 4.8 mV 7.2 mV 9.6 mV Current 30 mA 20.4 mA 15 mA 10.2 mA 7.8 mA Voltage 100 mV 150 mV 200 mV 300 mV 400 mV Current 1250 mA 850 mA 625 mA 425 mA 325 mA Remote sense compensation Over-voltage protection Range Output ripple and noise CC rms 3 Programming resolution Measurement resolution Front panel display accuracy (4 digits; 1 count) Temperature stability (over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature) Voltage 10 mV 15 mV 20 mV 30 mV 40 mV Current 125 mA 85 mA 62.5 mA 42.5 mA 32.5 mA 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C Current (from rated output current) 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C Temperature coeficient Voltage (from rated output voltage) 1. From 10% to 90% or 90% to 10% of rated output voltage, with rated, resistive load. 2. From 90% to 10% of rated output voltage. 3. For 8 V - 15 V models the ripple is measured from 2 V to rated output voltage and rated output current. For other models, the ripple is measured at 10 - 100% of rated output voltage and rated output current. 12 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Supplemental Characteristics (continued) N8759A N8760A N8761A N8762A Up-prog response time 1 50 ms 50 ms 50 ms 100 ms Down-prog response time Full-load 1 100 ms 100 ms 100 ms 200 ms 1500 ms 2000 ms 2500 ms 3000 ms Output response time Down-prog response time No-load 2 Command response time (add this to the output response time to obtain the total programming time) 100 ms (typical) 100 ms (typical) 100 ms (typical) 100 ms (typical) 5V 5V 5V 5V 5-110 V 5-165 V 5-330 V 5-660 V 100 mA 90 mA 30 mA 15 mA Voltage 12 mV 18 mV 36 mV 72 mV Current 6 mA 4.1 mA 2 mA 1 mA Voltage 500 mV 750 mV 1500 mV 3000 mV Current 250 mA 170 mA 85 mA 42.5 mA Remote sense compensation Over-voltage protection Range Output ripple and noise CC rms 3 Programming resolution Measurement resolution Front panel display accuracy (4 digits; 1 count) Temperature stability (over 8 hours, after a 30 minute warm-up, with constant line, load, and temperature) Voltage 50 mV 75 mV 150 mV 300 mV Current 25 mA 17 mA 8.5 mA 4.3 mA 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C Current (from rated output current) 100 PPM/C 100 PPM/C 100 PPM/C 100 PPM/C Temperature coeficient Voltage (from rated output voltage) 1. From 10% to 90% or 90% to 10% of rated output voltage, with rated, resistive load. 2. From 90% to 10% of rated output voltage. 3. For 8 V - 15 V models the ripple is measured from 2 V to rated output voltage and rated output current. For other models, the ripple is measured at 10 - 100% of rated output voltage and rated output current. 13 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Supplemental Characteristics (continued) All Models (unless otherwise speciied) Analog programming and monitoring Vout voltage programming Iout voltage programming 0-100%, 0-5 V or 0-10 V, user selectable. Accuracy and linearity: 0.5% of rated Vout. 1 Vout resistor programming Iout resistor programming 1 0-100%, 0-5 V or 0-10 V, user selectable. Accuracy and linearity: 1% of rated Iout. 0-100%, 0-5/10 Kohm full scale, user selectable. Accuracy and linearity: 1% of rated Vout. 0-100%, 0-5/10 Kohm full scale, user selectable. Accuracy and linearity: 1.5% of rated Iout. On/Off control (rear panel) Controlled by voltage: 0-0.6 V/2-15 V, or dry contact, user selectable logic. Output current monitor 1 0-5 V or 0-10 V, user selectable, Accuracy: 1%. Output voltage monitor 0-5 V or 0-10 V, user selectable, Accuracy: 1%. Power supply OK signal TTL high (4-5 V) = OK; 0 V = Fail; 500 ohm series resistance. CV/CC Indicator 3.3 kW: CV = TTL high (4-5 V) (source current: 10 mA); CC = TTL low (0-0.6 V) (sink current = 10 mA) 5 kW: Open collector; CV mode: OFF, CC mode: ON, Max voltage = 30 V; Max sink current = 10 mA Enable/disable Dry contact. Open: off, Short: on. Max. voltage at terminal = 6 V Series and parallel capability Parallel operation Up to 4 identical units (same model number) can be connected in master/slave mode with single-wire current balancing Series operation Up to 2 identical units (same model number) can be connected using external protection diodes (see Output Terminal Isolation on page 13) Savable states In volatile memory 16 (in memory locations 0-15) Interface capabilities GPIB SCPI - 1993, IEEE 488.2 compliant interface LXI Compliance Class C (only applies to units with the LXI label on the front panel) USB 2.0 Requires Keysight I/O Library version M.01.01 and up, or 14.0 and up 10/100 LAN Requires Keysight I/O Library version L.01.01 and up, or 14.0 and up Environmental conditions Environment Indoor use, installation category II (AC input), pollution degree 2 Operating temperature 0C to 40C @ 100% load Storage temperature -20C to 70C Operating humidity 30% to 90% relative humidity (no condensation) Storage humidity 10% to 95% relative humidity (no condensation) Altitude Up to 3000 meters. Above 2000 m, derate the output current by 2%/100 m and derate the maximum ambient temperature by 1C/100 m. Built-in Web server Requires Internet Explorer 5+ or Netscape 6.2+ 1. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift. 14 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Supplemental Characteristics (continued) All Models (unless otherwise speciied) Dimensions (excluding connectors and handles) Height: 88 mm (3.46 in); Width: 423 mm (16.65 in); Depth: 442.5 mm (17.42 in) Weight 3.3 kW: 13 kg (28.6 lbs.); 5 kW: 16 kg (35.2 lbs.) Regulatory compliance EMC Complies with the European EMC directive 89/336/EEC for Class A test and measurement products. Complies with the Australian standard and carries the C-Tick mark. This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canada. Electrostatic discharges >1 kV near the I/O connectors may cause the unit to reset and require operator intervention. Safety Complies with the European Low Voltage Directive 73/23/EEC and carries the CE-marking. Complies with the US and Canadian safety standards for test and measurement products. Any LEDs used in this product are Class 1 LEDs as per IEC 825-1 Acoustic noise declaration Statements provided to comply with requirements of the German Sound Emission Directive, from 18 January 1991: Sound Pressure Lp <70 dB(A), *At Operator Position, *Normal Operation, *According to EN 27779 (Type Test). Schalldruckpegel Lp <70 dB(A) *Am Arbeitsplatz, *Normaler Betrieb, *Nach EN 27779 (Typprufung). Output terminal isolation 8 V to 60 V units No output terminal may be more than 60 VDC from any other terminal or chassis ground. 80 V to 600 V units No positive output terminal may be more than 600 VDC from any other terminal or chassis ground. No negative output terminal may be more than 400 VDC from any other terminal or chassis ground. 15 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Supplemental Characteristics (continued) All Models (unless otherwise speciied) AC Input Nominal input Input current Input range Input VA Power factor Eficiency Inrush current 1. 230 VAC single-phase option 1 190 - 240 VAC; 50/60 Hz 208 VAC 3-phase option 190 - 240 VAC; 50/60 Hz 400 VAC 3-phase option 380 - 415 VAC; 50/60 Hz 230 VAC single-phase option 1 23 - 24 A Max @ 100% load 208 VAC 3-phase option 3.3 kW models: 13.6 - 14.5 A Max @ 100% load 5 kW models: 21-22 A max @ 100% load 400 VAC 3-phase option 3.3 kW models: 6.8 - 7.2 A Max @ 100% load 5 kW models: 10.5 - 12 A Max @ 100% load 230 VAC single-phase option 1 170 - 265 VAC; 47 - 63 Hz 208 VAC 3-phase option 170 - 265 VAC; 47 - 63 Hz 400 VAC 3-phase option 342 - 460 VAC; 47 - 63 Hz 3.3 kW models 4000 VA 5 kW models 5800 VA 230 VAC single-phase option 1 0.99 at nominal input and rated output power 208 & 400 VAC 3-phase options 3.3 kW models: 0.95 at nominal input and rated output power 5 kW models: 0.94 at nominal input and rated output power 3.3 kW models 82% - 88% 5 kW models 83% - 88% 230 VAC single-phase option 1 < 50 A 208 VAC 3-phase option < 50 A 400 VAC 3-phase option < 20 A Available on 3.3 kW models only. 16 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Outline Diagram 88.0 mm 0.3 mm 482.0 mm 1.0 mm 423.0 mm 1.0 mm 39.0 mm 0.3 mm 497.5 mm (150 V to 600 V models) 86.0 mm 0.3 mm 42.0 mm 60.5 mm 92.0 mm 92.0 mm 442.5 mm 1.0 mm 40.0 mm 5.0 mm DC Output Bus-Bar detail 8 V to 100 V models 50.0 mm F10.5 mm 80.0 mm AC Input Output cover detail 8 V to 100 V models 108.0 mm 17 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Front and Rear Panel Detail Front panel (All models) = air flow (in front, out rear) Rear panel with busbars 8 V to 100 V models (shown with 230 V single-phase AC input voltage option, available on 3.3 kW models only) Rear panel with wire clamp connectors 150 V to 600 V models (shown with 400 V 3-phase AC option, available on all models) 18 | Keysight | N8700 Series System DC Power Supplies - Data Sheet Ordering Information Keysight N8700 Series Model Voltage (V) Current (A) Max Power (W) Series N8731A 8V 400 A 3200 W 3.3 kW N8732A 10 V 330 A 3300 W 3.3 kW N8733A 15 V 220 A 3300 W 3.3 kW N8734A 20 V 165 A 3300 W 3.3 kW N8735A 30 V 110 A 3300 W 3.3 kW N8736A 40 V 85 A 3400 W 3.3 kW N8737A 60 V 55 A 3300 W 3.3 kW N8738A 80 V 42 A 3360 W 3.3 kW N8739A 100 V 33 A 3300 W 3.3 kW N8740A 150 V 22 A 3300 W 3.3 kW N8741A 300 V 11 A 3300 W 3.3 kW N8742A 600 V 5.5 A 3300 W 3.3 kW N8754A 20 V 250 A 5000 W 5 kW N8755A 30 V 170 A 5100 W 5 kW N8756A 40 V 125 A 5000 W 5 kW N8757A 60 V 85 A 5100 W 5 kW N8758A 80 V 65 A 5200 W 5 kW N8759A 100 V 50 A 5000 W 5 kW N8760A 150 V 34 A 5100 W 5 kW N8761A 300 V 17 A 5100 W 5 kW N8762A 600 V 8.5 A 5100 W 5 kW Options All Models (unless otherwise speciied) Opt 861 Unterminated line cord for 208 V 3-phase AC input voltage (Option 208) Opt 862 Unterminated line cord for 400 V 3-phase AC input voltage (Option 400) Opt 831 1 Unterminated line cord for 230 V single-phase AC input voltage (Option 230) Opt 832 1 Unterminated, harmonized line cord for Europe for 230 V single-phase AC input voltage (Option 230) Opt 208 190-240 V, 3-phase AC, 50/60 Hz input (use with line cord Opt 861) Opt 400 380-415 V, 3-phase AC, 50/60 Hz input (use with line cord Opt 862) Opt 23011 190-240 V, single-phase AC, 50/60 Hz input (use with line cord Opt 831 or 832) Accessories N5740A 1. Rack mount slide kit (required for rack mounting; standard system rack-mounting hardware will not work) Available on 3.3 kW models only. 19 | Keysight | N8700 Series System DC Power Supplies - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA(R) Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA(R), AdvancedTCA(R), and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Paciic Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight's commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight's measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/N8700 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) This information is subject to change without notice. (c) Keysight Technologies, 2009 - 2014 Published in USA, July 31, 2014 5990-3881EN www.keysight.com