3
Electrical / Optical Characteristics @ TA=25°C
White
Parameter Symbol Min. Typ. Max. Unit Test Condition
Average Luminous Intensity IV28 44 – mcd IF = 5 mA
Chromaticity Coordinates (X,Y) Refer to Figure 1 IF = 5 mA
Forward Voltage, Per Segment VF– 2.95 3.8 V IF = 5 mA
Reverse Current, Per Segment IR– – 100 PAVR = 5 V
Luminous Intensity Matching Ratio IV-m ––2:1–I
F = 5 mA
Absolute Maximum Ratings @ TA=25°C
Parameter White Unit
Power Dissipation Per Segment 39 mW
Peak Forward Current Per Segment
(1/10 Duty Cycle., 0.1ms pulse width)
80 mA
Continuous Forward Current Per Segment
Derating Linearly From 25°C Per Segment
25 mA
0.25 mA/°C
Reverse Voltage Per Segment 5 V
Operating Temperature Range -40°C to +105°C
Storage Temperature Range -40°C to +105°C