SPECIFICATION CONTROL DRAWING TITLE 55PC1221 Date TWO CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT 10-24-07 Revision D This specification sheet forms a part of the latest issue of Raychem Specification 55PC. COMPONENT WIRES - 55PC0211 JACKET - SHIELD - TIN-COATED COPPER RADIATION-CROSSLINKED, MODIFIED ETFE CONSTRUCTION DETAILS PART NUMBER 1/ CONDUCTOR SIZE (AWG) SHIELD SIZE (AWG) JACKET THICKNESS ( in. ) LOWER SPEC LIMIT TARGET WALL DIAMETER ( in. ) LOWER SPEC LIMIT WEIGHT ( lbs/1000 ft. ) TARGET VALUE UPPER SPEC LIMIT TARGET VALUE UPPER SPEC LIMIT 55PC1221-26-* 26 38 .0050 .0065 .096 .100 .104 7.62 8.02 55PC1221-24-* 24 38 .0050 .0065 .105 .109 .113 9.34 9.75 55PC1221-22-* 22 38 .0055 .0070 .118 .122 .127 12.02 12.50 55PC1221-20-* 20 38 .0055 .0070 .135 .139 .144 16.02 16.56 55PC1221-18-* 18 38 .0055 .0070 .154 .158 .163 21.57 22.25 55PC1221-16-* 16 38 .0060 .0075 .169 .174 .179 26.21 26.96 55PC1221-14-* 14 38 .0060 .0075 .199 .204 .209 37.10 38.07 55PC1221-12-* 12 38 .0060 .0080 .238 .243 .248 53.45 54.60 55PC1221-10-* 10 36 .0065 .0085 .289 .296 .303 82.84 84.67 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. The TE logo, Tyco Electronics and Raychem are trademarks. Page 1 of 2 DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Raychem Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 (c) 2007 Tyco Electronics Corporation. All rights reserved. SPECIFICATION CONTROL DRAWING CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level CROSSLINK VERIFICATION: 300 3C for 1 hour DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz JACKET COLOR: White preferred JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in (minimum) JACKET FLAWS: Spark Test, 1000 volts (rms) Impulse Dielectric Test, 6.0 kV (peak) SHIELD COVERAGE: 85% (minimum) VOLTAGE WITHSTAND TEST (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The "*" in the part numbers on page 1 shall be replaced by color code designators with a slash separating the component wire colors and a dash separating the component wire colors from the jacket color. 1/ Example: AWG 22, red and blue component wires; white jacket: 55PC1221-22-2/6-9 1/ See footer section on page 1 Revision Page 2 of 2 D SCD 55PC1221