30 March 2015 Page |1 Active Power Factor Correction Redundant operation 93% Efficiency True Three Phase Delta & Y 480Vac Input Single Wire Current Sharing I2C interface, PMBus Compatible Variable fan speed control UL, cUL, CB, CE and DEMKO Certified RoHS Compliant Two Year Warranty SPECIFICATIONS Model Ripple & Noise Line Regulation 0.2% Output Load Regulation 1% on both outputs Transient Response 2% Maximum deviation; returns to initial condition in 1 msec max. Long Term Stability 0.01% after 20 minute warm-up Hold-Up Time OVP Input Range 12mS minimum 115% to 135% on both outputs 180-523VAC 3 Phase Frequency 47-63Hz EMI filter EN55022 Class A, FCC Inrush Current Input HP3200-2121 12Vdc (3200 Watts with self-contained fan cooling) and 12VSB 1% Pk to Pk DC Output Input Current Isolation (Input to Output) Efficiency Active PFC Switching Frequency Protections Short-circuit Environment Leakage Humidity Overload (1) Over Temperature Temperature Coef. Operating Temperature www.autec.com 64A@480 30A @ 305VAC 4242 VDC 93% Max. 0.99 130KHz 3.5mA Constant current with delayed latching method on the primary output. The 12V standby utilizes the hiccup method. Constant current with delayed latching method on the primary output. The 12V standby utilizes the hiccup method. The power supply will shut down if temperature is greater than 100C (internal temperature). The power supply is selfrecovering once the internal temperature falls bellow 71C Up to 95% non-condensing 0.01% / C 0 to 50C continuous duty, full rating. Derate linearly to 50% of full rating at 71C. Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 Safety 30 March 2015 Page |2 UR UL60950-1 Second Edition cUR cUL60950-1 Second Edition DEMKO EN60950-1 Second Edition CE IEC 60960 CB Internal FET isolation provided for N+1 redundant operation. FET Isolation Outputs will current share within 5% when interconnected by a single wire Current Sharing Features Digital Voltage Adjustment The voltage adjustment allows +/- 10% remote adjustment PS On The secondary outputs are enable only upon mating a shorter enable pin to output common on the customers backplane. AC Ok A TTL low signal provides a 4ms warning prior to DC outputs dropping out of regulation. A TTL high logic signal provides warning of output voltage below 90% of nominal, fan fault or over temperature. Fault A TTL high logic signal is provided when the input and output voltages are within normal operating conditions. Power Okay A pin on the power supply is used to identify that the power supply has been installed into the customers backpane. PS Present A TTL low logic signal sent to inhibit the main output. Upon release of the signal, output are restored. Inhibit Monitors temperature, output voltage, input voltage, input current, and output current; control Fan speed, Fan LED and connects to a serial NVRAM which is programmed with serial number. PMBUS software allows monitoring of overall operation of power supply. I2C 16.98" L*3.9" W * 1.58"H (431.3mm * 99.0mm * 40.2mm) Other Dimensions Weight 6.7 lbs. RoHS Complies with EU Directive 2011/65/EU for the restriction of certain hazardous substances Model No. / OUTPUT VOLTAGE / CURRENT RATINGS CHART Model No. HP3200-X121 O/P Voltage (Vdc) 12V 12VSB Minimum 0A 0A Maximum 266.6A 2.0A Derating Curve W A T T S www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 30 March 2015 Page |3 Notes 1. The constant current method allows for a 5-second delay before the power supply shuts down if the output current rating exceeds 110% to 130% of maximum rated output current. The input must be recycled manually or digitally reset. LED Operation www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 30 March 2015 Page |4 Limit Values www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 30 March 2015 Page |5 SMBus Alerts www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 30 March 2015 Page |6 Mechanical Specifications www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 30 March 2015 Page |7 Pin Configuration SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE AUTEC IS NOT RESPONSIBLE FOR ISSUES ARISING FROM ERRORS OR OMMISIONS www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777