HP
413
AC TYPE (50/60 Hz) at 60 Hz, 20
°
C 68
°
F
Type Part No. Nominal coil
voltage, V AC Pick-up
voltage,
V AC (max.)
Drop-out
voltage,
V AC (min.)
Max.
allowable
voltage, V AC Inductance,
HNominal coil
current, mA Nominal
operating
power, VA
2 Form C
HP2-AC6V 6 4.8 1.8 6.6 0.049 310 1.9
HP2-AC12V 12 9.6 3.6 13.2 0.190 160 1.9
HP2-AC24V 24 19.2 7.2 26.4 0.776 78 1.9
HP2-AC48V 48 38.4 14.4 52.8 3.106 39 1.9
HP2-AC115V 115 92 34.5 126.5 15.83 18 2.1
HP2-AC220V 220 176 66 242 57.90 9.5 2.1
HP2-AC240V 240 192 72 264 66.26 9.0 2.2
3 Form C
HP3-AC6V 6 4.8 1.8 6.6 0.030 520 3.1
HP3-AC12V 12 9.6 3.6 13.2 0.119 260 3.1
HP3-AC24V 24 19.2 7.2 26.4 0.475 130 3.1
HP3-AC48V 48 38.4 14.4 52.8 1.899 65 3.1
HP3-AC115V 115 92 34.5 126.5 10.36 28.5 3.3
HP3-AC220V 220 176 66 242 39.32 14.2 3.1
HP3-AC240V 240 192 72 264 44.05 13.9 3.3
4 Form C
HP4-AC6V 6 4.8 1.8 6.6 0.019 800 4.8
HP4-AC12V 12 9.6 3.6 13.2 0.077 400 4.8
HP4-AC24V 24 19.2 7.2 26.4 0.309 200 4.8
HP4-AC48V 48 38.4 14.4 52.8 1.292 95 4.6
HP4-AC115V 115 92 34.5 126.5 6.953 42 4.8
HP4-AC220V 220 176 66 242 26.57 21 4.6
HP4-AC240V 240 192 72 264 29.75 20.5 4.9
NOTES
1. The range of coil current for AC relays
is
±
15% (60 Hz). For DC relays it is
±
10% at 20
°
C, 68
°
F.
2. The HP relay will operate in a range
from 80% to 110% of the nominal coil
voltage. It is, however, recommended
that the relay be used in the range of
85% to 110% of the nominal coil volt-
age, with the temporary voltage varia-
tion taken into consideration.
3. When the operating voltage of AC re-
lays drops below 80% of the nominal
coil voltage, the relay will generate a
considerable amount of heat which is
not recommended for maximum effi-
ciency.
4. The coil resistance of DC types is the
measured value of the coil at a temper-
ature of 20
°
C 68
°
F. If the coil tempera-
ture changes by
±
1
°
C, the measured
value of the coil resistance should be
increased or decreased by 0.4%.
5. For applications from 220 V to 240 V
DC, connect a resistor in series with
the rela y coil. See chart for resistor val-
ues.
Voltage 2 Form C 3 Form C 4 Form C
220 V DC 7.3 k
Ω
(5 W) 7.45 k
Ω
(5 W) 7 k
Ω
(5 W)
240 V DC 8.7 k
Ω
(5 W) 8.8 k
Ω
(5 W) 8.3 k
Ω
(5 W)
2. Standard plug-in terminal type (with lamp wired)
DC TYPES at 20
°
C 68
°
F
Type Part No. Nominal coil
voltage,
V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max.
allowable
voltage,
V DC
Coil
resistance,
Ω
(
±
10%)
Nominal coil
current,
mA
Nominal
operating
power ,
W
2 Form C LED
HP2-L-DC6V 6 4.8 0.9 6.6 25 240 1.5
HP2-L-DC12V 12 9.6 1.8 13.2 110 109 1.3
HP2-L-DC24V 24 19.2 3.6 26.4 440 54.5 1.3
HP2-L-DC48V 48 38.4 7.2 52.8 1,800 26.7 1.3
Neon lamp HP2-L-DC110V 110 88 16.5 121 7,300 15.0 1.7
3 Form C LED
HP3-L-DC6V 6 4.8 0.9 6.6 24 250 1.5
HP3-L-DC12V 12 9.6 1.8 13.2 100 120 1.4
HP3-L-DC24V 24 19.2 3.6 26.4 400 60 1.4
HP3-L-DC48V 48 38.4 7.2 52.8 1,560 31 1.5
Neon lamp HP3-L-DC110V 110 88 16.5 121 7,450 14.9 1.6
4 Form C LED
HP4-L-DC6V 6 4.8 0.9 6.6 22 273 1.6
HP4-L-DC12V 12 9.6 1.8 13.2 95 127 1.5
HP4-L-DC24V 24 19.2 3.6 26.4 380 63 1.5
HP4-L-DC48V 48 38.4 7.2 52.8 1,500 32 1.5
Neon lamp HP4-L-DC110V 110 88 16.5 121 7,000 15.7 1.7