Timers Signaling Lights Switches & Pilot Lights GT5P GT5P Series -- ON Delay Timers Key features: * * * * * * * SPDT, 5A contacts 8-pin, octal base 9 time ranges Repeat error 0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED indicators Uses the same sockets and hold down clips as IDEC's RR2P 8-pin relays UL Recognized File No. E55996 CSA Certified File No. LR66809 Relays & Sockets Specifications Rated Operating Voltage 100 to 120V AC (50/60Hz) 200 to 240V AC (50/60Hz) 24V AC/DC 12V DC Voltage Tolerance AC type: 15% DC type: 10% (ripple 10% maximum) Resistive load 120V AC/24V DC, 5A 240V AC, 3A Inductive load 240V AC, 0.8A 120V AC, 1.4A 24V DC, 1.7A Circuit Breakers Terminal Blocks Contactors Timers Contact Rating Allowable Contact Power (resistive load) 960VA AC 120W DC Contact Form SPDT Voltage 250V AC, 150V DC Repeat Error 0.2% 10msec Voltage Error 0.5% 10msec Temperature Error 3% maximum (over -10 to 50C, reference temperature 20C) Setting Error 10% maximum Reset Time When turning power off after time up: 0.1 sec maximum When turning power off before time up: 1 sec maximum Insulation Resistance 100M minimum Dielectric Strength 2000V AC, 1 minute (except between contacts of the same pole) Vibration Resistance 100N (approximate 10G) Shock Resistance Operating extremes: 100N (approximate 10G) Damage limits: 500N (approximate 50G) Power Consumption 100V AC type: 1.5VA (at 50Hz) 200V AC type: 1.6VA (at 50Hz) 24V DC type: 0.9W Electrical Life 100,000 operations minimum (at rated load) Mechanical Life 20,000,000 operations minimum Operating Temperature -10 to +50C Operating Humidity 45 to 85% RH 1. Inductive load (reference), cos o =0.3 to 0.4 or L/R=15msec. 2. Minimum applicable load: 5VDC/10mA (reference). 870 www.IDEC.com Timers GT5P Mode of Operation Contact Output Rated Voltage ON-Delay SPDT 24V DC/120V AC, 5A 240V AC, 3A GT5P-N3SA100 6S -- 10S GT5P-N10SA100 30S GT5P-N30SA100 60S GT5P-N60SA100 3M GT5P-N3MA100 6M GT5P-N6MA100 10M GT5P-N10MA100 1S GT5P-N1SA200 3S -- 6S GT5P-N6SA200 10S GT5P-N10SA200 30S GT5P-N30SA200 60S GT5P-N60SA200 3M GT5P-N3MA200 6M GT5P-N6MA200 10M GT5P-N10MA200 1S GT5P-N1SAD24 3S -- 6S GT5P-N6SAD24 10S GT5P-N10SAD24 30S -- 60S GT5P-N60SAD24 3M -- 6M GT5P-N6MAD24 10M GT5P-N10MAD24 1S -- 3S -- -- GT5P-N10SD12 30S GT5P-N30SD12 60S GT5P-N60SD12 3M -- 6M -- 10M GT5P-N10MD12 Terminal Blocks 6S 10S Contactors 12V DC -- 3S Timers 24V AC/DC 1S Relays & Sockets 200 to 240V AC Complete Part No. Signaling Lights 100 to 120V AC Time Range Switches & Pilot Lights Part Numbering List For sockets and accessories, see page 873. Circuit Breakers 800-262-IDEC (4332) * USA & Canada 871 Timers GT5P Switches & Pilot Lights Timing Diagram/Schematic/Electrical Life Curves SPDT m n l (-) k Operation Mode o p (+) j q Signaling Lights POWER Do not apply voltage to terminals 1, 3, and 4. Item Set Time Power ON-Delay Delayed Contact Relays & Sockets Indicator Terminal Number 2 - 7 (8p) 5 - 8 (8p) (NC) 6 - 8 (8p) (NO) POWER OUT Circuit Breakers Terminal Blocks Contactors Timers Electrical Life Curves 872 www.IDEC.com Operation Timers GT5P Switches & Pilot Lights Accessories Mounting Mounting Accessories and Sockets Style Appearance Use with Timers Part No. GT5P SR2P-05 Appearance Part No. Signaling Lights 8-Pin Screw Terminal (dual tier) Applicable Hold-Down Springs SFA-203 GT5P SR2P-05C 8-Pin Screw Terminal GT5P SR2P-06 -- BNDN1000 Relays & Sockets 8-Pin Fingersafe Socket DIN Rail/ Surface Mounting Accessories SFA-202 Timers DIN Mounting Rail Length 1000mm Part Numbers: Mounting Accessories and Sockets 8-Pin Solder Terminal SR2P-51 Installation of Hold-Down Springs DIN Rail Mount Socket Contactors Mounting Accessories Applicable Hold-Down Springs SFA-402 Terminal Blocks Panel Mount Socket Insert the springs into the outer slots with the projections facing inside. Hold-down Spring SFA-402 Insert the springs into the slots. Insert 8-pin Socket SR2P-51 Socket SR2P-05 Hold-down Spring (sold separately) SFA-202 (use two springs) Hold-down Spring (sold separately) SFA-203 (use two springs) Circuit Breakers Socket SR2P-06 800-262-IDEC (4332) * USA & Canada 873 Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights GT5P 874 Timers Dimensions GT5P Timer, 8-Pin with SR2P-05 GT5P Timer, 8-Pin with SR2P-06 www.IDEC.com Timers GT5Y Switches & Pilot Lights GT5Y Series -- ON Delay Timers Key features: * * * * * * 4PDT, 3A or DPDT, 5A contacts 4 time ranges Repeat error 0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED indicators Uses the same sockets and hold-down clips as IDEC's RY4S and RU series relays Signaling Lights UL, c-UL Listed File No. E55996 Specifications GT5Y-2 Contact Form 4PDT Resistive Load 220V AC, 3A 30V DC, 3A Inductive Load 220V AC, 2A 30V DC, 2.5A 220V AC, 0.8A 30V DC, 1.5A Resistive Load 1100VA AC 150W DC 660VA AC 90W DC Inductive Load Cos o = 0.3 L/R = 7msec 440VA AC 75W DC 176VA AC 45W DC Rated Load Allowable Voltage Allowable Current Temperature Error 250V AC, 125V DC 5A 3A 3% maximum (over -10 to 50C, reference temperature 20C) Setting Error 10% maximum When turning power off after time up: 0.1 second maximum When turning power off before time up: 1 second maximum Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance Electrical Life Mechanical Life 100M minimum 2,000V AC, 1 minute (except between contacts of the same pole) 100N (approximate 10G) Operating extremes: 100N (approximate 10G) Damage limits: 500N (approximate 50G) 100V AC type: 1.5VA (at 50Hz) 200V AC type: 1.6VA (at 50Hz) 24V DC type: 0.9W 500,000 operations minimum (220V AC, 5A) Terminal Blocks Power Consumption Contactors Reset Time Timers DPDT 220V AC, 5A 30V DC, 5A Relays & Sockets 100 to 120V AC (50/60Hz) 200 to 240V AC (50/60Hz) 24V DC 24V AC 12V DC Rated Operating Voltage Allowable Contact Power GT5Y-4 200,000 operations minimum (110V AC, 3A) 50,000,000 operations minimum Operating Temperature -10 to +50C Operating Humidity 45 to 85% RH Circuit Breakers 1. Minimum applicable load: GT5Y-2: 5V DC, 20mA (reference value); GT5Y-4: 5V DC, 10mA (reference value). 2. Inductive load: cos o =0.3, L/R=7msec. 800-262-IDEC (4332) * USA & Canada 875 Timers Switches & Pilot Lights GT5Y Part Numbering List Mode of Operation Contact Output Rated Voltage 100 to 120V AC Signaling Lights 200 to 240V AC DPDT 220V AC/ 30V DC, 5A 12V DC Relays & Sockets 24V DC 24V AC ON-Delay 100 to 120V AC Timers 200 to 240V AC 4PDT 220V AC/30V DC, 3A 12V DC 24V DC Contactors 24V AC Time Range Complete Part No. 1S/10S/1M/10M GT5Y-2SN1A100 3S/30S/3M/30M GT5Y-2SN3A100 6S/60S/6M/60M GT5Y-2SN6A100 1S/10S/1M/10M GT5Y-2SN1A200 3S/30S/3M/30M GT5Y-2SN3A200 6S/60S/6M/60M GT5Y-2SN6A200 1S/10S/1M/10M GT5Y-2SN1D12 3S/30S/3M/30M GT5Y-2SN3D12 6S/60S/6M/60M GT5Y-2SN6D12 1S/10S/1M/10M GT5Y-2SN1D24 3S/30S/3M/30M GT5Y-2SN3D24 6S/60S/6M/60M GT5Y-2SN6D24 1S/10S/1M/10M GT5Y-2SN1A24 3S/30S/3M/30M GT5Y-2SN3A24 6S/60S/6M/60M GT5Y-2SN6A24 1S/10S/1M/10M GT5Y-4SN1A100 3S/30S/3M/30M GT5Y-4SN3A100 6S/60S/6M/60M GT5Y-4SN6A100 1S/10S/1M/10M GT5Y-4SN1A200 3S/30S/3M/30M GT5Y-4SN3A200 6S/60S/6M/60M GT5Y-4SN6A200 1S/10S/1M/10M -- 3S/30S/3M/30M GT5Y-4SN3D12 6S/60S/6M/60M -- 1S/10S/1M/10M GT5Y-4SN1D24 3S/30S/3M/30M GT5Y-4SN3D24 6S/60S/6M/60M GT5Y-4SN6D24 1S/10S/1M/10M GT5Y-4SN1A24 3S/30S/3M/30M GT5Y-4SN3A24 6S/60S/6M/60M GT5Y-4SN6A24 For sockets and accessories, see page 878. Timing Ranges Terminal Blocks Code 1S Time Range Indication Time Range x 0.1 S 0.1 second to 1 second x1 S 0.2 second to 10 seconds x 0.1 M 1.2 seconds to 1 minute 10M x1 M 12 seconds to 10 minutes 3S x1 S 0.1 second to 3 seconds x 10 S 0.5 second to 30 seconds x1 M 3 seconds to 3 minutes 10S 1M 30S Circuit Breakers Scale 3M 0 to 10 0 to 3 30M x 10 M 30 seconds to 30 minutes 6S x1 S 0.1 second to 6 seconds x 10 S 1 second to 60 seconds x1 M 6 seconds to 6 minutes x 10 M 1 minute to 60 minutes 60S 6M 0 to 6 60M 876 www.IDEC.com Timers GT5Y GT5Y-2 GT5Y-4 DPDT 4PDT Switches & Pilot Lights Timing Diagram/Schematics/Electrical Life Curves Internal Connections (bottom view) Delayed Contact 1 - 9, 2 - 10 3 - 11, 4 - 12 5 - 9, 6 - 10 7 - 11, 8 - 12 Operation (NC) (NO) Relays & Sockets POWER Indicator OUT For an explanation of timing modes, see page page 832. Electrical Life Curves 5000 AC Load 1000 Timers Life (x 10,000 operations) GT5Y-2 GT5Y-4 110V AC Resis. Load 220V AC Resis. Load 110V AC Induc. Load 220V AC Induc. Load 500 100 50 10 1 0 2 3 4 5 Contactors Load Current (A) 5000 DC Load GT5Y-2 GT5Y-4 30V DC Resis. Load 30V DC Induc. Load 100V DC Resis. Load 100V DC Induc. Load 1000 500 Terminal Blocks Life (x 10,000 operations) Operation Mode: ON-Delay Terminal Number 13 - 14 Signaling Lights Item Set Time Power 100 50 10 0 1 2 3 4 5 Load Current (A) Circuit Breakers 800-262-IDEC (4332) * USA & Canada 877 Timers Switches & Pilot Lights GT5Y Accessories DIN Rail Mounting Accessories DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Style Appearance Applicable Hold-Down Springs Part No. Appearance SY4S-05 Signaling Lights 14-Blade Screw Terminal Relays & Sockets Part No. SFA-202 14-Blade Screw Terminal (fingersafe) SY4S-05C DIN Mounting Rail Length 1000mm BNDN1000 Panel Mounting Accessories Part Numbers: Panel Mount Socket and Hold-Down Springs Panel Mount Socket Timers Style Appearance Contactors 14-Blade Solder Terminal Applicable Hold-Down Springs Part No. Appearance SY4S-51 Part No. SFA-302 PCB Mounting Accessories Part Numbers: PCB Mount Sockets with Applicable Hold-Down Springs PCB Mount Socket Style Appearance Applicable Hold-Down Springs Part No. Appearance Part No. SY4S-61 SFA-302 14 Blade, PCB Terminal SY4S-62 SY4S-02F1 Circuit Breakers Terminal Blocks 14 Blade, PCB Terminal 878 www.IDEC.com Timers GT5Y GT5Y Timer, Blade with SY4S-05 When using BAA/BAP: 28.5 30 0.7 When using DIN Rail When using BAA/BAP: 87.6 maximum 6 Holddown Spring 45 18.5 18.5 3 25 26 8 7 6 5 4 3 2 1 26 4 max. 4.2 DIN Rail Terminal Arrangement 25 4.8 min. 14 13 12 11 10 9 Signaling Lights 58.6 6.4 DIN Rail (BAA/BAP) 2-o4.2 Mounting Holes (or M4 Tapped Holes) 3 52.6 62 62 27.5 6 18 M3 Terminal Screw 83.6 maximum 21 Switches & Pilot Lights Dimensions (Top View) 5.9 max. o3.2 min. Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 879 Timers General Instructions for All Timer Series Load Current Vibration and Shock With inductive, capacitive, and incandescent lamp loads, inrush current more than 10 times the rated current may cause welded contacts and other undesired effects. The inrush current and steady-state current must be taken into consideration when specifying a timer. Excessive vibration or shocks can cause the output contacts to bounce, the timer should be used only within the operating extremes for vibration and shock resistance. In applications with significant vibration or shock, use of hold down springs or clips is recommended to secure a timer to its socket. Contact Protection Time Setting Switching an inductive load generates a counter-electromotive force (back EMF) in the coil. The back EMF will cause arcing, which may shorten the contact life and cause imperfect contact. Application of a protection circuit is recommended to safeguard the contacts. The time range is calibrated at its maximum time scale; so it is desirable to use the timer at a setting as close to its maximum time scale as possible. For a more accurate time delay, adjust the control knob by measuring the operating time with a watch before application. Temperature and Humidity Input Contacts Use the timer within the operating temperature and operating humidity ranges and prevent freezing or condensation. After the timer has been stored below its operating temperature, leave the timer at room temperature for a sufficient period of time to allow it to return to operating temperatures before use. Use mechanical contact switch or relay to supply power to the timer. When driving the timer with a solid-state output device (such as a two-wire proximity switch, photoelectric switch, or solid-state relay), malfunction may be caused by leakage current from the solid-state device. Since AC types comprise a capacitive load, the SSR dielectric strength should be two or more times the power voltage when switching the timer power using an SSR. Environment Avoid contact between the timer and sulfurous or ammonia gases, organic solvents (alcohol, benzine, thinner, etc.), strong alkaline substances, or strong acids. Do not use the timer in an environment where such substances are prevalent. Do not allow water to run or splash on the timer. Timers Relays & Sockets Signaling Lights Switches & Pilot Lights General Instructions Generally, it is desirable to use mechanical contacts whenever possible to apply power to a timer or its signal inputs. When using solid state devices, be cautious of inrushes and back-EMF that may exceed the ratings on such devices. Some timers are specially designed so that signal inputs switch at a lower voltage than is used to power the timer (models designated as "B" type). Timing Accuracy Formulas Contactors Timing accuracies are calculated from the following formulas: Repeat Error = 1 x Maximum Measured Value - Minimum Measured Value x 100% 2 Maximum Scale Value Voltage Error = Tv - Tr x 100% Tr Tv: Average of measured values at voltage V Tr: Average of measured values at the rated voltage Temperature Error = Tt - T20 x 100% T20 Setting Error = Average of Measured Values - Set Value x 100% Maximum Scale Value Circuit Breakers Terminal Blocks Tt: Average of measured values at C T20: Average of measured values at 20C 880 www.IDEC.com