Users should evaluate the suitability of this product for their application. Speci cations are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any speci cation, without noti cation to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 2
Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2013 Tyco Electronics Corporation,. All rights reserved.
TITLE SPECIFICATION CONTROL DRAWING 55PC0212
WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, MEDIUM WEIGHT, GENERAL PURPOSE, 600 VOLT 8-6-13 D
This speci cation sheet forms a part of the latest issue of Raychem Speci cation 55PC.
Date Revision
CONSTRUCTION DETAILS
PART
NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
CONDUCTOR DIAMETER
(in.)
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
DIAMETER
(in.) WEIGHT
(lbs/1000 ft.)
LOWER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
LOWER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
55PC0212-26-* 26 19 x 38 .0175 .0183 .0191 38.4 .0328 .0345 .0362 1.38 1.52
55PC0212-24-* 24 19 x 36 .0225 .0233 .0241 24.3 .0378 .0395 .0412 1.98 2.13
55PC0212-22-* 22 19 x 34 .0285 .0293 .0301 15.1 .0438 .0455 .0472 2.90 3.06
55PC0212-20-* 20 19 x 32 .0365 .0375 .0385 9.19 .0523 .0540 .0557 4.38 4.57
55PC0212-18-* 18 19 x 30 .0452 .0464 .0476 5.79 .0616 .0635 .0654 6.59 6.90
55PC0212-16-* 16 19 x 29 .0514 .0527 .0538 4.52 .0690 .0710 .0730 8.37 8.70
55PC0212-14-* 14 19 x 27 .0644 .0659 .0674 2.88 .0838 .0860 .0882 12.88 13.33
55PC0212-12-* 12 37 x 28 .0825 .0845 .0865 1.90 .1020 .1047 .1074 19.73 20.30
55PC0212-10-* 10 37 x 26 .1050 .1070 .1090 1.19 .1252 .1290 .1328 31.12 32.13
55PC0212-8-* 8 133 x 29 .158 .163 .169 .658 .188 .196 .203 56.8 59.9
55PC0212-6-* 6 133 x 27 .198 .205 .212 .418 .233 .242 .251 89.7 94.7
55PC0212-4-* 4 133 x 25 .250 .260 .268 .264 .300 .311 .322 146. 154.
55PC0212-2-* 2 665 x 30 .320 .330 .340 .170 .370 .383 .397 227. 240.
55PC0212-1-* 1 817 x 30 .360 .370 .380 .139 .410 .424 .438 278. 291.
55PC0212-0-* 0 1045 x 30 .395 .415 .425 .108 .449 .466 .483 343. 366.
CONDUCTOR - SILVER-COATED COPPER INSULATION - RADIATION - CROSSLINKED,
MODIFIED ETFE
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
COLOR: White preferred
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
INSULATION ELONGATION AND TENSILE STRENGTH:
Total Insulation,
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
INSULATION FLAWS:
Spark Test, 3.0 kV (rms)
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS: .008 in. (nominal) total insulation
SHRINKAGE: 230 ± 3°C for 1 hour, 0.125 inch (maximum) in 12 inches
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms)
PART NUMBER:
The “*” in the part numbers on page 1 shall be replaced by a color code designator.
1/ Example: AWG 22, white: 55PC0212-22-9
AWG 22, white with a black stripe: 55PC0212-22-90
1/ See footer section on page 1
SPECIFICATION CONTROL DRAWING 2 of 2 D 55PC0212
Revision SCD
Page