WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
Sensor & Wire-saving Link System
‘T’-branch Multi-drop
System Enabling
Flexible Cable Layout
26
Marked
Conforming to EMC Directive
(Except some components)
Till now
‘T’-branch S-LINK saves wires throughout the layout!
(Tree architecture)
Moreover, wiring and maintenance is significantly simplified.
Cylinder
Photoelectric sensor
Fiber sensor
Lamp
Solenoid
Limit switch
Manifold electromagnetic valve
Inductive proximity sensor
From now on
Many wires, high cost, and yet miswiring.
(Point-to-point wiring)
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
‘T’-branch
S-LINK
‘T’-branch Multi-drop
27
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Wire-saving
Three concepts of S-LINK
Quick
construc
tion
Space-effective
The use of wires is greatly
reduced and the number of
connecting terminal blocks
is minimized, resulting in
large reduction in cost, as
well as, the waste generat-
ed during wiring.
The layout of devices be-
comes flexible and the
design is easier due to the
‘T’-branch multi-drop wiring.
Since the wiring is simple,
miswiring is also sharply
decreased.
The time required for equip-
ment wiring is greatly reduced,
contributing to reduction in
electrical works cost.
Further, design and mainte-
nance personnel expenses
are also sharply decreased.
Sensors can be easily con-
nected with plug-in connec-
tion.
Connection by plug-in unit
Connection by connector
The addition of an I/O out-
put device is easy. Con-
struction can be done in
a short time.
The control box can be of
smaller size since connect-
ing terminal blocks are not
needed.
S-LINK devices are com-
pact. Hence, the control
box can be mounted in a
tight space.
It contributes to the minia-
turization of the machine
due to reduced wiring
space.
SL-FP3
SL-FP3
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Machinery
cost
Electrical
works
cost
Large cost
saving
Machinery
Electrical
works
cost
Construction
cost
7
6
5
4
3
2
1
0
S-LINK
28
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Address
display
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
‘T’-branch
multi-drop
Two signal lines
Two power lines
Max. 200m
Max. 128 I/Os
In case the cable breaks
here, the controller indi-
cates Address No.1.
Address
No.0 Address
No.1
The S-LINK system can be independently
operated without the PLC.
Checking inputs/
outputs is easy.
S-LINK Transmits 128 I/Os on Two Signal Lines and Realizes ‘T’-branch Multi-drop Wiring (Tree Architecture)
S-LINK enables transmission of 128 I/Os of sensors, switches, or actuators on two signal lines up to 200m (400m with the
booster). The S-LINK lines can be branched off in any direction, at any point, so that a flexible cable layout is possible. The
original SUNX signal processing enables highly reliable ‘T’-branch multi-drop wiring.
Caution: The connectable I/O number might decrease from 128 points depending upon the type of devices and their place of connection.
Since the S-LINK system can operate even when the
PLC is disconnected, the system construction time can be
drastically reduced by parallel development of the soft-
ware (PLC program) and the hardware (equipment
assembly, I/O device check). Further, in case of an error,
it can be immediately found whether the error is on the
PLC side or the I/O device side.
A handy monitor which can check I/O devices is available.
The handy monitor can be hooked up to the S-LINK sig-
nal transmission lines at any place. I/O states can be
checked in batches of 16. The handy monitor is also
incorporated with the S-LINK controller functions, so that,
for example, it can perform an I/O check on conveyor sys-
tem segments, still under assembly, even without the
S-LINK controller.
Easy Input/Output Check
The S-LINK system automatically
turns its power off when excess
current flows through the signal
lines due to a short-circuit.
The double code collation makes
the signal transmission secure
and reliable.
S-LINK’s unique signal transmis-
sion, large voltage amplitude (0 -
24V) and wide pulse width (35!s)
provide high noise immunity. The
signal transmission time is 5ms
approx. for 32 points, or 11ms
approx. for 128 points.
Highly Reliable Signal Transmission
The loop wiring maintains the sig-
nal transmission over the entire
system even if the loop may break
at any one place.
If the cable breaks somewhere, the
controller finds out the addresses
of all disconnected units, and dis-
plays their first address. Specify-
ing error addresses shortens the
repairing time.
S-LINK controller
SL-CU1A
Handy monitor
SL-HM1
Note: Although, SL-HM1 incorporates the functions of the SL-CU1A con-
troller, PLC I/O connectors cannot be connected.
SL-CU1A
29
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Suitable for Various PLCs
Connectable to terminal block type PLC
Multi-core cable PLC I/O units SL-S, SL-SP, SL-P, SL-PP
are connectable to terminal block type PLCs.
Easily connectable to different manufacturers’ PLCs
PLC I/O connectors SL-S, SL-Pare one-touch con-
nectable to different manufacturers’ PLC I/O modules.
Connectable PLC manufacturers
Matsushita Electric Works Mitsubishi Electric Corp. Omron Corp.
Yokogawa Electric Corp. Sharp Corp. Fuji Electric Works Hitachi
Yasukawa Electric Corp. Toshiba Corp. Toshiba Machine Co.
Suitable for Personal Computers
Suitable for PLC Bus
SL-CU1A
To S-LINK
system
I/O modules of different
manufacturers’ PLCs
PLC I/O connectors
I/O data
I/O data
Multi-core cable PLC I/O unit
Multi-core cableSL-CU1A
I/O modules of different
manufacturers’ terminal
block type PLCs
To S-LINK system
Direct connection to PLC bus
S-LINK controller for direct connection to Matsushita
Electric Works’ PLC FP3/FP10SH/FP10S bus line or
Yokogawa Electric’s PLC FA-M3 series bus line, and
S-LINK control boards for direct connection to the bus line
of Matsushita Electric Works’ board type PLC, FP-C or
Sharp’s board type PLC, J-board Z-300 series, are avail-
able. Since they incorporate the S-LINK control functions
and the PLC I/O connector functions, large cost and space
savings are achieved.
For VME bus
SL-VMES2
For Sharp J-board Z-300 series
SL-Z300
For Matsushita Electric
Works PLC FP-C
SL-FPC
For Yokogawa
Electric PLC
FA-M3 series
SL-FAM3
For PC/AT
SL-PCAT For PC/FC-98 series
SL-PC98
For Matsushita
Electric Works PLC
FP3/FP10SH/FP10S
SL-FP3
Direct connection to personal computers
As control by personal computers has spread in recent
years, S-LINK control boards for direct connection to PCI
bus, PC/AT and compatibles (ISA bus) and to NEC
PC/FC-98 series (C bus) have been developed, in order to
enable control of the S-LINK system by a personal com-
puter. Further, S-LINK control board for direct connection
to the VME bus line is also available. Flexibility in design
has been increasingly improved.
7
6
5
4
3
2
1
0
‘T’-branch
128 I/Os can be controlled by
just two signal lines
!
Loop wiring is also possible
!
POWERCPU
IN64
X
OUT64
Y
SL-SP3
S-LINK
controller
SL-FP3,
alone, is
sufficient
Module
for output
Module
for intput
PLC I/O connector
Two slots are
occupied
One slot is
occupied
This space is also
not necessary !
Construction using SL-FP3
Normal construction
In case Matsushita Electric Works PLC bus S-LINK
controller SL-FP3 is used.
POWERCPU
IN64
X
OUT64
Y
IN64
X
OUT64
Y
mPlease refer to P.44 for the connectable PLCs of each manufacturer.
For PCI
SL-PCI
S-LINK
30
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
7
6
5
4
3
2
1
0
SEND
SET
ADDRESS
OFF
CHK.
B0
B1
0 ~ 31
32~ 63
64~ 95
96~ 127
OFF
OUT
ON
RUN
IN
STAT.
SYS.
ADD.
ER1
ER3
BK
TE
1
0
32
16
8
4
2
1
BU
SHI.
WH
RD
ER4
OFF
ON
ID
S-LINK GATEWAY CONTROLLER
SL-GU1-D
N8Q05JAPAN
B
24
0
D
G
A
24
0
24
0
G
7
6
5
4
3
2
1
0
SEND
SET
ADDRESS
OFF
CHK.
B0
B1
0 ~ 31
32~ 63
64~ 95
96~ 127
OFF
OUT
ON
RUN
IN
STAT.
SYS.
ADD.
ER1
ER3
BK
TE
1
0
32
16
8
4
2
1
BU
SHI.
WH
RD
ER4
OFF
ON
ID
S-LINK GATEWAY CONTROLLER
SL-GU1-D
N8Q05JAPAN
B
24
0
D
G
A
24
0
24
0
G
Master unit made by different
PLC manufacturers
Suitable devices for different manufacturers’ fieldbus networks
Graphic panel Temperature controller etc.
S-LINK
gateway controller
Max. 128 I/O channels connectable per
S-LINK gateway controller
Sensor & wire-saving link system S-LINK
ON/OFF devices are
connected by quick
construction, wire-
saving S-LINK system
Easy connection and neat
wiring by ‘T’-branches
using hook-up connectors
High performance devices
are connected by wire-saving
fieldbus network
Compatible with Global Fieldbus Networks
Globally, fieldbus networks for FA are spreading rapidly to realize wire-saving connections between PLCs of different manu-
factures, or high performance devices, such as, temperature controllers, graphic panels etc. SUNX has developed gateway
controllers which enable connection of S-LINK to the fieldbus networks being used in different parts of the world. Hence,
wire-saving connections and other advantages of S-LINK can be realized even when using fieldbus networks.
For Device Net
SL-GU1-D For PROFIBUS-DP
SL-GU1-P For INTERBUS
SL-GU1-I For CC-link
SL-GU1-C For JPCN-1/RS-485
SL-CU1-485
JPCN-1/RS-485
Master board for
PC/FC-98 series
SL-PC98-485
31
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Seamless connection to fieldbus networks
S-LINK can be connected seamlessly to fieldbus networks
using the S-LINK gateway controllers.
Advanced wire-saving connection with S-LINK and
fieldbus networks
Wire-saving connections can be realized even when using
fieldbus networks. An efficient wire-saving network can be
implemented by connecting distributed bit level data I/O
devices, such as, sensors, switches, etc., by S-LINK.
Personal computer can be used as master (for JPCN-1/RS-485)
PC/AT or compatible (ISA bus), NEC PC/FC-98 series personal computer or PC/104 bus board can be used as a master
unit. Long distance and multi-point control is easily possible with a personal computer when the JPCN-1/RS-485 master
board and the S-LINK gateway controller for JPCN-1/RS-485, SL-CU1-485, are used.
The master boards for personal computers can be used in the following two modes:
1 S-LINK mode (using RS-485 communication)
2 JPCN-1 mode
(Please arrange a driver software separately, when using the JPCN-1 mode.)
m
Advantage of using with higher level networks
Long distance transmission
The max. transmission distance is as follows.
DeviceNet: 500m, PROFIBUS-DP and CC-Link: 1,200m,
INTERBUS: 13km, JPCN-1/RS-485: 1,000m.
S-LINK can transmit up to 400m using the booster
(SL-BS1A). Hence, a system of total 1,600m can be con-
structed with PROFIBUS-DP or CC-Link (DeviceNet:
900m, INTERBUS: 13.4km).
Total I/O channels 8,064 Nos.
Up to 99 Nos. of S-LINK gateway controllers can be con-
nected as slaves to one PROFIBUS-DP master unit
[DeviceNet: 63 Nos., INTERBUS: 256 Nos., JPCN-1/
RS-485: 31 Nos., CC-Link: 32 Nos. (Note 2)]. Since max.
128 Nos. I/O devices can be connected to one S-LINK
gateway controller, I/O signal of total 12,672 channels
[DeviceNet: 8,064 channels, INTERBUS: 4,096 channels
(Note 3), JPCN-1/RS-485: 3,968 channels, CC-Link:
2,048 channels (Note 2)] can be transmitted.
S
Since the higher level networks mostly use cascade wiring with
shielded twisted pair cable, the flexibility in wiring and wiring
operations have not improved. In S-LINK, ‘T’-branch flexible lay-
out can be realized using different types of quick connecting
hook-up connectors, and distributed ON/OFF data devices, such
as, switches, sensors, etc., can be efficiently wired. In this man-
ner, an exceedingly efficient wire-saving link system can be real-
ized in combination with higher level networks.
Notes: 1) The total No. of I/O channels may be less than the maximum No.
mentioned above depending on the master unit capacity. Also, the
No. of devices connectable to the S-LINK system may be less than
128 Nos., depending on the type of devices and places connected.
Notes: 2)
In case of the S-LINK gateway controller for CC-Link, the No. of
controllable I/O channels varies with the No. of units connected to
CC-Link.
Notes: 3) For INTERBUS, one master unit can control up to 4,096 I/O chan-
nels only.
Master board for personal computer
SL-PCAT-485
SL-PC98-485
SL-PC104-485
S-LINK gateway controller
SL-CU1-485
To S-LINK
system
Communication can be easily done in S-LINK mode.
(Communication can also be done in JPCN-1 mode.)
Direct hook-up!!
Master board for
PC/104 bus
SL-PC104-485
Master board for
PC/AT
SL-PCAT-485
S-LINK
32
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
1 Channel I/O Unit SL-CH1, SL-CH1-PN
I/O Unit Selectable According to the Application
2 Channel I/O Unit SL-CH21, SL-CH21-PN, SL-CH21K
Different devices can be simply connected at any place
SL-CH1(-PN) can be used as either an input unit or an output
unit by switch selection. Hence, a sensor, limit switch, etc., is
connectable when it is used as an input unit, and a relay,
lamp, etc., is connectable when it is used as an output unit. It
can be connected by a ‘T’-branch at any place on the S-LINK
cable.
Sensor or relay
It handles either the input signal from a
sensor or the output signal to a relay.
Sensor
or
Relay
Both input and output devices are connectable
SL-CH21(-PN) allows connection of one input and one out-
put device. It is useful for a mechanism using both input
and output devices.
SL-CH21K, isolation type for power supply remote control
function of NEC FA personal computer FC-98/FC98-NX
series, is also now available.
ApplicationApplication
Cylinder with electromagnetic valve
It handles both the input signal from a
cylinder switch and the output signal to
an electromagnetic valve.
Electromagnetic
valve
Cylinder switch
2 Channel Input Unit SL-CH20, SL-CH20-PN
Two input devices are connectable
SL-CH20(-PN) allows connection of two input devices, and
handles both signals. It contributes to cost-effectiveness if
you use several input devices.
Application
Sensor and limit switch
It handles two input signals from a sen-
sor and a limit switch, two sensors, or
two limit switches.
Limit switch
Sensor
2 Channel Output Unit SL-CH22, SL-CH22-PN
Two output devices are connectable: drive current 100mA max. each
SL-CH22(-PN) allows connection of two output devices,
and handles both signals. It can supply 100mA max. current
to each device, so that ordinary DC relays or solenoid
valves can be activated.
Beacon and relay
It handles two output signals to a bea-
con and a relay, two relays, or two sole-
noid valves.
Relay
Beacon
Application
I/O Arrayed Terminal Unit SL-TB, SL-TB-PN, SL-TBP, SL-TBP-PN, SL-TBP-TY
Screw-on terminal unit
Depending upon the model, 4 Nos., 8 Nos. or 16 Nos. of input/output devices
(NPN/PNP type) can be connected to the terminal units.
Further, since power supply terminals for the input/output devices have been incor-
porated on all terminal units, neat wiring is possible.
Output signal hold
The output arrayed terminal unit is incorporated with an output signal hold function,
which retains the output state just prior to an error on the signal transmission lines.
This limits the effect on an output device, should a failure occur.
Separate load power supply type output terminal is now available
Separate load power supply type output terminal SL-TBP-TY which enables forced
turning OFF of the output device connected to the output terminal without halting the
complete S-LINK system, by switching off the load power supply, in the event of the
output device failure, is now available.
33
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Analog I/O Arrayed Terminal Unit SL-TBAD4, SL-TBDA1
High resolution
A high resolution of 1/4,000 (12 bits) can be realized.
Fast data conversion
They have a fast data conversion time of 1ms approx., for analog to digital, or digi-
tal to analog.
Input range settable for each channel (SL-TBAD4)
In case of the analog input arrayed terminal unit SL-TBAD4, it is possible to set
the input range for each input channel. As the analog input range can be 4 to
20mA, 1 to 5V, 0 to 10V or10 to10V, it can be selected according to the out-
put of the connected analog device.
Environment Resistant I/O Unit SL-TW4, SL-TW4-PN, SL-TW8, SL-TW8-PN, SL-TW2P2, SL-TW2P2-PN, SL-TWP4, SL-TWP4-PN
Reliable design with IP67 protection
It has IP67 (IEC 60529) protection, which
makes it safe even against water splashes.
Besides wire-saving in equipment/machin-
ery which requires waterproofing, it can be
used to simplify construction at places
where so far ‘water-resistant boxcable
groundterminal block’, etc., were used.
Easy wiring with exclusive water-resistant connector
M12 composite 4-pin connectors having IP67 protection are available for connec-
tion of the main cable, branch cables or I/O devices.
Troublesome soldering is absolutely not required, and cables of I/O devices can be
connected simply by a screwdriver. Four types of composite male connectors are
available to suit the cable diameter of different I/O devices.
Further, a branch connector which can not only branch the main cable easily, but
can also connect a set of emitter/receiver of a thru-beam type photoelectric sensor
(1 set) as 1 input channel, is available.
‘T’-branch wiring and cascade wiring possible
Main cable and branch cable can not only be ‘T’-branched, but can also be cas-
cade wired.
Wide variety
Four types of units are available:
input unit (4 or 8 inputs), I/O unit
(2 inputs and 2 outputs), or output
unit (4 outputs).
<‘T’-branch wiring><
Cascade wiring>
IN
side IN
side
Cover for
M12 male
connector
(SL-WPK)
(Optional)
Cover for
M12 male
connector
(SL-WPK)
(Optional)
Branch connector
(SL-WY)(Optional) Branch connector
(SL-WY)(Optional)
IN
side
OUT/
LOCAL
PWR side IN
side
OUT/
LOCAL
PWR side
S-LINK
34
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
I/O Unit Selectable According to the Application
Relay Output Terminal Unit SL-TPR4, SL-TPR8
Output device control through
relays
These are 4 channel and 8 channel
relay output terminal units.
The integrated relay can drive AC
actuators up to 250V 2A.
Output signal hold
The relay output terminal unit is incor-
porated with an output signal hold
function, which retains the output
state just before an error occurs on
the signal transmission lines.
This lim-
its the effect on an output device,
should a failure occur.
On-board I/O Module SL-M, SL-MP
I/O interface for custom made PCB
These are IC type modules with external address setting switches and indicators.
The modules are available as vertical mounting type and horizontal mounting type.
Selection can be made depending upon the custom PCB design and the compo-
nent space available.
Mounted PCB illustration
Custom made printed circuit board
To S-LINK and
I/O devices
Terminal block
Horizontal mounting type
Vertical mounting type
8 Channel Snap-connector I/O Unit SL-T8J, SL-T8J-PN, SL-TP8J, SL-TP8J-PN
Output signal hold
The 8 channel snap-connector output
unit is incorporated with an output sig-
nal hold function, which retains the
output state just prior to an error on
the signal transmission lines. This lim-
its the effect on an output device,
should a failure occur.
Snap male connector
SL-CP1, for 0.08 to 0.2mm2conduc-
tors, SL-CP2, for 0.3mm2conductors,
and SL-CP3, for 0.5mm2conductors,
clamp the inner conductors of a
cable, and establish conduction sim-
ply by pressing, so that there is no
need to strip the wire insulation.
8 input devices or 8 output devices
are connectable
The slim and compact snap-connec-
tor I/O unit interfaces 8 input devices
or 8 output devices with the
S-LINK system. Its connections are
very easy with the snap male connec-
tors (optional).
7
6
5
4
3
2
1
0
35mm width
DIN rail
Snap male connector (Optional)
SL-CP1, SL-CP2 or SL-CP3
I/O device cable
8 channel snap-connector input unit SL-T8J(-PN)
8 channel snap-connector output unit SL-TP8J(-PN)
SL-CP1 or SL-CP2
I/O device cable
SL-CP3
I/O device cable
35
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
16 Channel MIL Connector I/O Unit SL-T16C1, SL-T16C1-PN, SL-TP16C1, SL-TP16C1-PN
16 I/Os connectable via a MIL connector
The slim and compact MIL connector I/O
unit connects 16 input/output devices to the
S-LINK system by a 20-pin MIL connector.
Matsushita Electric Works relay ter-
minals are connectable with MIL
connector cables (SL-T16C1 only)
RT2 relay terminal (AY23), PC relay
terminal (AY11)/PC terminal (AY10),
or CT-2 connector terminal (AYC)
manufactured by Matsushita Electric
Works are directly connectable via a
MIL connector cable as the pin
arrangements match.
35mm width
DIN rail (Optional)
20-pin MIL connector (male receptacle)
MIL-C-83503 conforming
AXM220001 manufactured by
Matsushita Electric Works
AXM120415 manufactured by
Matsushita Electric Works or equivalent
()
()
20-pin MIL connector
(female connector)(Optional)
20-core flat cable (Optional)
16 channel MIL connector input unit SL-T16C1(-PN)
16 channel MIL connector output unit SL-TP16C1(-PN)
RT-2 relay terminal manufactured by
Matsushita Electric Works (AY23)
16 inputs
or
16 outputs
Snap-connector Sensor Block SL-BMJ, SL-BXJ
Snap female connector
SL-CJ1, for 0.08 to 0.2mm
2
con-
ductors, and SL-CJ2, for 0.3mm
2
conductors, clamp inner conductors
of a cable, and establish conduction
simply by pressing, so that there is
no need to strip the wire insulation.
Combination with plug-in unit sensor blocks
The snap-connector sensor
block (main or extension) is com-
binable with the plug-in unit sen-
sor block (main or extension).
SL-BMJ can be followed by two
SL-BXs.
SL-BM can be followed by one
SL-BXJ.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Removable cover
Suitable for DIN rail
Operation
indicators
Extension connector
It can be ‘T’-branched on
the S-LINK cable
Input device cable
Extension block
SL-BXJ
Sensor main block
SL-BMJ
Snap female connector
SL-CJ1
(for 0.08 to 0.2mm2 conductors)
SL-CJ2
(for 0.3mm2 conductors)
124V
20V
3Sensing output
4Self-diagnosis output
()
Output signal hold
The 16 channel MIL connector output unit is
incorporated with an output signal hold func-
tion, which retains the output state just prior
to an error on the signal transmission lines.
This limits the effect on an output device,
should a failure occur.
Max. 16 input devices are connectable
The snap-connector sensor block (main or extension) interfaces maximum
16 input devices, such as, sensors or switches, to the S-LINK system. Their
connections are very easy with the snap female connectors (optional).
Plug-in Unit Sensor Block SL-BM, SL-BX
Photoelectric
sensor Inductive proximity
sensor Limit switch
Max. 16 sensors are connectable
One plug-in unit sensor main block can be followed by
max.
three extension blocks, so that max. 16 plug-in units are
connectable.
Plug-in units
The following sensor units can be
plugged in on the sensor block.
Plug-in units
Fiber sensor
Digital setting (Note1)
FX-D1J (Red LED)
Auto-setting
FX-A1J (
Red LED
)
FX-A1GJ
(
Green LED
)
Manual setting
FX-M1J (
Red LED
)
FX-M1GJ
(Green LED)
Various input devices
are connectable
Input terminal unit (Note 2)
SL-TJ1
Amplifier-separated
inductive proximity
sensor
GA-14J
GA-15J
Amplifier-separated
photoelectric sensor
SU-7J
The sensor blocks can generate
the ORed self-diagnosis output of
all the connected sensors. But, in
this case, the first channel of the
sensor main block gets occupied.
Sensor main block
(SL-BM)
Extension block (SL-BX)
Max. three extension
blocks are connectable.
( )
Notes: 1) In case the digital setting fiber sensor FX-D1J is connected to the plug-in unit sensor block, Output 2 cannot be used.
Notes: 2) PNP output type sensor cannot be connected to input terminal unit SL-TJ1.
I/O Unit Selectable According to the Application
S-LINK
36
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
S-LINK Direct Hook-up Photoelectric Sensor SL-A
Direct hook-up to S-LINK cable
The sensor SL-Acan be hooked up to the
S-LINK cable without any interface.
No interference
A total of 128 sensors can be connected in
one S-LINK system without any interfer-
ence.
Note: If sensors are mounted next to each other, their
addresses should be separated by 4, or more.
Booster SL-BS1A
Cable extension to total 400m
The booster extends the S-LINK cable by 200m, to a total 400m length. Loop wiring is
also possible beyond the booster.
Controller
Booster
Booster
Booster
1Total 400m in series
2200m extension from a branch point
3Satellite loops around main loop
Controller Booster
200m 200m
Controller
200m
Booster
200m
Booster
200m
Booster
200m
Notes: 1) Cable extension may not be possible depending on the type and number of I/O devices connected.
Notes: 2) A maximum of seven boosters can be connected for one S-LINK control unit. However, one
booster can never be followed by another booster in series.
S-LINK Direct Hook-up Area Sensor SL-N15
Direct hook-up to S-LINK cable
The area sensor SL-N15 can
be hooked up to the S-LINK
cable without any interface.
Conventionally, NA1-5 has
been interfaced by SL-CH21
with three branch points, but
SL-N15 allows you to hook up
the emitter and the receiver to
the S-LINK cable, without any
interface.
SL-CH21
I/O
SIDE
IN :G
OUT :R
SEND
ON
NOT
USED
ADDRESS
32
16
8
4
2
1
64
OFF
X
SUNX
SL-CH21
SL-N15
NA1-5
One-touch hook-up
at any place.
Conventional
SL-N15
All four types are available
10m (Infrared)
30m (Infrared)
5m
(Red, with polarizing filters)
700m (Infrared)
Thru-beam type
Retroreflective type
Diffuse reflective type
SL-A11, SL-A13
SL-A19
SL-A12
37
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Simple hook-up
No need to connect a cable on a terminal with screws.
Wire insulation stripping, and crimp contact fitting have
been inevitable until the S-LINK hook-up connector was
introduced. Using the hook-up connector saves your time
and space, and enables a flexible cable layout.
Cable end connector optimum for cable termination available
When cabtyre cable is used as the main cable, the end connector can be easily connected.
Socket-branch hook-up connector SL-JK and SL-JK1
By connecting the socket-branch hook-up connector SL-JK
and SL-JK1 to the S-LINK
cable and using the snap male con-
nector SL-CP, S-LINK devices can be connected very easi-
ly. They can also be disconnected easily when required.
S-LINK Hook-up Connector SL-J1A, SL-JK, SL-JK1, SL-J3A, SL-JE, SL-JE-RC
S-LINK branch cable
Cover
Housing
Cover
S-LINK
main cable
Just hook-up both
covers, each
holding an S-LINK
cable, and the
housing together.
mUse exclusive S-LINK cables.
Illustration of connected S-LINK devices
SL-CP2 (Black)
()
Sensor block SL-BM
Sensor block SL-BMJ
S-LINK direct hook-up
photoelectric sensor
SL-A
SL-JK1 (Blue)
(for T-branch)
for 0.3mm2
conductors
Simple Construction
S-LINK exclusive cabtyre cable
(SL-CBM100, SL-CBM200)
Junction terminal block
(commercial product)
2 channel I/O unit
SL-CH21
Cable attached
end connector
(SL-JE-RC)
I/O arrayed terminal unit (SL-TB, SL-TBP)
Cable attached
end connector
(SL-JE-RC)
S-LINK exclusive cabtyre cable (SL-CBM100, SL-CBM200)
Wire clamping in a snap
SL-CJ1, for 0.08 to 0.2mm2conductors, and SL-CJ2, for
0.3mm2conductors, are used with SL-BMJ or SL-BXJ.
SL-CP1, for 0.08 to 0.2mm2conductors, SL-CP2, for
0.3mm2conductors, and SL-CP3, for 0.5mm2conductors,
are used with SL-T8J(-PN) or SL-TP8J(-PN) I/O unit and
SL-JK or SL-JK1 hook-up connector. Further, if SL-CP3 is
used, S-LINK I/O devices can be easily connected/discon-
nected from the main/branch cable. Moreover, 2-pin type
hook-up female connectors SL-CJ12 (for 0.08 to 0.2mm2),
SL-CJ22 (for 0.3mm2) and 2-pin type hook-up male con-
nectors SL-CP12 (for 0.08 to 0.2mm2), SL-CP22 (for
0.3mm2) are also available for extension of 2-wire I/O
devices. Wire clamping is easy. Just insert wires of the
cable into the specified holes of the connector and press.
There is no need to strip the wire insulation.
Snap female connector
Snap male connector
Fastening of hook-up connector is simple and reliable
The S-LINK exclusive pliers make wiring with hook-up con-
nectors simple and reliable.
The spring slide-back mechanism improves the productivi-
ty. Ratchet mechanism type SL-JPD is also available.
Snap Connector SL-CJ1, SL-CJ2, SL-CJ12, SL-CJ22, SL-CP1, SL-CP2, SL-CP3, SL-CP12, SL-CP22
S-LINK Exclusive Pliers SL-JPS, SL-JPD, SL-JPE, SL-JPC
<4-pin type><4-pin type>
<2-pin type><2-pin type>
SL-CJ1 or SL-CJ2
I/O device
cable
SL-CP1 or SL-CP2
I/O device
cable
SL-CP3
I/O device
cable
SL-CJ12 or SL-CJ22
I/O device
cable
SL-CP12 or SL-CP22
I/O device
cable
S-LINK
38
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Easy wiring with exclusive water-resistant connector
M12 composite 4-pin connectors having IP67 protection
are available for connection of the main cable, branch
cables or I/O devices.
Troublesome soldering is absolutely not required, and
cables of I/O devices can be connected simply by a
screwdriver. Four types of composite male connectors are
available to suit the cable diameter of different I/O
devices.
Further, a branch connector which can not only branch the
main cable easily, but can also connect a set of
emitter/receiver of a thru-beam type photoelectric sensor
(1 set) as 1 input channel, is available.
Water-resistant Connector SL-WP4, SL-WP5, SL-WP6, SL-WP8, SL-WJ8, SL-WY, SL-WE
Easy input/output check
A handy monitor which can check I/O devices is available.
The handy monitor can be hooked up to the S-LINK sig-
nal transmission lines at any place. I/O states can be
checked in batches of 16. The handy monitor is also
incorporated with the S-LINK controller functions, so that,
for example, it can perform an I/O check on conveyor sys-
tem segments, still under assembly, even without the
S-LINK controller.
Handy Monitor SL-HM1
Simple Construction
<Composite male connector>
SL-WP4:
Suitable cable diameter
"3 to "4mm
SL-WP5:
Suitable cable diameter
"4 to "5mm
SL-WP6:
Suitable cable diameter
"5 to "6mm
Branching of main/branch cable possible
A branch connector which can be used to branch the
main/branch cable is available. Moreover, it can connect a
set of emitter/receiver of a thru-beam type photoelectric
sensor as 1 channel.
<Branch connector>
SL-WY
Environment resistant end connector available
It is used when the environment resistant I/O unit SL-TW
is connected at the end of the main cable.
<Environment resistant end connector>
SL-WE
IP67 4-pin
IP67 4-pin
<Composite female connector>
SL-WJ8:
Suitable cable diameter
"6 to "8mm
SL-WP8:
Suitable cable diameter
"6 to "8mm
Note: Although SL-HM1 incorporates the functions of the SL-CU1A con-
troller, PLC I/O connectors cannot be connected.
IP67 4-pin
IP67 4-pin
IP67 4-pin
No. of control points: S-LINK 128 pointsNormal wiring 96 points
On the S-LINK side 64 inputs and 64 outputs (fixed), a total
of 128 points can be controlled and, by adding 3 Nos. of I/O
modules, a max. of 96 points can be controlled by normal
wiring.
FP0-SL1 manufactured by Matsushita Electric Works
Extremely small, large cost reduction
The CPU unit of the PLC (programmable logic controller),
I/O module, PLC I/O connector and the S-LINK controller
functions are incorporated in an extremely small body of
W30H90D60mm. The space required is greatly
reduced and compactness can be achieved.
Further, large cost reduction can also be realized.
39
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Manifold Electromagnetic Valves Suitable for S-LINK
‘T’-branch connection manifold electromagnetic valves
Manifold electromagnetic valves capable of direct ‘T’-
branch connection to the S-LINK cable are available from
Koganei Corp., SMC Pneumatics and CKD Corp.
Please contact Koganei Corp. (Humphry Products Company in
U.S.A. and Canada), SMC Pneumatics or CKD Corp. for details.
Controllers Suitable for S-LINK
Controllers for S-LINK released by other companies!!
Matsushita Electric Works, Mitsubishi Electric Corp., and
Toyoda Machine Works have released controllers incorpo-
rating S-LINK controller functions so that the S-LINK sys-
tem can be controlled without a separate S-LINK con-
troller.
Limit Switches Suitable for S-LINK
Direct connection of limit switches to S-LINK system!!
Limit
switches which can be directly connected to the
S-LINK system transmission line by ‘T’-branch connection
are available from Matsushita Electric Works.
Please contact Matsushita Electric Works for details.
Matsushita
Electric Works Mitsubishi
Electric Corp. Toyoda
Machine Works
Koganei Corp. CKD Corp. SMC Pneumatics
Please contact Matsushita Electric Works, Mitsubishi Electric
Corp., and Toyoda Machine Works for details.
Matsushita Electric Works
S-LINK Family Products: Launched One After Another
S-LINK
40
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Use of flexible cable for moving equipment
Extremely effective in
wire-saving with movable
equipment.
Sensor
Sensor
Sensor
Sensor
Personal computer
Distributed Installation
Booster
S-LINK direct hook-up
photoelectric sensor Booster
PLC
S-LINK
controller
2 channel
input unit
S-LINK
hook-up
connector
Manifold
electromagnetic
valves suitable for
S-LINK
1 channel
I/O unit
(output usage)
24V DC
power supply
2 channel I/O unit
PLC I/O connectors
In a product transportation equip-
ment, there are many input and
output devices spread over various
places. Although wire-saving has
always been desired to reduce the
cost and shorten the time of instal-
lation, long distance transmission
and product reliability are essential.
S-LINK allows a cable length of
200m, normally, and 400m along with
a booster. The double code collation
check plus high noise immunity
enable signal transmission reliability.
Furthermore, the S-LINK tree wiring
architecture enables you to branch off
sub-trunk lines or branch lines and
hook-up input and output devices,
anywhere you like. Test and installa-
tion block-by-block, and layout change
after installation are quite simple jobs.
Parking garage AGV
The S-LINK system is very suitable to wire up car detection
sensors in a large parking garage.
It reduces wires and installation time.
The signal transmission to AGV from a stationary controller has been very difficult.
As the S-LINK system allows use of commercial cables in the system, the AGV
equipped with the sensors and actuators can be linked with the stationary controller
via one flexible cable. Besides, the S-LINK alarm capability, that generates an error
output for a cable break, enables quick repair and ensures the system reliability.
Conveyor
Easy hook-up
APPLICATIONS
This product does not possess control functions
needed for accident prevention or safety mainte-
nance. Handle safety related or emergency stop sig-
nals without passing them through the S-LINK sys-
tem due to fail-safe considerations.
41
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
PLC 1 channel
I/O unit (input usage)
S-LINK
hook-up
connector
Sensor blocks
with fiber sensors
Snap-connector
sensor blocks
Output arrayed terminal unit
S-LINK controller
Manifold
electromagnetic valves
suitable for S-LINK
24V DC
power supply
PLC I/O connector
2 channel I/O unit
Input arrayed terminal unit
2 channel
output unit
APPLICATIONS
Automatic assembly machine
In an automatic assembly machine,
there are many input and output
devices distributed in various tight
spaces. As the machine becomes
more complex, the task of reducing
the cable volume becomes more dif-
ficult. Wire-saving is the primary
requirement, but reliability of signal
transmission is also indispensable.
In the S-LINK loop wiring, the system
maintains signal transmission even
when the loop may break at any one
place. In the S-LINK standard wiring,
the controller reveals disconnected
device addresses when the signal
transmission line may break. Further,
even if excess current may flow by a
short-circuit between the signal
transmission lines, the controller
shuts down the entire system.
Plug-in connection
Parts delivery systemHandler
An IC handler uses many sensors. The S-LINK system
contributes in reducing wires in order to miniaturize the
machine.
In a parts-taking verification system, the parts shelves are
equipped with a number of area sensors at the front. The
inputs equal the number of shelves and if job indicators are
used, there are an equal number of outputs.
The S-LINK system wires up all the area sensors with
effective space and wire saving.
Integrated Installation
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
42
S-LINK
‘T’-branch Multi-drop
7
6
5
4
3
2
1
0
Others
‘T’-branch multi-drop
wiring system
is the trademark of S-LINK.
1
2
1
2
1
2
1
2
Custom PCB
I/O modules
D
24
B
0
G
24
0
D
G
24
0
A
IN
SL-CP
SL-CJ
SL-J1A
SL-JE-RC
SL-JE
SL-CP3
SL-J3A
SL-JK
1234
7
6
54
3
21
0
64
3216
8
4
2
11248
163264
891011121314
01234567
SEND
ER1ER3ER4
DEC.(0l127)
HEX.(0l7F)
ADDRESS
UNIT COUNT
DISP.SELECT
SETINCREMENT
ADDRESS
ON
TOP ADDRESS
ON
TOP ADDRESS
OUTPUT MONITORDATA ON/OFF
ON
OUTPUT MONITORDATA ON/OFF
ON
DISABLE(OFF)
INPUT
OUTPUT
GD
0V24V24V
0V
8910111213141515
HANDY MONITOR
SL-HM1
ADDRESS
I/O TEST
(BK)(WH)(BU)(BN)
CONTROL
CONTROL
CONTROL
I/O CHECK
N)
EN
Plug-in to PLC I/O modules
Use multi-core cable PLC I/O connectors when terminal
block type PLC is used for control.
Multi-core cable
PLC input unit
SL-S
Multi-core cable
PLC output unit
SL-P
Multi-core cable PLC
input unit (PNP)
SL-SP
Multi-core cable PLC
output unit (PNP)
SL-PP
PLC input connector
SL-S
S-LINK controller
SL-CU1A
PLC output connector
SL-P
Slot-in to MEW FP3/FP10S(H) series
FP3, FP10S, FP10SH series
Matsushita Electric
Works PLC bus
S-LINK controller
SL-FP3
Yokogawa Electric
PLC bus S-LINK
controller
SL-FAM3
S-LINK suitable controllers
FP0-SL1, FP2-SL2, FP2-C1SL
Supplied by Matsushita
Electric Works.
Matsushita Electric
Works PLC bus
S-LINK control board
SL-FPC
PC/AT S-LINK
control board
SL-PCAT
PCI bus S-LINK
control board
SL-PCI
NEC PC/FC-98
series S-LINK
control board
SL-PC98
VME bus S-LINK
control board
SL-VMES2
Transmission distance
extended from 200m to 400m
Booster
SL-BS1A
Further
200m
S-LINK direct
hook-up area sensor
SL-N15
S-LINK direct hook-up
photoelectric sensor
SL-A
Power supply
24V DC
10%
S-LINK exclusive
flat cable
S-LINK exclusive cabtyre cable
SL-RCM100/RCM200
4-core flat cable which can be easily
‘T’-branched.
SL-CBM100/CBM200
Connectors
Various S-LINK connectors
for simple cable connections.
I/O modules
SL-M8(F) (8 inputs)
SL-M16(F) (16 inputs)
SL-MP8(F) (8 outputs)
SL-MP16(F) (16 outputs)
SL-M4P4(F)
(4 inputs and 4 outputs)
I/O modules mountable
on your custom PCB.
Handy monitor
SL-HM1
S-LINK handy monitor performs
I/O check by connecting to any
point on the main/branch cable.
Further, it is also equipped with
S-LINK controller functions.
Local power supply
S-LINK control unit
S-LINK input devices
S-LINK output devices
Sharp PLC bus
S-LINK control board
SL-Z300
Direct hook-up sensors
Cables Other S-LINK devices
OUTOUT
8 inputs are connectable.
IN IN IN IN
IN IN IN IN
OUT OUT OUT OUT
OUT OUT OUT OUT
8 outputs are connectable
OUT OUT OUT OUT
OUT OUT OUT OUT
OUT OUT OUT OUT
OUT OUT OUT OUT
16 outputs are connectable
8 channel snap-
connector output unit
SL-TP8J
SL-TP8J-PN
16 channel MIL
connector output unit
SL-TP16C1
SL-TP16C1-PN
2 channel
output unit
SL-CH22
SL-CH22-PN
OUT OUT
2 outputs are
connectable
Supplied by Koganei Corp.,
SMC Corp. and CKD Corp.
S-LINK direct hook-up manifold
electromagnetic valves
Relay output terminal unit
SL-TPR4
SL-TPR8
Environment resistant I/O unit
Output arrayed terminal unit
SL-TBP
SL-TBP-PN
SL-TBP-TY
4 outputs, 8 outputs, 16 outputs
Selectable from 4, 8 or
16 output models.
1 channel
I/O unit
SL-CH1
SL-CH1-PN
OUT
IN
OUT
2 outputs
IN
2 inputs
OUT
IN
OR
IN IN
2 inputs are connectable
Maximum 16
inputs can be
plugged in.
Plug-in unit
sensor main block
SL-BM
Fiber sensor
Amplifier-separated
photoelectric sensor
Amplifier-separated
inductive proximity sensor
Input terminal unit
Plug-in units (4 units per block)
SL-TJ1
GA-14J, GA-15J
SU-7JFX-J
Plug-in unit
extension block
SL-BX
8 inputs are connectable.
IN IN IN IN
IN IN IN IN
Snap-connector
extension block
SL-BXJ
S-LINK direct hook-
up limit switch
Supplied by Matsushita
Electric Works.
IN IN IN IN
IN IN IN IN
IN IN IN IN
IN IN IN IN
16 inputs are connectable
16 channel MIL
connector input unit
SL-T16C1
SL-T16C1-PN
8 channel snap-
connector input unit
SL-T8J
SL-T8J-PN
8 inputs are connectable.
IN IN IN IN
IN IN IN IN
Maximum 16 inputs
can be connected.
Snap-connector
sensor main block
SL-BMJ
2 channel
I/O unit
SL-CH21
SL-CH21-PN
SL-CH21K
Environment resistant output unit
Analog output arrayed
terminal unit
SL-TBDA1
4 outputs, 8 outputs
Selectable from 4 or
8 output models.
Analog input arrayed
terminal unit
SL-TBAD4
Input arrayed
terminal unit
SL-TB
SL-TB-P
OUT
4 outputs
OUT
1 output
2 channel
input unit
SL-CH20
SL-CH20-PN
IN 4 inputs
IN
4 inputs, 8 inputs, 16 inputs
Selectable from 4, 8
or 16
in
put models.
Either 1 output
or 1 input is
connectable
1 output and 1 input,
total 2 I/Os are
connectable.
SL-TWP4, SL-TWP4-PN
SL-TW2P2, SL-TW2P2-PN
Maximum 3 plug-in unit
extension blocks can
follow 1 plug-in unit
sensor main block.
( )
Environment resistant input unit
SL-TW4, SL-TW4-PN
SL-TW8, SL-TW8-PN
IN 4 inputs, 8 inputs
Selectable from 4 or 8
in
put models.
IN
OUT
Indicates an
input device
Indicates an
output device
()
()
The number of and shows the number of
connections that can be made to that device.
Note: Please refer to P. 30, 31 for products compatible
with fieldbus networks
OUT
IN
S-LINK is a wire-saving system which
allows connection to max. 128 I/O
devices by using one controller.
S-LINK SYSTEM CONFIGURATION EXAMPLE
Limit switch, photoelectric
sensor, inductive proximity
sensor, push-button switch,
cylinder switch, etc.
Lamp, buzzer, relay, electro-
magnetic valve, solenoid, etc.
SL-E
SL-F70
SL-F150
SL-F250
SL-F1000
SL-C1000
SL-C2000
SL-C5000
SL-C2000F
SL-S1
SL-S2
SL-S3
SL-S4
SL-S5
SL-S6
SL-S7
SL-P1
SL-P2
SL-P3
SL-P4
SL-P5
SL-P6
PLC
PLC I/O connectors
End
connector
Cascade cable
Control
cable
()
Max. four PLC I/O
connectors can be
cascaded with one
S-LINK controller.
PLC input connectors
PLC output connectors
(same shape)
The listed PLC I/O mod-
ules (NPN only) allow the
mating PLC I/O connec-
tor to be plugged on
them for signal transmis-
sion between the PLC
and the S-LINK con-
troller.
The PLC I/O connec-
tor converts I/O data
from serial to parallel,
and vice versa.
I/O points: 32 points
per connector
Matsushita
Electric Works
Toshiba
Machine Co.
Fuji Electric Co.
Mitsubishi
Electric
Corp.
Sharp Corp.
Omron Corp.
Yokogawa
Electric Corp.
Toshiba Corp.
Yasukawa Electric
Corp.
Hitachi
Yasukawa Electric
Corp.
FP3, FP10S
FP10SH
TC200
NS series
F55
F70
F80H,
F120H
F120S
F140S, F15XS
AnS
AnN, AnA, AnU
QnA, QnAs
A2CJ
JW20, JW20H
JW30H
JW50H
CVM1,CV,C500
C1000H,C2000H
C200H series
CQM1
FA500
FA-M3
T3
GL20,GL40S,GL60S
GL60H,GL70H
H series
GL20,GL40S,GL60S
GL60H,GL70H
AFP33027
TC64DI
NS-X64-1
NS-XY64-1 (X side)
NV1X3204
NV1X3204-W
NV1X3206
NC1X3204
NC1X3204-3
NC1X3206
NC1X6404
NC1X6406
NC1W6406T(X side)
FTU125A
FTU126A
FTU127C
FTU612A (X side)
A1SX41
A1SX42
A1SH42 (X side)
AX42
AH42 (X side)
AJ35TC1-32D
JW-234N
JW-264N
JW-34NC
JW-64NC
C500-ID219
C200H-ID216
C200H-ID217
CQM1-ID213
XD64-6N
WD64-6N (X side)
F3XD32-3N
F3XD64-3N
DI-335
DI-335H
XDC24D2H
B2605
AFP33487
TC64DON
NS-Y64-T1
NS-XY64-1 (Y side)
NV1Y32T05P1
NC1Y32T05P1
NC1Y64T05P1-1
NC1W6406T(Y side)
FTU222A
FTU227C
FTU612A (Y side)
A1SY41
A1SY42
A1SH42 (Y side)
AY42
AH42 (Y side)
AJ35TC1-32T
JW-232S
JW-262S
JW-32SC
JW-62SC
C500-OD213
C200H-OD218
C200H-OD219
CQM1-OD213
YD64-1A
WD64-6N (Y side)
F3YD32-1A
F3YD64-1A
DO-335
B2604
YTR24DH
Designation Appearance (Note1) Model No. Description
For input For output Manufacturer PLC
PLC input PLC output
module (Note 4) module (Note 4)
It must be connected at the end of the last PLC
I/O connector.
It links two PLC I/O con-
nectors.
It links the S-LINK con-
troller and the first PLC
I/O connector.
S-LINK
44
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
ORDER GUIDE
PLC related units
Control cable
Cascade
cable
End connector
Length: 70mm
Length: 150mm
Length: 250mm
Length: 1,000mm
Length: 1m
Length: 2m
Length: 5m
Length: 2m
Notes: 1) Components with ‘ ’ mark conform to the CE marking EMC Directive.
However, note that for the PLC I/O connectors to conform to CE marking EMC Directive, it is necessary to use cascade cable SL-F70, SL-F150 or
SL-F250 and control cable SL-C2000F.
Notes: 2) The PLC I/O connectors use Fujitsu connectors. However, SL-S1, SL-P1, SL-S6 and SL-P6 connectors use MIL connectors.
Notes: 3) PLC I/O connectors are connectable to S-LINK controller SL-CU1A only.
Notes: 4) X side and Y side indicate the input and the output connectors, respectively, of the compound input/output module.
PLC input
connector
PLC output
connector
(Note 2, 3)
Fujitsu con-
nector specs. MIL connec-
tor specs.
Designation Appearance (Note) Model No. Description
Multi-core
cable PLC
I/O unit
NPN typePNP type
Multi-core
cable
For input For output
SL-S SL-P
SL-SP SL-PP
SL-L2000F
The multi-core cable PLC I/O unit, connectable with
any type of screw-on terminal type PLC I/O module via
the multi-core cable, interfaces I/O data between the
S-LINK controller and PLC.
It includes the I/O data conversion circuit for serial to
parallel or parallel to serial conversion.
I/O points: 32 points per unit
Connection to screw-on terminal type PLC is by an
optional multi-core cable attached with an MIL connec-
tor on one end.
The multi-core cable attached with an MIL
connector on one end links the multi-core
cable PLC I/O unit to a screw-on terminal
type PLC I/O module.
Length: 2m
Multi-core
cable
Multi-core cable
PLC I/O unit
PLCPLC
45
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
ORDER GUIDE
PLC related units
Note: Components with ‘ ’ mark conform to the CE marking EMC Directive.
However, note that for the multi-core cable PLC I/O units to conform to CE marking EMC Directive, it is necessary to use cascade cable SL-F70, SL-F150
or SL-F250, control cable SL-C2000F and multi-core cable SL-L2000F.
S-LINK control units
Designation Appearance (Note) Model No. Description
SL-CU1A
SL-VMES2
SL-PCI
SL-PCAT
SL-PC98
SL-FP3
SL-FAM3
SL-FPC
SL-Z300
It supplies the synchronization signal to the complete system to send and
receive I/O data from external devices correctly. It also monitors the signal
transmission line, and specifies the addresses of the disconnected devices if
the line breaks, etc.
S-LINK controller
VME bus S-LINK
control board
PCI bus S-LINK
control board
NEC PC/FC-98
series S-LINK
control board
PC/AT S-LINK
control board
Matsushita Electric
Works PLC bus
S-LINK controller
Sharp PLC bus
S-LINK control
board
Matsushita Electric
Works PLC bus
S-LINK control board
Yokogawa Electric
PLC bus S-LINK
master unit
It can be fitted into the expansion slot (ISA bus) of PC/AT series or compatible
to control the S-LINK system
.
By using this control board, the SL-CU1A controller, the PLC I/O connec-
tors, and their link cables are not required.
( )
It can be directly connected to the bus line of the FP3, FP10S or FP10SH series
PLCs manufactured by Matsushita Electric Works to control the S-LINK system.
By using this controller, not only the SL-CU1A controller, the PLC I/O
connectors, and their link cables, but also the PLC I/O modules are not
required.
(
It can be directly connected to the VME bus line to control the S-LINK sys-
tem. It provides two S-LINK ports, each allowing 128 I/O points maximum,
so that a total of 256 I/O points can be controlled.
By using this control board, the SL-CU1A controller, the PLC I/O connec-
tors, and their link cables are not required.
It can be directly connected to the bus line of the FA-M3 PLC manufactured
by Yokogawa Electric to control the S-LINK system.
By using this master unit, not only the SL-CU1A controller, the PLC I/O
connectors, and their link cables, but also the PLC I/O modules are not
required.
( )
It can be fitted into the expansion slot (PCI bus) of a personal computer
to
control the S-LINK system
.
By using this control board, the SL-CU1A controller, the PLC I/O connec-
tors, and their link cables are not required.
( )
It can be fitted into the expansion slot (C bus) of NEC PC/FC-98 series to
control the S-LINK system.
By using this control board, the SL-CU1A controller, the PLC I/O connec-
tors, and their link cables are not required.
( )
It can be directly connected to the bus line of the FP-C PLC manufactured by
Matsushita Electric Works to control the S-LINK system.
By using this control board, not only the SL-CU1A controller, the PLC I/O
connectors, and their link cables, but also the PLC I/O modules are not
required.
( )
)
( )
It can be directly connected to the bus line of the J-board Z-300 series PLC
manufactured by Sharp to control the S-LINK system.
By using this control board, not only the SL-CU1A controller, the PLC I/O
connectors, and their link cables, but also the PLC I/O modules are not
required.
( )
Note: Components with ‘ ’ mark conform to the CE marking EMC Directive.
S-LINK I/O devices
SL-GU1-D
SL-GU1-P
SL-GU1-I
SL-GU1-C
S-LINK
46
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
ORDER GUIDE
Products for fieldbus network
S-LINK gateway
controller for
DeviceNet
S-LINK gateway
controller for
PROFIBUS-DP
S-LINK gateway
controller for
INTERBUS
S-LINK gateway
controller for
CC-Link
S-LINK gateway
controller for
JPCN-1/
RS-485
JPCN-1/RS-485
master board for
PC/AT
JPCN-1/RS-485
master board for
PC/FC-98 series
JPCN-1/RS-485
master board for
PC/104 bus
SL-CU1-485
SL-PCAT-485
SL-PC98-485
SL-PC104-485
S-LINK gateway controller for connection to open network DeviceNet, widely
used in the United States.
S-LINK gateway controller for connection to open network PROFIBUS-DP,
widely used in Europe.
S-LINK gateway controller for connection to open network INTERBUS,
widely used in Europe.
S-LINK gateway controller for connection to fieldbus network CC-Link, pro-
moted by Mitsubishi Electric Corp.
S-LINK gateway controller for connection to open network JPCN-1, widely
used in Japan. It incorporates S-LINK system control functions and slave
functions conforming to JPCN-1 or RS-485 so that it can connect an S-LINK
system to a JPCN-1 or RS-485 communication system.
It can be installed in the extension slot (ISA bus) of a PC/AT or compatible so that the personal
computer can be used as a JPCN-1 master.
It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the
S-LINK system and the JPCN-1 mode which enables control of JPCN-1 conforming devices.
It can be installed in the extension slot (C bus) of an NEC PC/FC-98 series so that the personal
computer can be used as a JPCN-1 master.
It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the
S-LINK system and the JPCN-1 mode which enables control of JPCN-1 conforming devices.
It can be installed in the personal computer or board computer of a PC/104 bus so that the per-
sonal computer or board computer can be used as a JPCN-1 master.
It incorporates the S-LINK mode (for RS-485 communication) which enables easy control of the
S-LINK system and the JPCN-1 mode which enables control of JPCN-1 conforming devices.
1 channel I/O unit
2 channel I/O unit
2 channel input unit
2 channel output unit
8 channel snap-
connector input
unit
8 channel snap-
connector out-
put unit
16 channel MIL
connector input
unit
16 channel MIL
connector out-
put unit
Connector I/O unit
SL-CH1
SL-CH1-PN
SL-CH21
SL-CH21-PN
SL-CH21K
SL-CH20
SL-CH20-PN
SL-CH22
SL-CH22-PN
SL-T8J
SL-T8J-PN
SL-TP8J
SL-TP8J-PN
SL-T16C1
SL-T16C1-PN
SL-TP16C1
SL-TP16C1-PN
NPN type
PNP type
NPN type
PNP type
Photocoupler
isolation
(NPN) type
NPN type
PNP type
NPN type
PNP type
NPN type
PNP type
NPN type
PNP type
NPN type
PNP type
NPN type
PNP type
It can be used as either an input unit or an output unit by
switch selection. Hence, a sensor, limit switch, etc., is con-
nectable when it is used as an input, and a relay, lamp,
etc., is connectable when it is used as an output.
1 input and 1 output device are connectable.
It is suitable for power supply remote control func-
tion of NEC FA personal computer FC-98/FC98-NX
series.
2 input devices are connectable.
2 output devices are connectable.
8 input or 8 output devices are connectable with snap
male connectors.
The output unit is incorporated with an output signal hold
function, which retains the output state just prior to an
error on the signal transmission line.
Since connection can be made with an MIL connector, 16
input or 16 output devices can be connected to this slim
I/O unit.
The output unit is incorporated with an output signal hold
function, which retains the output state just prior to an
error on the signal transmission line.
Designation Appearance (Note) Model No. Description
Designation Appearance (Note) Model No. Description
Note: Components with ‘ ’ mark conform to the CE marking EMC Directive.
Note: Components with ‘ ’ mark conform to the CE marking EMC Directive.
(Excluding SL-CH21K)
4 NPN inputs
4 PNP inputs
8 NPN inputs
8 PNP inputs
4 NPN outputs
4 PNP outputs
SL-TW4
SL-TW4-PN
SL-TW8
SL-TW8-PN
SL-TW2P2
SL-TW2P2-PN
SL-TWP4
SL-TWP4-PN
2 NPN inputs and
2 NPN outputs
2 PNP inputs and
2 PNP outputs
SL-TB4
SL-TB4-PN
SL-TB8
SL-TB8-PN
SL-TB16
SL-TB16-PN
SL-TBP4
SL-TBP4-PN
SL-TBP8
SL-TBP8-PN
SL-TBP16
SL-TBP16-PN
SL-TBP4-TY
SL-TBP8-TY
SL-TBP16-TY
4 NPN inputs
4 PNP inputs
8 NPN inputs
8 PNP inputs
16 NPN inputs
16 PNP inputs
4 NPN outputs
4 PNP outputs
8 NPN outputs
8 PNP outputs
16 NPN outputs
16 PNP outputs
4 NPN oututs
8 NPN outputs
16 NPN outputs
They are screw-on terminal units to which 4, 8 or 16 input
devices are connectable. Since power supply terminals
have been provided for each input channel, neat wiring is
possible.
They are screw-on terminal units to which 4, 8 or 16
output devices are connectable. The output unit is
incorporated with an output signal hold function, which
retains the output state just prior to an error on the signal
transmission line.
47
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
ORDER GUIDE
S-LINK I/O devices
I/O arrayed terminal unit
Analog I/O arrayed terminal unit
Environment resistant I/O unit
Designation Appearance (Note) Model No. Description
Output terminal
Input terminal
Output terminal
Input unit
I/O unit
Output unit
They enable forced turning OFF of the output
device connected to the output terminal without
halting the complete S-LINK system, by
switching off the load power supply.
This is an analog input terminal unit which can connect
4 devices having an analog output.
This is an analog output terminal unit which can connect
one device requiring an analog input. It is incorporated
with an output signal hold function, which retains the
output state just prior to an error on the signal
transmission line.
These are units which can connect 4 or 8 input devices.
They feature IP67 (IEC 60529) protection, which can
withstand water splashes. The input devices can be easily
connected by using optional composite connectors.
These are units which can connect 2 inputs and 2 outputs.
They feature IP67 (IEC 60529) protection, which can
withstand water splashes.
They are incorporated with an output signal hold function,
which retains the output state just prior to an error on the
signal transmission line.
These can connect 4 output devices.
They feature IP67 (IEC 60529) protection, which can
withstand water splashes.
They are incorporated with an output signal hold function,
which retains the output state just prior to an error on the
signal transmission line.
SL-TBAD4 4 inputs
1 output
SL-TBDA1
Input terminal
Separate
load power
supply type
Note: Components with ‘ ’ mark conform to the CE marking EMC Directive.
Sensor
main block
They are terminal units to which 4 or 8 output devices can
be connected by slim socket relays that can be easily
replaced. They are incorporated with an output signal hold
function which retains the output state just prior to an error
on the signal transmission line.
4 outputs
(Note 2)
8 outputs
(Note 2)
Plug-in unit
Auto-setting
fiber sensor
Manual setting
fiber sensor
Amplifier-
separated
photoelectric
sensor
Amplifier-
separated
inductive
proximity
sensor
One-touch
clamping type
Screw
tightening
type
Input terminal
unit
Designation Appearance (Note1) Model No. Description
Its thickness is merely 10mm. The incident light intensity
and the threshold value can be seen at a glance from the
backlit LCD. Further, threshold value setting is simple by
using the industry’s first jog switch.
(For details, refer to P.64lfor the FX-D1 series.)
Its thickness is merely 10mm. The sensitivity setting is
simple by using the industry’s first jog switch. Level
indicators, comprising of 10 LEDs, which enable
confirmation of the set sensitivity at a glance, have been
incorporated.
(For details, refer to P.64lfor the FX-A1 series.)
Its thickness is merely 10mm. Since the sensitivity setting
is done by a 12-turn potentiometer, fine setting is possible.
(For details, refer to P.64lfor the FX-M1 series.)
Red LED
Red LED
Green LED
Red LED
Green LED
FX-A1J
FX-A1GJ
FX-M1J
FX-M1GJ
FX-D1J
SL-TJ1
SU-7J
GA-14J
GA-15J
Its thickness is merely 10mm. The sensitivity is automatically set with ease.
12 kinds of sensor heads are suitable with it.
(For details, refer to P.350lfor the SU-7 series.)
Its thickness is merely 10mm. The sensitivity is so precisely set with the 18-
turn adjuster that the sensor is suitable for sophisticated applications with a
high repeatability of 1!m or less.
(For details, refer to P.686lfor the GA-10 series.)
It allows connection of 1 No. of various kinds of input devices, such as, a
photoelectric sensor, an inductive proximity sensor or a limit switch.
SL-TPR4
SL-TPR8
SL-BMJ
SL-BXJ
SL-BM
SL-BX
It allows connection of various kinds of input devices, such as, photoelectric
sensors, inductive proximity sensors, limit switches, and push buttons with
the snap female connectors. One SL-BMJ can be extended by one SL-BXJ
or two SL-BXs, up to 16 input points.
It can generate the ORed self-diagnosis output of all the connected
devices. In this case, the first channel gets occupied.
Sensor
main block
4 relay output
8 relay output
Extension
block
Snap-connector
For plug-in unit
Sensor block Relay output
terminal unit
It can follow either main block, and allows connection of 8 input devices.
It allows connection of various kinds of plug-in units of fiber sensors,
amplifier-separated photoelectric sensors, amplifier-separated inductive
proximity sensors and input terminal units. One SL-BM can be extended by
three SL-BXs or one SL-BX plus one SL-BXJ, up to 16 input points.
It can generate the ORed self-diagnosis output of all connected units. In
this case the first channel gets occupied.
It can follow either main block, and allows connection of four plug-in units.
( )
( )
S-LINK
48
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
ORDER GUIDE
S-LINK I/O devices
Notes: 1) Components with ‘ ’ mark conform to the CE marking EMC Directive.
Notes: 2) Relay output is
Contact a’ only. Further, when replacing the relay, use PA relay (APA 3312) made by Matsushita Electric Works.
Notes: 3) Output 2 cannot be used when connection is made to the plug-in unit sensor block.
Extension
block
Digital setting
fiber sensor
(Note 3)
49
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
ORDER GUIDE
S-LINK I/O devices
8 inputs
16 inputs
4 inputs and
4 outputs
These are IC type modules which enable external
connection of address setting switches and operation
indicators. They increase the design flexibility.
8 outputs
16 outputs
4 inputs and
4 outputs
8 inputs
16 inputs
8 outputs
16 outputs
SL-M8
SL-M16
SL-MP8F
SL-MP16F
SL-M4P4F
SL-MP8
SL-MP16
SL-M8F
SL-M16F
SL-M4P4
Input
module
I/O mixed
module
Output
module
Input
module
I/O mixed
module
Output
module
I/O module
Vertical typeHorizontal type
Designation Appearance Model No. Description
S-LINK direct hook-
up photoelectric
sensor
Thru-beam type 10m
Thru-beam type 30m
Retroreflective type with
polarizing filters 0.1 to 5m
Diffuse reflective type
700mm
These can be hooked up to the S-LINK cable, at
any place, without any interface.
Sensing range: 0.2 to 3m
0.05 to 1m when the
switch is set to SHORT
Beam pitch: 25mm
Sensing height: 100mm
Sensing object:
"35mm or more
opaque object
It is a parts-taking verification sensor with five
sensing beams and can be hooked up to the
S-LINK cable without any interface.
Both the emitter and the receiver are incor-
porated with bright orange LED job indicators
that are easily visible to the operator.
SL-A11
SL-A13
SL-A19
SL-A12
SL-N15
S-LINK direct hook-
up area sensor
Retroreflective type with
polarizing filters
Thru-beam type
Diffuse reflective type
()
SL-CJ12 (White)
(1 set: 10 Nos.)
SL-JK1
(Blue)
(1 set: 10 Nos.)
Designation Appearance Model No. Description
Hook-up connector
Cable extension
hook-up connector
End hook-up
connector
Cable attached end
connector
Cable end socket-
branch hook-up
connector
Socket-branch hook-
up connector
4-pin type snap
female connector
2-pin type snap
female connector
2-pin type snap
male connector
SL-J1A
(Gray)
(1 set: 10 Nos.)
SL-J3A
(Black)
(1 set: 10 Nos.)
SL-JE
(Gray)
(1 set: 5 Nos.)
SL-JE-RC
(Gray)
(1 set: 1 No.)
SL-JK
(Light blue)
(1 set: 10 Nos.)
SL-CJ1 (White)
(1 set: 10 Nos.)
SL-CJ2 (Black)
(1 set: 10 Nos.)
SL-CP1 (White)
(1 set: 10 Nos.)
SL-CP2 (Black)
(1 set: 10 Nos.)
SL-CP12 (White)
(1 set: 10 Nos.)
SL-CP22 (Black)
(1 set: 10 Nos.)
It creates a ‘T’-branch connection between two S-LINK exclusive flat cables.
For 0.5mm2flat cable to 0.5mm2flat cable connection
It can extend the S-LINK exclusive flat cable.
For 0.5mm2flat cable to 0.5mm2flat cable connection
It must be connected at the end of the main cable.
For 0.5mm2flat cable
When cabtyre cable is used as the main cable, the end connector can be
easily connected.
It enables one I/O device to be connected at the S-LINK exclusive flat cable
end with the snap male connector SL-CP1, SL-CP2 or SL-CP3.
For 0.5mm2flat cable
It enables one I/O device to be branched off in the middle of the S-LINK
exclusive flat cable with the snap male connector SL-CP1, SL-CP2 or SL-CP3.
For 0.5mm2flat cable
It can be plugged into the socket of SL-BMJ or SL-BXJ to
connect an input device, or into the snap male connector
SL-CP1, SL-CP2 or SL-CP3 to extend the cable length.
It can be used for cable extension of 2-wire I/O devices by
combining with a snap male connector SL-CP12 or
SL-CP22.
It can used for cable extension of 2-wire I/O devices by
combining with a snap female connector SL-CJ12 or
SL-CJ22.
For 0.08 to 0.2mm
2
Wire dia.: "0.7 to "1.2mm
For 0.3mm
2
Wire dia.: "1.1 to "1.6mm
For 0.08 to 0.2mm
2
Wire dia:
"
0.7 to
"
1.2mm
For 0.3mm
2
Wire dia:
"
1.1 to
"
1.6mm
For 0.5mm
2
Wire dia.:
"
1.7 to
"
2.5mm
4-pin type snap
male connector
1234
It can be plugged into the socket of SL-T8J or SL-TP8J to
connect an I/O device, or into the socket-branch hook-up
connector SL-JK or SL-JK1 to connect an S-LINK direct
hook-up sensor.
Using SL-CP3, S-LINK I/O devices (with 0.5mm2cable)
can be easily connected/ disconnected from the
main/branch cable.
For 0.08 to 0.2 mm
2
Wire dia.: "0.7 to "1.2mm
For 0.3mm
2
Wire dia.: "1.1 to "1.6mm
SL-CJ22 (Black)
(1 set: 10 Nos.)
SL-CP3
(Greenish blue)
(1 set : 10 Nos.)
S-LINK
50
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
ORDER GUIDE
Connectors
1234
For 0.08 to 0.2mm
2
Wire dia.:
"
0.7 to
"
1.2mm
For 0.3mm
2
Wire dia.:
"
1.1 to
"
1.6mm
NOTE
The connectors are supplied in sets of 10 Nos. (SL-JE: 5 Nos., SL-JE-RC: 1 No.)
Please order in units of 10 Nos. (SL-JE: 5 Nos., SL-JE-RC: 1 No.)
(e.g.) In case 30 Nos. of SL-J1A are required, order SL-J1A3 (sets).
For 0.18 to 0.75mm
2
Wire dia.: "3 to "4mm
For 0.18 to 0.75mm
2
Wire dia.: "4 to "5mm
For 0.18 to 0.75mm
2
Wire dia.: "5 to "6mm
For 0.3 to 0.75mm
2
Wire dia.: "6 to "8mm
For 0.3 to 0.75mm
2
Wire dia.: "6 to "8mm
This is a connector for branching of the main/branch cable and for connection
of the thru-beam type photoelectric sensor to the environment resistant I/O
unit SL-TW.
It is connected when the environment resistant I/O unit SL-TWis used at
the end of the main cable.
These are composite male connectors for connection of
input or output devices to the environment resistant I/O unit
SL-TW, and for connection to the branch connector
SL-WY or the composite female connector SL-WJ8.
These are composite female connectors for connection to
the main cable side of the environment resistant I/O unit
SL-TW, and for connection to the branch connector
SL-WY or the composite male connector SL-WP.
Designation Appearance Model No. Description
Water resistant connector
Composite
male connector
Composite
female connector
Branch
connector
Environment
resistant end
connector
SL-WP4
(1 set: 10 Nos.)
SL-WP5
(1 set: 10 Nos.)
SL-WP6
(1 set: 10 Nos.)
SL-WP8
(1 set: 10 Nos.)
SL-WJ8
(1 set: 10 Nos.)
SL-WY
(1 set: 5 Nos.)
SL-WE
(1 set: 1 No.)
51
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
ORDER GUIDE
Connectors
NOTE
The connectors are supplied in sets of 10 Nos. (SL-WY: 5 Nos., SL-WE: 1 No.)
Please order in units of 10 Nos. (SL-WY: 5 Nos., SL-WE: 1 No.)
(e.g.) In case 30 Nos. of SL-WP4 are required, order SL-WP43 (sets)
Optional units
Designation Appearance (Note) Model No. Description
Booster
Handy monitor
Note: Components with ‘ ’ mark conform to the CE marking EMC Directive.
SL-BS1A
SL-HM1
It can extend the signal transmission distance by 200m.
A maximum of seven boosters can be connected for one S-LINK control unit.
However, one booster can never be followed by another booster in series.
It can be connected at any place on the signal transmission line and the I/O
states can be checked in batches of 16.
The handy monitor is also incorporated with the S-LINK control functions, so
that, for example, it can perform an I/O check on conveyor system
segments, still under assembly, even without the S-LINK controller.
MS-SLH
(1 set: 5 Nos.)
SL-MA2
(1 set: 20 Nos.)
SL-WJK
(1 set: 10 Nos.)
SL-WPK
(1 set: 10 Nos.)
S-LINK
52
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
Others
Designation Appearance Model No. Description
S-LINK exclusive
flat cable
S-LINK exclusive
cabtyre cable
S-LINK exclusive
pliers
S-LINK exclusive
ratchet pliers
SL-CP3 exclusive
pliers
SL-CJ1/2/12/22 and
SL-CP1/2/12/22
exclusive pliers
Cover for M12
male connector
Cover for M12
female connector
Marking plate
Address label
Length: 100m
Length: 200m
S-LINK exclusive flat cable (4-core)
Conductor cross-section area: 0.5mm2
Outer diameter: "2.5mm4
SL-RCM100
SL-RCM100-PK
SL-RCM100-GN
SL-RCM100-GY
SL-RCM200
SL-CBM100
SL-CBM200
Length: 100m
Length: 200m
D line: White
D line: White
with pink stripe
D line: White
with green stripe
D line: White
with gray stripe
S-LINK exclusive cabtyre cable (4-core)
Conductor cross-section area: 0.5mm2
Outer diameter: "7.4mm
SL-JPS
SL-JPD
SL-JPE
SL-JPC
Hook-up connector (SL-J) can be connected in one grip.
Because of the ratchet mechanism, hook-up connector (SL-J) can be
simply connected in one grip.
Snap male connector (SL-CP3) can be connected in one grip.
Hook-up connector (SL-CJ1/2/12/22, SL-CP1/2/12/22) can be connected in
one grip.
Make sure to put it on the unused main cable side connectors of the
environment resistant I/O unit SL-TW.
Make sure to put it on the unused I/O side connectors of the environment
resistant I/O unit SL-TW.
It is used to write the I/O device No., address No., etc., on the environment
resistant I/O unit SL-TW.
It is used to mount the SL-CHunit.
By sticking the labels on the respective S-LINK devices, the set addresses
can be confirmed at one glance.
SL-MA1-SET is available in white, pink, green and gray colors, as a 4-sheet
set, and is convenient when used by matching the color with that of the
S-LINK exclusive flat cable (100m type).
I/O unit holder for
SL-CH
NOTE
The connectors are supplied in sets of 10 Nos., the marking plate in sets of 20 Nos., the I/O unit holder
for SL-CHin sets of 5 Nos. and t
he address seal in sets of 4 sheets.
Please order in units of 10 Nos., 20 Nos., 5 Nos. or 4 sheets, respectively.
(e.g.) In case 10 Nos. of MS-SLH are required, order MS-SLH2 (sets).
In case 8 sheets of SL-MA1-SET are required, order SL-MA1-SET2 (sets).
SL-MA1-SET
(1 set: 4 sheets)
ORDER GUIDE
NOTE
The slit mask for SL-N15 is supplied in sets of 10 sheets.
Please order in units of 10 sheets.
(e.g.) In case 20 sheets of OS-NA1-5 are required, order
OS-NA1-52 (sets).
53
S-LINK
WIRE-SAVING SYSTEMS
SL-BMW/BW
Simple Wiring
S-LINK
‘T’-branch Multi-drop
OPTION
Designation Model No. Description
Sensor mounting
bracket for SL-A
Sensor mounting
bracket for SL-N15
Sensor protec-
tion bracket for
SL-N15
Reflector mount-
ing bracket
Slit mask for
SL-N15
Connector I/O unit
mounting bracket
MS-NX5-1
MS-NX5-2
MS-NX5-3
MS-NA1-1
MS-NA2-1
MS-NA3
MS-RF23
OS-NA1-5
(1 set: 10 sheets)
MS-DIN-3
Foot angled mounting bracket
(The thru-beam type sensor needs two brackets.)
Foot biangled mounting bracket (sensor protection bracket)
(The thru-beam type sensor needs two brackets.)
Back angled mounting bracket
(The thru-beam type sensor needs two brackets.)
Four bracket set
Four M4 (length 15mm) screws with
washers, eight nuts, four hooks, four
spacers and eight M4 (length
18mm) screws with washers are
attached.
(Spacers are not attached with MS-NA1-1.)
It protects the sensor body.
Two bracket set
Four M4 (length 15mm) screws with
washers, and four nuts are attached.
For RF-230
The seal type slit mask restrains the
amount of beam emitted or received.
It is a DIN rail mounting bracket which
can be fitted on the mounting base of
SL-T8J(-PN), SL-TP8J(-PN), SL-T16C1(-PN)
and SL-TP16C1(-PN).
MS-NA1
M4 screws with washers, nuts
and hooks are attached.
M4 screws with washers, nuts,
hooks and spacers are attached.
MS-NA2
M4 screws with washers and, nuts are attached.
Two M4 (length 10mm)
screws with washers
are attached.
Sensor protection bracket
for SL-N15 Reflector mounting bracket
Slit mask for SL-N15 Connector I/O unit
mounting bracket
Sensor mounting bracket for SL-N15
MS-NA1-1 MS-NA2-1
Sensor mounting bracket for SL-A
MS-NX5-1 MS-NX5-2 MS-NX5-3
Since the slit mask is seal
type, it can be used by stick-
ing it to the detection surface.
Take care that the sensing
range will be reduced when
the slit mask is used.
Please contact our office for
details.
Two M4 (length 25mm)
screws with washers
and two M4 nuts are
attached.
Two M4 (length 25mm)
screws with washers
and two M4 nuts are
attached.
Two M4 (length 25mm)
screws with washers
and two M4 nuts are
attached.
Please refer to the S-LINK Design Manual for the specifications and dimensions of the S-LINK
devices.