Keysight Technologies
E4980AL Precision LCR Meter
20 Hz to 300 kHz/500 kHz/1 MHz
Providing the best combination of accuracy, speed and versatility
02 | Keysight | E4980AL Precision LCR Metert - Brochure
Keysight’s E4980AL precision LCR
meter provides the best combination
of accuracy, speed, and versatility for a
wide range of component measurements.
Offering fast measurement speed and
outstanding performance at both low and
high impedance ranges, the E4980AL
is the basic tool for general R&D and
manufacturing test of components and
materials.
Fast measurement speed
The E4980AL offers excellent speed:
12 ms (SHORT)1
118 ms (MED)1
343 ms (LONG)1
Accurate measurements
Exceptionally low noise at both low
and high impedance for evaluating the
characteristics of inductors and capacitors
with excellent accuracy and repeatability.
0.05% basic impedance accuracy
1/2/4m cable extension capability
Open/Short/Load correction
DC bias
Built-in DC-voltage-bias source provides
accurate bias dependency evaluation for
C, L, and material measurements.
1.5 V and 2 V
1. Measurement time at 1 MHz. Supplemental information. For additional details, refer to the E4980A/
E4980AL data sheet (literature number 5989-4435EN).
High-resolution LCD display
Full, 7-digit display and 6
display modes for clear and
easy viewing.
LED status lights
Conveniently view
DC bias and USB
memory status.
Simple and intuitive operation
Easily congure measurements
with soft keys (same interface
as Keysight’s 4284A LCR meter),
one-touch front panel keys and
an intuitive user interface.
USB interface
(memory devices only)
Easily save measurement
states, data logs, and
screen captures to USB
memory devices.
100 µV to 2 Vrms variable test signals
Provides signal levels to evaluate the
AC voltage characteristics of your
devices.
A Standard LCR Meter
03 | Keysight | E4980AL Precision LCR Metert - Brochure
1. Measurement time at 1 MHz. Supplemental information. For additional details, refer to
the E4980A/E4980AL data sheet (literature number 5989-4435EN).
Compact and light weight
Small size for easy transportation
370 (W) x 105 (H) x 390 (D) mm
5.3 kg (11.7 lb.)
Standard LAN/USB/GPIB interface
Flexible PC connectivity and fast transfer speed
10/100 Base-T LAN
USB (USBTMC) interface
GPIB for robust instrument control and test
automation External trigger
Key Features
Accurate measurements
Exceptionally low noise at both low and
high impedance to improve test quality.
0.05 % basic impedance accuracy
Open /Shor t /L oad compens ation
support
Cable extension (1/2/4m) support
Fast measurement speed1
Fast speed provides more throughput
reducing cost of test.
12 ms (SHORT)
118 ms (MED)
343 ms (LONG)
Measurement versatility
20 Hz to 300 kHz/500 kHz/1 MHz
test frequency with 4-digit resolution
at any frequency
16 impedance parameters
100 µV to 2 Vrms, 1 µA to 20 mA
variable test signal
Auto-level control
201 points of programmable list
sweep
DC resistance
04 | Keysight | E4980AL Precision LCR Metert - Brochure
Broad range impedance
measurements
The E4980AL LCR meter offers
excellent performance for all impedance
measurements.
Reliable measurement performance is
needed to meet the test requirements of
today’s latest devices. The E4980AL offers
fast measurement speed and outstanding
performance within “both” low and high
impedance ranges with exceptional
dissipation factor accuracy.
Stable small ESR/low
impedance measurements
The equivalent series resistance (ESR)
of capacitors is becoming smaller and
smaller to meet high-speed and low
power-consumption circuit needs; and is
difcult to measure. The E4980AL provides
exceptional measurement stability.
Exceptionally accurate, high
impedance measurements
The capacitance values of chip-capacitors
are now down to femto-farad (fF) range.
Thus, very stable and accurate high
impedance measurements are required
for higher yields and design reliability.
Surpassing Agilent’s previous industry-
standard LCR meter (4284A), the E4980AL
further improves measurement stability for
these small capacitance devices.
1. Measurement time at 1 MHz. Supplemental information. For additional details, refer to the E4980A/
E4980AL data sheet (literature number 5989-4435EN).
2. Applied up to 300 kHz/500 kHz/1 MHz for E4980AL.
Accurate, Fast Measurements up to 300 kHz/500 kHz/1 MHz
Accurate measurements provide design and test condence
Figure 1. 10% impedance measurement accuracy range. Test signal 1 Vrms,
MED mode, cable 0m2
Offering the industrys best
combination of speed and
accuracy
Fast measurement speed
for more throughput in
manufacturing
12 ms per point at 1 MHz with
SHORT mode1
118 ms per point at 1 MHz with
MED mode1
343 ms per point at 1 MHz with
LONG mode1
Average function (up to 256)
Enables users to improve
measurement repeatability.
05 | Keysight | E4980AL Precision LCR Metert - Brochure
Versatile Measurement Capability to Meet your Application Needs
Powerful features increase test reliability and efciency
Figure 2. Select one of six display modes
Figure 3. List sweep mode
Figure 4. DCR measurement
Six convenient display modes
Select one of six display modes to suit your
particular measurement needs.
Normal view for a data overview
Large display view for enhanced read-
ability
BIN No. view for measurement com-
parison and device sorting
BIN count view for statistical evalua-
tion
LIST sweep view for continuous data
Blank page view for ultimate speed
(Turns off display to save refresh
time.)
201 points list sweep
Frequency, measurement range, and
stimulus conditions, can be set as list
parameters (max 201 points). You can
choose two parameters independently
to test under a variety of measurement
conditions.
DC resistance measurement
For inductor measurements, Ls or Lp and
Rdc parameters can be measured at the
same time.
06 | Keysight | E4980AL Precision LCR Metert - Brochure
Support for a wide variety of test
xtures
The E4980AL can be used with over
twenty xtures to meet a variety of
evaluation needs; from materials to SMD
components. Also, built-in compensation
functions minimize the inuence of test
xtures.
USB memory support
The front panel USB memory interface
allows you to quickly and easily save state
les, measurement log data, and display
images to an external USB memory device
(mass storage).
PC connectivity
Standard GPIB/LAN/USB control
interfaces provide a variety of paths for
controlling the instrument. Using a LAN
cable, you can even control the E4980AL
with a computer and Web browser.
Upgradability
Following upgrade options are available.
E4980ALU-052: 300 kHz to 500 kHz
E4980ALU-112: 300 kHz to 1 MHz
E4980ALU-113: 500 kHz to 1 MHz
Refer to the conguration guide for more
details.
Figure 5. The E4980AL LCR meter offers support for a wide variety
of test xtures
Figure 7. The E4980AL LCR meter can conveniently be controlled over LAN with a
computer and a Web browser
Figure 6. Example of use with USB storage device
Exceeding Expectations in Productivity
07 | Keysight | E4980AL Precision LCR Metert - Brochure
Quick Product Comparison
4263B LCR meter (Discontinued) E4980AL Precision LCR meter E4980A Precision LCR meter
Frequency 100, 120, 1 k, 10 k, 20 k, and 100 kHz 20 Hz to 300 k/500 k/1 MHz 20 Hz to 2 MHz
Test signal level 20 m to 1 Vrms 0 to 2 Vrms/0 to 20 mArms 0 to 2 Vrms or 20 Vrms (Option 001) /0 to 20
mArms or 100 mArms (Option 001)
Auto level control (ALC) No Yes Yes
DC bias capability 1.5 V, 2 V Built-in 1.5 V, 2 V 1.5 V, 2 V or ± 40 V (Opt. 001)
Programmable list sweep No 201 points 201 points
Remote control GPIB GPIB, LAN, USB GPIB, LAN, USB
Web browser control No Yes Yes
Interface option Handler None Handler (Option 201) / Scanner (Option 301)
Parameters Impedance, DCR, N, M Impedance, DCR Impedance, DCR (Option 200)
Control commands 4263B unique E4980A/4284A compatible E4980A/4284A compatible
Basic accuracy 0.1% @ Medium 0.1% @ Short
0.05% @ MED/LONG
0.1% @ Short
0.05% @ MED/LONG
Measurement time mode 25 ms Short mode, 65 ms Medium mode 149 ms @ 100 Hz
26 ms @ 1 kHz
12 ms @ 1MHz
Short mode
100 ms @ 100 Hz
20 ms @ 1 kHz
5.6 ms @1 MHz
Short mode
Storage devices Internal Internal/USB memory Internal/USB memory
Cable length 0, 1, 2, 4 m 0, 1, 2, 4 m 0, 1, 2, 4 m
Cabinet dimensions (mm) 320 (W) x 100 (H) x 300 (D) 370 (W) x 105 (H) x 390 (D) 370 (W) x 105 (H) x 390 (D)
Weight 4.5 kg 5.3 kg 5.3 kg
Ordering Information
E4980AL Precision LCR Meter, 20 Hz to 300 kHz/500 kHz/1 MHz
Options
Model Description
E4980AL-032 20 Hz to 300 kHz with DCR Measurement
E4980AL-052 20 Hz to 500 kHz with DCR Measurement
E4980AL-102 20 Hz to 1 MHz with DCR Measurement
For more details on the option conguration, refer to the E4980A/E4980AL conguration
guide (literature number 5989-8321EN).
Upgrade options
Model Description
E4980ALU-052 Upgrade from 300 kHz to 500 kHz for E4980AL-032
E4980ALU-112 Upgrade from 300 kHz to 1 MHz for E4980AL-032
E4980ALU-113 Upgrade from 500 kHz to 1 MHz for E4980AL-052
08 | Keysight | E4980AL Precision LCR Metert - Brochure
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
Insert registered trademarkss and copyright notes here. If none, remove row from table.
www.keysight.com/find/e4980al
This information is subject to change without notice.
© Keysight Technologies, 2013 - 2014
Published in USA, December 2, 2014
5991-2305EN
www.keysight.com
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444
Asia Pacic
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-09-23-14)
Web Resources
Visit our E4980AL Web site for additional product information and literature.
www.keysight.com/find/E4980AL
LCR Meters & Impedance Measurement Products
www.keysight.com/find/impedance
GSA Approved Products
For customers who must comply with the U.S. General Services Administration, the following
products are offered as part of our GSA contract and can be found on www.GSAadvantage.com.
These products can be seen on our website with a GSA suffix.
Contact Information:
www.Farnell.co.uk
www.Newark.com