FEATURES
Laser-based light scattering particle sensing
Concentration range: 0 µg/m3 to 1,000 µg/m3
Fully calibrated
EMC: Heavy industrial level IEC61000
Response time: <6 s
Supply current: 80 mA max.
Output signal: UART (Universal Asynchronous Receiver/
Transmitter)
PM2.5, PM10 output (standard); PM1.0, PM2.5, PM4.0,
PM10 output (compact)
RoHS compliant
REACH compliant
DIFFERENTIATION
Long life of 10 years offers a more stable operation for
continuous usage
Proven EMC performance, based on IEC61000 stable
operation, ±15% accuracy (PM2.5)
POTENTIAL APPLICATIONS
HVAC (commercial and residential)
Indoor air quality monitors
Handheld air quality monitors
Air purifiers (commercial and residential)
Automotive cabin air purifiers
Sensing and Internet of Things
DESCRIPTION
The Honeywell HPM Series Particulate Matter Sensor is a
laser-based sensor which detects and counts particles using
light scattering. The detection concentration range is
0 µg/m3 to 1,000 µg/m3. A laser light source illuminates a
particle as it is pulled through the detection chamber. As
particles pass through the laser beam, the light reects off
the particles and is recorded on the photo or light detector.
The light is then analyzed and converted to an electrical
signal to calculate particle concentration. The Honeywell
particle sensor provides information on the particle
concentration for given particle concentration range.
VALUE TO CUSTOMERS
Enables the ability to more accurately and cost-
competitively monitor or control environmental particulate
Industry-leading long life of 10 years of continuous use
Proven EMC performance enables the ability to
perform more accurately in a variety of tough industrial
environments
Faster response time of <6 s allows the HPM Series to
respond to environmental conditions in real time
Enhanced reliability allows for use in harsh environments
HPM Series
Particulate Matter Sensors
32322550
Issue F
Standard Compact
Datasheet
2sensing.honeywell.com
Particulate Matter Sensors
HPM Series
Table 1. Specifications
Characteristic
Standard Compact
Operating principle laser scattering
Detection1,2 PM2.5, PM10 PM1.0, PM2.5, PM4.0, PM10
Output data1, 2 PM2.5 in µg/m3, PM10 in µg/m3PM1.0 in µg/m3, PM2.5 in µg/m3,
PM4.0 in µg/m3, PM10 in µg/m3
Concentration range 0 µg/m3 to 1,000 µg/m3
Accuracy (at 25°C ±5°C):
0 µg/m3 to 100 µg/m3
100 µg/m3 to 1000 µg/m3
PM2.5: ±15 µg/m3
PM2.5: ±15 %
PM2.5: ±15 µg/m3; PM1.0, PM4.0, PM10: ±25 µg/m3
PM2.5: ±15 %; PM1.0, PM4.0, PM10: ±25%;
Response time <6 s
Supply voltage35 V ±0.2 V
Switching frequency max. 100 kHz
Ripple amplitude max. 20 mV
R.M.S noise max. 1 mV (noise bandwidth 10 MHz)
Standby current (at 25°C ±5°C) <20 mA
Supply current (at 25°C ±5°C) <80 mA
Inrush current max. (at 25°C ±5°C) 600 mA
Temperature:
operating
storage
-20°C to 50°C [-F to 12F]
-30°C to 6C [-2F to 149°F]
-20°C to 70°C [-F to 158°F]
-40°C to 8C [-40°F to 185°F]
Humidity (operating and storage) 0 %RH to 95 %RH non-condensing
Output protocol4UART; baud rate: 9600, databits: 8, stopbits: 1, parity: no
Operating time:
continuous mode
intermittent mode
10 years
depends on duty cycle
Laser class Laser Class 1: IEC/EN 60825-1: 650 nm
ESD ±4 kV contact, ±8 kV air per IEC 61000-4-2
Radiated immunity 1 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3
Fast transient burst ±0.5 kV per IEC61000-4-4
Immunity to conducted disturbances
radiated emissions 3 V per IEC61000-4-6
Radiated emissions 40 dB 30 MHz to 230 MHz; 47 dB 230 MHz to 1000 MHz per CISPR 14
Conducted emissions 0.15 MHz to 30 MHz in compliance with CISPR 14
Dimensions (L X W X H) 43 mm x 36,00 mm x 23,7 mm
[1.69 in x 1.42 in x 0.93 in]
44 mm x 36 mm x 12 mm
[1.73 in x 1.42 in x 0.48 in]
1 PM2.5 is particulate matter <2.5 µm in diameter; PM10 is particulate matter <10 µm in diameter.
2 PM1.0 in µg/m3, PM4.0 in µg/m3, and PM10 in µg/m3 are calculated from PM 2.5 readings.
3 Power supply output should contain one de-coupling capacitor (22 µF), and two ceramic
capacitors (100 nF, 10 nF), if ripple amplitude max. or R.M.S. noise max. exceeds specifications.
4 Contact Honeywell for other output options.
Table 2. Order Guide
Catalog Listing Description
HPMA115S0-XXX HPM Series PM2.5 Particulate Matter Sensor, standard size, UART output
HPMA115C0-003 HPM Series PM2.5 Particulate Matter Sensor, compact size, UART output, air inlet and air outlet on same side
HPMA115C0-004 HPM Series PM2.5 Particulate Matter Sensor, compact size, UART output, air inlet and air outlet on opposite sides
CLASS 1
LASER PRODUCT
HPMA115S0-XXX
HPMA115C0-003
HPMA115C0-004
3
Sensing and Internet of Things
Particulate Matter Sensors
HPM Series
Figure 1. HPM Series Operation (standard version shown top down)
Signal
to MCU
Particle
Fan
Lens Laser
source Laser
drive
circuit
Air inlet
Light
trap
Connector
Photodiode
Photoelectric
converter
Air outlet
1
2
3
4
Fan draws in air through inlet.
Air passes through the laser where the light reflected off the
particles is captured by the photodiode.
The photodiode passes information to the photoelectric converter
The photoelectric converter processes the signal from the particles into density
.
Signal is transmitted to micro control unit where a proprietary
algorithm processes the data and supplies outputs for the density of the
particulate (
g/m
3
).
3
4
1
2
Table 3. Standard and Compact Connector Pinout
Standard Compact
Pin Name Description Pin Name Description
1VOUT power output (+3.3 V/100 mA) 1VOUT
power output (+5 V)
(output max.: 300 mA)
2VCC power input (5 V) 2VCC power input (+5 V)
3N/A N/A 3GND ground
4N/A N/A 4GND ground
5RES reserved for future use 5RES reserved for future use
6TX UART TX output (0 V - 3.3 V) 6N/A N/A
7RX UART RX input (0 V - 3.3 V) 7RX UART RX input (0 V - 3.3 V)
8GND ground 8N/A N/A
- 9TX UART TX output (0 V - 3.3 V)
- 10 SET reserved for future use
9
7
5
3
1
10
8
6
4
2
8 7 6 5 4 3 2 1
4sensing.honeywell.com
Particulate Matter Sensors
HPM Series
Table 4. Standard Version Customer Use Protocol1
Command Length
(Bytes) HEAD LEN CMD Data CS Example
Read Particle Measuring Results
Send 0x68 0x01 0x04 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 04 93
Response, Pos ACK 0x40 0x05 0X04
“DF1, DF2, DF3, DF4
PM2.5 = DF1 * 256 + DF2
PM10 = DF3 * 256 + DF4”
CS = MOD
((65536(HEAD+LEN+CMD+DATA)),
256)
40 05 04 00
30 00 31 56
Response, Neg ACK 0X9696
Start Particle Measurement
Send 0x68 0x01 0x01 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 01 96
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
Stop Particle Measurement2
Send 0x68 0x01 0x02 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 02 95
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
Set Customer Adjustment Coefficient
Send 0x68 0x02 0x08 DF1: 30 ~ 200
(Default, 100)
CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 02 08 64 2A
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
Read Customer Adjustment Coefficient
Send 0x68 0x01 0x10 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 10 87
Response, Pos ACK 0X40 0X02 0X10 DF1: 30 ~ 200
(Default, 100)
CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 40 02 10 64 4A
Response, Neg ACK 0x9696
Stop Auto Send
Send 0x68 0x01 0x20 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 20 77
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
Enable Auto Send3
Send 0x68 0x01 0x40 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 40 57
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
1Product life may vary depending on the specific application in which the sensor is utilized.
2Shuts down the fan, helping to extend the life of the product.
3See Table 6 for data format.
5
Sensing and Internet of Things
Particulate Matter Sensors
HPM Series
Table 5. Standard Version Data Format (Protocol Length: 32 Bytes)
Byte Number Head0 Head0 Head0
Byte0 Head0 0x42
fixed
Byte1 Head1 0x4d
Byte2 Len_H
Frame Length = 2x13+2(data length + checksum length)
Byte3 Len_L
Byte4 Data0_H
reserve
Byte5 Data0_L
Byte6 Data1_H
PM2.5 concentration (standard particulate matter)
By te7 Data1_L
Byte8 Data2_H
PM10 concentration (standard particulate matter)
Byte9 Data2_L
Byte10 Data3_H
reserve
Byte11 Data3_L
Byte12 Data4_H
reserve
Byte13 Data4_L
Byte14 Data5_H
reserve
Byte15 Data5_L
Byte16 Data6_H
reserve
Byte17 Data6_L
Byte18 Data7_H
reserve
Byte19 Data7_L
Byte20 Data8_H
reserve
Byte21 Data8_L
Byte22 Data9_H
reserve
Byte23 Data9_L
Byte24 Data10_H
reserve
Byte25 Data10_L
Byte26 Data11_H
reserve
Byte27 Data11_L
Byte28 Data12_H
reserve
Byte29 Data12_L
Byte30 CheckSum_H
Checksum = Head0+Head1+Len_H+Len_L+Data0_H+…+Data12_L
Byte31 CheckSum_H
6sensing.honeywell.com
Particulate Matter Sensors
HPM Series
Table 6. Compact Version Customer Use Protocol1
Command Length
(Bytes) HEAD LEN CMD Data CS Example
Read Particle Measuring Results
Send 0x68 0x01 0x04 NA
CS = MOD
((65536-(HEAD+LEN+CMD+DATA)),
256)
68 01 04 93
Response, Pos ACK 0x40 0x05 0X04
DF1-DF8, DF9~ DF12 reserved
PM1.0 = DF1 * 256 + DF2
PM2.5 = DF3 * 256 + DF4
PM4.0 = DF5 * 256 + DF6
PM10 = DF7 * 256 + DF8
CS = MOD
((65536(HEAD+LEN+CMD+DATA)), 256)
40 0D 04 00
30 00 31 00 32
00 33 00 00 00
00 E9
Response, Neg ACK 0X9696
Start Particle Measurement
Send 0x68 0x01 0x01 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 01 96
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
Stop Particle Measurement2
Send 0x68 0x01 0x02 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 02 95
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
Set Customer Adjustment Coefficient
Send 0x68 0x02 0x08 DF1: 30 ~ 200
(Default, 100)
CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 02 08 64 2A
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
Read Customer Adjustment Coefficient
Send 0x68 0x01 0x10 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 10 87
Response, Pos ACK 0X40 0X02 0X10 DF1: 30 ~ 200
(Default, 100)
CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 40 02 10 64 4A
Response, Neg ACK 0x9696
Stop Auto Send
Send 0x68 0x01 0x20 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 20 77
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
Enable Auto Send3
Send 0x68 0x01 0x40 NA CS = MOD
((65536-(HEAD+LEN+CMD+DATA)), 256) 68 01 40 57
Response, Pos ACK 0xA5A5
Response, Neg ACK 0x9696
1Product life may vary depending on the specific application in which the sensor is utilized.
2Shuts down the fan, helping to extend the life of the product.
3See Table 7 for data format.
7
Sensing and Internet of Things
Particulate Matter Sensors
HPM Series
Table 7. Compact Version Data Format (Protocol Length: 32 Bytes)
Byte Number Head0 Head0 Head0
Byte0 Head0 0x42
fixed
Byte1 Head1 0x4d
Byte2 Len_H
Frame Length = 2x13+2(data length + checksum length)
Byte3 Len_L
Byte4 Data0_H
PM1.0 concentration (standard particulate matter)
Byte5 Data0_L
Byte6 Data1_H
PM2.5 concentration (standard particulate matter)
By te7 Data1_L
Byte8 Data2_H
PM4.0 concentration (standard particulate matter)
Byte9 Data2_L
Byte10 Data3_H
PM10 concentration (standard particulate matter)
Byte11 Data3_L
Byte12 Data4_H
reserve
Byte13 Data4_L
Byte14 Data5_H
reserve
Byte15 Data5_L
Byte16 Data6_H
reserve
Byte17 Data6_L
Byte18 Data7_H
reserve
Byte19 Data7_L
Byte20 Data8_H
reserve
Byte21 Data8_L
Byte22 Data9_H
reserve
Byte23 Data9_L
Byte24 Data10_H
reserve
Byte25 Data10_L
Byte26 Data11_H
reserve
Byte27 Data11_L
Byte28 Data12_H
reserve
Byte29 Data12_L
Byte30 CheckSum_H Checksum = Head0+Head1+Len_H+Len_L+Data0_
Byte31 CheckSum_L H+…+Data12_L
8sensing.honeywell.com
Particulate Matter Sensors
HPM Series
Figure 2. Standard Mounting Dimensions and Correct Installation Orientations (For reference only. (mm/[in])
Mount with 3 ST2.2 screws;
length determined by customer.
3X
ø
1,75
[0.07]
36,00
[1.42]
Air inlet
15,5
[0.61]
12
[0.48]
1,5
[0.06]
4,5
[0.18]
43,00
[1.69]
36,00
[1.42]
29,00
[1.14]
Air outlet by fan
Mating connector: Molex 51021-0800
23,7
[0.93]
Product Installation
Install the product to the desired surface using the screw size
shown in the applicable figure.
NOTICE
IMPROPER INSTALLATION
To avoid particulate settling or accumulation at the air
outlet or air inlet, which may affect product sensitivity and
accuracy, ensure that the HPM Series Particle Sensor:
Is installed correctly according to Figure 2, 3, or 4.
Is installed such that the air inlet and air outlets are not
blocked and that the flow of air through the sensor is
neither reduced nor increased.
Correct Installation Orientations
CAUTION
PRODUCT DAMAGE
Ensure adherance to all installation instructions.
Failure to comply with these instructions could result in
product damage.
9
Sensing and Internet of Things
Particulate Matter Sensors
HPM Series
Figure 3. Compact Version HPMA115CO-003 Mounting Dimensions and Correct Installation Orientations
(For reference only: mm/[in])
44
[1.73]
36
[1.42]
1,5
[0.06]
12
[0.48]
5,3
[0.21]
2
[0.08]
2
[0.08]
10,3
[0.41]
2,5
[0.10]
6,4
[0.25] 2,6
[0.10]
Air outlet by fan
Air inlet
7
[0.26]
2X 1,1
[0.04]
3X 1,6
[0.01]
Mount with three 1,8 [0.071] self-tapping
screws; max. engagement is 3,5 [1.138].
3X
ø
1,5
[0.059]
Key
Mating connector: Samtec SFSD-05-28-H-5.00-SR
(cable assembly) or SFM-105-02-H-D (surface mount)
Correct Installation Orientations
10 sensing.honeywell.com
Particulate Matter Sensors
HPM Series
Figure 4. Compact Version HPMA115CO-004 Mounting Dimensions and Correct Installation Orientations
(For reference only: mm/[in])
44
[1.73]
36
[1.42]
10,3
[0.41]
2,5
[0.10]
6,4
[0.25] 2,6
[0.10]
12
[0.48]
Air outlet by fan
Air inlet
Mating connector: Samtec SFSD-05-28-H-5.00-SR
(cable assembly) or SFM-105-02-H-D (surface mount)
Mount with three 1,8 [0.071] self-tapping
screws; max. engagement is 3,5 [1.138].
3X
ø
1,5
[0.059]
Key
Correct Installation Orientations
32322552-F-EN | F | 05/19
© 2019 Honeywell International Inc. All rights reserved.
Honeywell Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
www. honeywell.com
For more information
Honeywell Sensing and Internet of
Things services its customers through a
worldwide network of sales offices and
distributors. For application assistance,
current specifications, pricing or the
nearest Authorized Distributor, visit
sensing.honeywell.com or call:
Asia Pacific +65 6355-2828
Europe +44 (0) 1698 481481
USA/Canada +1-800-537-6945
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship during the
applicable warranty period. Honeywell’s standard product
warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgment or
consult your local sales office for specific warranty details.
If warranted goods are returned to Honeywell during the
period of coverage, Honeywell will repair or replace, at its
option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole
remedy and is in lieu of all other warranties, expressed or
implied, including those of merchantability and fitness for
a particular purpose. In no event shall Honeywell be liable
for consequential, special, or indirect damages.
While Honeywell may provide application assistance
personally, through our literature and the Honeywell web site, it
is buyers sole responsibility to determine the suitability of the
product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
ADDITIONAL INFORMATION
The following associated literature is available on the
Honeywell web site at sensing.honeywell.com:
Sell sheet
Frequently Asked Questions (FAQs)