SPECIFICATION
25WAC-DC High Reliability IndustrialAdaptor GST25A series
GST25A05-P1J
GST25A07-P1J
GST25A09-P1J
GST25A12-P1J
GST25A15-P1J
GST25A18-P1J
GST25A24-P1J
GST25A28-P1J
GST25A48-P1J
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 8
SAFETY &
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GST25A05
7.5V
GST25A07
9V
GST25A09
12V
GST25A12
15V
GST25A15
18V
GST25A18
24V
GST25A24
28V
GST25A28
48V
GST25A48
80mVp-p 80mVp-p 80mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
47 ~ 63Hz
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC, I/P-FG:2121VDC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
674.55Khrs min. MIL-HDBK-217F(25 )℃
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
93*54*36mm (L*W*H)
209g; 60pcs/13.5Kg/1.12CUFT
CONNECTOR
PLUG
CABLE
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
4.0A 2.93A 2.55A 2.08A 1.66A 1.38A 1.04A 0.89A 0.52A
0 ~ 4.0A 0 ~ 2.93A 0 ~ 2.55A 0 ~ 1.66A 0 ~ 1.38A 0 ~ 1.04A
0 ~ 0.89A
0 ~ 0.52A
20W 22W 23W 25W
0 ~ 2.08A
25W 25W 25W 25W 25W
Protection type : Clamp by zener diode
See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
80mVp-p
85 ~ 264VAC
81.5% 84.5% 85% 86.5% 87% 87% 88% 88% 89%
110 ~ 140% rated output voltage
1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load
0.6A / 115VAC 0.35A / 230VAC
VOLTAGE RANGE Note.7
EMC
(Note. 9)
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃℃0.03% / (0 ~ 50 )
Cold start 35A / 115VAC 65A / 230VAC
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The demand for Malaysia safety is processed with the order no. GST25A -SIRIM by request. Please contact MEAN WELL for details.
9.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1 , BIS IS13252,,AS/NZS 60950.1
KC K60950-1, approvedEAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
Level 3, 8KV air; Level 2, 4KV contact
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 >.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods>
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ
μ
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
EFT bursts
Surge susceptibility
Level 3, 8KV air; Level 2, 4KV contact
Conducted susceptibility
Level 2, 3V/m
Level 4, 2KV/Line-Line , 4KV/Line-FG
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
RF field
susceptibility
Magnetic field
immunity
Voltage dips , interruption
File Name:GST25A-SPEC 2017-05-05