Printed in USA 10/04 P/N 116165
Installation
Guide
Q25 Sensors dc-Voltage Series
Self-contained, dc-operated sensors
* Standard 2 m (6.5') cable models are listed.
9 m (30') cable: add suffix “W/30” (e.g., Q256E W/30).
4-pin Euro-style QD models: add suffix “Q” (e.g., Q256EQ). A model with a QD connector requires a
mating cable.
WARNING . . . Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection.
Doing so could lead to serious injury or death. These sensors do
NOT include the self-checking redundant circuitry necessary to allow their use in
personnel safety applications. A sensor failure or malfunction can cause either
an energized or de-energized sensor output condition. Consult your current
Banner Safety Products catalog for safety products which meet OSHA, ANSI and
IEC standards for personnel protection.
!
Sensing Mode Range LED Output Model*
Opposed 20 m (66') Infrared
950 nm
Q256E
NPN Q25SN6R
PNP Q25SP6R
Polarized
Retro-
reflective
2 m (79")
Visible
Red
680 nm
NPN Q25SN6LP
PNP Q25SP6LP
Fixed
Field
25 mm (1")
cutoff
Infrared
880 nm
NPN Q25SN6FF25
PNP Q25SP6FF25
50 mm (2")
cutoff
NPN Q25SN6FF50
PNP Q25SP6FF50
100 mm (4")
cutoff
NPN Q25SN6FF100
PNP Q25SP6FF100
Additional information on this product is immediately available online at www.bannerengineering.com/116165
View or download additional information, including excess gain curves, beam patterns and accessories.
For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.
Dimensions
LISTED
R
bn
bu
wh
bk
+10 - 30V dc
Load
Load
12.7 mm
(0.50")
Green LED
Power Indicator
Yellow LED
Output Indicator
Cabled Models QD Models
Cabled Emitters
25.0 mm
(0.98")
35.0 mm
(1.38")
30.0 mm*
(1.18")
12.4 mm
(0.49")
(Jam Nut Supplied)
Lens Centerline
15.2 mm
(0.60")
M18 x 1 Thread
2 m (6.5') Cable
*Fixed-field models = 31.0 mm (1.22")
bu
bn
wh
bk
10 - 30V dc
Load
Alarm
+
bn
bu 10-30V dc
+
NPN (Sinking) Outputs
Standard Hookup
10-30V dc
No Connection
bu
bk
bn
wh
+
P
PNP (Sourcing) Outputs
Standard Hookup
QD Emitters
Alarm Hookup
Alarm Hookup
bu
bn
wh
bk
+
10 - 30V dc
Load
Load
bn
bu
wh
bk
10 - 30V dc
Load
Alarm
+
NOTE: QD hookups are functionally identical.
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com
Q25 Sensors dc-Voltage Series
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for
one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its
manufacture found to be defective at the time it is returned to the factory during the warranty
period. This warranty does not cover damage or liability for the improper application of
Banner products. This warranty is in lieu of any other warranty either expressed or implied.
P/N 116165
Supply Voltage and Current (exclusive of load current): 10 to 30V dc (10% max.
ripple); supply current (exclusive of load current):
Emitters: 25 mA
Receivers: 20 mA
Polarized Retroreflective: 30 mA
Fixed-Field: 35 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
SPDT solid-state dc switch; Choose NPN (current sinking) or PNP (current
sourcing) models
Light Operate: N.O. output conducts when sensor sees its own (or the
emitter’s) modulated light
Dark Operate: N.C. output conducts when the sensor sees dark; the N.C.
(normally closed) output may be wired as a normally open
marginal signal alarm output, depending upon hookup to power
supply (U.S. patent 5087838)
Output Rating
150 mA maximum (each) in standard hookup. When wired for alarm output, the
total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp @ 30V dc
ON-state saturation voltage: < 1V at 10 mA dc; < 1.5V at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short
circuit of outputs
Output Response Time
Opposed mode: 3 ms ON, 1.5 ms OFF
Polarized Retro and Fixed-Field: 3 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do not conduct during this time.
Repeatability
Opposed mode: 375 µs
Polarized Retro and Fixed-Field: 750 µs
Repeatability and response are independent of signal strength.
Indicators
Two LEDs (Green and Yellow)
Green ON steady: power to sensor is ON
Green flashing: output is overloaded
Yellow ON steady: N.O. output is conducting
Yellow flashing: excess gain marginal (1 to 1.5x) in light condition
Construction
PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m (6.5') or 9 m (30') attached cable, or 4-pin Euro-style quick-disconnect
fitting
Operating Conditions
Temperature: -40° to +70°C (-40° to +158°F)
Maximum relative humidity: 90% at 50°C (non-condensing)
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration;
frequency 10 to 60 Hz, max., double amplitude 0.06" acceleration 10G).
Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
Certifications
Specifications
Quick-Disconnect (QD) Cables
Additional information on this product is immediately available online at www.bannerengineering.com/116165
View or download additional information, including excess gain curves, beam patterns and accessories.
For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.
Style Model Length Dimensions Pinout
4-pin
Euro-style
Straight
MQDC-406
MQDC-415
MQDC-430
2 m (6.5')
5 m (15')
9 m (30')
4-pin
Euro-style
Right-angle
MQDC-406RA
MQDC-415RA
MQDC-430RA
2 m (6.5')
5 m (15')
9 m (30')
38 mm max.
(1.5")
M12 x 1
ø 15 mm
(0.6")
38 mm max.
(1.5")
M12 x 1
ø 15 mm
(0.6")
44 mm max.
(1.7")
White Wire
Brown Wire
Black Wire
Blue Wire