Installation Guide Q25 Sensors - dc-Voltage Series Self-contained, dc-operated sensors Additional information on this product is immediately available online at www.bannerengineering.com/116165 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767. Sensing Mode Range LED Output - Opposed 20 m (66') Polarized Retroreflective P LISTED Cabled Emitters + bu - 50 mm (2") cutoff Fixed Field bn + - 10-30V dc bk No Connection wh 100 mm (4") cutoff - 10 - 30V dc + 30.0 mm* (1.18") 25.0 mm (0.98") 35.0 mm (1.38") Standard Hookup + - + - 10 - 30V dc Load Alarm NOTE: QD hookups are functionally identical. Printed in USA NPN Q25SN6LP PNP Q25SP6LP NPN Q25SN6FF25 PNP Q25SP6FF25 NPN Q25SN6FF50 PNP Q25SP6FF50 NPN Q25SN6FF100 PNP Q25SP6FF100 Yellow LED Output Indicator Green LED Power Indicator Lens Centerline *Fixed-field models = 31.0 mm (1.22") M18 x 1 Thread (Jam Nut Supplied) 12.7 mm (0.50") 2 m (6.5') Cable 10 - 30V dc Load Load Alarm Hookup bu bn bk wh Q25SP6R 15.2 mm (0.60") PNP (Sourcing) Outputs bn bu bk wh PNP 12.4 mm (0.49") - 10 - 30V dc + Load Alarm Q25SN6R QD Models Cabled Models Alarm Hookup bn bu bk wh NPN Dimensions Standard Hookup Load Load Q256E * Standard 2 m (6.5') cable models are listed. * 9 m (30') cable: add suffix "W/30" (e.g., Q256E W/30). * 4-pin Euro-style QD models: add suffix "Q" (e.g., Q256EQ). A model with a QD connector requires a mating cable. NPN (Sinking) Outputs bu bn bk wh Infrared 880 nm 10-30V dc QD Emitters bu Visible Red 680 nm 25 mm (1") cutoff R bn 2 m (79") Infrared 950 nm Model* ! WARNING . . . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection. 10/04 P/N 116165 Q25 Sensors - dc-Voltage Series Specifications Supply Voltage and Current (exclusive of load current): 10 to 30V dc (10% max. ripple); supply current (exclusive of load current): Emitters: 25 mA Receivers: 20 mA Polarized Retroreflective: 30 mA Fixed-Field: 35 mA Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Configuration SPDT solid-state dc switch; Choose NPN (current sinking) or PNP (current sourcing) models Light Operate: N.O. output conducts when sensor sees its own (or the emitter's) modulated light Dark Operate: N.C. output conducts when the sensor sees dark; the N.C. (normally closed) output may be wired as a normally open marginal signal alarm output, depending upon hookup to power supply (U.S. patent 5087838) Output Rating 150 mA maximum (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA. OFF-state leakage current: < 1 microamp @ 30V dc ON-state saturation voltage: < 1V at 10 mA dc; < 1.5V at 150 mA dc Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short circuit of outputs Output Response Time Opposed mode: 3 ms ON, 1.5 ms OFF Polarized Retro and Fixed-Field: 3 ms ON and OFF NOTE: 100 ms delay on power-up; outputs do not conduct during this time. Repeatability Opposed mode: 375 s Polarized Retro and Fixed-Field: 750 s Repeatability and response are independent of signal strength. Indicators Two LEDs (Green and Yellow) Green ON steady: power to sensor is ON Green flashing: output is overloaded Yellow ON steady: N.O. output is conducting Yellow flashing: excess gain marginal (1 to 1.5x) in light condition Construction PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens Environmental Rating Leakproof design rated NEMA 6P, DIN 40050 (IP69K) Connections 2 m (6.5') or 9 m (30') attached cable, or 4-pin Euro-style quick-disconnect fitting Operating Conditions Temperature: -40 to +70C (-40 to +158F) Maximum relative humidity: 90% at 50C (non-condensing) Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06" acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation) Certifications R LISTED Quick-Disconnect (QD) Cables Style 4-pin Euro-style Straight Model MQDC-406 MQDC-415 MQDC-430 Length 2 m (6.5') 5 m (15') 9 m (30') Dimensions Pinout o 15 mm (0.6") 44 mm max. (1.7") M12 x 1 White Wire Brown Wire Blue Wire 38 mm max. (1.5") 4-pin Euro-style Right-angle MQDC-406RA MQDC-415RA MQDC-430RA 2 m (6.5') 5 m (15') 9 m (30') Black Wire 38 mm max. (1.5") M12 x 1 o 15 mm (0.6") Additional information on this product is immediately available online at www.bannerengineering.com/116165 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767. WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 116165 Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 * Phone: 763.544.3164 * www.bannerengineering.com * Email: sensors@bannerengineering.com