SCD SPECIFICATION CONTROL DRAWING Title AUTOMATIC TRANSMISSION CABLE, RADIATION-CROSSLINKED, MODIFIED FLUOROPOLYMER-INSULATED, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 63. CONDUCTOR - TIN-COATED COPPER ATF+0311 Date Revision 1-29-15 H INSULATION - RADIATION-CROSSLINKED, MODIFIED FLUOROPOLYMER TABLE I. CONSTRUCTION DETAILS WIRE SIZE (AWG) CONDUCTOR STRANDING (number x AWG) ATFC0311-22-* 22 ATFC0311-20-* 20 ATFC0311-18-* ATFC0311-16-* PART NUMBER 1/ CONDUCTOR DIAMETER (inch) (mm) LOWER SPEC LIMIT UPPER SPEC LIMIT 19 x 34 .029 (.737) .031 (.787) 19 x 32 .037 (.940) .039 (.991) 18 19 x 30 .046 (1.17) 16 19 x 29 .052 (1.32) ATFC0311-14-* 14 19 x 27 ATFD0311-16-* 16 ATFD0311-14-* 14 FINISHED CABLE MAXIMUM RESISTANCE AT 20C (ohms/1000 ft.) (ohms/km) DIAMETER (inch) (mm) NOMINAL WEIGHT (lbs/1000 ft.) (kg/km) LOWER SPEC LIMIT TARGET VALUE UPPER SPEC LIMIT 16.2 (53.1) .044 (1.12) .046 (1.17) .048 (1.22) 3.0 (4.46) 9.88 (32.4) .052 (1.32) .054 (1.37) .056 (1.42) 4.4 (6.55) .049 (1.24) 6.23 (20.4) .061 (1.55) .063 (1.60) .065 (1.65) 6.6 (9.82) .055 (1.40) 4.81 (15.8) .066 (1.68) .069 (1.75) .072 (1.83) 8.3 (12.4) .065 (1.65) .069 (1.75) 3.06 (10.0) .083 (2.11) .086 (2.18) .089 (2.26) 12.9 (19.2) 37 x 32 .051 (1.30) .056 (1.42) 4.98 (16.3) .067 (1.70) .070 (1.78) .073 (1.85) 8.5 (12.6) 37 x 30 .067 (1.70) .072 (1.83) 3.11 (10.2) .089 (2.26) .093 (2.36) .097 (2.46) 15.5 (23.1) Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS SHALL BE IN ACCORDANCE WITH SAE J1128. COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH SPEC 63. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Dexron, Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Page 1 of 2 DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Raychem Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 (c) 2010-2015 Tyco Electronics Corporation. All rights reserved. Page SPECIFICATION CONTROL DRAWING 2 of 2 Revision SCD ATF+0311 H TABLE II. PERFORMANCE DETAILS HEAT RESISTANCE - BEND TESTING PART NUMBER 1/ MANDREL DIAMETER (inch) (mm) ( 3%) WEIGHT (lb) (kg) ( 3%) DYNAMIC CUT-THROUGH (lb) (kg) (minimum) INITIAL AFTER IMMERSION ATFC0311-22-* .750 (19.1) .375 (.170) TBD TBD ATFC0311-20-* .750 (19.1) .375 (.170) 20 (9.07) 20 (9.07) ATFC0311-18-* .750 (19.1) .375 (.170) TBD TBD ATFC0311-16-* .750 (19.1) .375 (.170) TBD TBD ATFC0311-14-* .750 (19.1) .375 (.170) TBD TBD ATFD0311-16-* 1.00 (25.4) .500 (.227) TBD TBD ATFD0311-14-* 1.00 (25.4) .500 (.227) TBD TBD CABLE RATINGS AND ADDITIONAL REQUIREMENTS VOLTAGE RATING: 600 volts (dc) at sea level CONCENTRICITY: 70% (minimum) CROSSLINK PROOF TEST: Per QC/3/117 FLAMMABILITY: 70 seconds (maximum) afterburn HEAT RESISTANCE: 150 2C for 1 hour no cracking, no dielectric breakdown INSULATION ELONGATION AND TENSILE STRENGTH: (Pulled at 2 inches (51 mm) per minute) Elongation, 150% (minimum) Tensile Strength, 3000 lbf/in2 (20.7 N/mm2) (minimum) INSULATION FLAWS: Impulse Dielectric, ATFC0311, 14 AWG and smaller, 5.0 kV (peak) ATFD0311-16, 5.0 kV (peak) ATFD0311-14, 6.0 kV (peak) INSULATION RESISTANCE: 1000 kohms for 1000 ft. (305 kohms for 1 km) (minimum) LOW TEMPERATURE-COLD BEND: -55 3C for 4 hours SHRINKAGE: 0.050 inch (1.27 mm) (maximum) STRIP FORCE: 4.5 lbs (2.04 kg) (minimum) 1/ See footer section on page 1 THERMAL STABILITY: Short Term, 200 3C for 168 hours Elongation Retention, 80% (minimum) Tensile Strength Retention, 80% (minimum) TRANSMISSION FLUID RESISTANCE: Dexron VI, 150 2C for 720 hours Diameter Swell, 5% (maximum) Mandrel Wrap, 1x diameter mandrel, no dielectric breakdown Dynamic Cut-Through, see Table II VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute 1/ PART NUMBER: The "+" in the part number in the upper right hand corner of pages 1 and 2 shall be replaced with a letter designator to define conductor stranding (see part numbers in table). C = 19 Strands D = 37 Strands The "*" in the part numbers in Tables I and II shall be replaced by a color code designator. Example: AWG 20, 19 strands, dark blue: ATFC0311-20-6D