Performance Characteristics
Bandwidth 100 MHz
Real Time Sampling Rate Single Channel: 1 GSa/s
Dual Channel: 500 MSa/s (for timebase faster than 250 ns/div)
Channels 2
Rise time < 3.5 ns
Record Length
40,000 points when timebase is 2.5 ns to 50 ns (20,000 points
for 100 ns to 50 ms timebase), 20,000 points for dual channel
operation
Vertical Resolution 8 bit
Vertical Sensitivity 2 mV/div -10 V/div (1-2-5 order)
DC Gain Accuracy <±3.0%: 5 mV/div to 10 V/div in fixed gain ranges
<±4.0%: 2 mV/div in variable gain ranges
Maximum input voltage 400 V (DC+AC pk-pk, 1 MΩ input impedance, X10), CAT I
Position Range 2 mV - 200 mV: ±1.6 V
206 mV - 10 V: ±40 V
Horizontal Scan Range 2.5 ns/div - 50 s/div
Scan mode: 100 ms/div - 50 s/div (1 - 2.5 - 5 sequence)
Timebase Accuracy ±50 ppm measured over 1 ms interval
Input Coupling AC, DC, GND
Input Impedance 1 MΩ±2% || 16 pF±3 pF
Vertical and Horizontal Zoom Vertically or horizontally expand or compress a live or
stopped waveform
I/O interface
USB host port on front panel supports USB flash drives,
RS-232 and USB (USBTMC-compliant) device port
for connection to PC, Pass/Fail output
Acquisition Modes
Sample Display sample data only
Peak Detect Capture the maximum and minimum values of a signal
Average Waveform averaged, selectable from 4, 16, 32, 64, 128, 256
Scan Mode For time base settings 0.1 s/div - 50 s/div
Trigger System
Trigger Types
Edge, Pulse Width, Video*, Slope, Alternating
*Support signal Formats: PAL/SECAM, NTSC
Trigger condition : odd field, even field, all lines, or line number
Trigger Modes Auto, Normal, Single
Trigger Coupling AC, DC, LF reject, HF reject
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Pulse Width Trigger Trigger Modes: (>,<,=) Positive Pulse Width,
(>,<,=) Negative Pulse Width
Slope Trigger (>,<,=) Positive slope, (>,<,=) Negative slope
Time: 20 ns -10 s
Hardware Frequency Counter
Reading Resolution 1 Hz
Accuracy ±0.01%
Range DC Couple, 10 Hz to 100 MHz
Signal Types All trigger signals (except pulse width trigger
and video trigger)
Waveform Math and Measure
Math operation Add, Subtract, Multiply, Divide, FFT
FFT Window mode: Hanning, Hamming, Blackman, Rectangular
Sampling points: 1024
Measure
Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean, Crms, Vrms,
ROV, FOV, RPRE, FPRE,
FREQ, Period, Rise Time, Fall Time, BWid, + Wid, - Wid,
+ Duty, - Duty, Phase, FRR, FRF,
FFR, FFF, LRR, LRF, LFR, LFF
Display System
Display 7 in. Color TFT, 480 x 234 resolution, 64K color
Display Contrast (Typical state) 150:1
Backlight Intensity (Typical state) 300 nit
Display Area 8 x 18 div
Display Mode Dots, Vector
Persistence Off, 1 sec, 2 sec, 5 sec, Infinite
Menu Display Timer 2 sec, 5 sec, 10 sec, 20 sec, Infinite
Screen-Saver Off, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min,
1 hour, 2 hour, 5 hour
Waveform Interpolation Sin(x)/x, Linear
Display Color Mode Normal, Invert
Environment
Temperature Operating: 50° F to 104 °F (10 °C to 40 °C)
Not operating: -4 °F to 140 °F (-20 °C to 60 °C)
Humidity Operating: 85% RH, 104 °F (40 °C)
Not operating: 85% RH, 149 °F (65 °C)
Altitude Operating: 9,842 ft (3,000 m)
Not operating: 50,085 ft (15,266 m)
Electromagnetic Compatibility EMC Directive 2004/108/EC,
EN61326:2006
Safety Low voltage directive 2006/95/EC, EN61010-1:2001
General
AC Input 100-240 VAC, CAT II, 50 VA max, 45 Hz to 440 Hz
Dimension (WxHxD) 12.7 x 5.35 x 5.24 inches (323 x 136 x 157 mm)
Weight 5.5 lbs. (2.5 kg)
One-Year Warranty
Standard Accessories User Manual, 10:1 Probe Set (2 pieces), Power Cord,
USB Interface Cable
Optional Accessories USB-to-GPIB adapter (model AK40G)