100 MHz Digital Storage Oscilloscope
Model 2190D
Data Sheet
www.bkprecision.com
Technical data subject to change
© B&K Precision Corp. 2014
The 2190D combines performance and value all
in one portable solution. With 100 MHz
bandwidth and 1 GSa/s sample rate, these
oscilloscopes offer advanced triggering
capabilities, long waveform memory up to 40,000
points, and extensive features such as pass/fail
limit testing, digital filtering, waveform recorder,
and 32 automatic measurements.
Engineered to allow you to see more of your
signal under test, the 2190D widescreen 7” TFT
display offers a significantly larger viewing area
than typical economy oscilloscopes (5.7”).
Maximize productivity with PC connectivity via
RS232 and USB. The downloadable PC software
lets you easily capture, save, and analyze
measurement results. All oscilloscope parameters
can be controlled via a PC without the need for
programming.
The 2190D oscilloscope is ideal for applications
in education, design and debug, service and
repair.
Features & Benefits
100 MHz, I GSa/s sample rate
Large 7” widescreen color display
Long waveform memory up to 40,000 points
Five different math functions – Add, Subtract,
Multiply, Divide, and FFT
Versatile triggering capabilities including pulse
width, line-selectable video, slope, and
alternating trigger
32 automatic measurements
Advanced tools include digital filter with
adjustable limits, pass/fail testing, and
waveform recorder mode
12 different language user interfaces and
context sensitive help
Special EDU mode allows educators to disable
Auto set button, Measure menu, and Cursors
menu
Front panel USB host port for saving and
recalling waveform setups, data, and screen
shots on a USB flash drive
USBTMC-compliant USB device port for
remote PC control
GPIB connectivity with optional USB-to-GPIB
adapter
PC connectivity
PC software is provided (free download at B&K
Precision’s website at www.bkprecision.com) for
seamless integration between the oscilloscope
and PC. Capture and transfer waveforms, screen
images, setups and measurement results to a
Windows PC via the USB device port on the
back of the instrument. A USB host port on the
front and rear allows for quick and easy screen
saving.
www.bkprecision.com
Digital Storage Oscilloscope
Model 2190D
2
Widescreen display
The 7" widescreen color
display lets you see more
of your signal.
Waveform analysis with math
and FFT
Analyze your signals with add, subtract,
multiply, and divide functions. View the
signal’s frequency spectrum and perform
harmonic distortion analysis.
Menu On/Off button
Configure the menu parameters and
hide the menu with the push of a button
to view your signal in full screen.
Context sensitive help
A pop up window will
display the functionality of
a control while help mode
is active.
Auto setup
Vertical, horizontal,
and trigger controls
are automatically
adjusted for fast signal
display.
USB host port
Connect your USB flash
drive to conveniently
store and recall wave-
form data, setups, and
screenshots.
Print button
Simply press the Print
button to save a
screenshot in bitmap
format to a USB flash
drive.
Advanced trigge ri ng
Isolate the signal with
advanced triggering
including pulse width and
selectable video trigger.
Ke nsington security slot
Helps to secure your
oscilloscope and prevent theft.
Communication
RS232 and USB ports enable
remote control from a PC
Front panel
Rear panel
Security loop
Use the built-in security loop to
secure your instrument to your
location.
www.bkprecision.com
Digital Storage Oscilloscope
Model 2190D
3
The tools you need
Display and measure the input signal’s frequency spectrum. Select
one of the 4 FFT windows: Rectangular, Hanning, Hamming, and
Blackman. Use cursors to measure the spectral component’s
magnitude and frequency.
Monitor and analyze long-term signal behavior by recording data
continuously over an extensive period of time and playing it back for
post acquisition analysis. Data is recorded in a sequence of up to
2500 frames.
Minimize debug time by saving and recalling setups and waveforms
from internal memory. Save and recall up to 20 different oscilloscope
setups and 10 different waveforms.
Filter out unwanted signal components such as various types of noise
with built-in digital filters. Choose from Low-Pass, High-Pass,
Band-Pass, and Band-Stop filters.
Generate user-defined pass/fail limits to quickly identify go/no go
test results.
Use the oscilloscope’s delayed sweep feature to zoom in a particular
area of a signal in real time while viewing the entire captured
waveform simultaneously.
Powerful measurement functions Digital filtering
Waveform recorder Delayed sweep/zoom
Large internal storage Pass/Fail testing
Filter OFF
Filter ON
v081814
4 www.bkprecision.com
Digital Storage Oscilloscope
Model 2190D
Model 2190D
Performance Characteristics
Bandwidth 100 MHz
Real Time Sampling Rate Single Channel: 1 GSa/s
Dual Channel: 500 MSa/s (for timebase faster than 250 ns/div)
Channels 2
Rise time < 3.5 ns
Record Length
40,000 points when timebase is 2.5 ns to 50 ns (20,000 points
for 100 ns to 50 ms timebase), 20,000 points for dual channel
operation
Vertical Resolution 8 bit
Vertical Sensitivity 2 mV/div -10 V/div (1-2-5 order)
DC Gain Accuracy <±3.0%: 5 mV/div to 10 V/div in fixed gain ranges
<±4.0%: 2 mV/div in variable gain ranges
Maximum input voltage 400 V (DC+AC pk-pk, 1 M input impedance, X10), CAT I
Position Range 2 mV - 200 mV: ±1.6 V
206 mV - 10 V: ±40 V
Horizontal Scan Range 2.5 ns/div - 50 s/div
Scan mode: 100 ms/div - 50 s/div (1 - 2.5 - 5 sequence)
Timebase Accuracy ±50 ppm measured over 1 ms interval
Input Coupling AC, DC, GND
Input Impedance 1 M±2% || 16 pF±3 pF
Vertical and Horizontal Zoom Vertically or horizontally expand or compress a live or
stopped waveform
I/O interface
USB host port on front panel supports USB flash drives,
RS-232 and USB (USBTMC-compliant) device port
for connection to PC, Pass/Fail output
Acquisition Modes
Sample Display sample data only
Peak Detect Capture the maximum and minimum values of a signal
Average Waveform averaged, selectable from 4, 16, 32, 64, 128, 256
Scan Mode For time base settings 0.1 s/div - 50 s/div
Trigger System
Trigger Types
Edge, Pulse Width, Video*, Slope, Alternating
*Support signal Formats: PAL/SECAM, NTSC
Trigger condition : odd field, even field, all lines, or line number
Trigger Modes Auto, Normal, Single
Trigger Coupling AC, DC, LF reject, HF reject
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Pulse Width Trigger Trigger Modes: (>,<,=) Positive Pulse Width,
(>,<,=) Negative Pulse Width
Slope Trigger (>,<,=) Positive slope, (>,<,=) Negative slope
Time: 20 ns -10 s
Hardware Frequency Counter
Reading Resolution 1 Hz
Accuracy ±0.01%
Range DC Couple, 10 Hz to 100 MHz
Signal Types All trigger signals (except pulse width trigger
and video trigger)
Waveform Math and Measure
Math operation Add, Subtract, Multiply, Divide, FFT
FFT Window mode: Hanning, Hamming, Blackman, Rectangular
Sampling points: 1024
Measure
Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean, Crms, Vrms,
ROV, FOV, RPRE, FPRE,
FREQ, Period, Rise Time, Fall Time, BWid, + Wid, - Wid,
+ Duty, - Duty, Phase, FRR, FRF,
FFR, FFF, LRR, LRF, LFR, LFF
Display System
Display 7 in. Color TFT, 480 x 234 resolution, 64K color
Display Contrast (Typical state) 150:1
Backlight Intensity (Typical state) 300 nit
Display Area 8 x 18 div
Display Mode Dots, Vector
Persistence Off, 1 sec, 2 sec, 5 sec, Infinite
Menu Display Timer 2 sec, 5 sec, 10 sec, 20 sec, Infinite
Screen-Saver Off, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min,
1 hour, 2 hour, 5 hour
Waveform Interpolation Sin(x)/x, Linear
Display Color Mode Normal, Invert
Environment
Temperature Operating: 50° F to 104 °F (10 °C to 40 °C)
Not operating: -4 °F to 140 °F (-20 °C to 60 °C)
Humidity Operating: 85% RH, 104 °F (40 °C)
Not operating: 85% RH, 149 °F (65 °C)
Altitude Operating: 9,842 ft (3,000 m)
Not operating: 50,085 ft (15,266 m)
Electromagnetic Compatibility EMC Directive 2004/108/EC,
EN61326:2006
Safety Low voltage directive 2006/95/EC, EN61010-1:2001
General
AC Input 100-240 VAC, CAT II, 50 VA max, 45 Hz to 440 Hz
Dimension (WxHxD) 12.7 x 5.35 x 5.24 inches (323 x 136 x 157 mm)
Weight 5.5 lbs. (2.5 kg)
One-Year Warranty
Standard Accessories User Manual, 10:1 Probe Set (2 pieces), Power Cord,
USB Interface Cable
Optional Accessories USB-to-GPIB adapter (model AK40G)