MODEL TL-5935 International size reference: 1/6D, ER32L100 TECHNICAL DATA (Typical values @+25C for batteries stored for one year or less) Nominal capacity @ 1 mA, to 2V Rated voltage Maximum recommended continuous current Maximum pulse current capability Weight Volume Operating temperature range Li metal content U.L. Component Recognition, MH 12193 Volts 1.7 Ah 3.6 V 10 mA 50 mA 21 g (0.74 oz) 8.2 cc -55C to +85C approx. 0.5 g DISCHARGE CHARACTERISTICS @ +25C 4.0 3.5 3.0 2.5 2.0 1.1 K 3.6 K 6.8 K 18 K ~3 mA ~1 mA ~0.5 mA ~0.2 mA (1.7 Ah) (1.7 Ah) (1.65 Ah) (1.59 Ah) 1.5 180 K 100 K ~20 A ~36 A (1.51 Ah) (1.32 Ah) ORDERING NO. TERMINAL MATERIAL : 1.0 1 10 100 1000 10000 VOLTAGE VS. TEMPERATURE Volts CAPACITY VS. CURRENT 1.7 3.6 1.5 3.5 0C 25C 20 A 3.4 1.3 30 A 0.2 mA 0.9 0.5 mA 1 mA 3.0 50C 1.1 3.2 3.1 15-5935-41500 100000 Hours Ah 3.7 3.3 TIN PLATED NICKEL CATALOGUE NO. : 85C 0.7 -30C 3 mA -40C 2.9 0.5 -60 -40 -20 0 20 40 60 80 C 0.01 0.1 1 mA iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 1501879 Rev. B 11/08 Page 1 of 2 TL-5935 CELL FEATURES 3.6 V Primary lithium-thionyl chloride (Li-SOCl2) Fast voltage recovery after long term storage and/or usage High energy density High and stable operating voltage Low self discharge rate Wafer construction Hermetic glass-to-metal-sealing Non-flammable electrolyte Volts 3.5 MAIN APPLICATIONS VOLTAGE RESPONSE AFTER STORAGE After 1 year After 2 years 3.4 After 5 years 3.3 After 10 years Utility meters (elect., water & gas) Automatic meter reading RF systems Sensors & monitoring systems Tracking systems Wireless security systems Automotive electronics Industrial electronics Ultra Low Power (ULP) 3.2 STORAGE CONDITIONS 3.1 3.0 2.9 Pulse applied: 10 mA for 1 sec Storage: RT Background current: None 2.8 Cells should be stored in a clean & dry (less than 30 % RH) area 2.7 2.6 0 200 400 600 800 1000 VOLTAGE RESPONSE Volts For updated information please visit our website www.tadiranbat.com 1200 msec VOLTAGE RESPONSE Volts After 1 year 3.4 After 5 years 3.4 After 2 years After 1 year After 7 years After 5 years After 2 years After 10 years 3.3 3.2 3.3 3.2 Pulse applied: 10 mA for 100 msec Temperature: RT Background current: 7 A 3.1 Pulse applied: 10 mA for 100 msec Temperature: RT Background current: 15 A 3.1 0 20 40 60 80 100 120 msec 0 20 40 60 80 100 120 msec iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 1501879 Rev. B 11/08 Page 2 of 2