MYRRA - SERIE 44000 EI 42-14,8 5 VA
MYRRA - SERIE 44000 EI 42-14,8 5 VA
EI 42-14,8 SERIE 44000 5 VA
Primary Voltage 117 V
Secondary
Protection
mA Reference Secondary
Voltage
V
Secondary
Currant
m A
No-load
Voltage
V
Ambient,
Temperature
C
Rating
VA
800 44241 6 833 8,4 T 50 B 5
630 44242 9 556 12,6 T 50 B 5
400 44243 12 417 16,9 T 50 B 5
315 44244 15 333 21 T 50 B 5
315 44245 18 278 25,3 T 50 B 5
200 44246 24 33.7 32,1 T 50 B 5
400 44247 2 x 6 2 x 417 2 x 8,4 T 50 B 5
315 44248 2 x 9 2 x 278 2 x 12,6 T 50 B 5
200 44249 2 x 12 2 x 208 2 x 16,9 T 50 B 5
160 44250 2 x 15 2 x 167 2 x 21 T 50 B 5
160 44251 2 x 18 2 x 139 2 x 25,3 T 50 B 5
80 44252 2 x 24 2 x 104 2 x 33,7 T 50 B 5
EI 42-14,8 SERIE 44000 5 VA
Primary Voltage 230 V
Secondary
Protection
mA Reference Secondary
Voltage
V
Secondary
Currant
m A
No-load
Voltage
V
Ambient,
Temperature
C
Rating
VA
800 44229 6 833 8,4 T 50 B 5
630 44230 9 556 12,6 T 50 B 5
400 44231 12 417 16,9 T 50 B 5
315 44232 15 333 21 T 50 B 5
315 44233 18 278 25,3 T 50 B 5
200 44234 24 33.7 32,1 T 50 B 5
400 44235 2 x 6 2 x 417 2 x 8,4 T 50 B 5
315 44236 2 x 9 2 x 278 2 x 12,6 T 50 B 5
http://www.myrra.ie/44000-7.html (1 of 2)5/22/2007 3:47:44 PM
MYRRA - SERIE 44000 EI 42-14,8 5 VA
200 44237 2 x 12 2 x 208 2 x 16,9 T 50 B 5
160 44238 2 x 15 2 x 167 2 x 21 T 50 B 5
160 44239 2 x 18 2 x 139 2 x 25,3 T 50 B 5
80 44240* 2 x 24 2 x 104 2 x 33,7 T 50 B 5
* Vaccum filling
* Two compartments bobbins
* Self-extinguishing plastics UL 94 VO
* Degree of protection IP 00
* 200 grams weight
* Resin class B CEI 85
(20 000h testing to CEI 126)
* Fuse protection on secondary side (see diagram) to be assumed
by customer
* 30 V and 36 V model are VDE EN 60742 certified (production on
request)
* Insulation voltage 4 KV
(6 KV MYRRA test)
* 100% tested production
* Certification : CCA procedure on request
* To be noted : 2 * 24 V model is non approved. Protection
transformers according to EN 60742 circuit isolation tranformer.
http://www.myrra.ie/44000-7.html (2 of 2)5/22/2007 3:47:44 PM