https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge protective device, single channel with remote indicator contact for 120VAC Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626444895 Weight per Piece (excluding packing) 380.000 g Custom tariff number 85363030 Country of origin Germany Technical data Dimensions Height 98.7 mm Width 17.8 mm Depth 65.5 mm Horizontal pitch 1 Div. Ambient conditions Degree of protection IP20 (only when all terminal points are used) Ambient temperature (operation) -40 C ... 80 C Ambient temperature (storage/transport) -40 C ... 80 C Altitude 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % 05/19/2021Page1/9 https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Technical data Ambient conditions Shock (operation) 25g (Half-sine / 11 ms / 3x X, Y, Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General IEC test classification II T2 EN type T2 IEC power supply system TN-C Mode of protection L-PEN Mounting type DIN rail: 35 mm Color jet black RAL 9005 Housing material PA 6.6 PBT Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 1 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 120VAC (TN-C) Nominal frequency fN 50 Hz (60Hz) Rated load current IL 80 A Residual current IPE 0.45 mA Nominal discharge current In (8/20) s 20 kA Maximum discharge current Imax (8/20) s 40 kA Short-circuit current rating ISCCR 25 kA Voltage protection level Up 0.9 kV Residual voltage Ures 0.9 kV (at In) 0.75 kV (at 10 kA) 0.6 kV (at 5 kA) 0.55 kV (at 3kA) TOV behavior at UT 208 VAC (5s / withstand mode) 240 VAC (120min / safe failure mode) Response time tA 25 ns Max. backup fuse with V-type through wiring 80 A (gG) Max. backup fuse with branch wiring 125 A (gG) 05/19/2021Page2/9 https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Technical data Indicator/remote signaling Switching function Changeover contact Operating voltage 5 VAC ... 250 VAC 30 VDC Operating current 5 mA AC ... 1.5 A AC 1 ADC Connection method Screw connection Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm ... 1.5 mm Conductor cross section solid 0.14 mm ... 1.5 mm Conductor cross section AWG 28 ... 16 Connection data Connection method Screw connection Screw thread M5 Tightening torque 4.5 Nm (1.5mm ... 16mm) 4.5 Nm (25mm...35mm) Stripping length 16 mm Conductor cross section flexible 1.5 mm ... 25 mm Conductor cross section solid 1.5 mm ... 35 mm Conductor cross section AWG 15 ... 2 UL specifications SPD Type 1 Maximum continuous operating voltage MCOV 175 VAC Nom. voltage 120VAC (Single-phase) Mode of protection L-N Power distribution system Single phase Nominal frequency 50/60 Hz Voltage protection rating VPR 700 V Nominal discharge current In 20 kA Maximum Surge Current per Phase 40 kA Short-circuit current rating (SCCR) 200 kA UL indicator/remote signaling Operating voltage 125 VAC Operating current 1 A AC Tightening torque 2 lbf-in. ... 4 lbf-in. 05/19/2021Page3/9 https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Technical data UL indicator/remote signaling Conductor cross section AWG 30 ... 14 UL connection data Conductor cross section AWG 10 ... 2 Tightening torque 30 lbf-in. Standards and Regulations Standards/regulations IEC61643-11 2011 EN61643-11 2012 Drawings Dimensional drawing Circuit diagram 12 96,8 65,7 14 11 FM 17,6 44 89,8 Classifications eCl@ss eCl@ss 10.0.1 27130805 eCl@ss 11.0 27130805 eCl@ss 6.0 27130800 eCl@ss 7.0 27130805 eCl@ss 9.0 27130805 ETIM ETIM 6.0 EC000941 ETIM 7.0 EC000941 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed 05/19/2021Page4/9 https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Approvals Ex Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 cULus Listed Accessories Accessories Bridge Wiring bridge-MPB F600X16/ 1GS-2818355 Wiring bridge flexible, diameter: 16 mm, with a fork-type cable lug on one side, length: 600 mm Wiring bridge-MPB F600X16/ 1GS-2818355 Wiring bridge flexible, diameter: 16 mm, with a fork-type cable lug on one side, length: 600 mm 05/19/2021Page5/9 https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Accessories Wiring bridge-MPB F200X16/ 1GS-2818339 Wiring bridge flexible, diameter 16 mm, with a fork-type cable lug on one side, length: 200 mm Wiring bridge-MPB 18/1-10/1.0.0-2830443 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 10 pitches with contact sequence 1-0-0 Wiring bridge-MPB 18/4-12-2809296 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 12-pos. Wiring bridge-MPB 18/4- 8-2809283 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 8-pos. Wiring bridge-MPB 18/3- 6-2809241 Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 6-pos. 05/19/2021Page6/9 https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Accessories Wiring bridge-MPB 18/1-57-2809238 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 57-pos. Wiring bridge-MPB 18/1-12-2748593 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 12-pos. Wiring bridge-MPB 18/1- 9-2748580 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 9-pos. Wiring bridge-MPB 18/1- 8-2748577 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos. Wiring bridge-MPB 18/1- 6-2748564 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 6-pos. 05/19/2021Page7/9 https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Accessories Wiring bridge-MPB 18/1- 4-2809225 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 4-pos. Wiring bridge-MPB 18/1- 3-2809212 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos. Wiring bridge-MPB 18/1- 2-2809209 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos. Device marking Zack marker strip-ZBN 18:UNBEDRUCKT-2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Feed-through terminal block Feed-through terminal block-DK-BIC-35-2749880 Feed-through terminal block for VAL and FLT applications 05/19/2021Page8/9 https://www.phoenixcontact.com/us/products/2910348 Type 1 surge protection device-VAL-US-120/40/1+0-FM-2910348 Accessories Labeled device marker Marker for terminal blocks-ZBN 18,LGS:ERDE-2749589 Marker for terminal blocks, Strip, white, labeled, horizontal: Grounding symbol, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Marker for terminal blocks-ZBN 18,LGS:L1-N,ERDE-2749576 Marker for terminal blocks, Strip, white, labeled, horizontal: L1, L2, L3, N, GND, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Marker pen Marker pen-B-STIFT-1051993 Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm Spare parts Type 1 surge protection plug-VAL-US-120/40-P-2910335 UL Recognized type 1 SPD and IEC type 2 surge protection plug with a varistor and thermal disconnect for use with VALUS base elements, mechanical and visual fault warning Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 05/19/2021Page9/9