C-Series
C-Series
CIRCUIT BREAKER
The C-Series hydraulic-magnetic circuit breakers are ideal for applications that require higher amperage and
voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized
up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal
options, actuator styles and colors. The C-Series employs a unique arc chute design which allows for higher
interrupting capacities of up to 10,000 amps. New thermoset glass lled polyester half shell construction
provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two
step actuaction, clean contacts providing high, positive contact pressure and longer contact life. Available with
American Standard or Metric Threaded Stud terminals , or Saddle Clamp screw terminals. The optional mid-trip
handle style actuator allows a visual indication of electrical overload with or without alarm feature.
Product Highlights:
Extensive list of Agency Approvals
Available with Standard or Metric Stud terminals,
or Saddle Clamp screw terminals
Optional mid-trip handle style actuator
Unique arc chute design which allows for higher
interrupting capacities of up to 10,000 amps
Exclusive Rockerguard and Push-To-Reset bezel
Available with new solid color and two-color Visi-
rocker® actuators
New thermoset glass lled polyester half shell
construction
Typical Applications:
Marine
Telecom/Datacom
Military
Renewable Energy
Generators & Welders
Eco-Friendly
Resources:
Download 3D CAD Files
IGS STP
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
32 DC --- 0.02 - 100 --- --- 5000 TC1, OL1, U2 TC1, OL1, U2
48 DC --- 110 - 150 --- --- 5000 TC1, OL1, U2 TC1, OL1, U2
65 DC --- 0.02 - 70 --- --- 5000 TC1,2, OL1,U1 TC1,2, OL1,U1
--- 71 -100 --- 5000 TC1,2, OL0,U1 TC1,2, OL0,U1
0.02 - 70 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1
--- 71 -100 --- 7500 TC1,2, OL0,U1 TC1,2, OL0,U1
0.02 - 70 --- --- 10,000 TC1,2, OL1,U1 TC1,2, OL1,U1 Must Have Agency Code "L"
--- 71 -100 --- 10,000 TC1,2, OL0,U1 TC1,2, OL0,U1 Must Have Agency Code "L"
125 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L"
125 / 250 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L"
250 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L". 2 Pole Break Required for 250 Volts
0.02 - 100 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating
0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L"
150 DC --- --- 80 - 100 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L"
150 DC --- --- 101 - 175 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L" Parallel Pole
0.02 - 100 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2
0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase
51 - 100 --- --- 1000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase
0.02 - 100 --- --- 5000 TC1,2,OL1,U2 TC1,2,OL1,U2 2 or 3 poles breaking single phase, "L" Agency Code
0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating
0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L"
51 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
--- 0.02 - 100 --- 3000 TC1, OL0, U2 TC1, OL0, U2
0.02 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
--- 0.02 - 90 --- 5000 TC1,2,OL0,U1 TC1,2,OL0,U1 Must Have Agency Code "L"
277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
--- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1
0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 2 poles breaking 1 phase
--- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1
80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1
125 50 / 60 1 0.02 - 50 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating
0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 2 or 3 poles breaking single phase
0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase
1 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2
0.02 - 50 --- --- 3000 TC1, OL0, U2 TC1, OL0, U2 Per Pole Rating
0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1
277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
--- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1
0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 2 poles breaking 1 phase
--- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1
80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1
277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
0.02 - 70 --- --- --- --- ---
--- 71 -100 --- --- --- ---
0.02 - 70 --- --- --- --- ---
--- 71 -100 --- --- --- ---
125 50 / 60 1 0.02 - 100 --- --- --- --- ---
125 / 250 50 / 60 1 0.02 - 100 --- --- --- --- --- 2 or 3 poles breaking single phase
1 0.02 - 100 --- --- --- --- ---
3 0.02 - 70 --- --- --- --- ---
277 50 / 60 1 0.02 - 50 --- --- --- --- ---
0.02 - 30 --- --- --- --- --- 3 poles breaking 3 phase
--- 31 - 50 --- --- --- ---
125 / 250 50 / 60 1
DUAL COIL
C-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS
FULL LOAD
AMPS
SERIES
CIRCUIT
CONFIGURATION MAX.
RATING FREQUENCY
50 / 60
250 50 / 60
1
3
480 50 / 60 1
480 / 277 50 / 60
125 / 250
1
3
3
480 50 / 60 1
480 / 277 50 / 60
3
GENERAL
PURPOSE AMPS
DC
VOLTAGE
---80
80 DC
SHORT CIRCUIT CAPACITY (AMPS)
WITHOUT BACKUP
FUSE
WITH BACKUP
FUSE 1
SWITCH ONLY
480 / 277 50 / 60
250 50 / 60
DC
CURRENT RATING
RELAY
SHUNT
3
65 DC
80
250 50 / 60
---
---
125 50 / 60 1
NOTES
UL CSA
APPLICATION CODES
---
PHASE
UL/CSA
2 |C-Series – General Specications
Electrical Tables
Table A: Lists UL Recognized & CSA Accepted congurations and performance capabilities as a Component Supplementary
Protector
Notes for Table A:
1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and
not to exceed 175 for 51 through 100 Amp rating
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 3
C-Series – General Specications
Electrical Tables
Table B: Lists UL Recognized and CSA Accepted congurations and performance capabilities as a Manual Motor Controller.
Table C: Lists UL Recognized, CSA Accepted , VDE and TUV Certied congurations and performance capabilities as a
Component Supplementary Protector.
Notes for Table B:
1 UL recognized and CSA Accepted at 480V refers to 3 & 4 pole versions used in a 3Ø, wye connected circuit or 2-pole version connected with 2 poles breaking. 1Ø and backed up with
series fusing as stated above in note 1.
*Series, Shunt and Relay Trip - Voltage Coil Construction not current coils
Notes for Table C:
1 General Purpose ratings for UL/CSA only.
2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and
not to exceed 175 for 51 through 100 Amp rating.
RELAY
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
4 |C-Series – General Specications
Electrical Tables
Table D: Lists UL Listed (489), CSA Certied (C22.2 No. 5.1-M) conguration and performance capabilities as a Molded Case
Circuit Breaker.
Table E: Lists UL Recognized, CSA Accepted congurations and performance capabilities as Protectors, Supplementary for
Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classied Small Craft
Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
Table F: Lists UL Listed congurations and performance capabilities as Circuit Breakers for use in Communications Equipment
(Guide DITT, File E189195), under UL489A.
Notes from Table D:
1 Special catalog number required. Consult factory.
CURRENT
RATING
INTERRUPTING
CAPACITY
(AMPS)
50,000
1 Limited to 2 Poles Max from 71 - 100 Amps.
10,000 Limited to 2 Poles Max from 71 - 100 Amps.
125 DC --- 0.10 - 100 5,000 1 - 3 Poles
125 / 250 DC --- 0.10 - 50 5,000 1 or 2 Poles (2 Poles Required for 250 Volts)
0.10 - 50 10,000 1 - 3 Poles
51 - 70 5,000 1 - 3 Poles
0.10 - 50 5,000 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral
0.10 - 50 10000 1 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral
240 50 / 60 1 0.10 - 30 5,000 1Pole
240 50 / 60 1 0.10 - 20 5,000 2 Pole
277 50 / 60 1 0.10 - 20 10,000 1Pole
DUAL COIL 120 50 / 60 1 0.10 - 30 10,000 ---
CIRCUIT
CONFIGURATION FULL LOAD
AMPS
PHASE
VOLTAGE
1
0.10 - 100
50 / 60 1120 / 240
DC
CONSTRUCTION NOTES
C SERIES TABLE D : UL489 LISTED BRANCH CIRCUIT BREAKERS
SERIES 120
80
50 / 60
WITHOUT
BACKUP FUSE
MAX.
RATING FREQUENCY
---
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 5
C-Series – General Specications
Mechanical
Physical
Environmental
Electrical
0.1
0.10.01
0.001
0.01
1
10
100
1000
15%
25%
35%
1 10010
TOLERANCE
(%)
O
H
M
S
CURRENT
(AMPS)
FIGURE 1
0.100 - 5.0
5.1 - 20.0
20.1 - 100
RESISTANCE, IMPEDANCE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
AMPERE RATING
Time Delay Curves
42, 44 & 46
(50 Amps Max.)
16.67
t
Multiple of
Rated Current
r
I
4.165 8.33
25x
12x
20.0
Time Delay Curves
22, 24 (100 Amps Max.)
26 (70 Amps Max.)
Time in
Milliseconds
t
Time Delay Curves
22, 24 (100 Amps Max.)
26 (70 Amps Max.)
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
50 Hz 1/2 Cycle
Inrush Pulse Tolerance
10.0
Time Delay Curves
42, 44 & 46
(50 Amps Max.)
22x
10x
Multiple of
Rated Current
5.0
r
I
Time Delay Curves
42, 44 & 46
(50 Amps Max.)
16.67
t
Multiple of
Rated Current
r
I
4.165 8.33
25x
12x
20.0
Time Delay Curves
22, 24 (100 Amps Max.)
26 (70 Amps Max.)
Time in
Milliseconds
t
Time Delay Curves
22, 24 (100 Amps Max.)
26 (70 Amps Max.)
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
50 Hz 1/2 Cycle
Inrush Pulse Tolerance
10.0
Time Delay Curves
42, 44 & 46
(50 Amps Max.)
22x
10x
Multiple of
Rated Current
5.0
r
I
CURRENT
(AMPS)
0.10 - 5.0
5.1 - 20.0
15%
25%
TOLERANCE
(%)
20.1 - 100.0 35%
Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz
(see Table A.)
UL489: AC,240 VAC. (See Table D),
50/60 Hz, 125 VDC
Current Rating Standard current coils: 0.100,
0.250, 0.500, 0.750, 1.00, 2.50,
5.00, 7.50, 10.0, 15.0, 25.0, 30.0,
35.0, 40.0, 50.0, 60.0, 70.0, 80.0,
90.0 and 100 amps. Other ratings
available, see Ordering Scheme.
Standard Voltage Coils DC - 6V, 12V; AC - 120V; other
ratings available, see Ordering
Scheme.
Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux.
Switch 1.0A, 65 VDC. 0.5A,
80VDC,1/4 HP, 125VAC,VDE & TUV
1.0 125 VAC.
Insulation Resistance Minimum of 100 Megohms at 500
VDC.
Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one
minute between all electrically
isolated terminals. C-Series Circuit
Breakers comply with the 8mm
spacing and 3750V 50/60 Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces, between
adjacent poles and from main
circuits to auxiliary circuits per
Publications EN 60950 and
VDE 0805.
Resistance, Impedance Values from Line to Load Terminal -
based on Series Trip Circuit
Breaker.
Endurance 10,000 ON-OFF operations @ 6 per
minute; with rated current &
voltage.
Trip Free All C-Series circuit breakers will trip
on overload, even when actuator is
forcibly held in the ON position.
Trip Indication The operating actuator moves
positively to the OFF position when
an overload causes the breaker to
trip. With mid-trip, handle moves to
the mid position on electrical trip of
the circuit breaker. With mid trip
handle with alarm switch, handle
moves to the mid position and the
alarm switch actuates when the
circuit breaker is electrically
tripped.
Number of Poles 1-6 poles ≤ 50A; 1-4 poles @ 51-
70A; 1-2 poles 71-100A. UL489
Handle: 1 pole ≤ 100A, 2 pole ≤
50A; Rocker: 1 pole ≤ 100A.
Internal Circuit Cong. Series (with or without auxiliary
switch, mid trip & mid trip with
alarm switch) Shunt & Relay with
current or voltage trip coils, Dual
Coil, Switch Only (with or without
aux. switch). UL489: Series (with or
without auxiliary switch, mid-trip &
midtrip with alarm switch).
Weight Approx.112 grams/pole ( 3.95 oz).
Standard Colors Housing: Black
Designed and tested in accordance with requirements of
specication MIL-PRF-55629 & MIL-STD-202 as follows:
Shock Withstands 100 Gs, 6ms sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultrashort curves
tested @ 90% of rated current.
Vibration Withstands 0.060” excursion from
10-55 Hz & 10 Gs 55-500 Hz, @
rated current per Method 204C,
Test Cond. A. Instantaneous &
ultrashort curves tested @ 90% of
rated current.
Moisture Resistance Method 106D, i.e., ten 24-hour
cycles @ +25°C to +65°C,
80-98% RH.
Salt Spray Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock Method 107D, Condition A (ve
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature -40°C to +85°C
Pulse Tolerance Curves
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
6 |C-Series - Agency Certications
Agency Certications:
UL Recognized
UL Standard 1077 Component Recognition Program
as Protectors, Supplementary
(Guide CCN/QVNU2, File E75596)
UL Standard 508 Motor Controllers, Manual
(Guide CCN/NLRV2, File E135367)
UL Standard 1500 Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
UL Listed
UL Standard 489 Circuit Breakers, Molded Case,
(Guide DIVQ, File E129899)
UL Standard 489A Communications Equipment
(Guide CCN/DITT, File E189195)
CSA Accepted Component Supplementary Protector
under Class 3215 30,
File 047848 0 000
CSA Standard C22.2 No. 235
CSA Certied Circuit Breaker Model Case
(Class 1432 01, File 093910),
CSA Standard C22.2 No. 5.1 - M
TUV Certied EN60934, under License No.
R72041016
VDE Certied EN60934, VDE 0642 under File No.
10537
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 7
C-Series Handle UL Recognized – Ordering Scheme
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting
Bezel/Barrier
11
Agency
Approval
4
Circuit
C A B 1 13 0 2 C10 450
1 SERIES
C
2 ACTUATOR1
A Handle, one per pole
B Handle, one per multipole unit
S Mid-Trip Handle, one per pole
T Mid-Trip, one per pole & Alarm Switch
8 TERMINAL15
110 Stud 10-32
211 Screw 10-32
312 Stud 1/4-20
411 Stud M5 x 0.8
511 Screw M5 x 0.8
612 Stud M6
713,15 0.250 Double Click Connect
915 7/16” Clip Terminal
A14 Plug-In Stud
C11,15 5/16” Clip Terminal
3 POLES2
1 One
2 Two
3 Three
4 Four
5 Five
6 Six
4 CIRCUIT3
A3 Switch Only (no coil)
B Series Trip (current)
C Series Trip (voltage)
D4 Shunt Trip (current)
E4 Shunt Trip (voltage)
F4 Relay Trip (current)
G4 Relay Trip (voltage)
H4,5 Dual Coil with Shunt Trip
Voltage Coil
K4,5 Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY/ALARM SWITCH
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
033 DC 50/60Hz, Switch Only
107 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
207 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
428 50/60Hz Short, Hi-Inrush
448 50/60Hz Medium, Hi-Inrush
468 50/60Hz Long, Hi-Inrush
528 DC Short, Hi-Inrush
548 DC Medium, Hi-Inrush
56 DC Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
6609 60.000
6709 70.000
6809 80.000
6859 85.000
6909 90.000
6959 95.000
8109 100.000
CODE AMPERES
A06 6DC
A12 12DC
A18 18DC
A24 24DC
A32 32DC
A48 48DC
A65 65DC
J06 6AC
J12 12AC
J18 18AC
J24 24AC
J48 48AC
J65 65AC
K20 120AC
L40 240AC
CODE RATING
VOLTAGE COIL (NOMINAL RATED VOLTAGE)7
9 ACTUATOR COLOR & LEGEND16
Actuator Color I-O ON-OFF Dual Legend Color
White A B 1 Black
Black C D 2 White
Red F G 3 White
Green H J 4 White
Blue K L 5 White
Yellow M N 6 Black
Gray P Q 7 Black
Orange R S 8 Black
Black (short handle)17 T U 9 White
10 MOUNTING/BARRIERS
MOUNTING STYLE BARRIERS VOLTAGE
Threaded Insert
1 6-32 x 0.195 inches no < 300
A 6-32 X 0.195 inches yes < 300
C18 6-32X0.195inches yes ≥300
2 ISO M3 x 5mm no < 300
B ISO M3 x 5mm yes < 300
D18 ISOM3x5mm yes ≥300
Front panel Snap-In, 1.00” [25.4mm] wide bezel
E17 with Handleguard no < 300
11 AGENCY APPROVAL
C UL Recognized, CSA Accepted
D VDECertied,ULRecognized,CSAAccepted
E TUVCertied,ULRecognized,CSAAccepted
H UL489Construction:VDECertied,ULRecognized,CSAAccepted
I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), CSA Accepted
L UL489 Construction: UL Recognized, CSA Accepted
R UL489Construction:TUVCertied,ULRecognized,CSAAccepted
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles
5 pole - three handles at center poles 6 pole - four handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available
with circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip
of the breaker. Available with circuit codes B & C.
2 Standard multipole units have all poles identical except when specifying auxiliary
switch and/or mixed poles. 4 pole max w/VDE. 5th pole available as Series Trip w/
Voltage Coil only.
3 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE
Certicationwhentiedtoaprotectedpole(CircuitCodeB,C,DorH.).For.02to
30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.
4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit
Codes D, F, H & K available up to 50 amps maximum Current Rating.
5 Consult factory for available Dual Coil options, as special catalog number is
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip
instantaneously and are rated for intermittent duty only.
6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one aux. switch is supplied, mounted in the extreme right pole.
7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
8 Available with Circuit Codes B & D only, and up to 50 amps maximum.
9 Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100
are available up to two poles maximum.
10 Terminal Code 1 available to 60 amps maximum.
11 Terminal Codes 2, 4, 5 and C available to 50 amps maximum.
12 Terminal Codes 3, 6 & 9 available to 100 amps maximum.
13 Terminal Code 7 available to 25 amps maximum.
14 Terminal Code A available to 100 amps maximum.
15 Terminal Codes 7, 9 & C are not VDE approved.
16 No marking available. Consult factory. VDE/TUV Approval requires dual
(I-O, ON-OFF) or I-O markings on all handles.
17 Single pole only.
18 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only
and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or
to be used in applications with a motor.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
8 |C-Series Handle UL489A Listed / Parallel Pole – Ordering Scheme
9 ACTUATOR COLOR2
LEGEND
ON-OFF Dual Legend Color
White B 1 Black
Black D 2 White
Red G 3 White
Green J 4 White
Blue L 5 White
Yellow N 6 Black
Gray Q 7 Black
Orange S 8 Black
10 MOUNTING
Threaded Insert
1 6-32 x 0.195 inches
2 ISO M3 x 5mm
12 AGENCY APPROVAL8
A Without Approval
J UL489AListed,TUVCertied
T UL489A Listed
K UL489AListed,VDECertied(upto200amps)
7 UL489AListed,TUVCertied(upto250amps)
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting
11
Max. App.
Rating
12
Agency
Approval
4
Circuit
C A P 3 12 0 2 M TD4 820
1 SERIES
C
2 ACTUATOR1
A Handle, one per pole
S Mid-Trip Handle, one per pole
T Mid-Trip, one per pole & Alarm Switch
8 TERMINAL6
3 Stud 1/4-20
6 Stud M6
A Plug-In Stud
3 POLES4
1 One 2 Two 3 Three
4 CIRCUIT5
B Series Trip P Series Trip (parallel pole)
6 FREQUENCY & DELAY7
D1 DC Ultra Short
D2 DC Short
D4 DC Medium
D6 DC Long
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
7 CURRENT RATING (AMPERES)
810 100.00
811 110.00
812 120.00
912 125.00
813 130.00
814 140.00
815 150.00
816 160.00
817 170.00
917 175.00
818 180.00
819 190.00
820 200.00
9224 225.00
8254 250.00
CODE AMPERES
11 MAXIMUM APPLICATION RATING
M 80 DC
Notes:
1 Handle moves to Mid-Position only upon electrical trip of C/B when Actuator S is
specied.WhenActuatorCodeTisspecied,handlemovestoMidPositionand
Alarm Switch actuates only upon electrical trip of C/B.
2 Standard Handle colors are White, Black, Red & Yellow.
3 Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line
and Load Terminals. For Terminal Code A, Line and Load Terminals must be
connected to a copper bus bar having a minimum cross-section of 0.078 square
inches. Terminal code A not available on the single pole unit.
4 Rating for 101 to 125 amps are available in 1 pole size. Ratings from 110 to 200
amps are available in 2-pole size. For ratings from 225-250 amps, specify 3-pole size.
5 Circuit code B only available with 1 pole.
6 1 pole only available with terminal codes 3 and 6.
7 Delays 11, 12, 14, and 16 are only available with 1 pole.
8 Agency code K and 7 not available with 1 pole.
Agency code J only available with 1 pole.
5 AUXILIARY/ALARM SWITCH
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 9
C-Series Rocker UL489A Listed / Parallel Pole – Ordering Scheme
9 ACTUATOR COLOR
LEGEND
ON-OFF Dual Legend Color
White B 1 Black
Black D 2 White
Red G 3 White
Green J 4 White
Blue L 5 White
Yellow N 6 Black
Gray Q 7 Black
Orange S 8 Black
10 MOUNTING
ROCKER / MOUNTING INSERT STYLE
A Standard Rocker Bezel - 6-32 Inserts
B Standard Rocker Bezel - M3 Inserts
C Rocker Guard Bezel - 6-32 Inserts
D Rocker Guard Bezel - M3 Inserts
E Standard Bezel with recessed Off Side Flat Rocker - 6-32 Inserts
F Standard Bezel with recessed Off Side Flat Rocker - M3 Inserts
G Push to Reset Bezel - 6-32 Inserts
H Push to Reset Bezel - M3 Inserts
12 AGENCY APPROVAL6
A Without Approval
J UL489AListed,TUVCertied
T UL489A Listed
7 UL489AListed,TUVCertied
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting
11
Max. App.
Rating
12
Agency
Approval
4
Circuit
C 1 P 3 A2 0 1 M TD4 820
1 SERIES
C
2 ACTUATOR
C Curved Rocker, Two Color Visi, Indicate On, Vertical Legend
D Curved Rocker, Two Color Visi, Indicate On, Horizontal Legend
F Curved Rocker, Two Color Visi, Indicate Off, Vertical Legend
G Curved Rocker, Two Color Visi, Indicate Off, Horizontal Legend
J Curved Rocker, Single Color, Vertical Legend
K Curved Rocker, Single Color, Horizontal Legend
1 Flat Rocker, Two Color Visi, Vertical Legend
2 Flat Rocker, Two Color Visi, Horizontal Legend
3 Flat Rocker, Single Color, Vertical Legend
4 Flat Rocker, Single Color, Horizontal Legend
5 Flat Rocker, Push To Reset, Two Color Visi, Vertical Legend
6 Flat Rocker, Push To Reset, Two Color Visi, Horizontal Legend
7 Flat Rocker, Push To Reset, Single Color, Vertical Legend
8 Flat Rocker, Push To Reset, Single Color, Horizontal Legend
8 TERMINAL4
3 Stud 1/4-20
6 Stud M6
A Plug-In Stud
3 POLES2
1 One 2 Two 3 Three
4 CIRCUIT3
B Series Trip P Series Trip (parallel pole)
6 FREQUENCY & DELAY5
D1 DC Ultra Short
D2 DC Short
D4 DC Medium
D6 DC Long
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
7 CURRENT RATING (AMPERES)2
810 100.00
811 110.00
812 120.00
912 125.00
813 130.00
814 140.00
815 150.00
816 160.00
817 170.00
917 175.00
818 180.00
819 190.00
820 200.00
922 225.00
825 250.00
CODE AMPERES
11 MAXIMUM APPLICATION RATING
M 80 DC
Notes:
1 Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line
and Load Terminals. For Terminal Code A, Line and Load Terminals must be
connected to a copper bus bar having a minimum cross-section of 0.078 square
inches. Terminal code A not available on the single pole unit.
2 Ratings for 101 to 125 amps are availabe in 1-pole size. Ratings from 110 to 200
amps are available in 2-pole size. For ratings from 225-250 amps, specify 3-pole
size.
3 Circuit code B only available with 1-pole.
4 1 pole only available with terminal codes 3 and 6.
5 Delays 11, 12, 14, and 16 are only available with 1 pole.
6 Agency code K and 7 not available with 1 pole.
Agency code J only available with 1 pole.
5 AUXILIARY/ALARM SWITCH
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
10 |C-Series Handle UL489 Listed – Ordering Scheme
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
11
Max. App.
Rating
12
Agency
Approval
4
Circuit
C A B 1 13 0 2 K G14 450
1 SERIES
C
2 ACTUATOR1
A Handle, one per pole
B Handle, one per multipole unit
S Mid-Trip Handle, one per pole
T Mid-Trip, one per pole & Alarm Switch
8 TERMINAL6
17 Stud 10-32
28 Screw 10-32
39 Stud 1/4-20
48 Stud M5 x 0.8
58 Screw M5 x 0.8
69 Stud M6
99 7/16” Clip Terminal
A10 Plug-In Stud
C8 5/16” Clip Terminal
3 POLES2
1 One 2 Two 3 Three
4 CIRCUIT
B Series Trip (current)
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
424 50/60Hz Short, Hi-Inrush
444 50/60Hz Medium, Hi-Inrush
464 50/60Hz Long, Hi-Inrush
524 DC Short, Hi-Inrush
544 DC Medium, Hi-Inrush
564 DC Long, Hi-Inrush
7 CURRENT RATING (AMPERES)5
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
660 60.000
670 70.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.000
CODE AMPERES
11 MAXIMUM APPLICATION RATING
A 65 DC
B 125 DC
C 120/240 AC2
D 240 AC
K 120 AC
F 277 AC
M 80 DC
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units.
B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip
of the breaker.
2 Standard multipole units have all poles identical except when specifying auxiliary
switch and/or mixed poles.
2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating
code C) applications, have all poles identical except when specifying auxiliary /
alarmswitchwhichisnormallysuppliedinextremerightpolepergureB.Terminal
barriers are required on all multipole breakers.
Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd
pole has the same construction as poles 1 & 2.
3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme
right pole.
VDE approval on auxiliary switch codes 2, 3 & 4 only.
Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit,
only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC,
and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit
breaker, is supplied from factory with common terminal of auxiliary / alarm switch
connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated
120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common
terminal connected to breaker line terminal. Consult factory for special catalog
number.
4 Available up to 50 amps maximum.
5 Current ratings 71 - 100 with VDE approvals are available up to two poles
maximum.
6 Terminal Codes 9 & C are not VDE approved.
7 Terminal Code 1 available to 60 amps maximum.
8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum.
9 Terminal Codes 3, 6 & 9 available to 100 amps maximum.
10 Terminal Code A available to 100 amps maximum.
11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles.
12 Barriers supplied on multi-pole units only.
9 ACTUATOR COLOR & LEGEND11
Actuator Color ON-OFF Dual Legend Color
White B 1 Black
Black D 2 White
Red G 3 White
Green J 4 White
Blue L 5 White
Yellow N 6 Black
Gray Q 7 Black
Orange S 8 Black
10 MOUNTING/BARRIERS
MOUNTING STYLE BARRIERS12
Threaded Insert
1 6-32 x 0.195 inches yes
2 ISO M3 x 5mm yes
12 AGENCY APPROVAL11
A w/o approvals
F UL489Listed,CSACertied&VDECertied
G UL489Listed&CSACertied
J UL489Listed,CSACertied&TUVCertied
5 AUXILIARY/ALARM SWITCH3
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 11
C-Series Sealed Toggle UL Recognized – Ordering Scheme
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Legend
Plate
10
Mounting
Bezel/Barrier
11
Agency
Approval
4
Circuit
C M B 1 13 0 0 C10 450
1 SERIES
C
2 ACTUATOR1
M Sealed Toggle, one per pole
8 TERMINAL
19 Stud 10-32
210 Screw 10-32
311 Stud 1/4-20
410 Stud M5 x 0.8
510 Screw M5 x 0.8
611 Stud M6
712 0.250 Double Click Connect
911 7/16” Clip Terminal
A13 Plug-In Stud
C10 5/16” Clip Terminal
3 POLES
1 One 2 Two 3 Three
4 CIRCUIT
A2 Switch Only (no coil)
B Series Trip (current)
C Series Trip (voltage)
D3 Shunt Trip (current)
E3 Shunt Trip (voltage)
F3 Relay Trip (current)
G3 Relay Trip (voltage)
H3,4 Dual Coil with Shunt Trip
Voltage Coil
K3,4 Dual Coil with Relay Trip
Voltage Coil
6 FREQUENCY & DELAY
032 DC 50/60Hz, Switch Only
106 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
206 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
427 50/60Hz Short, Hi-Inrush
447 50/60Hz Medium, Hi-Inrush
467 50/60Hz Long, Hi-Inrush
527 DC Short, Hi-Inrush
547 DC Medium, Hi-Inrush
56 DC Long, Hi-Inrush
7 CURRENT RATING (AMPERES)9
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
6609 60.000
6709 70.000
6809 80.000
6859 85.000
6909 90.000
6959 95.000
8109 100.000
CODE AMPERES
A06 6DC
A12 12DC
A18 18DC
A24 24DC
A32 32DC
A48 48DC
A65 65DC
J06 6AC
J12 12AC
J18 18AC
J24 24AC
J48 48AC
J65 65AC
K20 120AC
L40 240AC
CODE RATING
VOLTAGE COIL (NOMINAL RATED VOLTAGE)7
9 LEGEND PLATE
0 No Legend
Notes:
1 Actuator Code M: Handle location as viewed from front of breaker:
2 pole - right pole 3 pole - center pole
2 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE.
For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current
Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select
Current Code 810.
3 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only.
4 Consult factory for available Dual Coil options, as special catalog number is
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip
instantaneously and are rated for intermittent duty only.
5 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one aux. switch is supplied, mounted in the extreme right pole.
6 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
7 Available with Circuit Codes B & D only, and up to 50 amps maximum.
8 Consult factory for current ratings 71-100, in three pole units, available as special
catalog number only.
9 Terminal Code 1 available to 60 amps maximum.
10 Terminal Codes 2, 4, 5 and C available to 50 amps maximum.
11 Terminal Codes 3, 6 & 9 available to 100 amps maximum.
12 Terminal Code 7 available to 25 amps maximum.
13 Terminal Code A available to 100 amps maximum.
10 MOUNTING/BARRIERS
MOUNTING STYLE BARRIERS
1 Standard Hex Nut no
A Standard Hex Nut (multi-pole units only) yes
11 AGENCY APPROVAL
C UL Recognized & CSA Accepted
L UL Recognized & CSA Accepted with listed construction
T UL Recognized & CSA Accepted, UL1500 ignition protection
5 AUXILIARY/ALARM SWITCH
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
12 |C-Series Rocker UL Recognized – Ordering Scheme
2 ACTUATOR1
Two Color Visi-Rocker
C Indicate ON, vertical legend
D Indicate ON, horizontal legend
E Indicate ON, no legend
F Indicate OFF, vertical legend
G Indicate OFF, horizontal legend
H Indicate OFF, no legend
Push-To-Reset, Visi-Rocker
N Indicate OFF,
vertical legend
O Indicate OFF,
horizontal legend
P Indicate OFF,
no legend
Single color
J Vertical legend
K Horizontal legend
L No legend
Push-To-Reset, Single color
R Vertical legend
U Horizontal legend
V No legend
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
11
Agency
Approval
4
Circuit
C C B 1 13 0 2 D
14 450
1 SERIES
C
8 TERMINAL
110 Stud 10-32
211 Screw 10-32
312 Stud 1/4-20
411 Stud M5 x 0.8
511 Screw M5 x 0.8
612 Stud M6
713 0.250 Double Quick Connect
9 7/16” Clip Terminal
A14 Plug-In Stud
C 5/16” Clip Terminal
3 POLES2
1 One 2 Two 3 Three
4 CIRCUIT
A3 Switch Only (No Coil)
B Series Trip (Current)
C Series Trip (Voltage)
D4 Shunt Trip (Current)
E4 Shunt Trip (Voltage)
F4 Relay Trip (Current)
G4 Relay Trip (Voltage)
H4,5 Dual Coil with Shunt Trip
Voltage Coil
K4,5 Dual Coil with Relay Trip
Voltage Coil
9 ACTUATOR COLOR & LEGEND16,17,18
Single Color
Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker
White A B 1 Black White
Black C D 2 White n/a
Red F G 3 White Red
Green H J 4 White Green
Blue K L 5 White Blue
Yellow M N 6 Black Yellow
Gray P Q 7 Black Gray
Orange R S 8 Black Orange
Actuator or
Visi-Color Marking: Marking Color:
7 CURRENT RATING (AMPERES)
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
6609 60.000
6709 70.000
6809 80.000
6859 85.000
6909 90.000
6959 95.000
8109 100.000
CODE AMPERES
A06 6DC
A12 12DC
A18 18DC
A24 24DC
A32 32DC
A48 48DC
A65 65DC
J06 6AC
J12 12AC
J18 18AC
J24 24AC
J48 48AC
J65 65AC
K20 120AC
L40 240AC
CODE RATING
VOLTAGE COIL (NOMINAL RATED VOLTAGE)7
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
107 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
207 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
428 50/60Hz Short, Hi-Inrush
448 50/60Hz Medium, Hi-Inrush
468 50/60Hz Long, Hi-Inrush
528 DC Short, Hi-Inrush
548 DC Medium, Hi-Inrush
568 DC Long, Hi-Inrush
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all poles identical except when specifying Aux. switch and/
or mixed poles, and have one rocker per breaker. Rocker location as viewed from
front panel: 2 pole – left pole; 3 pole – center pole.
3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE
Certicationwhentiedtoaprotectedpole(CircuitCodeB,C,DorH.),For.02to
30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.
4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit
Codes D,F,H & K available up to 50 amps maximum Current Rating.
5 Consult factory for available Dual Coil options, as special catalog number is
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip
instantaneously and are rated for intermittent duty only.
6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one aux. switch is supplied, mounted in the extreme right pole. Auxiliary
switch codes 2, 3 & 4 are VDE approved.
7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
8 Available with Circuit Codes B & D only, and up to 50 amps maximum.
9 Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are
available up to two poles maximum.
10 Terminal Code 1 available to 60 amps maximum.
11 Terminal Codes 2,4,5 & C available to 50 amps maximum.
12 Terminal Codes 3,6 & 9 available to 100 amps maximum.
13 Terminal Code 7 available to 25 amps maximum.
14 Terminal Code A available to 100 amps maximum.
15 Terminal Codes 7, 9 & C are not VDE approved.
16 Color shown is visi and legend with remainder of rocker black
17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered.
Dual = ON-OFF/I-O legend with actuator codes C - G, and J, K, N, O, R, & U. None
= no legend with actuator codes H, L, P, V. Rockerguard available with actuator
codes C - L. Push-to-reset available with actuator codes N, O, P, R, U, V.
18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker.
19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only
and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or
to be used in applications with a motor.
10 MOUNTING/BARRIERS1
STANDARD ROCKER BEZEL BARRIERS VOLTAGE
1 6-32 x 0.195 inches no <300
2 6-32 x 0.195 inches yes <300
319 6-32x0.195inches yes ≥300
4 ISO M3 x 5mm no <300
5 ISO M3 x 5mm yes <300
619 ISOM3x5mm yes ≥300
ROCKERGUARD BEZEL
A 6-32 x 0.195 inches no <300
C 6-32 x 0.195 inches yes <300
E19 6-32x0.195inches yes ≥300
G ISO M3 x 5mm no <300
J ISO M3 x 5mm yes <300
L19 ISOM3x5mm yes ≥300
PUSH-TO-RESET BEZEL
B 6-32 x 0.195 inches no <300
D 6-32 x 0.195 inches yes <300
F19 6-32x0.195inches yes ≥300
H ISO M3 x 5mm no <300
J ISO M3 x 5mm yes <300
M19 ISOM3x5mm yes ≥300
11 AGENCY APPROVAL
C UL Recognized & CSA Accepted
D VDECertied,ULRecognized&CSAAccepted
E TUVCertied,ULRecognized&CSAAccepted
H UL489Construction:VDECertied,ULRecognized&CSAAccepted
I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
L UL489 Construction: UL Recognized & CSA Accepted
R UL489Construction:TUVCertied,ULRecognized&CSAAccepted
5 AUXILIARY/ALARM SWITCH6
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 13
C-Series Rocker UL Listed – Ordering Scheme
2 ACTUATOR1
Two Color Visi-Rocker
C Indicate ON, vertical legend
D Indicate ON, horizontal legend
F Indicate OFF, vertical legend
G Indicate OFF, horizontal legend
Single color
J Vertical legend
K Horizontal legend
9 ACTUATOR COLOR & LEGEND11
Single Color
Color: ON-OFF Dual10 Rocker/Handle Visi-Rocker
White B 1 Black White
Black D 2 White n/a
Red G 3 White Red
Green J 4 White Green
Blue L 5 White Blue
Yellow N 6 Black Yellow
Gray Q 7 Black Gray
Orange S 8 Black Orange
Actuator or
Visi-Color Marking: Marking Color:
SINGLE COLOR
CODE "J"
LINE
CODE "K"
LINE
INDICATE "ON"
CODE "C"
LINE
LINELINE
LINE
CODE "D"
INDICATE
COLOR
LOCATION
HORIZONTAL
STYLE
VERTICAL
STYLE
CODE "G"
CODE "F"
ROCKER STYLE DESCRIPTIONS
INDICATE "OFF"
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
11
Max. App.
Rating
12
Agency
Approval
4
Circuit
C C B 1 A3 0 2 K G14 450
1 SERIES
C
8 TERMINAL
15 Stud 10-32
26 Screw 10-32 w/saddle &
washer clamps
37 Stud 1/4-20
46 Stud M5 x 0.8
56 Screw M5 x 0.8 w/saddle &
washer clamps
67 Stud M6
97,8 7/16” Clip Terminal
A7,8 Plug-In Stud
C6,8 5/16” Clip Terminal
3 POLES1
1 One 2 Two 3 Three
4 CIRCUIT
B Series Trip (current)
7 CURRENT RATING (AMPERES)4
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
660 60.000
670 70.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.000
CODE AMPERES
11 MAXIMUM APPLICATION RATING
A 65 DC
B 125 DC
C 120/240 AC14
D 240 AC
F 277 AC
K 120 AC
M 80 DC
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
428 50/60Hz Short, Hi-Inrush
448 50/60Hz Medium, Hi-Inrush
468 50/60Hz Long, Hi-Inrush
528 DC Short, Hi-Inrush
548 DC Medium, Hi-Inrush
56 DC Long, Hi-Inrush
Notes:
1 Multi-pole breakers have all breakers identical except when specifying Aux. switch
and/or mixed poles, and have one rocker per breaker.
2 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right
pole.
3 Available up to 50 amps maximum.
4 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum.
5 Terminal Code 1 available to 60 amps maximum.
6 Terminal Codes 2, 4, 5 & C available to 50 amps maximum.
7 Terminal Codes 3, 6, 9 & A available to 100 amps maximum.
8 Terminal Codes 9 & C are not VDE approved.
9 Color shown is visi and legend with remainder of rocker black
10 Dual = ON-OFF/I-O legend on actuator.
11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker.
12 Rockerguard available with all actuator codes.
13 Barriers supplied on multi-pole units only.
14 2 & 3 pole circuit breakers required for 120/240 AC rating.
10 MOUNTING/BARRIERS12
Standard Rocker Bezel BARRIERS13
Threaded Insert, 2 per pole
A 6-32 X 0.195 inches yes
C ISO M3 x 5mm yes
Rockerguard Bezel
Threaded Insert, 2 per pole
B 6-32 x 0.195 inches yes
D ISO M3 x 5mm yes
12 AGENCY APPROVAL
A without approvals
F UL489Listed,CSACertied,&VDECertied
G UL489Listed&CSACertied
J UL489Listed,CSACertied&TUVCertied
5 AUXILIARY/ALARM SWITCH2
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
14 |C-Series Flat Rocker UL Recognized – Ordering Scheme
2 ACTUATOR1
Two Color Visi-Rocker
1 Indicate OFF, vertical legend
2 Indicate OFF, horizontal legend
Single color
3 Vertical legend
4 Horizontal legend
Push-To-Reset, Visi-Rocker
5 Indicate OFF, vertical legend
6 Indicate OFF, horizontal legend
Push-To-Reset , Single color
7 Vertical legend
8 Horizontal legend
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
11
Agency
Approval
4
Circuit
C 1 B 1 12 0 2 E10 450
1 SERIES
C
8 TERMINAL
110 Stud 10-32
211 Screw 10-32
312 Stud 1/4-20
411 Stud M5 x 0.8
511 Screw M5 x 0.8
612 Stud M6
713 0.250 Double Quick Connect
915 7/16” Clip Terminal
A14 Plug-In Stud
C15 5/16” Clip Terminal
3 POLES2
1 One 2 Two 3 Three
4 CIRCUIT
A3 Switch Only (No Coil)
B Series Trip (Current)
C Series Trip (Voltage)
D4 Shunt Trip (Current)
E4 Shunt Trip (Voltage)
F4 Relay Trip (Current)
G4 Relay Trip (Voltage)
H4,5 Dual Coil with Shunt Trip
Voltage Coil
K4,5 Dual Coil with Relay Trip
Voltage Coil
7 CURRENT RATING (AMPERES)9
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
6609 60.000
6709 70.000
6809 80.000
6859 85.000
6909 90.000
6959 95.000
8109 100.000
CODE AMPERES
A06 6DC
A12 12DC
A18 18DC
A24 24DC
A32 32DC
A48 48DC
A65 65DC
J06 6AC
J12 12AC
J18 18AC
J24 24AC
J48 48AC
J65 65AC
K20 120AC
L40 240AC
CODE RATING
VOLTAGE COIL (NOMINAL RATED VOLTAGE)7
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
107 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
207 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
428 50/60Hz Short, Hi-Inrush
448 50/60Hz Medium, Hi-Inrush
468 50/60Hz Long, Hi-Inrush
528 DC Short, Hi-Inrush
548 DC Medium, Hi-Inrush
568 DC Long, Hi-Inrush
Notes:
1 Push-to-reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all poles identical except when specifying Aux. switch and/or
mixed poles, and have one rocker per breaker. Rocker location as viewed from front
panel: 2 pole – left pole; 3 pole – center pole.
3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE
Certicationwhentiedtoaprotectedpole(CircuitCodeB,C,DorH.).For.02to30
amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For
55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.
4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit
Codes D,F,H & K available up to 50 amps maximum Current Rating.
5 Consult factory for available Dual Coil options, as special catalog number is required.
Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line
voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously
and are rated for intermittent duty only.
6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one aux. switch is supplied, mounted in the extreme right pole. Auxilary
switch codes 2, 3 & 4 are VDE approved.
7 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
8 Available with Circuit Codes B & D only, and up to 50 amps maximum.
9 Current ratings 60-70 are available up to four poles maximum. Current ratings 71 -
100 are available up to two poles maximum.
10 Terminal Code 1 available to 60 amps maximum.
11 Terminal Codes 2,4,5 & C available to 50 amps maximum.
12 Terminal Codes 3,6 & 9 available to 100 amps maximum.
13 Terminal Code 7 available to 25 amps maximum.
14 Terminal Code A available to 100 amps maximum.
15 Terminal Codes 7, 9 & C are not VDE approved.
16 Color shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O
legend.
17 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 &
8. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator
codes 5 & 6.
18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker.
19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 & 3 poles only and
limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be
used in applications with a motor.
20 Recessed “OFF SIDE” available with actuator codes 1,2,3&4. Legends on rocker are
available in ink stamping only.
9 ACTUATOR COLOR & LEGEND16,17,18
Single Color
Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker
White A B 1 Black White
Black C D 2 White n/a
Red F G 3 White Red
Green H J 4 White Green
Blue K L 5 White Blue
Yellow M N 6 Black Yellow
Gray P Q 7 Black Gray
Orange R S 8 Black Orange
Actuator or
Visi-Color Marking: Marking Color:
10 MOUNTING/BARRIERS1
STANDARD ROCKER BEZEL BARRIERS VOLTAGE
1 6-32 x 0.195 inches no <300
2 6-32 x 0.195 inches yes <300
319 6-32x0.195inches yes ≥300
4 ISO M3 x 5mm no <300
5 ISO M3 x 5mm yes <300
619 ISOM3x5mm yes ≥300
RECESSED OFF ROCKER
7 6-32 x 0.195 inches no <300
8 6-32 x 0.195 inches yes <300
9 6-32x0.195inches yes ≥300
A ISO M3 x 5mm no <300
C ISO M3 x 5mm yes <300
E ISOM3x5mm yes ≥300
PUSH-TO-RESET BEZEL
B 6-32 x 0.195 inches no <300
D 6-32 x 0.195 inches yes <300
F19 6-32x0.195inches yes ≥300
H ISO M3 x 5mm no <300
J ISO M3 x 5mm yes <300
M19 ISOM3x5mm yes ≥300
11 AGENCY APPROVAL
C UL Recognized & CSA Accepted
E TUVCertied,ULRecognized&CSAAccepted
I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
L UL489 Construction: UL Recognized & CSA Accepted
R UL489Construction:TUVCertied,ULRecognized&CSAAccepted
5 AUXILIARY/ALARM SWITCH6
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 15
C-Series Flat Rocker UL Listed – Ordering Scheme
2 ACTUATOR1
Two Color Visi-Rocker
1 Indicate OFF, vertical legend
2 Indicate OFF, horizontal legend
Single color
3 Vertical legend
4 Horizontal legend
Push-To-Reset, Visi-Rocker
5 Indicate OFF, vertical legend
6 Indicate OFF, horizontal legend
Push-To-Reset , Single color
7 Vertical legend
8 Horizontal legend
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
11
Max. App.
Rating
12
Agency
Approval
4
Circuit
C 1 B 1 A2 0 2 K G14 450
1 SERIES
C
8 TERMINAL
17 Stud 10-32
28 Screw 10-32
39 Stud 1/4-20
48 Stud M5 x 0.8
58 Screw M5 x 0.8
69 Stud M6
99,10 7/16” Clip Terminal
A9 Plug-In Stud
C8,10 5/16” Clip Terminal
3 POLES2
1 One 2 Two 3 Three
4 CIRCUIT
B Series Trip (current)
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
424 50/60Hz Short, Hi-Inrush
444 50/60Hz Medium, Hi-Inrush
464 50/60Hz Long, Hi-Inrush
524 DC Short, Hi-Inrush
544 DC Medium, Hi-Inrush
564 DC Long, Hi-Inrush
7 CURRENT RATING (AMPERES)5
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
660 60.000
670 70.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.000
CODE AMPERES
11 MAXIMUM APPLICATION RATING
A 65 DC
B 125 DC
C 120/240 AC16
D 240 AC
F 277 AC
K 120 AC
M 80 DC
1 Notes:
2 Push-to-reset actuators have OFF portion of rocker shrouded.
3 Multi-pole breakers have all breakers identical except when specifying Aux. switch
and/or mixed poles, and have one rocker per breaker.
4 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right
pole.
5 Available up to 50 amps maximum.
6 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum.
7 Terminal Code 1 available to 60 amps maximum.
8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum.
9 Terminal Codes 3, 6, 9 & A available to 100 amps maximum.
10 Terminal Codes 9 & C are not VDE approved.
11 Color shown is visi and legend with remainder of rocker black
12 Dual = ON-OFF/I-O legend on actuator.
13 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker.
14 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered.
Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator
codes
15 5 & 6.
16 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker
are available in ink stamping only.
17 Barriers supplied on multi-pole units only.
18 2 & 3 pole circuit breakers required for 120/240 AC rating.
9 ACTUATOR COLOR & LEGEND12
Single Color
Color: ON-OFF Dual11 Rocker/Handle Visi-Rocker
White B 1 Black White
Black D 2 White n/a
Red G 3 White Red
Green J 4 White Green
Blue L 5 White Blue
Yellow N 6 Black Yellow
Gray Q 7 Black Gray
Orange S 8 Black Orange
Actuator or
Visi-Color Marking: Marking Color:
10 MOUNTING/BARRIERS12
STANDARD ROCKER BEZEL BARRIERS15
Threaded Insert, 2 per pole
A 6-32 X 0.195 inches yes
C ISO M3 x 5mm yes
RECESSED OFF ROCKER14
Threaded Insert, 2 per pole
E 6-32 x 0.195 inches yes
F ISO M3 x 5mm yes
PUSH-TO-RESET BEZEL13
Threaded Insert, 2 per pole
B 6-32 x 0.195 inches yes
D ISO M3 x 5mm yes
12 AGENCY APPROVAL
A without approvals
G UL489Listed&CSACertied
J UL489Listed,CSACertied&TUVCertied
5 AUXILIARY/ALARM SWITCH2
0 without Aux Switch
2 S.P.D.T., 0.110 Q.C. Term.
3 S.P.D.T., 0.139 Solder Lug
4 S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6 S.P.S.T., 0.139 Solder Lug
8 S.P.S.T., 0.187 Q.C. Term.
9 S.P.D.T., 0.187 Q.C. Term.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
.558 [14.17]
.960 [24.38]
.311 DIA [Ø7.90]
16 | C-Series Handle – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance±.020[.51]unlessotherwisespecied.
3 Available on Series Trip and Switch Only Circuits when called for on multi-pole units.
Onlyoneaux.switchisnormallysupplied,asviewedinmulit-poleidenticationscheme.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 17
C-Series Handle – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance±.020[.51]unlessotherwisespecied.
3 Schematic shown represents current trip circuits.
4 Available only as special catalog number.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
18 |C-Series Handle – Form & Fit Drawings
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance±.020[.51]unlessotherwisespecied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 19
C-Series Handleguard – Form & Fit Drawings
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance±.020[.51]unlessotherwisespecied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
20 |C-Series Arc Chute Barrier UL Recognized/Listed – Form & Fit Drawings
Notes:
1 Only1-poleand3-polecongurationsshown.Arcchute(w/obarrier)andarcchute
barrier also available for 2-pole construction.
2 Dimensions apply to all variations shown.
3 Notice that line and load terminal orientation for indicate on and indicate off rocker
circuit breakers are opposite.
4 Screw type terminals shown for Rocker style (CF1, C11, etc) circuit breakers. For
otherterminalcongurationsseecircuitandterminaldiagrams.
5 All dimensions are in inches [millimeters].
6 Tolerance±.020unlessotherwisespecied.
7 Must be ordered under a special catalog number.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 21
C-Series Parallel Pole – Form & Fit Drawings
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance±.020[.51]unlessotherwisespecied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
22 |C-Series Sealed Toggle – Form & Fit Drawings
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance±.020[.51]unlessotherwisespecied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 23
C-Series Rocker – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance±.020[.51]unlessotherwisespecied.
3 Schematic shown represents current trip circuit.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
24 |C-Series Rocker – Form & Fit Drawings
Notes:
1 Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON.
2 For pole orientation with horizontal legend, rotate front view clockwise 90°.
3 All dimensions are in inches [millimeters].
4 Tolerance±.020[.51]unlessotherwisespecied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 25
C-Series Flat Rocker – Form & Fit Drawings
Notes:
1 For pole orientation with horizontal legend, rotate front view clockwise 90°.
2 All dimensions are in inches [millimeters].
3 Tolerance±.020[.51]unlessotherwisespecied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
26 |Reps & Contact
TX
NM
AZ
CA
NV
UT CO
WY
MT
ID
WA
OR
OK
AR
LA
MS AL GA
FL
TN NC
VA
SC
DE
NJ
CT
MA
VT
NH
ME
NY
OH
WV
KY
IN
IL
MO
KS
NE
SD
MN WI
MI
ND
IA PA RI
MD
TEMCO Northwest
Hanna Lind Ltd.
Sierra LD. Allen Norris
Pacent
TSI North
TSI
DM Assoc
East
Dy-tronix Inc.
Sunbelt Components
Pinnacle Marketing
Omega Limited
Bridge Marketing
Alaska, Hawaii
Matera
W. Canada
Luscombe
Engineering
Signal
Enterprises
Matera
E. Canada
DM
Michigan
DM Mexico
Mexico
Matrix
South America
DM
Assoc
Melody
Emery
ProRep
Solutions
Authorized Sales Representatives
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales oces worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-prole.
To view all of Carling’s environmental, quality, health & safety certications please visit
www.carlingtech.com/environmental-certications
Click on the group name on the map below to nd your local representative or visit
www.carlingtech.com/ndarep.
Americas
Europe
Middle East
Africa
Asia-Pacic
Oceania
«
«
«
«
«
MIDWEST
NORTHERN
SOUTHEAST
LATIN AMERICA
WEST
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 27
Notes
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
Email: sales@carlingtech.com
Northern Region Sales Oce: nrsm@carlingtech.com
Southeast Region Sales Oce: sersm@carlingtech.com
Midwest Region Sales Oce: mrsm@carlingtech.com
West Region Sales Oce: wrsm@carlingtech.com
Latin America Sales Oce: larsm@carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacic Ltd.,
Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
Email: sales@carlingtech.com.hk
Shenzhen, China: shenzhen@carlingtech.com
Shanghai, China: shanghai@carlingtech.com
Pune, India: india@carlingtech.com
Kaohsiung, Taiwan: taiwan@carlingtech.com
Yokohama, Japan: japan@carlingtech.com
Europe | Middle East | Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
Email: ltd.sales@carlingtech.com
Germany: gmbh@carlingtech.com
France: sas@carlingtech.com
www.carlingtech.com REV_08_2015