Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
32 DC --- 0.02 - 100 --- --- 5000 TC1, OL1, U2 TC1, OL1, U2
48 DC --- 110 - 150 --- --- 5000 TC1, OL1, U2 TC1, OL1, U2
65 DC --- 0.02 - 70 --- --- 5000 TC1,2, OL1,U1 TC1,2, OL1,U1
--- 71 -100 --- 5000 TC1,2, OL0,U1 TC1,2, OL0,U1
0.02 - 70 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1
--- 71 -100 --- 7500 TC1,2, OL0,U1 TC1,2, OL0,U1
0.02 - 70 --- --- 10,000 TC1,2, OL1,U1 TC1,2, OL1,U1 Must Have Agency Code "L"
--- 71 -100 --- 10,000 TC1,2, OL0,U1 TC1,2, OL0,U1 Must Have Agency Code "L"
125 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L"
125 / 250 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L"
250 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L". 2 Pole Break Required for 250 Volts
0.02 - 100 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating
0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L"
150 DC --- --- 80 - 100 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L"
150 DC --- --- 101 - 175 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L" Parallel Pole
0.02 - 100 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2
0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase
51 - 100 --- --- 1000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase
0.02 - 100 --- --- 5000 TC1,2,OL1,U2 TC1,2,OL1,U2 2 or 3 poles breaking single phase, "L" Agency Code
0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating
0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L"
51 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
--- 0.02 - 100 --- 3000 TC1, OL0, U2 TC1, OL0, U2
0.02 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
--- 0.02 - 90 --- 5000 TC1,2,OL0,U1 TC1,2,OL0,U1 Must Have Agency Code "L"
277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
--- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1
0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 2 poles breaking 1 phase
--- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1
80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1
125 50 / 60 1 0.02 - 50 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating
0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 2 or 3 poles breaking single phase
0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase
1 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2
0.02 - 50 --- --- 3000 TC1, OL0, U2 TC1, OL0, U2 Per Pole Rating
0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1
277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
--- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1
0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 2 poles breaking 1 phase
--- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1
80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1
277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1
250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase
0.02 - 70 --- --- --- --- ---
--- 71 -100 --- --- --- ---
0.02 - 70 --- --- --- --- ---
--- 71 -100 --- --- --- ---
125 50 / 60 1 0.02 - 100 --- --- --- --- ---
125 / 250 50 / 60 1 0.02 - 100 --- --- --- --- --- 2 or 3 poles breaking single phase
1 0.02 - 100 --- --- --- --- ---
3 0.02 - 70 --- --- --- --- ---
277 50 / 60 1 0.02 - 50 --- --- --- --- ---
0.02 - 30 --- --- --- --- --- 3 poles breaking 3 phase
--- 31 - 50 --- --- --- ---
125 / 250 50 / 60 1
DUAL COIL
C-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS
FULL LOAD
AMPS
SERIES
CIRCUIT
CONFIGURATION MAX.
RATING FREQUENCY
50 / 60
250 50 / 60
1
3
480 50 / 60 1
480 / 277 50 / 60
125 / 250
1
3
3
480 50 / 60 1
480 / 277 50 / 60
3
GENERAL
PURPOSE AMPS
DC
VOLTAGE
---80
80 DC
SHORT CIRCUIT CAPACITY (AMPS)
WITHOUT BACKUP
FUSE
WITH BACKUP
FUSE 1
SWITCH ONLY
480 / 277 50 / 60
250 50 / 60
DC
CURRENT RATING
RELAY
SHUNT
3
65 DC
80
250 50 / 60
---
---
125 50 / 60 1
NOTES
UL CSA
APPLICATION CODES
---
PHASE
UL/CSA
2 |C-Series – General Specications
Electrical Tables
Table A: Lists UL Recognized & CSA Accepted congurations and performance capabilities as a Component Supplementary
Protector
Notes for Table A:
1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and
not to exceed 175 for 51 through 100 Amp rating
*Manufacturer reserves the right to change product specification without prior notice.