DEVELOPMENT KIT (Info Click here) DM1810916MR * Network Router * Compatible with RFM miniMESHTM Network Protocol * 3 V, Very Low Current Operation * Ready-to-Use OEM Module The DM1810-916MR is the 916.5 MHz router module in the DM1810 family of RF transceivers. The DM1810 family is designed for adding wireless mesh connectivity to a wide range of monitoring and control systems. This module is compatible with RFM miniMESHTM network protocol, which provides "plug-and-play" multicast mesh network routing. Radio communications range in an "open field" environment is typically 600 meters/hop. The DM1810-916MR combines RFM's very low current ASH radio technology with low power microcontroller technology to achieve long battery life. The DM1810-916MR is certified for operation under FCC 15.247 and Canadian RSS 210 regulations. 916.50 MHz Transceiver Module Absolute Maximum Ratings Rating Value All Input/Output Pins Except VIN -0.3 to +3.3 Non-Operating Ambient Temperature Range -40 to 85 Units V o C Electrical Characteristics Characteristic Sym Operating Frequency fO Modulation Type Notes Minimum Typical 916.30 Maximum Units 916.70 MHz OOK on BPSK Spreading Code RF Encoded Data Transmission Rate Average Receive Input Current, No External Power Supply Load IR -3 Receiver Input Signal for 10 BER, 25 C Average Transmit Input Current, No External Power Supply Load ITA Peak Transmit Input Current, No External Power Supply Load ITP Peak Transmitter Output Power PO Bind Input Logic High 4.8 kb/s 5.5 mA -100 dBm 15.75 mA 32 10 mW 2.4 V Bind Input Logic Low 0.45 Average Sleep Input Current, No External Power Supply Load ISA mA 60 V A o VIN 3.1 10 V Power Supply Input Voltage Range, 0 to +85 C VIN 2.6 10 V Power Supply Input Voltage Range, -40 to +85 C o Regulated Power Supply Output Voltage, VIN 3.1 to 10 V VOUT 3.0 Regulated Power Supply Voltage Ripple Relative Humidity Range, Non-Condensing www.RFM.com E-mail: info@rfm.com (c)2008 by RF Monolithics, Inc. RH 10 Vdc 10 mVP-P 90 % Page 1 of 4 DM1810-916MR - 4/17/08 D M 1 8 1 0 -9 1 6 M R B lo c k D ia g r a m J 1 -1 0 G N D J 3 -3 J 3 -2 G N D J 3 -1 T R 8 1 0 0 A S H T r a n s c e iv e r C N T R L 0 J 1 -9 C N T R L 1 J 1 -8 R X D A T A J 1 -7 T X M O D P IC 1 6 F 6 8 9 P R S S I L E D D 1 J 4 -1 D 2 J 4 -2 L E D G N D 1 J 1 -6 J 1 -5 3 V R e g J 1 -4 B IN D J 1 -3 V O U T J 1 -2 V IN J 1 -1 G N D 2 Figure 1 Theory of Operation The major components of the DM1810-916MR include an RFM TR8100 ASH transceiver and a Microchip PIC16F689 microcontroller. The TR8100 operates on a frequency of 916.50 MHz, at a nominal output power of 10 mW. The DM1810-916MR includes two LEDs that indicate the module's operating mode. The DM1810-916MR firmware is based on RFM's miniMESH network protocol, which utilizes timesynchronized redundant routing to provide robust, deterministic packet delivery though a network with up to 15 routers. Network configuration and maintenance features are built into the miniMESH protocol, simplifying commissioning and operating logistics. The firmware also includes several sleep cycling methods for extended battery life operation. Please refer to the DM1810 User's Guide and the AN1810 series Application Notes for installation and application programming information. See the RFM web site at www.RFM.com. DM1810-916MR FCC Certification The DM1810-916MR hardware has been certified for operation under FCC Part 15 Rules, Section 15.247. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or www.RFM.com E-mail: info@rfm.com (c)2008 by RF Monolithics, Inc. operating in conjunction with any other antenna or transmitter. FCC Notices and Labels This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. A clearly visible label is required on the outside of the user's (OEM) enclosure stating that this product contains a DM1810-916MR transceiver assembly, FCC ID: HSW-DM1810A. WARNING: This device operates under Part 15 of the FCC rules. Any modification to this device, not expressly authorized by RFM, may void the user's authority to operate this device. Canadian Department of Communications Industry Notice - IC: 4492A-DM1810A This apparatus complies with Health Canada's Safety Code 6 / IC RSS 210. To prevent radio interference to the licensed service, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors may be subject to licensing. Page 2 of 4 DM1810-916MR - 4/17/08 ICES-003 This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of Industry Canada. Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de Classe B prescrites dans le reglement sur le brouillage radioelectrique edicte par Industrie Canada. DM1810-916MR I/O Pad Descriptions Pin Name Description J1-1 GND This pad is a signal and power supply ground. J1-2 VIN This is the power supply input pad. The allowed input voltage range is 2.6 to 10 V. J1-3 VOUT VOUT tracks 50 to 100 mV below VIN when VIN is in the range of 2.6 to 3.1 V. When VIN is in the range of 3.1 to 10 V, VOUT is regulated at 3.0 Vdc. Up to 10 mA can be supplied from this pad for powering external circuits such as thermistor-resistor networks. External circuitry must not impress more than 10 mVp-p ripple on the regulated output voltage. J1-4 BIND This pad is connected to a logic input on the microcontroller, and is configured with a weak pull-up. When this pin is momentarily grounded to J1-1 or J1-10, the module is placed into the bind mode, allowing this module to be associated with other modules to form a network. J1-5 - This pad is unused in router operation. Leave this pad electrically unconnected. J1-6 - This pad is unused in router operation. Leave this pad electrically unconnected. J1-7 - This pad is unused in router operation. Leave this pad electrically unconnected. J1-8 - This pad is unused in router operation. Leave this pad electrically unconnected. J1-9 - This pad is unused in router operation. Leave this pad electrically unconnected. J1-10 GND This pad is a signal and power supply ground. J3-1 GND This pad is a ground for the antenna port. J3-2 ANT This pad is the antenna port. J3-3 GND This pad is a ground for the antenna port. J4-1 D1 This pad is the LED 1 signal. J4-2 D2 This pad is the LED 2 signal. CAUTION: Electrostatic Sensitive Device. Observe precautions when handling. www.RFM.com E-mail: info@rfm.com (c)2008 by RF Monolithics, Inc. Page 3 of 4 DM1810-916MR - 4/17/08 D M 1 8 1 0 -9 1 6 M R I/O P a d L a b e ls G N D V IN V O U T G N D B IN D D 1 R F IO D 2 G N D G N D Figure 2 D M 1 8 1 0 -9 1 6 M R S M T M o u n tin g P a tte r n 1 .4 8 5 .0 9 5 .1 2 0 .1 2 0 .1 0 0 T Y P .2 0 0 .0 9 0 .1 0 0 e .1 n n a e r a s o ld 0 0 u c le n te n e r a n p a ra n a n te la n p n te d c e h o le a d (d o n a p a d ) .0 7 0 T Y P P la c a n te u n d n o t .0 9 0 .2 0 0 .1 3 0 1 .0 0 0 .1 8 0 D im e n s io n s in in c h e s . P C B p lu s c o m p o n e n t h e ig h t is .1 7 0 m a x ; P C B p lu s a n te n n a h e ig h t is 2 .1 5 m a x Figure 3 Note: Specifications subject to change without notice. www.RFM.com E-mail: info@rfm.com (c)2008 by RF Monolithics, Inc. Page 4 of 4 DM1810-916MR - 4/17/08