Fuse Modules EMG ...-SI 1. Description Actuators, motors, lamps, transformers, and semiconductor components must be protected against current overload. A distinction is made between two fuse versions: - Modules with three or eight fuse holders with screw caps for 5 x 20 mm (0.197 x 0.787 in.) G fuse links. - Modules with two or six fuse holders with indicator screw connections for 5 x 25 mm (0.197 x 0.984 in.) G fuse links. The versions are available as fuse paths that can be individually wired or as fuse distributors with common potential input. The G fuse link is not supplied as standard. Phoenix Contact GmbH & Co. KG * 32825 Blomberg, Germany Phone +49 - 52 35 - 30 0 * Fax +49 - 52 35 - 34 12 00 * www.phoenixcontact.com Local Contact: www.phoenixcontact.com/salesnetwork Fuse Modules EMG 22-SI 2. Technical Data for EMG 22-SI 1 3 5 7 2 4 6 8 L L L 5 1 2 3 4 62 mm (2.441 in.) EMG 22-SI3E EMG 22-SI3S 75 mm (2.953 in.) 8 mm (0.31 in.) EMG 22-SI With 3 G fuse holders Module width 22.5 mm (0.886 in.) M3 solid [mm2] flexible Connection data 0.2 - 4 0.2 - 2.5 * The current is determined by the fuse. AWG I [A] U [V] 25 - 12 * 250 Description Fuse module For 3 G fuse links 5 x 20 mm (0.197 x 0.787 in.) Individual connection Common centralized point Device marker Order No. EMG 22-SI3E EMG 22-SI3S 29 52 27 9 29 55 77 1 10 EMG-GKS 29 47 03 5 50 Technical Data 250 V AC 6.3 A/250 V AC, maximum 3 A/250 V AC, maximum Maximum voltage Fuse links1) (between two terminal blocks) Fuse links1) (for simultaneous load of the links) General Data Ambient operating temperature range Standards/specifications -20C to +50C (-4F to +122F) IEC 664/IEC 664 A/DIN VDE 0110-1:1989-01, degree of pollution 2, Surge Voltage Category III; DIN VDE 0109-11:1987-12, draft DIN VDE 0160:1988-05 Any Can be mounted without spacing Screw connection Mounting position Mounting Connection type 1 Pcs. Pkt. Type )The values specified only apply for G fuse links from Wickmann. Phoenix Contact page 2 of 5 Fuse Modules EMG 45-SI 3. Technical Data for EMG 45-SI 1 3 2 4 5 7 9 11 13 15 6 8 10 12 14 16 L L 1 2 L L L L L L 3 4 5 6 7 8 62 mm (2.441 in.) EMG 45-SI8E EMG 45-SI8S 75 mm (2.953 in.) 8 mm (0.31 in.) EMG 45-SI With 8 G fuse holders Module width 45 mm (1.772 in.) M3 solid [mm2] flexible Connection data 0.2 - 4 0.2 - 2.5 * The current is determined by the fuse. AWG I [A] U [V] 25 - 12 * 250 Description Fuse module For 8 G fuse links 5 x 20 mm (0.197 x 0.787 in.) Individual connection Common centralized point Device marker Order No. EMG 45-SI8E EMG 45-SI8S 29 54 94 7 29 54 95 0 5 5 EMG-GKS 29 47 03 5 50 Technical Data Maximum voltage Fuse links1) (between two terminal blocks) Fuse links1) (for simultaneous load of the links) 250 V AC 6.3 A/250 V AC, maximum 3 A/250 V AC, maximum General Data Ambient operating temperature range Standards/specifications -20C to +50C (-4F to +122F) IEC 664/IEC 664 A/DIN VDE 0110-1:1989-01, degree of pollution 2, Surge Voltage Category III; DIN VDE 0109-11:1987-12, draft DIN VDE 0160:1988-05 Any Can be mounted without spacing Screw connection Mounting position Mounting Connection type 1 Pcs. Pkt. Type )The values specified only apply for G fuse links from Wickmann. Phoenix Contact page 3 of 5 Fuse Modules EMG 17-SI/K 4. Technical Data for EMG 17-SI/K 1 3 2 4 L L 1 67 mm (2.638 in.) EMG 17-SI2E/K L 2 EMG 17-SI2S/K 75 mm (2.953 in.) 8 mm (0.31 in.) M3 solid [mm2] flexible Connection data 0.2 - 4 0.2 - 2.5 * The current is determined by the fuse. AWG I [A] U [V] 25 - 12 * 250 Description Fuse module with indicator For 2 G fuse links 5 x 25 mm (0.197 x 0.984 in.) Individual connection Common centralized point Device marker EMG 17-SI/K With 2 G fuse holders and cap for fuse with indicator Module width 17.5 mm (0.689 in.) Order No. EMG 17-SI2E/K EMG 17-SI2S/K 29 55 78 4 29 55 79 7 10 EMG-GKS 29 47 03 5 50 Technical Data 250 V AC 6.3 A/250 V AC, maximum 4 A/250 V AC, maximum Maximum voltage Fuse links1) (between two terminal blocks) Fuse links1) (for simultaneous load of the links) General Data Ambient operating temperature range Standards/specifications -20C to +50C (-4F to +122F) IEC 664/IEC 664 A/DIN VDE 0110-1:1989-01, degree of pollution 2, Surge Voltage Category III; DIN VDE 0109-11:1987-12, draft DIN VDE 0160:1988-05 Any Can be mounted without spacing Screw connection Mounting position Mounting Connection type 1 Pcs. Pkt. Type )The values specified only apply for G fuse links from Wickmann. Phoenix Contact page 4 of 5 Fuse Modules EMG 45-SI/K 5. Technical Data for EMG 45-SI/K 1 2 3 5 7 9 11 4 6 8 10 12 L 1 L L L L L 2 3 4 5 6 67 mm (2.638 in.) EMG 45-SI6E/K EMG 45-SI6S/K 75 mm (2.953 in.) 8 mm (0.31 in.) EMG 45-SI/K With 6 G fuse holders and cap for fuse with indicator Module width 45 mm (1.772 in.) M3 solid [mm2] flexible Connection data 0.2 - 4 0.2 - 2.5 * The current is determined by the fuse. AWG I [A] U [V] 25 - 12 * 250 Description Fuse module with indicator For 6 G fuse links 5 x 25 mm (0.197 x 0.984 in.) Individual connection Common centralized point Device marker Pcs. Pkt. Type Order No. EMG 45-SIDE/K EMG 45-SI6S/K 29 55 80 7 29 55 81 0 5 5 EMG-GKS 29 47 03 5 50 Technical Data Maximum voltage Fuse links1) (between two terminal blocks) Fuse links1) (for simultaneous load of the links) 250 V AC 6.3 A/250 V AC, maximum 3 A/250 V AC, maximum General Data Ambient operating temperature range Standards/specifications Mounting position Mounting Connection type 1 )The values specified only apply for G fuse links from Wickmann. Phoenix Contact page 5 of 5 TNR: 101179-00-gb/06/30/03 (c) Phoenix Contact 2003 -20C to +50C (-4F to +122F) IEC 664/IEC 664 A/DIN VDE 0110-1:1989-01, degree of pollution 2, Surge Voltage Category III; DIN VDE 0109-11:1987-12, draft DIN VDE 0160:1988-05 Any Can be mounted without spacing Screw connection