1. Description
Actuators, motors, lamps, transformers, and semi-
conductor components must be protected against
current overload.
A distinction is made between two fuse versions:
Modules with three or eight fuse holders with screw
caps for 5 x 20 mm (0.197 x 0.787 in.) G fuse links.
Modules with two or six fuse holders with indicator
screw connections for 5 x 25 mm (0.197 x 0.984 in.)
G fuse links.
The versions are a v ailable as fuse paths that can be
individually wired or as fuse distributors with common
potential input. The G fuse link is not supplied as
standard.
Fuse Modules
EMG ...-SI
Phoenix Contact GmbH & Co. KG • 32825 Blomberg, Ger many
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
Local Contact: www.phoenixcontact.com/salesnetwork
Phoenix Contact page 2 of 5
Fuse Modules EMG 22-SI
2. Technical Data for EMG 22-SI
solid exible I U
[mm
2
]AWG[A] [V]
Connection data 0.2 - 4 0.2 - 2.5 25 - 12 * 250
* The current is determined by the fuse.
Description
Fuse module
For 3 G fuse links
5 x 20 mm (0.197 x 0.787 in.) Individual connection
Common centralized point
Device marker
Technical Data
Maximum voltage
Fuse links
1
) (between two terminal blocks)
Fuse links
1
) (for simultaneous load of the links)
General Data
Ambient operating temperature range
Standards/specications
Mounting position
Mounting
Connection type
1
)The values specied only apply for G fuse links from Wickmann.
EMG 22-SI
With 3 G fuse holders
Module width 22.5 mm (0.886 in.)
Type Order No.
Pcs.
Pkt.
EMG 22-SI3E
EMG 22-SI3S 29 52 27 9
29 55 77 1
10
EMG-GKS 29 47 03 5
50
250 V A C
6.3 A/250 V AC, maximum
3 A/250 V AC, maximum
-20°C to +50°C (-4˚F to +122˚F)
IEC 664/IEC 664 A/DIN VDE 0110-1:1989-01,
degree of pollution 2, Surge Voltage Category III;
DIN VDE 0109-11:1987-12, draft
DIN VDE 0160:1988-05
Any
Can be mounted without spacing
Screw connection
75 mm (2.953 in.)
62 mm
(2.441 in.)
2468
1357
LLL5
1234
EMG 22-SI3E
EMG 22-SI3S
M 3
8 mm
(0.31 in.)
Phoenix Contact page 3 of 5
Fuse Modules EMG 45-SI
3. Technical Data for EMG 45-SI
solid exible I U
[mm
2
]AWG[A] [V]
Connection data 0.2 - 4 0.2 - 2.5 25 - 12 * 250
* The current is determined by the fuse.
Description
Fuse module
For 8 G fuse links
5 x 20 mm (0.197 x 0.787 in.) Individual connection
Common centralized point
Device marker
Technical Data
Maximum voltage
Fuse links
1
) (between two terminal blocks)
Fuse links
1
) (for simultaneous load of the links)
General Data
Ambient operating temperature range
Standards/specications
Mounting position
Mounting
Connection type
1
)The values specied only apply for G fuse links from Wickmann.
EMG 45-SI
With 8 G fuse holders
Module width 45 mm (1.772 in.)
Type Order No.
Pcs.
Pkt.
EMG 45-SI8E
EMG 45-SI8S 29 54 94 7
29 54 95 0
5
5
EMG-GKS 29 47 03 5
50
250 V A C
6.3 A/250 V AC, maximum
3 A/250 V AC, maximum
-20°C to +50°C (-4˚F to +122˚F)
IEC 664/IEC 664 A/DIN VDE 0110-1:1989-01,
degree of pollution 2, Surge Voltage Category III;
DIN VDE 0109-11:1987-12, draft
DIN VDE 0160:1988-05
Any
Can be mounted without spacing
Screw connection
75 mm (2.953 in.)
62 mm
(2.441 in.)
1357911
13 15
2468
10 12 14 16
LLLLLLLL
12345678
EMG 45-SI8E
EMG 45-SI8S
M 3
8 mm
(0.31 in.)
Phoenix Contact page 4 of 5
Fuse Modules EMG 17-SI/K
4. Technical Data for EMG 17-SI/K
solid exible I U
[mm
2
]AWG[A] [V]
Connection data 0.2 - 4 0.2 - 2.5 25 - 12 * 250
* The current is determined by the fuse.
Description
Fuse module with indicator
For 2 G fuse links
5 x 25 mm (0.197 x 0.984 in.) Individual connection
Common centralized point
Device marker
Technical Data
Maximum voltage
Fuse links
1
) (between two terminal blocks)
Fuse links
1
) (for simultaneous load of the links)
General Data
Ambient operating temperature range
Standards/specications
Mounting position
Mounting
Connection type
1
)The values specied only apply for G fuse links from Wickmann.
EMG 17-SI/K
With 2 G fuse holders and cap for fuse with indicator
Module width 17.5 mm (0.689 in.)
Type Order No.
Pcs.
Pkt.
EMG 17-SI2E/K
EMG 17-SI2S/K 29 55 78 4
29 55 79 7
10
EMG-GKS 29 47 03 5
50
250 V A C
6.3 A/250 V AC, maximum
4 A/250 V AC, maximum
-20°C to +50°C (-4˚F to +122˚F)
IEC 664/IEC 664 A/DIN VDE 0110-1:1989-01,
degree of pollution 2, Surge Voltage Category III;
DIN VDE 0109-11:1987-12, draft
DIN VDE 0160:1988-05
Any
Can be mounted without spacing
Screw connection
75 mm (2.953 in.)
67 mm
(2.638 in.)
13
24
LL
12
L
EMG 17-SI2E/K
EMG 17-SI2S/K
M 3
8 mm
(0.31 in.)
Phoenix Contact page 5 of 5
TNR: 101179-00-gb/06/30/03 © Phoenix Contact 2003
Fuse Modules EMG 45-SI/K
5. Technical Data for EMG 45-SI/K
solid exible I U
[mm
2
]AWG[A] [V]
Connection data 0.2 - 4 0.2 - 2.5 25 - 12 * 250
* The current is determined by the fuse.
Description
Fuse module with indicator
For 6 G fuse links
5 x 25 mm (0.197 x 0.984 in.) Individual connection
Common centralized point
Device marker
Technical Data
Maximum voltage
Fuse links
1
) (between two terminal blocks)
Fuse links
1
) (for simultaneous load of the links)
General Data
Ambient operating temperature range
Standards/specications
Mounting position
Mounting
Connection type
1
)The values specied only apply for G fuse links from Wickmann.
EMG 45-SI/K
With 6 G fuse holders and cap for fuse with indicator
Module width 45 mm (1.772 in.)
Type Order No.
Pcs.
Pkt.
EMG 45-SIDE/K
EMG 45-SI6S/K 29 55 80 7
29 55 81 0
5
5
EMG-GKS 29 47 03 5
50
250 V A C
6.3 A/250 V AC, maximum
3 A/250 V AC, maximum
-20°C to +50°C (-4˚F to +122˚F)
IEC 664/IEC 664 A/DIN VDE 0110-1:1989-01,
degree of pollution 2, Surge Voltage Category III;
DIN VDE 0109-11:1987-12, draft
DIN VDE 0160:1988-05
Any
Can be mounted without spacing
Screw connection
75 mm (2.953 in.)
67 mm
(2.638 in.)
1357911
2468
10 12
LLLLLL
123456
EMG 45-SI6E/K
EMG 45-SI6S/K
M 3
8 mm