SPECIFICATION
90W AC-DC Single Output Desktop GST90A ser ie s
File Name:GST90A-SPEC 2015-01-13
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE Note.8
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 9)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GST90A15-P1MGST90A12-P1M GST90A19-P1M GST90A24-P1M GST90A48-P1M
15V12V
GST90A15GST90A12
19V
GST90A19
24V
GST90A24
48V
GST90A48
150mVp-p120mVp-p 180mVp-p 200mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.91 / 230VAC PF>0.95 / 115VAC at full load
89.5%
89% 90% 90% 91%
1.3A / 115VAC 0.6A / 230VAC
70A / 230VAC
1mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
348.7K hrs min. MIL-HDBK-217F(25℃)
-30 ~ +70℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03% / ℃ (0~40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/1CUFT
CONNECTOR
PLUG
CABLE See page 3 ; Other type available by customer requested
℃
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
6A6.67A 4.74A 3.75A 1.87A
0 ~ 6A0 ~ 6.67A 0 ~ 4.74A 0 ~ 3.75A
0 ~ 1.87A
90W80W 90W 90W 90W
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1 approved
SETUP, RISE TIME Note.7
HOLD UP TIME (Typ.)
1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load
20ms / 230VAC 20ms / 115VAC at full load
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
EMC IMMUNITY
EMC EMISSION
See page 3 ; Other type available by customer requested