Honeywell Pressure Switches 50094081 HP, HE, MH, ME, LP, LE, 5000, and 1000 Series Issue 5 Datasheet DESCRIPTION The Honeywell Pressure Switch portfolio consists of: * High Pressure (HE/HP Series) * Medium Pressure (ME/MH Series) * Low Pressure (LE/LP Series) * 5000 Series, 1000 Series These pressure switches are durable, reliable electromechanical gauge pressure on/off switches that are available with either single pole single throw (SPST) normally open or normally closed circuitry, or single pole double throw (SPDT) circuitry. Their high proof pressure and burst pressure ratings can allow for use in many rugged applications that require the making or breaking of an electrical connection in response to a pressure change of the system media. FEATURES * * * * * * * * Pressure switching set point range: 3.5 psi to 4500 psi Proof pressure: from 500 psi up to 10,000 psi Burst pressure: from 1250 psi up to 20,000 psi Life cycle rating up to 2 million IP67 sealing rating4 Operating temperature: -40 C to 120 C [-40 F to 248 F] Hysteresis option5 More than 15 pressure port options and over 30 electrical terminations * Plated steel, brass or stainless steel options3 * Switching point accuracy up to 2 % POTENTIAL APPLICATIONS DIFFERENTIATION * Through optional smart diagnostic technology, Honeywell pressure switches are able to detect failures such as open circuits, cut wires, worn insulation, and more6 * Optional smart diagnostic technology allows up to four segregated signal amplitudes to perform diagnostics and status6 * Pressure port snubber suppresses pressure spikes2 * IP67 sealing provides enhanced durability in harsh environmental and washing applications1 * Agricultural machinery * Heavy duty construction machinery and trucks * Lawn & garden machinery * Marine vessels * Material handling machinery * Railway VALUE TO CUSTOMERS * Designed to provide resistance to corrosion and enhances equipment life with available two million life cycle rating and IP67 rating1 * Can expedite design and product cycle due to ability to receive samples in two weeks and production units in four weeks * Can reduce tooling, service, and manufacturing labor costs due to standard connections, extended product life, and expedited design and production cycle Safety and Productivity Solutions PORTFOLIO * CNC machines * Compressors/boilers * Fracking equipment * Food & beverage equipment * Generators * HVAC/R equipment * Mud pumps * Pneumatic equipment * Presses/punches * Pressure washers * Trash compactors * Water pumps & jet cutting machines Honeywell also offers the PBN1 Series and PBN3 Series Pressure Sensor. HP, HE, MH, ME, LP, LE Series HP, HE Series 3 ME, MH, LP, LE Series 4 HP, HE, LP, LE, ME Series 5 HP, HE, LP Series 6 HP, HE, ME, LP, LE Series 1 2 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series Table 1. Specifications Characteristic Product length (various terminations) Product length (blade) Product length (#8-32 screws) Product length (Metripack) Hex size Ease of installation Snap-action switch Set point1 range Set point ranges Set point accuracy @ 25 C (before test) Average deadband max. Operating pressure2 Proof pressure3 Hysteresis Burst pressure4 HP Series HE Series ME Series MH Series LP Series LE Series 5000 Series 1000 Series see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 see page 10 - see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 65,6 mm [2.583 in] see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 27 mm 27 mm 27 mm 27 mm 27 mm 27 mm 58,42 mm [2.3 in] 60,96 mm [2.4 in] 73,66 mm [2.9 in] 0.50 in (steel) 0.437 in (brass) box spanner box spanner box spanner box spanner box spanner box spanner 1/2 in open spanner yes yes no no yes no no no 100 psi to 4500 psi 150 psi to 4500 psi 6 (Base Style A) 7 (Base Style B) 6 - - M10 x 1.25 banjo fitting 18 mm open spanner 25 psi to 350 psi 40 psi to 500 psi 3.5 psi to 150 psi 3.5 psi to 150 psi 75 psi to 150 psi 10 psi to 60 psi [0,69 bar to 2,7 bar] 4 4 4 4 8 - 25 psi to 50 psi 100 psi to 150 psi 150 psi to 1000 psi (3 psi); (10 %); (14%); >50 psi to 100 psi 150 psi to 500 psi 1000 psi to (7 psi); (6 %); 2000 psi >100 psi to 150 psi 501 psi to 4000 psi (12 %); (10 psi); (3.5 %); 2000 psi to >150 psi to 250 psi 4000 psi to 4500 4000 psi (13 psi); psi (11 %); >250 psi to 350 psi (2 %) >4000 psi (10 %) (16 psi) 40 psi to 70 psi (7 psi); >70 psi to 130 psi (10 psi); >130 psi to 200 psi (15 psi); >200 psi to 280 psi (20 psi); >280 psi to 350 psi (30 psi); >350 psi to 500 psi (40 psi) 40 psi to 70 psi (6 psi); >70 psi to 130 psi (10 psi); >130 psi to 200 psi (15 psi); >200 psi to 280 psi (20 psi); >280 psi to 350 psi (30 psi); >350 psi to 500 psi (40 psi) n/a 3.5 psi to 10 psi (2.8 psi); >10 psi to 50 psi (14 psi); >50 psi to 100 psi (38 psi); >100 psi to 150 psi (40 psi) 3.5 psi to 10 psi (1 psi); >10 psi to 50 psi (3 psi); >50 psi to 100 psi (7 psi); >100 psi to 150 psi (10 psi) 0.5 psi to 1 psi (0.3 psi); 1.1 psi to 3 psi (0.5 psi); 3.1 psi to 7 psi (1 psi); 8 psi to 13 psi (2 psi); 14 psi to 24 psi (3 psi); 25 psi to 50 psi (5 psi); 51 psi to 90 psi (7 psi); 91 psi to 150 psi (10 psi) 0.5 psi to 3 psi (1.5 psi); 4 psi to 7 psi (2.5 psi); 8 psi to 13 psi (3.5 psi); 14 psi to 24 psi (8 psi); 25 psi to 50 psi (15 psi); 51 psi to 90 psi (23 psi); 91 psi to 150 psi (40 psi) 20 psi 10 psi; 58 psi 20 psi n/a n/a 25 psi to 50 psi (20 psi); >50 psi to 100 psi (30 psi); >100 psi to 150 psi (40 psi); >150 psi to 250 psi (50 psi); >250 psi to 350 psi (60 psi) 5,000 psi max. 5,000 psi max. 500 psi max. 600 psi max. 250 psi max. 250 psi max. 150 psi, 250 psi 1400 psi [96,5 bar] max. 10,000 psi 4,000 psi 6,000 psi 500 psi 500 psi 500 psi 2973 psi [205 bar] 3 % to 65 % (based on set point range) n/a n/a 5 % to 55 % (based on set point range) n/a n/a n/a 20,000 psi 8,000 psi 9,000 psi 1250 psi 1250 psi 4000 psi 3500 psi [241 bar] 15 A, 6 Vdc; 8 A, 12 Vdc; 4 A, 24 Vdc 12 Vdc with two1157 bulbs (4.4 A) 1 A, 120 Vac 0.5 A, 240 Vac n/a 10,000 psi (Base Style A) 6,500 psi (Base Style B) 5 % to 55 % (based on set point range) 20,000 psi (Base Style A); 9,000 psi (Base Style B) Current rating (resistive) 5 A at 250 Vac 5 A at 24 Vdc 3 A at 250 Vac 3 A at 24 Vdc Current rating (inductive) 5 A at 115 Vac (SX rating); 3 A at 28 Vdc n/a 7.5 mA to 3 A, 7.5 mA to 5 A, 7.5 mA to 3 A, 100 mA to 3 A max. 24 Vdc and 250 Vac 24 Vdc and 250 Vac 24 Vdc and 250 Vac n/a n/a 1 A at 28 Vdc n/a Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A. Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A. Port Styles A, B, E, M, P, T, and Y will use Base Style B. Switches less than 150 psi will only use Base Style B. 8 2 sensing.honeywell.com n/a Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series Characteristic HP Series HE Series ME Series MH Series LP Series LE Series 5000 Series 1000 Series Rated thermal current 5A 3A 3A n/a 5A 3A n/a n/a Rated insulation voltage 28 V 28 V 28 V n/a 28 V 28 V n/a n/a Class J fuse (10 A, 600 V) n/a Class J fuse (10 A, 600 V) n/a n/a 1000 A n/a n/a n/a 3 (macro environment) n/a n/a n/a Short-circuit protective device c-type max. rating Conditional short circuit current Pollution degree Temperature rating Media connection Pressure ports Life -40 C to 120 C [-40 F to 248 F] -40 C to 121 C [-40 F to 250 F] -20 C to 74 C [-4 F to 165 F] multiple ports available multiple ports available multiple ports available 1/8-27 NPT male thread multiple ports available C = 1/2-20 UNF F = M14 x 1.5 G =9/16-18 UNF H = 3/4-16 UNF K = M18 x 1.5 N = 7/8-14 UNF Refer to product nomenclature for pressure port types. SPDT, SPST - NO/NC - A = 1/4-18 NPT B = 1/8-27 NPT C = 1/2-20 UNF D = 1/8-27 PTF E = M12 x 1.5 F = M14 x 1.5 G = 9/16-18 UNF H = 3/4-16 UNF J = G1/8 BSPP M = 7/16-20 UNF R = R1/8 BSPT T = M10 x 1.0 V = R1/2 BSPT Y = G1/4 BSPP Z = R1/4 BSPT A = 1/4-18 NPT B = 1/8-27 NPT C = 1/2-20 UNF D = 1/8-27 PTF E = M12 x 1.5 F = M14 x 1.5 G = 9/16-18 UNF H = 3/4-16 UNF J = G1/8 BSPP M = 7/16-20 UNF R = R1/8 BSPT T = M10 x 1.0 V = R1/2 BSPT Y = G1/4 BSPP Z = R1/4 BSPT 1/8-27 NPT SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPST-NO; SPST-NC single- or dual-resistor topology available M10 x 1.25 double banjo; M10 x 1; 1/8-27 NPT SPNO - - 1 million 2 million 1 million 100,000 cycles 100,000 cycles - - - - UL Custom (select models) - CE CE CE CE CE - - no no yes yes yes yes yes no yes yes no no no no no no IP67 (connecetors) IP67 (wire/Base A) IP69K (wire/Base B) IP00 (blade/screw) IP67 (connectors) IP00 (blade/screw) IP67 (connectors) IP67 (wire out) IP00 (blade/screw) IP67 (connectors) IP00 (blade/screw) IP67 (connectors) IP67 (wire out) IP00 (blade/screw) IP67 (connectors) IP67 (wire out) IP00 (blade/screw) IP00 IP65 - - - Agency approvals (other) CE Vibration resistance Shock resistance A = 1/4-18 NPT B = 1/8-27 NPT C = 1/2-20 UNF D = 1/8-27 PTF E = M12 x 1.5 F = M14 x 1.5 G = 9/16-18 UNF H = 3/4-16 UNF J = G1/8 BSPP L = 3/8-24 UNF M = 7/16-20 UNF P = 1/2-14 NPT R = R1/8 BSPT T = M10 x 1.0 V = R1/2 BSPT Y = G1/4 BSPP Z = R1/4 BSPT SPDT, SPST - NO/NC SPST - NO/NC A = 1/4-18 NPT B = 1/8-27 NPT C = 1/2-20 UNF D = 1/8-27 PTF E = M12 x 1.5 F = M14 x 1.5 G = 9/16-18 UNF H = 3/4-16 UNF J = G1/8 BSPP M = 7/16-20 UNF R = R1/8 BSPT T = M10 x 1.0 V = R1/2 BSPT Y = G1/4 BSPP Z = R1/4 BSPT single- or dual-resistor topology available 2 million (Base A) 1 million 1 million 1 million (Base B) - Ingress protection7 3 (macro environment) -40 C to 85 C [-40 F to 185 F] Agency approvals (special use switches) Field adjustability6 Spike dampening 1000 A -40 C to 120 C [-40 F to 248 F] Circuit forms5 Smart pressure 1000 A swept sine: 10 Hz to 2000 Hz at 15 g, 20 min/sweep; 8 hours in each axis random: 5 Hz to 2000 Hz, 8 hours/axis; 14,88 g-RMS, each axis 500 m/sec2, 11 mSEC, 100 shocks / axis 500 m/sec2, 11 mSEC 15 G @ 5 mSEC Wetted part (diaphragm) n/a Kapton(R) (Teflon(R) coated) Nitrile/EPDM/LTNB Kapton(R) (Teflon(R) coated) Tefzel(R) Polymide film EPDM Wetted part (piston) nitrile o-ring, steel piston nitrile or EPDM o-ring nitrile or EPDM o-ring nitrile or EPDM o-ring nitrile or EPDM o-ring nitrile or EPDM o-ring EPDM 133 g [4.7 oz] (Base Style A) 178 g [6.28 oz] (Base Style B) 53 g [1.9 oz] 53 g [1.9 oz] 58 g [2.0 oz] 53 g [1.9 oz] 65 g [2.3 oz] 40 g [1.4 oz] Weight Contacts Product finish silver / gold inlay silver gold plated gold plated gold plated gold plated silver-plated copper silver-plated copper zinc plating zinc plating zinc plating zinc plating zinc plating zinc plating Rynite 545 glass glass reinforced filled (housing); polyester (housing); Travalent plated steel plated steel (base) (base) Set point: Point at which switch actuates or de-actuates Operating pressure: Maximum normal system operating pressure 3 Proof pressure: Maximum pressure that the switch can handle while it maintains set point accuracy. Intermittent spikes to this level are acceptable. 4 Burst pressure: Point of complete switch failure 5 SPST: Single pole, single throw. SPDT: Single pole, double throw. NO: Normally open. NC: Normally closed. 6 Field adjustability only available with AA, BA, CA, and DA (SPST only) terminations. 7 IP00 for AA and BA terminations. Safety and Productivity Solutions 1 2 3 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series Table 2. Terminations Series Available Terminations HP, HE, ME, LP, LE AA = Spade Terminals BA = Screw Terminals CA = Deutsch DT04-3P-E005 (3-Pin Connector) DA = Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) EA = 10-inch Cable, 18 AWG (Wire Out, No Connector) FA = 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* GA = 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)* HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)* JA = 10-inch Cable w/Din43650-C (3-Pin Connector) (18 AWG)* KA = 10-inch Cable w/M12x1 (Brad Harrison Micro) - 21032121306 Harting P/N (3-Pin Connector) (18 AWG)* LA = 10-inch Cable w/Packard Weatherpack Male Terminal - 12020827 (3-Pin Connector) (18 AWG)* MA = 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2-Pin Connector) (18 AWG) PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (18 AWG) RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (16 AWG) SA = 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector - SS2R-120-1804-000 (2-Pin Connector) (18 AWG) TA = 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector - SS3R-120-8551-001 (3-Pin Connector) (16 AWG)* UA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)* VA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)* XA = 10-inch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG) YA = 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* ZA = 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) AB = Deutsch DT04-2P-E005 (2-Pin Connector) BB = 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)* CB = 6-inch Cable w/ AMP Super Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG) DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) GB = 8.5-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG) MH AA = Spade Terminals BA = Screw Terminals DA = Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) EA = 10-inch Cable, 18 AWG (Wire Out, No Connector) HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)* MA = 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2-Pin Connector) (18 AWG) PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (18 AWG) RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (16 AWG) SA = 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector - SS2R-120-1804-000 (2-Pin Connector) (18 AWG) WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)* XA = 10-inch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG) YA = 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* ZA = 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) AB = Deutsch DT04-2P-E005 (2-Pin Connector) CB = 6-inch Cable w/ AMP Super Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG) DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. 4 sensing.honeywell.com Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series DIMENSIONS - HIGH PRESSURE: HP SERIES (BASE STYLE A), HE SERIES Base Style A key specifications * Life: 2 million (HP), 1 million (HE); Burst pressure: 20,000 psi Figure 1. AMP Superseal 1.5 27 mm [1.063] hex A/F 61,64 mm [2.427 in] 20,02 mm [0.788 in] (bottom view) (top view) Female Connector Part Number (included): C-282105 Male Mating Connector (customer provided): C-282087 IP Rating: IP67 Figure 2. Deutsch 27 mm [1.063] hex A/F 61,64 mm [2.427 in] 21,16 mm [0.833 in] (bottom view) (top view) Female Connector Part Number (included): DT04-3P Male Mating Connector (customer provided): DT06-3S IP Rating: IP67 Figure 3. Spade Terminal 27 mm [1.063] hex A/F 61,64 mm [2.427 in] 14,43 mm [0.568 in] (bottom view) (top view) Figure 4. Screw Terminal 27 mm [1.063] hex A/F 61,64 mm [2.427 in] 12,65 mm [0.498 in] (bottom view) (top view) Figure 5. Cable 27 mm [1.063] hex A/F (top view) 61,64 mm [2.427 in] 19,51 mm [0.768 in] (bottom view) IP Rating: IP67 Safety and Productivity Solutions 5 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series DIMENSIONS - HIGH PRESSURE: HP SERIES (BASE STYLE B) Base Style B key specifications * Life: 1 million; Burst pressure: 9,000 psi Figure 6. HP Series Base Style B 71,47 mm [2.814 in] 14,43 mm [0.568 in] HP with smaller port: dimension 2.814 in remains same for all base ports. (bottom view) Figure 7. HP Series Pressure Port Dimensions "H" Thread "H" Thread "O D" "O D" "A" "H" Thread "O D" "O C" Table 3. HP/HE Series Pressure Port Diameters and Heights Nomenclature Code Thread Height "A" Diameter "OD" Diameter "OC" Height "H" M 7/16-20 UNF - 9,25 mm [0.364 in] - 11 mm [0.433 in] C1 1/2-20 UNF - 10,85 mm [0.427 in] - 11 mm [0.433 in] G 9/16-18 UNF - 12,24 mm [0.482 in] - 12 mm [0.472 in] H 3/4-16 UNF - 16,74 mm [0.66 in] - 14 mm [0.551 in] N 7/8-14 UNF - 19,6 mm [0.773 in] - 16 mm [0.630 in] T M10 x 1.0 1,60 mm [0.063 in] 9,25 mm [0.364 in] 13,79 mm [0.543 in] 11 mm [0.433 in] E M12 x 1.5 2,48 mm [0.098 in] 10,85 mm [0.427 in] 16,79 mm [0.661 in] 11 mm [0.433 in] F M14 x 1.5 2,48 mm [0.098 in] 12,24 mm [0.482 in] 18,8 mm [0.74 in] 12 mm [0.472 in] K M18 x 1.5 2,48 mm [0.098 in] 16,74 mm [0.66 in] 23,8 mm [0.937 in] 14 mm [0.551 in] B 1/8-27 NPT - 10,29 mm [0.405 in] - 12,497 mm [0.492 in] A 1/4-18 NPT - 13,72 mm [0.540 in] - 17,63 mm [0.694 in] 2 2 Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A. Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A. Switches less than 150 psi will use only Base Style B. 1 2 6 sensing.honeywell.com Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series DIMENSIONS - MEDIUM PRESSURE: MH SERIES Figure 8. AMP Superseal 1.5 (bottom view) Figure 13. MH Series Pressure Port Dimensions 67,06 mm max. [2.64 in] max. Figure 9. Deutsch 2-pin "A" (bottom view) 67,06 mm max. [2.64 in] max. Table 4. MH Series Pressure Port Diameters and Heights Port Figure 10. Wire out (bottom view) 50,29 mm max. [1.98 in] max. Figure 11. Blade terminal Diameter "OD" Height "H" R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in] R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in] R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in] 1/8-27 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in] 1/4-18 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in] 1/8-27 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in] G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in] G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in] 3/4-16 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in] 7/16-20 UNF 9,25 mm [0.364 in] 9,09 mm [0.358 in] 9/16-18 UNF 12,24 mm [0.482 in] 10,00 mm[0.394 in] 1/2-20 UNF 10,85 mm [0.427 in] 9,09 mm [0.358 in] Height "A" Diameter "OC" Diameter "OD" Height "H" M14 x 1.5 2,49 mm [0.098 in] 18,8 mm [0.74 in] 11,71 mm [0.461 in] 10,998 mm [0.433 in] M12 x 1.5 2,49 mm [0.098 in] 16,79 mm [0.661 in] 9,70 mm [0.382 in] 10,998 mm [0.433 in] M10 x 1.0 1,6 mm [0.063 in] 13,79 mm [0.543 in] 8,41 mm [0.331 in] 8,51 mm [0.335 in] Port (bottom view) 38,35 mm max. [1.51 in] max. Figure 12. Screw terminal (bottom view) 38,35 mm max. [1.51 in] max. Safety and Productivity Solutions 7 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series DIMENSIONS - MEDIUM PRESSURE: ME SERIES Figure 14. AMP Superseal 1.5 Figure 20. ME Series Pressure Port Dimensions H H 65,3 mm max. [2.57 in] max. (bottom view) OD OD Female connector part number (included): C-282105 Male mating connector (customer provided): C-282087 IP rating: IP67 Figure 15. Deutsch 3-pin A H OD 64 mm max. [2.52 in] max. (bottom view) Female connector part number (included): DT04-3P Male mating connector (customer provided): DT06-3S IP rating: IP67 OC Table 5. ME Series Pressure Port Diameters and Heights Port Diameter "OD" Height "H" R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in] R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in] R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in] 1/8-27 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in] 1/4-18 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in] Female connector part number (included): DT04-2P Male mating connector (customer provided): DT06-2S IP rating: IP67 1/8-27 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in] G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in] Figure 17. Wire out G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in] 3/4-16 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in] Figure 16. Deutsch 2-pin 65,5 mm max. [2.58 in] max. (bottom view) 48,51 mm max. [1.91 in] max. (bottom view) IP rating: IP67 Figure 18. Blade terminal 38,9 mm max. [1.57 in] max. (bottom view) Figure 19. Screw terminal (bottom view) 8 sensing.honeywell.com 38,9 mm max. [1.57 in] max. 7/16-20 UNF 9,25 mm [0.364 in] 9,09 mm [0.358 in] 9/16-18 UNF 12,24 mm [0.482 in] 10,00 mm[0.394 in] 1/2-20 UNF 10,85 mm [0.427 in] 9,09 mm [0.358 in] Height "A" Diameter "OC" Diameter "OD" Height "H" M14 x 1.5 2,49 mm [0.098 in] 18,8 mm [0.74 in] 11,71 mm [0.461 in] 10,998 mm [0.433 in] M12 x 1.5 2,49 mm [0.098 in] 16,79 mm [0.661 in] 9,70 mm [0.382 in] 10,998 mm [0.433 in] M10 x 1.0 1,6 mm [0.063 in] 13,79 mm [0.543 in] 8,41 mm [0.331 in] 8,51 mm [0.335 in] Port Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series DIMENSIONS - LOW PRESSURE: LP SERIES, LE SERIES Figure 21. AMP Superseal 1.5 Figure 27. LP/LE Series Pressure Port Dimensions H H 58,93 mm max. [2.32 in] max. (bottom view) OD OD Figure 22. Deutsch 3-pin A H OD 57,66 mm max. [2.27 in] max. (bottom view) OC Table 6. LP/LE Series Pressure Port Diameters and Heights Figure 23. Deutsch 2-pin Port 58,93 mm max. [2.32 in] max. (bottom view) Figure 24. Wire out 42,16 mm max. [1.66 in] max. (bottom view) IP rating: IP67 Height "H" R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in] R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in] R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in] 1/8-27 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in] 1/4-18 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in] 1/8-27 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in] G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in] G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in] 3/4-16 UNF 16,74 mm [0.659 in] 11,1 mm [0.437 in] 7/16-20 UNF 9,25 mm [0.364 in] 9,09 mm [0.358 in] 9/16-18 UNF 12,24 mm [0.482 in] 10,00 mm [0.394 in] 1/2-20 UNF 10,85 mm [0.427 in] 9,09 mm [0.358 in] Height "A" Diameter "OC" Diameter "OD" Height "H" M14 x 1.5 2,49 mm [0.098 in] 18,8 mm [0.74 in] 11,71 mm [0.461 in] 10,998 mm [0.433 in] M12 x 1.5 2,49 mm [0.098 in] 16,79 mm [0.661 in] 9,70 mm [0.382 in] 10,998 mm [0.433 in] M10 x 1.0 1,6 mm [0.063 in] 13,79 mm [0.543 in] 8,41 mm [0.331 in] 8,51 mm [0.335 in] Port Figure 25. Spade terminal 33,02 mm max. [1.30 in] max. (bottom view) Diameter "OD" Figure 26. Screw terminal (bottom view) 33,02 mm max. [1.30 in] max. Safety and Productivity Solutions 9 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series DIMENSIONS - 1000 SERIES, 5000 SERIES Figure 28. 1000 Series Dimensions 11,18 mm [0.44 in] min. last full thread ref. 12,4 mm [0.488 in] 6,02 mm [0.237 in] 33,1 mm [1.303 in] 31,5 mm [1.24 in] 65,6 mm [2.583 in] 55,11 mm [2.17 in] 34,85 mm [1.37 in] 5,5 mm [0.22 in] M 10 x 1.25 -6G 45 45 3,2 mm [0.13 in] 2X 9,91 mm [0.39 in] 8,99 mm [0.35 in] 1,5 x 45 2,1 mm [0.08 in] O2,5 cross drill 0.25 x 45 chamfer Figure 29. 5000 Series Dimensions 8-32 x 1/4 screw (3) 1/8-27 NPT 0.500 hex ref. O 37,34 mm [O 1.47 in] ref. 58,42 mm [2.3 in] ref. 10 sensing.honeywell.com Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series NOMENCLATURE: HIGH PRESSURE For example, HPR05500PFNSPAAA01 defines a high pressure switch, rising factory set, non-adjustable set point, 550 psi set point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO silver contacts output, cold-rolled steel base, glycol-based fluid (EPDM) actuation/application, spade terminal connectors, standard switch, individually boxed units. HP R Series Set Point HP Series HE Series (100 psi to 4500 psi), High Pressure Switch P F N S P AA A 01 Pressure Unit Port Type Output Base Actuation/ Application Connector Type Options Packaging Options 05500 Pressure Set Point R Rising factory set, non-adjustable 6,89 bar to 310,26 bar [100 psi to 4500 psi] F Falling factory set, non-adjustable NOTE: Pressure set point is always five digits. NOTE: Set point below 100 psi For bar, the set point is available only with value will be multiplied HP Series (Body Style B). by 100 and entered in the listing. For example, 15,45 Bar is noted as 01545. This allows for 2 decimal places. For psi, the set point value will be multiplied by 10 and entered in the listing. For example, 245.5 psi is noted as 02455. This allows for 1 decimal place. P psig, sealed gage B bar, sealed gage A N 1/4-18 NPT SPST-NO, silver contacts S Cold-rolled steel N Petroleum-based hydraulic fluid (Nitrile) Glycol-based fluid (EPDM) A Standard switch 01 Individually boxed units* BA Screw Terminals* B With 3 shrink sleeve 02 boxed units** CA Deutsch DT04-3P-E005 (3-Pin Connector)* C With shrink sleeve (plastic coating) packed in 15 boxes bulk packaging* AA 1/4 in Spade Terminals* Individually B 1/8-27 NPT C SPST-NC, silver contacts C 1/2-20 UNF D SPDT-NO/NC, silver contacts E M12 x 1.5 H NO, gold inlay contacts DA Amp Super Seal 1.5 282105-1 (3-Pin Connector)* D With shrink sleeve (acrylic coating) packed in 16 boxes bulk packaging** F M14 x 1.5 J NC, gold inlay contacts EA 10-inch Cable, 18 AWG (Wire Out, No Connector) F 304,8 mm [12 in] total wire length packed in 20 boxes bulk packaging* G 9/16-18 UNF K SPDT(NO/NC), gold inlay contacts FA 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* G With conduit sleeve packed in 21 boxes bulk packaging** H 3/4-16 UNF E NO, with 510 / 0.5 W & 160 / 0.5 W resistors GA 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)* H With Vibra seal for port threads units in 25 25 bulk packaging* HA 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG) J #8-32 screw with external tooth lockwasher*** 26 bulk packaging** in 50 parts bulk packaging* P EDPM O-ring option only available from 100 psi to 250 psi. NC, with 3000 / 0.125 W resistor K M18 x 1.5 M 7/16-20 UNF JA 10-inch Cable w/ Din43650-C (3-Pin Connector) (18 AWG)* K 914,4 mm [36 in] total wire length N 7/8-14 UNF KA 10-inch Cable w/M12x1 (Brad Harrison Micro) 21032121306 Harting P/N (3-Pin Connector) (18 AWG)* L 304,8 mm [12 in] total wire length with acrylic sleeve M 914,4 mm [36 in] total wire length with acrylic sleeve T F M10 x 1.0 HP Series Port Types Thread Type Base Style A Base Style B A = 1/4-18 NPT n/a 100 psi to 4500 psi B = 1/8-27 NPT n/a 100 psi to 4500 psi C = 1/2-20 UNF >975 psi n/a E = M12 x 1.5 n/a 100 psi to 4500 psi F = M14 x 1.5 >350 psi n/a G = 9/16-18 UNF >350 psi <350 psi H = 3/4-16 UNF >150 psi <150 psi K = M18 x 1.5 150 psi to 4500 psi n/a M = 7/16-20 UNF n/a 100 psi to 4500 psi N = 7/8-14 UNF 150 psi to 4500 psi n/a T = M10 x 1.0 n/a 100 psi to 4500 psi Port Type A, B, E, M, and T will be available only with HP Series. Base Style B will be available only with HP Series LA 10-inch Cable w/Packard Weatherpack Male Terminal 12020827 (3-Pin Connector) (18 AWG)* MA 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) NA 3-inch Cable w/Packard 2P Tower Connector 12015792 (2-Pin Connector) (18 AWG) PA 2.75-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (18 AWG) RA 4-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (16 AWG) SA 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector SS2R-120-1804-000 (2-Pin Connector) (18 AWG) TA UA 25 individual 25 individual 50 individual 50 individual 25 units in 50 individual * Not applicable for HP Series (Base Style B) ** Not applicable for HP (Base Style A) & HE Series *** For screw terminal option only 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector SS3R-120-8551-001 (3-Pin Connector) (16 AWG)* 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)* VA 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* WA 4.5-inch Cable w/ 1/4 in Spade Terminals 6,3 mm x 0,8 mm (16 AWG) XA 10-inch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG) YA 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG) ZA 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) BB 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG) CB 6-inch Cable w/ AMP Super Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG) DB 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) GB 8.5-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)* *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. Safety and Productivity Solutions 11 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series NOMENCLATURE: MEDIUM PRESSURE, HIGH BURST For example, MHR01500PFPVMAAA01 defines a medium pressure, high burst switch, rising factory set, non-adjustable set point, 150 psi set point, psig, sealed gage pressure unit, 1/4-18 NPT port type, SPST-NO contacts output, stainless steel base, LTNB diaphragm, and spade terminal connectors. MH R 01500 P A P N M AA A 01 Series Set Point Pressure Set Point Pressure Unit Port Type Output Base Actuation/ Application Connector Type Options Packaging Options MH Series Medium R Pressure F Switch Rising factory set, non-adjustable Falling factory set, non-adjustable T Rising, field adjustable* C Falling, field adjustable* * Field adjustable option is only available for: 1. Blade and screw terminations (SPDT, SPNO, SPNC) 2. Deutsch DT04-3P (SPDT, SPNO, SPNC) 3. Amp Superseal 1.5 (3-pin) (SPNO & SPNC) 0,24 bar to 10,34 bar [3.5 psi to 150 psi] NOTE: Pressure set point is always five digits. For bar, the set point value will be multiplied by 100 and entered in the listing. For example, 15,45 Bar is noted as 01545. This allows for 2 decimal places. For psi, the set point value will be multiplied by 10 and entered in the listing. For example, 245.5 psi is noted as 02455. This allows for 1 decimal place. P psig, sealed gage A 1/4-18 NPT B bar, sealed gage B 1/8-27 NPT M bar, true gage* C 1/2-20 UNF T psig, true gage* D 1/8-27 PTF P M SPST-NO SPST-NC N Cold-rolled steel A Standard switch 01 Individually boxed units Screw Terminals C With shrink sleeve (plastic coating) packed in 15 boxes bulk packaging DA Amp Super Seal 1.5 282105-1 (3-Pin Connector) D With shrink sleeve (acrylic coating) units in 20 150 bulk packaging EA 10-inch Cable, 18 AWG (Wire Out, No Connector) F 304,8 mm [12 in] total wire length 25 bulk packaging 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)* G With conduit sleeve packed in 30 boxes bulk packaging H With Vibra seal for threads J #8-32 screw with external tooth lockwasher*** K 914,4 mm [36 in] total wire length L 304,8 mm [12 in] total wire length w/ shrink sleeve M 914,4 mm [36 in] total wire length w/ shrink sleeve AA M LTNB diaphragm (Low-temp Buna N) BA B Brass N HNBR diaphragm (Hydrogenated Nitrile Butadiene Rubber) V Stainless steel E EPDM diaphragm (Ethylene-PropyleneDiene Monomer) G psig, sealed gage with epoxy** E M12 x 1.5 HA H bar, sealed gage with epoxy** F M14 x 1.5 MA G 9/16-18 UNF NA H 3/4-16 UNF J G1/8 BSPP L 3/8-24 UNF *Blade and screw electrical terminations are available with only the the true gage option. **Connector cavity and roll forming area filled with epoxy to meet dunk test sealing capability. 1/4 in Spade Terminals 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) 3-inch Cable w/Packard 2P Tower Connector 12015792 (2-Pin Connector) (18 AWG) PA 2.75-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (18 AWG) RA 4-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (16 AWG) SA 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector SS2R-120-1804-000 (2-Pin Connector) (18 AWG) M 7/16-20 UNF P 1/2-14 NPT WA 4.5-inch Cable w/ 1/4 in Spade Terminals 6,3 mm x 0,8 mm (16 AWG)* R R1/8 BSPT XA 10-inch Cable w/ Metripack 2-Pin Shroud Connector 153000287 (18 AWG) T M10 x 1.0 YA 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* V R1/2 BSPT ZA 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) Y G1/4 BSPP AB Deutsch DT04-2P-E005 (2-Pin Connector) Z R1/4 BSPT CB 6-inch Cable with Amp Super Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG) DB 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) ***applicable only for screw terminal version. *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. 12 sensing.honeywell.com 25 individual 25 units in 150 individual Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series NOMENCLATURE: MEDIUM PRESSURE For example, MER01500PFPVKAAA01 defines a medium pressure switch, rising factory set, non-adjustable set point, 55 psi set point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO gold-plated contacts output, stainless steel base, Kapton(R) diaphragm (Teflon(R) coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed units. ME R 01500 P F P V K AA A 01 Series Set Point Pressure Set Point Pressure Unit Port Type Output Base Actuation/ Application Connector Type Options Packaging Options ME Series Medium R Pressure F Switch T C Rising factory set, non-adjustable Falling factory set, non-adjustable Rising, field adjustable* Falling, field adjustable* * Field adjustable option is only available for: 1. Blade and screw terminations (SPDT, SPNO, SPNC) 2. Deutsch DT04-3P (SPDT, SPNO, SPNC) 3. Amp Superseal 1.5 (3-pin) (SPNO & SPNC) 1,72 bar to 24,13 bar [25 psi to 350 psi] NOTE: Pressure set point is always five digits. For bar, the set point value will be multiplied by 100 and entered in the listing. For example, 15,45 Bar is noted as 01545. This allows for 2 decimal places. For psi, the set point value will be multiplied by 10 and entered in the listing. For example, 245.5 psi is noted as 02455. This allows for 1 decimal place. P B psig, sealed gage bar, sealed gage A B 1/4-18 NPT 1/8-27 NPT M SPST-NO, gold-plated contacts SPST-NC, gold-plated contacts H bar, sealed gage with epoxy G 9/16-18 UNF 01 Individually boxed units H Kapton diaphragm (Teflon(R) coated), EPDM O-ring2 BA Screw Terminals B With 3 shrink sleeve packed in 15 boxes bulk packaging units in 20 150 bulk packaging 25 bulk packaging NC, with 3000 / 0.125 W resistor EA 10-inch Cable, 18 AWG (Wire Out, No Connector) E With 1/8 W resistor between terminals packed in 30 boxes bulk packaging FA 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* F 304,8 mm [12 in] total wire length GA 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)* G With conduit sleeve H With Vibra seal for port threads J #8-32 screw with external tooth lockwasher 1 2 Air, Petroleum-based hydraulic fluid, engine oil Glycol-based fluid H 3/4-16 UNF HA 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)* J G1/8 BSPP JA 10-inch Cable w/ Din43650-C (3-Pin Connector) (18 AWG)* M 7/16-20 UNF KA 10-inch Cable w/M12x1 (Brad Harrison Micro) 21032121306 Harting P/N (3-Pin Connector) (18 AWG)* K 914,4 mm [36 in] total wire length R R1/8 BSPT LA R With port neck O-ring for LPS T 10-inch Cable w/Packard Weatherpack Male Terminal 12020827 (3-Pin Connector) (18 AWG)* M10 x 1.0 V MA 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) R1/2 BSPT NA 3-inch Cable w/Packard 2P Tower Connector 12015792 (2-Pin Connector) (18 AWG) PA 2.75-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (18 AWG) RA 4-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (16 AWG) SA 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector SS2R-120-1804-000 (2-Pin Connector) (18 AWG) Y G1/4 BSPP Z R1/4 BSPT 25 individual With shrink sleeve (acrylic coating) M14 x 1.5 psig, sealed gage with epoxy Standard switch D F G A Amp Super Seal 1.5 282105-1 (3-Pin Connector) F D 1/4 in Spade Terminals DA M12 x 1.5 psig, true gage AA (R) NO, with 510 / 0.5 W & 160 / 0.5 W resistors E T Kapton(R) diaphragm (Teflon(R) coated), Nitrile O-ring1 C E 1/2-20 UNF Stainless steel K Deutsch DT04-3P-E005 (3-Pin Connector) 1/8-27 PTF C V Cold-rolled steel with zinc plating CA SPDT-NO/NC, gold-plated contacts bar, true gage N With shrink sleeve (plastic coating) Y M Blade and screw electrical terminations are available with only the the true gage option. P TA UA VA 150 individual *** For screw terminal option only 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector SS3R-120-8551-001 (3-Pin Connector) (16 AWG)* 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)* 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* XA 4.5-inch Cable w/ 1/4 in Spade Terminals 6,3 mm x 0,8 mm (16 AWG)* 10-inch Cable w/ Metripack 2-Pin Shroud Connector 153000287 (18 AWG) YA 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* ZA 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) AB Deutsch DT04-2P-E005 (2-Pin Connector) BB 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)* CB 6-inch Cable with Amp Super Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG) DB 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) GB 8.5-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG) WA 25 units in *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. Safety and Productivity Solutions 13 Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series NOMENCLATURE: LOW PRESSURE For example, LPR00550PFPVKAAA01 defines a low pressure switch, rising factory set, non-adjustable set point, 55 psi set point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO gold-plated contacts output, stainless steel base, Kapton(R) diaphragm (Teflon(R) coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed units. LP R 00550 P F P V K AA A 01 Series Set Point Pressure Set Point Pressure Unit Port Type Output Base Actuation/ Application Connector Type Options Packaging Options LP Series, LE Series R Low F Pressure Switch T C Rising factory set, non-adjustable Falling factory set, non-adjustable Rising, field adjustable* Falling, field adjustable* * Field adjustable option is only available for: 1. Blade and screw terminations (SPDT, SPNO, SPNC) 2. Deutsch DT04-3P (SPDT, SPNO, SPNC) 3. Amp Superseal 1.5 (3-pin) (SPNO & SPNC) 0,24 bar to 10,34 bar [3.5 psi to 150 psi] NOTE: Pressure set point is always five digits. For bar, the set point value will be multiplied by 100 and entered in the listing. For example, 15,45 Bar is noted as 01545. This allows for 2 decimal places. For psi, the set point value will be multiplied by 10 and entered in the listing. For example, 245.5 psi is noted as 02455. This allows for 1 decimal place. P B M psig, sealed gage bar, sealed gage bar, true gage A B C 1/4-18 NPT 1/8-27 NPT 1/2-20 UNF P M Y SPST-NO, gold-plated contacts SPST-NC, gold-plated contacts SPDT-NO/NC, gold-plated contacts B Brass N Cold-rolled steel with zinc plating V Stainless steel K Kapton(R) diaphragm (Teflon(R) coated), Nitrile O-ring1 H Kapton diaphragm (Teflon(R) coated), EPDM O-ring2 T Tefzel and Kapton diaphragm, Nitrile O-ring3 CA U Tefzel and Kapton diaphragm, EPDM O-ring4 (R) (R) (R) (R) (R) AA 1/4 in Spade Terminals A Standard switch 01 Individually boxed units BA Screw Terminals B With 3 shrink sleeve packed in 15 boxes bulk packaging Deutsch DT04-3P-E005 (3-Pin Connector) C With shrink sleeve (plastic coating) units in 20 150 bulk packaging DA Amp Super Seal 1.5 282105-1 (3-Pin Connector)** D With shrink sleeve (acrylic coating) 25 bulk packaging EA 10-inch Cable, 18 AWG (Wire Out, No Connector)* F 304,8 mm [12 in] total wire length packed in 30 boxes bulk packaging FA 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* G With conduit sleeve GA 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)* H With Vibra seal for port threads T psig, true gage D 1/8-27 PTF E NO, with 510 / 1 W & 160 / 1 W resistors**** G psig, sealed gage with epoxy E M12 x 1.5 F NC, with 3000 / 0.125 W resistor H bar, sealed gage with epoxy F M14 x 1.5 G NC with 510 / 0.5 W and 160 / 0.5 W resistors**** G 9/16-18 UNF H 3/4-16 UNF HA 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)* K 914,4 mm [36 in] total wire length J G1/8 BSPP JA 10-inch Cable w/ Din43650-C (3-Pin Connector) (18 AWG)* L 304,8 mm [12 in] total wire length with acrylic sleeve M 7/16-20 UNF KA 10-inch Cable w/M12x1 (Brad Harrison Micro) 21032121306 Harting P/N (3-Pin Connector) (18 AWG)* M 914,4 mm [36 in] total wire length with acrylic sleeve R R1/8 BSPT LA T 10-inch Cable w/Packard Weatherpack Male Terminal 12020827 (3-Pin Connector) (18 AWG)* M10 x 1.0 V MA 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) R1/2 BSPT NA 3-inch Cable w/Packard 2P Tower Connector 12015792 (2-Pin Connector) (18 AWG) PA 2.75-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (18 AWG) RA 4-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (16 AWG) SA 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector SS2R-120-1804-000 (2-Pin Connector) (18 AWG) Blade and screw electrical terminations are available with only the the true gage option. True gage option is available only up to 20 psig set point for integral connectors and wire out electrical terminations. Y G1/4 BSPP Z R1/4 BSPT **** Available only on LP Series Air, Petroleum-based hydraulic fluid, engine oil Glycol-based fluid 3 For high temperature fluid media (LE Series only) 4 For high temperature fluid media, glycol-based fluid (LE Series only) 1 2 TA UA VA 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector SS3R-120-8551-001 (3-Pin Connector) (16 AWG)* 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)* 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* XA 4.5-inch Cable w/ 1/4 in Spade Terminals 6,3 mm x 0,8 mm (16 AWG)* 10-inch Cable w/ Metripack 2-Pin Shroud Connector 153000287 (18 AWG) YA 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* ZA 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) AB Deutsch DT04-2P-E005 (2-Pin Connector) BB 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)* CB 6-inch Cable with Amp Super Seal 1.5 - 282080-1 (2-Pin Connector) (18 AWG) DB 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) GB 8.5-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG) WA *** For screw terminal option only *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. **For electrical termination with SPST option, only SPNO configuration is available. SPNC configuration cannot be provided. 14 sensing.honeywell.com 25 individual 25 units in 150 individual m WARNING ADDITIONAL MATERIALS The following associated literature is available at sensing.honeywell.com: * Product range guide * Product line guide PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. * Technical note: Smart Diagnostic Technology * Product application-specific information - Application Note: Honeywell Pressure Switches m WARNING - Sensors and switches in front loaders MISUSE OF DOCUMENTATION - Sensors and switches in mobile cranes * - Sensors and switches in oil rig applications - Industrial product line card * The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell's sensing and switching products, Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer's sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Honeywell Safety and Productivity Solutions 9680 Old Bailes Road Fort Mill, SC 29707 honeywell.com 50094081-5-EN IL50 GLO October 2016 (c) 2016 Honeywell International Inc. All rights reserved. (R) DuPontTM, Teflon(R), Tefzel(R), and Kapton(R) are trademarks or registered trademarks of E.I. du Pont de Nemours and Company