30 Watt
1“x1“
Single & Dual
Output
Features
Regulated
Converters
• 4:1 Wide Input Voltage Range
• 1.6kVDC Isolation
• UL, IEC/EN and EN50155 Certified
• Efficiency Up To 89%
• OVP, OCP & OTP
• +105°C max Case Temperature
PD-1
REV.: 5/2018www.recom-power.com
DC/DC Converter
3
Y
E
A
R
w
a
r
r
a
n
t
y
3
E224736
RPA30-AW
Selection Guide
Part Number Input Output Output Input(1) Efficiency(1) Max. Capacitive
Voltage Range Voltage Current Current typ. Load
[VDC] [VDC] [mA] [mA] [%] [µF]
RPA30-243.3SAW(2,3) 9-36 3.3 7500 1172 88 10000
RPA30-2405SAW(2,3) 9-36 5 6000 1404 89 10000
RPA30-2412SAW(2,3) 9-36 12 2500 1420 88 1000
RPA30-2415SAW(2,3) 9-36 15 2000 1420 88 1000
RPA30-2412DAW(2,3) 9-36 ±12 ±1250 1420 88 ±1000
RPA30-2415DAW(2,3) 9-36 ±15 ±1000 1420 88 ±680
UL60950-1 Certified
IEC/EN60950 Certified
EN50155 Certified
Ordering Examples
RPA30-243.3SAW = 24V Input, 3.3V Output, Single, no CTRL pin
RPA30-2405SAW/P = 24V Input, 5V Output, Single, Pos. CTRL function
RPA30-2415SAW-HC = 24V Input, 15V Output, Single, no CTRL pin, glued Heat-sink
RPA30-2415DAW/N-HC = 24V Input, 15V Output, Dual, Neg. CTRL function, glued Heat-sink
Model Numbering
Input Voltage
Output Voltage
Single or Dual
RPA30-__ __ _AW/_ _
Notes:
Note2: part without suffixes is without CTRL pin, trim pin fitted
add suffix “P” for positive CTRL function (1=ON, 0=OFF), trim pin fitted
add suffix “N” for negative CTRL function (0=ON, 1=OFF), trim pin fitted
trim pin is only available for single outputs
Note3: add suffix “-HC” for glued Heat-sink (compatible with all other suffixes)
Package (3)
CTRL Logic (2)
Description
The RPA30-AW series are high power density, wide input voltage range 30W DC/DC converters in
an industry standard 1”x1” case size. Despite their small size, the RPA30-AW converters are fully
specified devices with output currents up to 7.5Amps, up to 89% efficiency, no minimum load, 1600VDC
isolation, tight regulation and low ripple/noise figures. The outputs are also fully protected against
over-temperature, short circuits, overcurrent and overvoltage and the single output version
offers a ±10% trim range. A heatsink option is available to extend the operating temperature range.
The converters are UL and EN50155 certified and will find many uses in railway and industrial
applications where board space is at a premium.
Notes:
Note1: Tested at nominal Vin, full load and at +25°C ambient