30 Watt
1“x1“
Single & Dual
Output
Features
Regulated
Converters
4:1 Wide Input Voltage Range
1.6kVDC Isolation
UL, IEC/EN and EN50155 Certified
Efficiency Up To 89%
OVP, OCP & OTP
+105°C max Case Temperature
PD-1
REV.: 5/2018www.recom-power.com
DC/DC Converter
3
Y
E
A
R
w
a
r
r
a
n
t
y
3
E224736
RPA30-AW
Selection Guide
Part Number Input Output Output Input(1) Efficiency(1) Max. Capacitive
Voltage Range Voltage Current Current typ. Load
[VDC] [VDC] [mA] [mA] [%] [µF]
RPA30-243.3SAW(2,3) 9-36 3.3 7500 1172 88 10000
RPA30-2405SAW(2,3) 9-36 5 6000 1404 89 10000
RPA30-2412SAW(2,3) 9-36 12 2500 1420 88 1000
RPA30-2415SAW(2,3) 9-36 15 2000 1420 88 1000
RPA30-2412DAW(2,3) 9-36 ±12 ±1250 1420 88 ±1000
RPA30-2415DAW(2,3) 9-36 ±15 ±1000 1420 88 ±680
UL60950-1 Certified
IEC/EN60950 Certified
EN50155 Certified
Ordering Examples
RPA30-243.3SAW = 24V Input, 3.3V Output, Single, no CTRL pin
RPA30-2405SAW/P = 24V Input, 5V Output, Single, Pos. CTRL function
RPA30-2415SAW-HC = 24V Input, 15V Output, Single, no CTRL pin, glued Heat-sink
RPA30-2415DAW/N-HC = 24V Input, 15V Output, Dual, Neg. CTRL function, glued Heat-sink
Model Numbering
Input Voltage
Output Voltage
Single or Dual
RPA30-__ __ _AW/_ _
Notes:
Note2: part without suffixes is without CTRL pin, trim pin fitted
add suffix “P” for positive CTRL function (1=ON, 0=OFF), trim pin fitted
add suffix “N” for negative CTRL function (0=ON, 1=OFF), trim pin fitted
trim pin is only available for single outputs
Note3: add suffix “-HC” for glued Heat-sink (compatible with all other suffixes)
Package (3)
CTRL Logic (2)
Description
The RPA30-AW series are high power density, wide input voltage range 30W DC/DC converters in
an industry standard 1”x1” case size. Despite their small size, the RPA30-AW converters are fully
specified devices with output currents up to 7.5Amps, up to 89% efficiency, no minimum load, 1600VDC
isolation, tight regulation and low ripple/noise figures. The outputs are also fully protected against
over-temperature, short circuits, overcurrent and overvoltage and the single output version
offers a ±10% trim range. A heatsink option is available to extend the operating temperature range.
The converters are UL and EN50155 certified and will find many uses in railway and industrial
applications where board space is at a premium.
Notes:
Note1: Tested at nominal Vin, full load and at +25°C ambient
PD-2 REV.: 5/2018 www.recom-power.com
DC/DC Converter
RPA30-AW
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Internal Input Filter Pi-Type
Input Voltage Range 9VDC 24VDC 36VDC
Input Surge Voltage 100ms max. 50VDC
Quiescent Current
Start-up time Power up
CTRL ON/OFF 8ms 16ms
Internal Operating Frequency 550kHz
Minimum Load 0%
Ripple and Noise 20MHz BW, 10µF tantalum capacitor and 1µF ceramic capacitor 50mVp-p
Under Voltage Lockout (UVLO) DC-DC ON
DC-DC OFF
8VDC
7VDC
8.5VDC
7.5VDC
9VDC
8VDC
ON/OFF Control
Positive Logic DC-DC ON
DC-DC OFF
Open or 2.4 < Vr < 10VDC
Short or 0 < Vr < 0.8VDC
Negative Logic DC-DC ON
DC-DC OFF
Short or 0 < Vr < 0.8VDC
Open or 2.4 < Vr < 10VDC
Input current of CTRL pin 6mA
Output Voltage Trimming Single Outputs -10% +10%
continued on next page
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted
Efficiency vs. Output Current
Efficiency vs. Output Current
9Vin
24Vin
36Vin
Efficiency [%]
Output Current [%]
100 20 40 60 80 10030 50 70 90
0
10
20
30
40
50
60
70
80
90
100
Power Dissipation
Output Current [A]
0
0
1
1
0.5
2
2
1.5
3
3
2.5
4
3.5
4.5
5
5.5
456
9Vin
24Vin
36Vin
RPA30-2405SAW
RPA30-243.3SAW
Power Dissipation vs Output Current
Power Dissipation vs Output Current
9Vin
24Vin
36Vin
Efficiency [%]
Output Current [%]
100 20 40 60 80 10030 50 70 90
0
10
20
30
40
50
60
70
80
90
100
Power Dissipation
Output Current [A]
0
0
1.5
1
0.5
3
2
1.5
4.5
3
2.5
4
3.5
4.5
5
5.5
6
6 7.5
9Vin
24Vin
36Vin
continued on next page
DC/DC Converter
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted
RPA30-AW
Series
PD-3
REV.: 5/2018www.recom-power.com
Efficiency vs. Output Current
Efficiency vs. Output Current
Efficiency vs. Output Current
9Vin
24Vin
36Vin
Output Current [A]
Power Dissipation
0
01.510.5
1
0.5
2
2
1.5
3
2.5
4
3.5
4.5
5
5.5
2.5
9Vin
24Vin
36Vin
Efficiency [%]
Output Current [%]
100
0
10
20
30
40
50
60
70
80
90
100
20 40 60 80 10030 50 70 90
RPA30-2412SAW
RPA30-2415SAW
RPA30-2412DAW
Power Dissipation vs Output Current
Power Dissipation vs Output Current
Power Dissipation vs Output Current
9Vin
24Vin
36Vin
Efficiency [%]
Output Current [%]
100 20 40 60 80 10030 50 70 90
0
10
20
30
40
50
60
70
80
90
100
Power Dissipation
Output Current [A]
0
0
0.4
1
0.5
0.8
2
1.5
1.2
3
2.5
4
3.5
4.5
5
5.5
1.6 2
9Vin
24Vin
36Vin
9Vin
24Vin
36Vin
Efficiency [%]
Output Current [%]
100 20 40 60 80 10030 50 70 90
0
10
20
30
40
50
60
70
80
90
100
Power Dissipation
Output Current [A]
0
0
0.25
1
0.5
0.5
2
1.5
0.75
3
2.5
4
3.5
4.5
5
5.5
1 1.25
9Vin
24Vin
36Vin
OUTPUT TRIM
continued on next page
PD-4 REV.: 5/2018 www.recom-power.com
DC/DC Converter
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted
RPA30-AW
Series
RPA30-2405SAW
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 5.05 5.10 5.15 5.20 5.25 5.30 5.35 5.40 5.45 5.50 Volts
RU = 604 243 147 95.3 68.1 39.2 34.8 22.1 15 8.06 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 4.55 4.50 Volts
RD = 604 287 169 124 105 78.7 54.9 39.2 15 0.5 kOhms
RPA30-2412SAW
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 12.12 12.24 12.36 12.48 12.6 12.72 12.84 12.96 13.08 13.20 Volts
RU = 604 267 162 105 75 499 40.2 24.9 18.2 10 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 10.92 10.80 Volts
RD = 750 309 200 124 90.9 64.9 45.3 32.4 20 12.1 kOhms
RPA30-243.3SAW
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 3.33 3.36 3.39 3.43 3.46 3.49 3.53 3.56 3.59 3.63 Volts
RU = 402 169 100 75 47.5 34.8 26.1 17.8 12.1 8.06 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 3.27 3.23 3.20 3.17 3.14 3.10 3.07 3.04 3.0 2.97 Volts
RD = 402 191 113 75 52.3 39.2 26.7 20 12.1 8.06 kOhms
RU
55
6
RD
4
Output Voltage Trimming
RPA30-AW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim
resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may
slightly vary.
Efficiency vs. Output Current
9Vin
24Vin
36Vin
Efficiency [%]
Output Current [%]
100 20 40 60 80 10030 50 70 90
0
10
20
30
40
50
60
70
80
90
100
Power Dissipation
Output Current [A]
0
0
0.2
2.0
1.2
0.4
0.4
2.8
0.6
3.6
4.4
5.2
0.8 1
9Vin
24Vin
36Vin
RPA30-2415DAW Power Dissipation vs Output Current
TRIM DOWN
TRIM UP
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range (6) -40°C to [refer to thermal calculation]
Maximum Case Temperature +105°C
Temperature Coefficient 0.02%/°C
Thermal Impedance please refer to table 1
Operating Altitude 2000m
Operating Humidity 95% RH
Shock 5G, 30ms, 6 times along X,Y and Z axis
Vibration 10-500Hz, 2.4G, 30mins along X,Y and Z axis
MTBF according to Telcordia SR332 3, +25°C 5888 x 103 hours
continued on next page
DC/DC Converter
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted
RPA30-AW
Series
PD-5
REV.: 5/2018www.recom-power.com
PROTECTION
Parameter Condition Value
Short Circuit Protection (SCP) below 100mcontinuous, auto recovery
Over Voltage Protection (OVP) 115%-150% Output Voltage, Hiccup, auto recovery
Over Current Protection (OCP) 110%-160% Output Current, Hiccup
Over Temperature Protection (OTP) +115°C ±5°C
Isolation Voltage (5) I/P to O/P tested for 1 minute 1.6kVDC
Isolation Resistance 10M min.
Isolation Capacitance 1100pF typ.
Insulation Grade basic
Notes:
Note4: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: 4A slow blow type.
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage.
REGULATION
Parameter
Condition
Value
Output Accuracy Single & Dual ±2.0% max.
Line Regulation low line to high line Single
Dual
±0.2% max.
±0.5% max.
Load Regulation
3.3Vout
5Vout
12Vout, 15Vout
±12Vout, ±15Vout
±0.3%
±0.2%
±0.1%
±1.0%
Cross Regulation asymmetrical 25%<>100% load ±3.0% max.
Transient Response 50-75%, full load, 0.1A/µs ±3.0% Vout typ.
25% load step change 250µs typ.
RPA30-2415SAW
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 15.15 15.30 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 Volts
RU = 1000 243 200 130 90.9 61.9 40.2 30.1 24.9 10 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 14.85 14.70 14.55 14.40 14.25 14.10 13.95 13.80 13.65 13.50 Volts
RD = 1000 348 210 140 95.3 68.1 45.3 30.1 18.2 8.06 kOhms
PD-6 REV.: 5/2018 www.recom-power.com
DC/DC Converter
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted
RPA30-AW
Series
Ambient Temperature [°C] Ambient Temperature [°C]
-40 20 40 60 80 100 110
100
90
80
70
60
50
40
30
20
10
0
Output Power [%]
Ambient Temperature [°C]
Nature Convection (0.1m/s)
0.2m/s
0.5m/s
1.0m/s
1.5m/s
2.0m/s
83.7
-40 20 40 60 80 100 110
100
90
80
70
60
50
40
30
20
10
0
Output Power [%]
Ambient Temperature [°C]
Nature Convection (0.1m/s)
0.2m/s
0.5m/s
1.0m/s
1.5m/s
2.0m/s
85.9
RPA30-2405SAW RPA30-2405SAW-HC
Thermal Calculation
Table 1: Thermal Impedance
without Heatsink with Heatsink
airflow
[m/s]
Rth without PCB
[°C/W]
Rth with PCB (6)
[°C/W]
Rth without PCB
[°C/W]
Rth with PCB (6)
[°C/W]
0.1 17.8 12.5 16.0 11.3
0.2 16.0 11.2 14.4 10.1
0.5 14.0 9.7 12.6 8.7
1.0 10.0 7.1 9.0 6.4
1.5 8.3 5.8 7.5 5.2
2.0 6.3 4.4 5.7 4.0
Iout = 50%
Rth = 9.7°C/W
PDISS = 2.2W
TCASEmax = 105°C
Iout = 50%
Rth = 8.7°C/W
PDISS = 2.2W
TCASEmax = 105°C
choose your model:
RPA30-2405SAW (with PCB (6) )
• Load conditions in application (e.g. 50%)
Airflow conditions in application (e.g. 0.5m/s)
• use Rth from Table1 (9.7°C/W)
Calculation:
choose your model:
RPA30-2405SAW-HC (with PCB (6) )
• Load conditions in application (e.g. 50%)
Airflow conditions in application (e.g. 0.5m/s)
• use Rth from Table1 (8.7°C/W)
Calculation:
TAMBmax = TCASEmax - TOVER = 105°C - 21.3°C = 83.7°C TAMBmax = TCASEmax - TOVER = 105°C - 19.1°C = 85.9°C
TOVER = Rth x PDis = 9.7°C/W x 2.2W = 21.3°C TOVER = Rth x PDis = 8.7°C/W x 2.2W = 19.1°C
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E224736-A39 + A40 UL60950-1, 2nd Edition, 2014
IEC/EN Information Technology Equipment - General Requirments for
Safety (CB Scheme) E224736-A39-CB + A40-CB
IEC60950-1, 2nd Edition, 2005 + AM2, 2013
Railway Applications - Electrical Equipment used on rolling stock 15100175 001, 15100176 001 EN50155, 1st Edition, 2007, Clause 5.4 and 5.5
RoHs 2+
continued on next page
Notes:
Note6: Test PCB:160x100mm105µm (Eurocard), double layer
EMC Compliance (designed to meet)
Condition
Standard / Criterion
Information technology equipment - Radio disturbance characteristics Limits and
methods of measurement with external filter EN55022, Class A, 2010
Railway applications - Electromagnetic compatibility Part 3-2: Rolling stock
- Apparatus EN50121-3-2, 2015
Specification for radio disturbance and immunity measuring apparatus and
methods Part 2-1: Methods of measurement of disturbances and immunity –
Conducted disturbance measurements
EN55016-2-1, 2009
Specification for radio disturbance and immunity measuring apparatus and
methods Part 2-3: Methods of measurement of disturbances and immunity –
Radiated disturbance measurements
EN55016-2-3, 2010
ESD Electrostatic discharge immunity test Air ±8kV, Contact ±6kV EN61000-4-2, 2009; Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
20V/m, 80-1000MHz
10V/m, 1.4-2.0GHz
5V/m, 2.0-2.7GHz
3V/m, 5.1-6.0GHz
EN61000-4-3, 2006; Criteria A
Fast Transient and Burst Immunity ±2kV IEC61000-4-4, 2004; Criteria A
Surge Immunity ±1kV EN61000-4-5, 2006; Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields 10V EN61000-4-6, 2009; Criteria A
DC/DC Converter
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted
RPA30-AW
Series
PD-7
REV.: 5/2018www.recom-power.com
C1 L1
47µF/50V
electrolytic capacitor 1µH Choke
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
Case
Baseplate
Potting
Al Alloy, anodize black
non-conductive FR4
Silicone
Package Dimensions (LxWxH) without Heat-sink
with Heat-sink
25.4 x 25.4 x 10.2mm
25.4 x 25.4 x 16.8mm
Package Weight without Heat-sink
with Heat-sink
17g typ.
21g typ.
continued next page
Fuse
C1D17
+VIN
-VIN
L1
LOADLOAD
EMI Filtering according to EN50121-3-2 and EN55022 Class A
Notes:
Note7: Diode is only needed for EN50155.
PD-8 REV.: 5/2018 www.recom-power.com
DC/DC Converter
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted
RPA30-AW
Series
Heat-sink Dimension Drawing (mm)
16.8
25.4
25.4
25.4
Bottom View
Top View
Top View
Heat-sink
recommended Layout:
1
1
2
2
3
3
4
4
55
6
6
20.32
10.16 10.2
25.4
25.4
5.08
6.0
2.54
2.54
2.54
12.7
10.16
Ø 1.0
6 x Ø1.5
16.8
25.4
25.4
25.4
Bottom View
Top View
Top View
Heat-sink
recommended Layout:
1
1
2
2
3
3
4
4
55
6
6
20.32
10.16 10.2
25.4
25.4
5.08
6.0
2.54
2.54
2.54
12.7
10.16
Ø 1.0
6 x Ø1.5
Dimension Drawing (mm)
Pin Connections
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
3 CTRL(2) CTRL(2)
4 -Vout -Vout
5 Trim Com
6 +Vout +Vout
Pin Pitch Tolerance ±0.25mm
Pin dimension tolerance ±0.1mm
XX.X ± 0.5mm
XX.XX ± 0.25mm
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimensions (LxWxH) without Heat-sink
with Heat-sink tube 285.0 x 27.6 x 19.0mm
285.0 x 27.6 x 25.8mm
Packaging Quantity 10pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 5% - 95% RH
DC/DC Converter
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted
RPA30-AW
Series
PD-9
REV.: 5/2018www.recom-power.com
The
product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products
are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss
of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.