All Sensors DS-0102 Rev A
The Miniature Amplified Output pressure sensors is based upon a proprietary technology to reduce all output
offset or common mode errors. This model provides a calibrated amplified output with superior output offset
characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time
period, and position sensitivity are all significantly reduced when compared to conventional compensation
methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to
provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage between
4.5 and 5.5 volts.
Low Pressure (1” H2O to 30 “ H2O) Sensors
PRIME GRADE
• 0 to 1” H2O to 0 to 30” H2O Pressure Ranges
• Matched pressure port volumes
• Temperature Compensated ( -25 to 85° C)
• Calibrated Zero and Span
• Medical Instrumentation
• Environmental Controls
• HVAC
General Description
Applications
Features
Miniature Amplified Low Pressure Sensors
Physical Dimensions
0.10
Typical
(2.54)
Pin 1 2 3 4
0.62
(15.7)
0.50
(12.7)
0.30
(7.6)
0.080 O.D.
(2.00)
0.380
B-port
A-port
Equivalent Circuit
D1 version D2 version
or G verison
Miniature Amplified Low Pressure Sensors
Part Number
1 INCH-Dx-P4V-MINI
1 INCH-G-P4V-MINI
5 INCH-Dx-P4V-MINI
5 INCH-G-P4V-MINI
10 INCH-Dx-P4V-MINI
10 INCH-G-P4V-MINI
20 INCH-Dx-P4V-MINI
20 INCH-G-P4V-MINI
30 INCH-Dx-P4V-MINI
30 INCH-G-P4V-MINI
60 INCH-Dx-P4V-MINI
Operating Pressure
±1 In H2O
0 - 1 In H2O
± 5 In H2O
0 - 5 In H2O
±10 In H2O
0 - 10 In H2O
±20 In H2O
0 - 20 In H2O
±30 In H2O
0 - 30 In H2O
±60 In H2O
Nominal Span
4 V
4 V
4 V
4 V
4 V
4 V
4 V
4 V
4 V
4 V
4V
Proof Pressure
100 In H2O
300 In H2O
200 In H2O
200 In H2O
200 In H2O
200 In H2O
300 In H2O
300 In H2O
500 In H2O
500 In H2O
500 In H2O
Burst Pressure
200 In H2O
200 In H2O
300 In H2O
300 In H2O
300 In H2O
300 In H2O
500 In H2O
500 In H2O
800 In H2O
800 In H2O
800 In H2O
Standard Pressure Ranges
Supply Supply Voltage VS
Common-mode pressure
Lead Temperature
(soldering 2-4 sec.)
+4.5 to +5.5
Vdc
10 psig
250°C
Pressure Sensor Characteristics Maximum Ratings
Temperature Ranges
Compensated
Operating
Storage
Humidity Limits
-25 to 85° C
-40 to 125° C
-40 to 125° C
0 to 95% RH
(non condensing)
Environmental Specifications
Equivalent Circuit
For differential pressure D1 is the package with two pressure ports the same side, D2 has two ports the opposite sides.
a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 f 408 225 2079 e www.allsensors.com all sensorsall sensors
all sensorsall sensors
all sensors
All Sensors DS-0102 Rev A
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (-25°C-85°C), note 2
Minimum
±1.90
2.15
Nominal
±1.0
±2.0
2.25
±10
±5
±10
0.05
Maximum
±2.10
2.35
±60
0.25
±2
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Parameter, note 1
Operating Range, gage pressure
Output Span, note 5
Offset Voltage @ zero pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (5°C-50°C), note 2
Minimum
3.90
0.15
Nominal
1.0
4.0
0.25
±10
±15
±10
0.05
Maximum
4.10
0.35
±60
0.25
±2
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (-25°C-85°C), note 2
Minimum
±1.90
2.15
Nominal
±5.0
±2.0
2.25
±5
±5
±5
0.05
Maximum
±2.10
2.35
±40
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Performance Characteristics for 1 INCH-Dx-P4V-MINI
Performance Characteristics for 1 INCH-G-P4V-MINI
Performance Characteristics for 5 INCH-Dx-P4V-MINI
Miniature Amplified Low Pressure Sensors
Parameter, NOTE 1
Operating Range, gage pressure
Output Span, NOTE 5
Offset Voltage @ zero pressure
Offset Temperature Shift (-25°C-85°C), NOTE 2
Offset Warm-up Shift, NOTE 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, NOTE 4
Span Shift (-25°C-85°C), NOTE 2
Minimum
3.90
0.15
Nominal
5.0
4.0
0.25
±5
±5
±5
0.05
Maximum
4.10
0.35
±40
0.25
±1
Units
mbar
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Parameter, NOTE 1
Operating Range, differential pressure
Output Span, NOTE 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C-85°C), NOTE 2
Offset Warm-up Shift, NOTE 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, NOTE 4
Span Shift (-25°C-85°C), NOTE 2
Minimum
±1.90
2.15
Nominal
±10.0
±2.0
2.25
±5
±5
±5
0.05
Maximum
±2.10
2.35
±20
0.25
±1
Units
mbar
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Parameter, NOTE 1
Operating Range, gage pressure
Output Span, NOTE 5
Offset Voltage @ zero pressure
Offset Temperature Shift (-25°C-85°C), NOTE 2
Offset Warm-up Shift, NOTE 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, NOTE 4
Span Shift (-25°C-85°C), NOTE 2
Minimum
3.90
0.15
Nominal
10.0
4.0
0.25
±5
±5
±5
0.05
Maximum
4.10
0.35
±20
0.25
±1
Units
mbar
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Performance Characteristics for: 5 INCH-G-P4V-MINI
Performance Characteristics for: 10 INCH-Dx-P4V-MINI
Performance Characteristics for: 10 INCH-G-P4V-MINI
a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 f 408 225 2079 e www.allsensors.com all sensorsall sensors
all sensorsall sensors
all sensors
All Sensors DS-0102 Rev A
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (-25°C-85°C), note 2
Minimum
±1.90
2.15
Nominal
±20.0
±2.0
2.25
±5
±5
±5
0.05
Maximum
±2.10
2.35
±20
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Parameter, note 1
Operating Range, gage pressure
Output Span, note 5
Offset Voltage @ zero pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (-25°C-85°C), note 2
Minimum
3.90
0.15
Nominal
20.0
4.0
0.25
±5
±5
±5
0.05
Maximum
4.1
0.35
±20
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (-25°C-85°C), note 2
Minimum
±1.90
2.15
Nominal
±30.0
±2.0
2.25
±5
±5
±5
0.05
Maximum
±2.10
2.35
±20
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Performance Characteristics for 20 INCH-Dx-P4V-MINI
Performance Characteristics for 20 INCH-G-P4V-MINI
Performance Characteristics for 30 INCH-Dx-P4V-MINI
Miniature Amplified Low Pressure Sensors
Specification Notes
NOTE 1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE FRONT PORT.
NOTE 2: SHIFT IS RELATIVE TO 25°C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS
FOR MINUS TO PLUS FULL SCALE PRESSURE.
Parameter, NOTE 1
Operating Range, gage pressure
Output Span, NOTE 5
Offset Voltage @ zero pressure
Offset Temperature Shift (-25°C-85°C), NOTE 2
Offset Warm-up Shift, NOTE 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, NOTE 4
Span Shift (-25°C-85°C), NOTE 2
Minimum
3.9
0.15
Nominal
30.0
4.0
0.25
±5
±5
±5
0.05
Maximum
4.1
0.35
±20
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is
typically less than 100 useconds.
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (-25°C-85°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Span Shift (-25°C-85°C), note 2
Minimum
±1.90
2.15
Nominal
±60.0
±2.0
2.25
±5
±5
±5
0.05
Maximum
±2.10
2.35
±20
0.25
±1
Units
“H2O
volt
volt
mvolt
mvolt
mvolt
mvolt
%fs
%span
Performance Characteristics for 30 INCH-G-P4V-MINI
Performance Characteristics for 60 INCH-Dx-P4V-MINI