Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes Data Sheet 02 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Key Features Measurement Versatility Measurement versatility These probes integrate many of the features and characteristics needed for today's general-purpose, high-speed differential probing - especially in digital system design, component design/ characterization, and differential serial bus measurements. The N2750A Series differential probes offer 2:1 and 10:1 dual attenuation settings, allowing them to be used for a broad range of applications. Dual attenuation range is automatically configured depending on the size of the input signal. -- 1.5 GHz, 3.5 GHz, and 6 GHz probe bandwidth models -- Dual attenuation ratio (2:1/10:1) -- High input resistance (200 k differential, 100 k single-ended) -- Wide input dynamic range (10 Vpp) -- Wide offset range ( 15 V) -- High CMRR (>60 dB at 1 MHz) Superb usability -- InfiniiMode probing for making differential, single-ended and common mode measurements with a single probe -- Built-in multi-function scope control for quick access to a variety of scope functions -- Built-in "Headlight" to see where you are probing -- Includes solder-in, browser, and socketed tips standard -- AutoProbe interface for auto configuration and probe power At affordable prices The N2750A Series InfiniiMode differential probes are a new generation of low-cost, 1.5 GHz, 3.5 GHz, and 6 GHz differential active probes compatible with the Keysight Technologies, Inc. InfiniiVision and Infiniium oscilloscopes' AutoProbe interface. The new differential probes have an input resistance of 200 k (differential) or 100 k (each input to ground) and an extremely low input capacitance of 700 fF to minimize circuit loading. This, accompanied with superior signal fidelity, makes these probes useful for most digital design and debug applications. And with their wide dynamic range (10 Vpp) and offset range ( 15 V), these probes can be used in a wide variety of analog signal measurements as well. 03 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Superb Usability InfiniiMode The N2750A Series probes come with new InfiniiMode operation modes. The InfiniiMode allows convenient measurements of differential, single-ended, and common mode signals with a single probe tip without reconnecting the probe to change the connection. The N2750A probe's InfiniiMode provides the following modes of operation. -- A - B (differential) -- A - ground (single-ended A) -- B - ground (single-ended B) -- (A+B)/2 - ground (common mode) Figure 1. The InfiniiMode allows convenient measurements of differential, single-ended (A, B), and common mode signals with a single probe tip without reconnecting the probe to change the connection. Quick action scope control The N2750A Series differential probes provide convenient and quick access to various functions on the scope. You often have a need to control the scope while you hold a probe in your hand. With the quick action scope control feature built into the probe, you can turn the built-in headlight of the probe on and off, or control some frequently used scope functions such as RUN/STOP, auto scale, quick print, quick save, etc. with only a button press on the probe. Get control of your most needed function with a push of the quick action control button on the probe. The following scope functions can be controlled with the quick action control button. For Infiniium oscilloscopes: -- Headlight on-off/intensity control -- InfiniiMode -- Run/stop toggle -- Single -- Clear display -- Autoscale -- No action -- Multipurpose (mapped to quick action button) -- Quick Measure -- Quick Print -- Quick Screen -- Quick Setup -- Quick Waveform -- Quick Email -- Quick Execute -- Quick Control For InfiniiVision oscilloscopes: -- Headlight on-off/intensity control -- InfiniiMode -- Run/stop toggle -- Single -- Clear display -- Autoscale -- Force trigger -- Quick action (mapped to quick action button) -- Quick measure all -- Quick measure statistics reset -- Quick mask statistics reset -- Quick print -- Quick save -- Quick e-mail -- Quick recall -- Quick freeze display -- Quick trigger mode -- Quick clear display 04 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Flexibility in probe use models is also a vital necessity. The probes come standard with three different types of exchangeable probe tips that allow for easy connections to the circuit under test. These probe tips enable you to access multiple signals on anything from header connectors to hard-to-reach, high-density circuitry. The probes are equipped with a white LED headlight to illuminate the circuit under test which will help you see where you are probing. The probes are powered directly by the AutoProbe interface, eliminating the need for an additional power supply. The AutoProbe interface also automatically identifies the probe type for auto configuration of the probe. Browser tip Solder-in tip Socketed tip Maximum bandwidth Up to 6 GHz warranted, 7 GHz typical (with N2752A) Up to 3.5 GHz (with N2751A) Up to 1.5 GHz (with N2750A) Up to 2.5 GHz (with N2751A/52A) Up to 1.5 GHz (with N2750A) Up to 3 GHz (with N2751A/52A) Up to 1.5 GHz (with N2750A) InfiniiMode No Yes Yes Key features Adjustable pitch spacing (0.5 mm - 7.5 mm), full bandwidth, differential mode only, head light, damping R tip Damping R tip Damping R tip Applications Highest performance (7 GHz), quick and simple hand browsing For soldering tips directly to test devices, semi-permanent DUT signals, differential signals where SE and common modes need to be investigated For directly connecting to 0.1" header pins Replacement part number N2776A (qty 3)* N2777A (qty 3)* N2778A (qty 3)* * Comes with two each solder-in, socketed and browser tips per each probe. 05 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Figure 2. N2750A Series differential probe with browser tip Figure 4. With InfiniiMode solder-in tip Figure 3. With InfiniiMode socketed tip 06 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Figure 5. Vout/Vin frequency response of N2752A (at 2:1) with browser tip Figure 6. Loading effect of N2752A (at 2:1) with browser tip Figure 7. Time domain response to a 136 psec step of N2752A (at 2:1) with browser tip 07 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Figure 8. Input impedance over frequency of N2752A Figure 9. Common mode rejection ratio of N2752A (red: 2:1, blue: 10:1) 08 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Characteristics and specifications Model number N2750A N2751A N2752A Probe bandwidth* (-3 dB) 1.5 GHz 3.5 GHz 6 GHz (warranted), 7 GHz (typical) Rise time, probe only (10-90%) 233 psec 100 psec 58.3 psec System bandwidth (with Keysight oscilloscope) 1 GHz (with Keysight's 1 GHz Infiniium/InfiniiVision oscilloscope) 2.5 GHz (with Keysight's 2.5 GHz Infiniium oscilloscope) 4/6 GHz (with Keysight's 4/6 GHz Infiniium oscilloscope) Input resistance (@DC)* 200 k 2 % (differential mode) 100 k 2 % (single-ended mode) 50 k 2 % (common mode) Input capacitance 700 fF (with browser) Attenuation ratio (@DC) 2:1/10:1 Input dynamic range 1 V, 2 Vpp (@2:1)/ V, 10 Vpp (@10:1) Input common mode range 15 V (from DC to 100 Hz), 2.5 V (for >100 Hz)**** Offset range 15 V Offset accuracy** <3% Maximum non-destructive input voltage 30 V (DC + peak AC) * ** *** **** Denotes warranted electrical specifications at 2:1 attenuation mode after 20 minute warm-up, All others are typical. When calibrated on the oscilloscope, these characteristics are determined by the oscilloscope characteristics. The N2750A Series differential probes can be used with the Infiniium 90000X/Q Series scope and the N5442A precision BNC adapter. Assumes symmetric differential signals. 09 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Characteristics and specifications Model number N2750A N2751A Differential mode rejection ratio 40 dB at 1 MHz 40 dB at 30 MHz 30 dB at 1 GHz Channel isolation, at single-ended mode 60 dB at 1 MHz 45 dB at 30 MHz 20 dB at 1 GHz Offset gain accuracy < 3 % before calibration < 1 % after calibration Noise referred to input 2.5 mVrms (@2:1), 7 mVrms (@10:1) Maximum signal slew rate 30 V/ns (differential, 10x), 15 V/ns (single-ended, 10x) Zero offset error referred to input < 30 mV before calibration scope, < 5 mV after calibration scope Propagation delay 6.85 nsec ESD tolerance > 8 kV from 100 pF, 300 , HBM Output impedance 50 Cable length 1.3 m Probe weight 100 g Ambient operating temperature 0 to +40 C Ambient non-operating temperature -40 to +70 C Operating humidity Up to 95 % RH @ +40 C Non-operating humidity Up to 90 % RH @ +65 C Operating altitude 4,600 m Non-operating altitude EMC/EMI N2752A 15,300 m Radiated Emission: CISPER 11 Group 1, Class A. ESD: IEC61000-4-2 4KV contact discharge, 8KV air discharge Standard accessories 2x InfiniiMode solder-in tips 1x InfiniiMode socketed tip 1x Differential browser tip Others (included) 1x calibration certificate 1x accessory configuration card Standard warranty 1 year (extended warranty available at cost) Recommended Keysight oscilloscopes*** * ** *** **** InfiniiVision 3000 X-Series with software ver 2.2 or higher, 4000 X-Series with 3.01 or higher, 6000 X-Series with 6.0 or higher, Infiniium 9000 Series with 3.5 or higher, S-Series with 5.0 or higher Infiniium 9000 and 90000A Series with software ver 3.5 or higher, S-Series with 5.0 or higher Infiniium 9000 and 90000A Series with software ver 3.5 or higher, S-Series with 5.0 or higher Denotes warranted electrical specifications at 2:1 attenuation mode after 20 minute warm-up, All others are typical. When calibrated on the oscilloscope, these characteristics are determined by the oscilloscope characteristics. The N2750A Series differential probes can be used with the Infiniium 90000X/Q Series scope and the N5442A precision BNC adapter. Assumes symmetric differential signals. 10 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Ordering information Model number Description N2750A 1.5 GHz InfiniiMode differential probe N2751A 3.5 GHz InfiniiMode differential probe N2752A 6 GHz InfiniiMode differential probe N2776A Differential browser tips (qty 3)* N2777A InfiniiMode solder-in tips (qty 3)* N2778A InfiniiMode socketed tips (qty 3)* N4822A Socketed tip for USB/ethernet application fixtures (not included in the standard probe kit) * Comes with two each solder-in, socketed and browser tips per each probe. Other recommended accessories Model number Description N2787A 3D probe positioner E2655C Performance verification and deskew fixture N5442A Precision BNC adapter for 90000X/Q Series oscilloscopes Publication title Publication type Publication number Keysight Oscilloscope Probes and Accessories Selection Guide 5989-6162EN Infiniium Oscilloscope Probes and Accessories Data Sheet 5968-7141EN 8 Hints for Better Scope Probing Application Note 5989-7894EN Oscilloscope Probing for High-Speed Signals Application Note 5989-9177EN Performance Comparison of Differential and Single-ended Active Voltage Probes Application Note 5988-8006EN Improving Usability and Performance in High-Bandwidth Active Oscilloscope Probes Application Note 5988-8005EN Optimizing Oscilloscope Measurement Accuracy on High-Performance Systems with Keysight Active Probes Application Note 5988-5021EN Restoring Confidence in Your High-Bandwidth Probe Measurements Application Note 5988-7951EN The Truth About the Fidelity of High-Bandwidth Voltage Probes Application Note 5988-6515EN Extending the Range of Keysight InfiniiMax Probes Application Note 5989-7587EN Understanding and Using Offset in InfiniiMax Active Probes Application Note 5988-9264EN Tips for Making Low Current Measurements with an Oscilloscope and Current Probe Application Note 5989-7529EN Using Keysight InfiniiMax Probes with Test Equipment Other Than Oscilloscopes Application Note 5989-1869EN Why Oscilloscope Measurements may Require Extreme Probing Application Note 5990-4721EN Side by Side Comparison of Keysight and Tektronix Probing Application Note 5989-0553EN Tips and Techniques for Making Power Supply Noise Measurements with an Oscilloscope Application Note 5989-6755EN Time-Domain Response of Keysight InfiniiMax Probes Application Note 5988-9608EN How Offset, Dynamic Range and Compression Affect Measurements Application Note 5990-8255EN Keysight InfiniiMax Probes Impact on Lead-Free (ROHS) Compliance Application Note 5989-5179EN 11 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet Keysight Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications 12 | Keysight | N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA(R) Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA(R), AdvancedTCA(R), and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight's commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight's measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/InfiniiMode For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-23-14) This information is subject to change without notice. (c) Keysight Technologies, 2012 - 2014 Published in USA, December 9, 2014 5991-0560EN www.keysight.com