June 2006 Rev 6 1/25
25
M41T00
Serial real-time clock
Features summary
Counters for seconds, minutes, hours,day,
month, years, and century
32kHz crystal oscillator integrating load
capacitance (12.5pF) providing exceptional
oscillator stability and high crystal series
resistance operation
Serial interface supports I2C bus (100kHz
protocol)
Ultra low battery supply current of 0.8µA
(typ@3V)
2.0 to 5.5V clock operating voltage
Automatic switch-over and deselect circuitry
(for 3V application select M41T00S datasheet)
Software clock calibration to compensate
crystal deviation due to temperature
Automatic leap year compensation
Operating temperature of -40 to 85°C
SO8(M)
8-pin SOIC
8
1
www.st.com
Contents M41T00
2/25
Contents
1 Summary description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Pin settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Pin connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Pin description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 Wire bus characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Bus not busy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.3 Start data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.4 Stop data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.5 Data valid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.6 Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.7 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.8 Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.9 Write mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.10 Data retention mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5 M41T00 clock operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.1 Clock calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.2 Output driver pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.3 Initial power-on defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
M41T00 Contents
3/25
9 Order codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
10 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Summary description M41T00
4/25
1 Summary description
The M41T00 is a low power serial real time clock with a built-in 32.768kHz oscillator
(external crystal controlled). Eight bytes of the RAM are used for the clock/calendar function
and are configured in binary coded decimal (BCD) format. Addresses and data are
transferred serially via a two-line bi-directional bus. The built-in address register is
incremented automatically after each WRITE or READ data byte.
The M41T00 clock has a built-in power sense circuit which detects power failures and
automatically switches to the battery supply during power failures. The energy needed to
sustain the RAM and clock operations can be supplied from a small lithium coin cell.
Typical data retention time is in excess of 5 years with a 50mA/h 3V lithium cell (see
Section 4.10: Data retention mode for AC/DC Characteristics). The M41T00 is supplied in 8
lead plastic small outline package.
Figure 1. Logic symbol
AI00530
OSCI
VCC
M41T00
VSS
SCL
OSCO
SDA
FT/OUT
VBAT
M41T00 Pin settings
5/25
2 Pin settings
2.1 Pin connection
Figure 2. SOIC connection
2.2 Pin description
1
SDAVSS
SCL
FT/OUTOSCO
OSCI VCC
VBAT
AI00531
M41T00
2
3
4
8
7
6
5
Table 1. Pin description
Symbol Name and function
OSCI Oscillator input
OSCO Oscillator output
FT/OUT Frequency test / output driver (open drain)
SCL Serial clock
SDA Serial data address input/output
VBAT Battery supply voltage
AIN Audio input
VSS Ground
VCC Supply voltage
Block diagram M41T00
6/25
3 Block diagram
Figure 3. Block diagram
AI00603
SECONDS
OSCILLATOR
32.768 kHz
VOLTAGE
SENSE and
SWITCH
CIRCUITRY
SERIAL
BUS
INTERFACE
DIVIDER
CONTROL
LOGIC
ADDRESS
REGISTER
MINUTES
CENTURY/HOURS
DAY
DATE
MONTH
YEAR
CONTROL
OSCI
OSCO
FT/OUT
VCC
VSS
VBAT
SCL
SDA
1 Hz
M41T00 Operation
7/25
4 Operation
The M41T00 clock operates as a slave device on the serial bus. Access is obtained by
implementing a start condition followed by the correct slave address (D0h). The 8 bytes
contained in the device can then be accessed sequentially in the following order:
1. Seconds register
2. Minutes register
3. Century/hours register
4. Day register
5. Date register
6. Month register
7. Years register
8. Control register
The M41T00 clock continually monitors VCC for an out of tolerance condition. Should VCC
fall below VSO, the device terminates an access in progress and resets the device address
counter. Inputs to the device will not be recognized at this time to prevent erroneous data
from being written to the device from an out of tolerance system. When VCC falls below VSO,
the device automatically switches over to the battery and powers down into an ultra low
current mode of operation to conserve battery life. Upon power-up, the device switches from
battery to VCC at VSO and recognizes inputs.
4.1 Wire bus characteristics
This bus is intended for communication between different ICs. It consists of two lines: one
bi-directional for data signals (SDA) and one for clock signals (SCL). Both the SDA and the
SCL lines must be connected to a positive supply voltage via a pull-up resistor.
The following protocol has been defined:
Data transfer may be initiated only when the bus is not busy.
During data transfer, the data line must remain stable whenever the clock line is High.
Changes in the data line while the clock line is High will be interpreted as control
signals.
Accordingly, the following bus conditions have been defined:
Operation M41T00
8/25
4.2 Bus not busy
Both data and clock lines remain high.
4.3 Start data transfer
A change in the state of the data line, from high to low, while the clock is high, defines the
START condition.
4.4 Stop data transfer
A change in the state of the data line, from low to high, while the clock is high, defines the
STOP condition.
4.5 Data valid
The state of the data line represents valid data when after a start condition, the data line is
stable for the duration of the High period of the clock signal. The data on the line may be
changed during the Low period of the clock signal. There is one clock pulse per bit of data.
Each data transfer is initiated with a start condition and terminated with a stop condition.
The number of data bytes transferred between the start and stop conditions is not limited.
The information is transmitted byte-wide and each receiver acknowledges with a ninth bit.
By definition, a device that gives out a message is called “transmitter”, the receiving device
that gets the message is called “receiver”. The device that controls the message is called
“master”. The devices that are controlled by the master are called “slaves”.
4.6 Acknowledge
Each byte of eight bits is followed by one acknowledge bit. This acknowledge bit is a low
level put on the bus by the receiver, whereas the master generates an extra acknowledge
related clock pulse.
A slave receiver which is addressed is obliged to generate an acknowledge after the
reception of each byte. Also, a master receiver must generate an acknowledge after the
reception of each byte that has been clocked out of the slave transmitter.
The device that acknowledges has to pull down the SDA line during the acknowledge clock
pulse in such a way that the SDA line is a stable low during the high period of the
acknowledge related clock pulse. Of course, setup and hold times must be taken into
account. A master receiver must signal an end-of-data to the slave transmitter by not
generating an acknowledge on the last byte that has been clocked out of the slave. In this
M41T00 Operation
9/25
case, the transmitter must leave the data line High to enable the master to generate the
STOP condition.
Figure 6. Bus timing requirements sequence
Note: P = STOP and S = START
Figure 4. Serial bus data transfer sequence
Figure 5. Acknowledgement sequence
AI00587
DATA
CLOCK
DATA LINE
STABLE
DATA VALID
START
CONDITION
CHANGE OF
DATA ALLOWED
STOP
CONDITION
AI00601
DATA OUTPUT
BY RECEIVER
DATA OUTPUT
BY TRANSMITTER
SCLK FROM
MASTER
START
CLOCK PULSE FOR
ACKNOWLEDGEMENT
12 89
MSB LSB
AI00589
SDA
P
tSU:STOtSU:STA
tHD:STA
SR
SCL
tSU:DAT
tF
tHD:DAT
tR
tHIGH
tLOW
tHD:STAtBUF
SP
Operation M41T00
10/25
4.7 Characteristics
4.8 Read mode
In this mode, the master reads the M41T00 slave after setting the slave address (see
Figure 7). Following the WRITE Mode Control Bit (R/W = 0) and the acknowledge bit, the
word address An is written to the on-chip address pointer. Next the START condition and
slave address are repeated, followed by the read mode control bit (R/W = 1). At this point,
the master transmitter becomes the master receiver. The data byte which was addressed
will be transmitted and the master receiver will send an acknowledge bit to the slave
transmitter. The address pointer is only incremented on reception of an acknowledge bit.
The M41T00 slave transmitter will now place the data byte at address An+1 on the bus. The
master receiver reads and acknowledges the new byte and the address pointer is
incremented to An+2.
This cycle of reading consecutive addresses will continue until the master receiver sends a
STOP condition to the slave transmitter.
Table 2. AC characteristics
Symbol Parameter(1)
1. Valid for ambient operating temperature: TA = -40 to 85°C; VCC = 2.0 to 5.5V (except where noted).
Min Typ Max Units
fSCL SCL clock frequency 0 100 kHz
tLOW Clock low period 4.7 µs
tHIGH Clock high period s
tR SDA and SCL rise time s
tF SDA and SCL fall time 300 ns
tHD:STA START condition hold time
(after this period the first clock pulse is generated) s
tSU:STA START condition setup time
(only relevant for a repeated start condition) 4.7 µs
tHD:DAT(2)
2. Transmitter must internally provide a hold time to bridge the undefined region (300ns max) of the falling
edge of SCL.
Data hold time 0 ns
tSU:DAT Data setup time 250 ns
tSU:STO STOP condition setup time 4.7 µs
tBUF Time the bus must be free before a new
transmission can start 4.7 µs
M41T00 Operation
11/25
An alternate READ Mode may also be implemented, whereby the master reads the M41T00
slave without first writing to the (volatile) address pointer. The first address that is read is the
last one stored in the pointer.
Figure 7. Slave address location
Figure 8. READ mode sequence
Figure 9. Alternate READ mode sequence
AI00602
R/W
SLAVE ADDRESS
START A
0100011
MSB
LSB
AI00899
BUS ACTIVITY:
ACK
S
ACK
ACK
ACK
NO ACK STOP
START
P
SDA LINE
BUS ACTIVITY:
MASTER
R/W
DATA n DATA n+1
DATA n+X
WORD
ADDRESS (An)
SLAVE
ADDRESS
S
START
R/W
SLAVE
ADDRESS
ACK
AI00895
BUS ACTIVITY:
ACK
S
ACK
ACK
ACK
NO ACK STOP
START
PSDA LINE
BUS ACTIVITY:
MASTER
R/W
DATA n DATA n+1 DATA n+X
SLAVE
ADDRESS
Operation M41T00
12/25
4.9 Write mode
In this mode the master transmitter transmits to the M41T00 slave receiver. Bus protocol is
shown in Figure 10. Following the START condition and slave address, a logic '0' (R/W = 0)
is placed on the bus and indicates to the addressed device that word address An will follow
and is to be written to the on-chip address pointer. The data word to be written to the
memory is strobed in next and the internal address pointer is incremented to the next
memory location within the RAM on the reception of an acknowledge clock. The M41T00
slave receiver will send an acknowledge clock to the master transmitter after it has received
the slave address and again after it has received the word address and each data byte (see
Figure 7).
4.10 Data retention mode
With valid VCC applied, the M41T00 can be accessed as described above with READ or
WRITE cycles. Should the supply voltage decay, the M41T00 will automatically deselect,
write protecting itself when VCC falls (see Figure 11).
Figure 11. Power down/up mode ac waveforms
Figure 10. WRITE mode sequence
AI00591
BUS ACTIVITY:
ACK
S
ACK
ACK
ACK
ACK STOP
START
PSDA LINE
BUS ACTIVITY:
MASTER
R/W
DATA n DATA n+1 DATA n+X
WORD
ADDRESS (An)
SLAVE
ADDRESS
AI00596
VCC
tREC
tPD
VSO
SDA
SCL DON'T CARE
M41T00 Operation
13/25
Table 3. RTC power down/up AC characteristics
Symbol Parameter (1) (2)
1. Valid for ambient operating temperature: TA = -40 to 85°C; VCC = 2.0 to 5.5V (except where otherwise
noted).
2. VCC fall time should not exceed 5mV/µs.
Min Typ Max Unit
tPD SCL and SDA at VIH before power down 0 ns
trec SCL and SDA at VIH after power up 10 µs
Table 4. RTC power down/up trip points DC characteristics
Symbol Parameter (1) (2)
1. Valid for ambient operating temperature: TA = -40 to 85°C; VCC = 2.0 to 5.5V (except where otherwise
noted).
2. All voltages referenced to VSS.
Min Typ Max(3)
3. In 3.3V application, if initial battery voltage is > 3.4V, it may be necessary to reduce battery voltage (i.e.,
through wave soldering the battery) in order to avoid inadvertent switchover/deselection for VCC -10%
operation.
Unit
VSO(4)
4. Switch-over and deselect point.
Back-up switchover voltage VBAT -0.80 VBAT -0.50 VBAT -0.30 V
M41T00 clock operation M41T00
14/25
5 M41T00 clock operation
The eight byte clock register (see Ta bl e 5 ) is used to both set the clock and to read the date
and time from the clock, in a binary coded decimal format. Seconds, minutes, and hours are
contained within the first three registers. Bits D6 and D7 of clock register 2 (century/hours
register) contain the century enable bit (CEB) and the century bit (CB). Setting CEB to a '1'
will cause CB to toggle, either from '0' to '1' or from '1' to '0' at the turn of the century
(depending upon its initial state). If CEB is set to a '0', CB will not toggle. Bits D0 through D2
of register 3 contain the day (day of week). Registers 4, 5 and 6 contain the date (day of
month), month and years. The final register is the control register (this is described in the
clock calibration section). Bit D7 of register 0 contains the STOP Bit (ST). Setting this bit to a
'1' will cause the oscillator to stop. If the device is expected to spend a significant amount of
time on the shelf, the oscillator may be stopped to reduce current drain. When reset to a '0'
the oscillator restarts within one second.
Note: In order to guarantee oscillator start-up after the initial power-up, set the ST Bit to a '1,' then
reset this bit to a '0.' This sequence enables a “kick start” circuit which aids the oscillator
start-up during worst case conditions of voltage and temperature.
The seven Clock Registers may be read one byte at a time, or in a sequential block. The
control register (address location 7) may be accessed independently. Provision has been
made to assure that a clock update does not occur while any of the seven clock addresses
are being read. If a clock address is being read, an update of the clock registers will be
delayed by 250ms to allow the read to be completed before the update occurs. This will
prevent a transition of data during the read.
Note: Note: This 250ms delay affects only the clock register update and does not alter the actual
clock time.
M41T00 M41T00 clock operation
15/25
Keys:
S= SIGN Bit
FT = FREQUENCY TEST Bit
ST = STOP Bit
OUT = Output level
X = Don’t care
CEB = Century Enable Bit
CB = Century Bit
Note: When CEB is set to '1', CB will toggle from '0' to '1' or from '1' to '0' at the turn of the century
(dependent upon the initial value set).When CEB is set to '0', CB will not toggle.
5.1 Clock calibration
The M41T00 is driven by a quartz controlled oscillator with a nominal frequency of
32,768Hz. The devices are tested not to exceed 35 ppm (parts per million) oscillator
frequency error at 25°C, which equates to about ±1.53 minutes per month. With the
calibration bits properly set, the accuracy of each M41T00 improves to better than ±2 ppm
at 25°C.
The oscillation rate of any crystal changes with temperature (see Figure 12). Most clock
chips compensate for crystal frequency and temperature shift error with cumbersome trim
capacitors. The M41T00 design, however, employs periodic counter correction. The
calibration circuit adds or subtracts counts from the oscillator divider circuit at the divide by
256 stage, as shown in Figure 13. The number of times pulses are blanked (subtracted,
negative calibration) or split (added, positive calibration) depends upon the value loaded into
the five-bit calibration byte found in the control register. Adding counts speeds the clock up,
subtracting counts slows the clock down.
The calibration byte occupies the five lower order bits (D4-D0) in the control register (addr
7). This byte can be set to represent any value between 0 and 31 in binary form. Bit D5 is a
sign bit; '1' indicates positive calibration, '0' indicates negative calibration. Calibration occurs
Table 5. Register map
Address Data Function/Range
BCD Format
D7 D6 D5 D4 D3 D2 D1 D0
0 ST 10 Seconds Seconds Seconds 00-59
1 X 10 Minutes Minutes Minutes 00-59
2CEB (1) CB 10 Hours Hours Century/Hours 0-1/00-23
3 XXXXX Day Day 01-07
4 X X 10 Date Date Date 01-31
5 X X X 10 M. Month Month 01-12
6 10 Years Years Year 00-99
7 OUT FT S Calibration Control
M41T00 clock operation M41T00
16/25
within a 64minute cycle. The first 62 minutes in the cycle may, once per minute, have one
second either shortened by 128 or lengthened by 256 oscillator cycles. If a binary '1' is
loaded into the register, only the first 2 minutes in the 64 minute cycle will be modified; if a
binary 6 is loaded, the first 12 will be affected, and so on.
Therefore, each calibration step has the effect of adding 512 or subtracting 256 oscillator
cycles for every 125,829,120 actual oscillator cycles, that is +4.068 or –2.034 ppm of
adjustment per calibration step in the calibration register. Assuming that the oscillator is in
fact running at exactly 32,768Hz, each of the 31 increments in the calibration byte would
represent +10.7 or –5.35 seconds per month which corresponds to a total range of +5.5 or –
2.75 minutes per month.
Two methods are available for ascertaining how much calibration a given M41T00 may
require. The first involves simply setting the clock, letting it run for a month and comparing it
to a known accurate reference (like WWV broadcasts). While that may seem crude, it allows
the designer to give the end user the ability to calibrate his clock as his environment may
require, even after the final product is packaged in a non-user serviceable enclosure. All the
designer has to do is provide a simple utility that accessed the calibration byte.
The second approach is better suited to a manufacturing environment, and involves the use
of some test equipment. When the Frequency Test (FT) Bit, the seventh-most significant bit
in the Control Register, is set to a '1', and the oscillator is running at 32,768Hz, the FT/OUT
pin of the device will toggle at 512Hz. Any deviation from 512Hz indicates the degree and
direction of oscillator frequency shift at the test temperature.
For example, a reading of 512.01024Hz would indicate a +20 ppm oscillator frequency error,
requiring a –10(XX001010) to be loaded into the calibration byte for correction. Note that
setting or changing the calibration byte does not affect the frequency test output frequency.
Figure 12. Crystal accuracy across temperature
AI00999b
–160
0 10203040506070
Frequency (ppm)
Temperature °C
80–10–20–30–40
–100
–120
–140
–40
–60
–80
20
0
–20
F= K x (T –TO)2
K = –0.036 ppm/°C2 ± 0.006 ppm/°C2
TO = 25°C ± 5°C
F
M41T00 M41T00 clock operation
17/25
Figure 13. Clock calibration
5.2 Output driver pin
When the FT Bit is not set, the FT/OUT pin becomes an output driver that reflects the
contents of D7 of the control register. In other words, when D6 of address 7 is a zero and D7
of address 7 is a zero and then the FT/OUT pin will be driven low.
Note: The FT/OUT pin is open drain which requires an external pull-up resistor.
5.3 Initial power-on defaults
Upon initial application of power to the device, the FT Bit will be set to a '0' and the OUT Bit
will be set to a '1'. All other Register bits will initially power-on in a random state.
AI00594B
NORMAL
POSITIVE
CALIBRATION
NEGATIVE
CALIBRATION
Maximum ratings M41T00
18/25
6 Maximum ratings
Stressing the device above the rating listed in the "Absolute maximum ratings" table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the operating sections of
this specification is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect device
reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality
documents.
Caution: Negative undershoots below -0.3V are not allowed on any pin while in the back-up mode.
Table 6. Absolute maximum ratings
Symbol Parameter Value Unit
TSTG (1)
1. For SO package, standard (SnPb) lead finish: reflow at peak temperature of 225°C (total thermal budget
not to exceed 180°C for between 90 to 150 seconds).
Storage temperature (VCC off, oscillator off) –55 to 125 °C
TAAmbient operating temperature -40 to 85 °C
VIO Input or output voltages –0.3 to 7 V
VCC Supply voltage –0.3 to 7 V
IO Output current 20 mA
PD Power dissipation 0.25 W
M41T00 DC and AC parameters
19/25
7 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement
Conditions listed in the relevant tables. Designers should check that the operating conditions
in their projects match the measurement conditions when using the quoted parameters.
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 14. AC testing input/output waveform
Table 7. Operating and AC measurement conditions
Parameter M41T00
Supply voltage (VCC) 2.0 to 5.5V
Ambient operating temperature (TA) -40 to 85°C
Load capacitance (CL) 100pF
Input rise and fall times
5ns
Input pulse voltages 0.2VCC to 0.8VCC
Input and output timing reference voltages 0.3VCC to 0.7VCC
Table 8. Capacitance
Symbol Parameter (1) (2)
1. Effective capacitance measured with power supply at 3.3V; sampled only, not 100% tested
2. At 25°C, f= 1MHz
Min Max Unit
CIN Input capacitance (SCL) 7 pF
COUT(3)
3. Outputs deselected
Output capacitance (SDA,FT/OUT) 10 pF
tLP Low-pass filter input time constant (SDA and SCL) 250 1000 ns
AI02568
0.8VCC
0.2VCC
0.7VCC
0.3VCC
DC and AC parameters M41T00
20/25
Table 9. DC characteristics
Symbol Parameter Test condition(1)
1. Valid for ambient operating temperature: TA = -40 to 85°C; VCC = 2.0 to 5.5V (except where otherwise
noted).
Min Typ Max Unit
ILI Input leakage current 0V = VIN = VCC ±1 µA
ILO Output leakage current 0V = VOUT = VCC ±1 µA
ICC1 Supply current Switch frequency =
100kHz 300 µA
ICC2 RTC supply current
(standby) SCL, SDA= VCC – 0.3V 70 µA
VIL Input low voltage –0.3 0.3VCC V
VIH Input high voltage 0.7VCC VCC+0.5 V
VOL Output low voltage IOL = 3.0mA 0.4 V
Output Low Voltage
(Open Drain) FT/OUT 5.5 V
VBAT(2)
2. STMicroelectronics recommends the RAYOVAC BR1225 or BR1632 (or equivalent)as the battery supply.
Battery supply voltage 2.5(3)
3. After switchover (VSO), VBAT(min) can be 2.0V for crystal with RS = 40K..
3.5(4)
4. For rechargeable back-up, VBAT(max) may be considered VCC.
V
IBAT Battery supply current
TA = 25°C, VCC = 0V
oscillator ON,
VBAT = 3V
0.8 1 µA
Table 10. Crystal electrical characteristics
Symbol Parameter (1) (2)
1. Externally supplied if using the SO8 package. STMicroelectronics recommends the KDS DT-38:
1TA/1TC252E127, Tuning Fork Type (thru-hole) or the DMX-26S: 1TJS125FH2A212, (SMD) quartz crystal
for industrial temperature operations. KDS can be contacted at kouhou@kdsj.co.jp or http://www.kdsj.co.jp
for further information on this crystal type.
2. Load capacitors are integrated within the M41T00. Circuit board layout considerations for the 32.768kHz
crystal of minimum trace lengths and isolation from RF generating signals should be taken into account.
Min Typ Max Units
fO Resonant frequency 32.768 kHz
RS Series resistance 60 K
CLLoad capacitance 12.5 pF
M41T00 Package mechanical data
21/25
8 Package mechanical data
In order to meet environmental requirements, ST offers these devices in ECOPACK®
packages. These packages have a Lead-free second level interconnect . The category of
second level interconnect is marked on the package and on the inner box label, in
compliance with JEDEC Standard JESD97. The maximum ratings related to soldering
conditions are also marked on the inner box label. ECOPACK is an ST trademark.
ECOPACK specifications are available at: www.st.com
Package mechanical data M41T00
22/25
Figure 16. DFN16 (5mm x 4mm) package outline
Note: Drawing is not to scale.
Figure 15. SO8 – 8-lead plastic small outline package mechanical data
Symb mm inches
Typ Min Max Typ Min Max
A 1.35 1.75 0.053 0.069
A1 0.10 0.25 0.004 0.010
B 0.33 0.51 0.013 0.020
C 0.19 0.25 0.007 0.010
D 4.80 5.00 0.189 0.197
E 3.80 4.00 0.150 0.157
e1.27– 0.050
H 5.80 6.20 0.228 0.244
h 0.25 0.50 0.010 0.020
L 0.40 0.90 0.016 0.035
a0°8°0°8°
N8 8
CP 0.10 0.004
SO-A
E
8
ddd
B
e
A
D
C
LA1 α
1
H
h x 45˚
A2
M41T00 Order codes
23/25
9 Order codes
Figure 17. Ordering Information scheme
Example: M41T 00 M 6 E
Device Type
M41T
Supply Voltage and Write Protect Voltage
00 = VCC = 2.0 to 5.5V
Package
M = SO8 (150 mils width)
Temperature Range
6 = –40 to 85°C
Shipping Method
blank = Tubes (Not for New Design - Use E)
E = Lead-free Package (ECO PACK®),
Tubes
F = Lead-free Package (ECO PACK®), Tape &
Reel
TR = Tape & Reel (Not for New Design -
Use F)
Revision history M41T00
24/25
10 Revision history
Table 11. Revision history
Date Revision Changes
March 1999 1.0 First Issue
05/15/00 1.1 AC Characteristic conditions changed (Ta ble 2 )
07/25/00 1.2 Crystal Electrical Characteristics: RS Max changed (Ta b l e 1 0 )
12/12/00 1.3 Edit VSO (Ta b l e 3 )
01/24/01 2.0 Reformatted
02/27/01 3.0 Document Status changed
07/17/01 3.1 Change to DC and AC Characteristics (Ta b l e 9 , Ta bl e 2 ); added
temp./voltage info. to tables
11/27/01 3.2 Features, (page 1); DC Characteristics (Ta b l e 9 ); Crystal Electrical
(Ta bl e 1 0 ); Power Down/Up Trip Points (Tabl e 3) changes; add table
footnote (Table 10)
01/21.02 3.3 Fix table footnotes (Ta bl e 9 , Ta b l e 1 0 )
05/13/02 3.4 Modify reflow time and temperature footnote (Ta bl e 6 )
06/05/02 3.5 Corrected operating voltage (Table <Blue>)
07/03/02 3.6 Modify “Clock Operation” text, Crystal Electrical Characteristics table
footnote (Tabl e 1 0)
11/07/02 3.7 Correct figure name on page1
15-Jun-04 5.0 Reformatted; add Lead-free information; update characteristics
(Figure 12; Ta b l e 6 , Ta b l e 9 , <Blue>)
28-Jun-2004 6 New features summary
M41T00
25/25
Please Read Carefully:
Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the
right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any
time, without notice.
All ST products are sold pursuant to ST’s terms and conditions of sale.
Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no
liability whatsoever relating to the choice, selection or use of the ST products and services described herein.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this
document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products
or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such
third party products or services or any intellectual property contained therein.
UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS
OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZE REPRESENTATIVE OF ST, ST PRODUCTS ARE NOT DESIGNED,
AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS,
NOR IN PRODUCTS OR SYSTEMS, WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR
SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE.
Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void
any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any
liability of ST.
ST and the ST logo are trademarks or registered trademarks of ST in various countries.
Information in this document supersedes and replaces all information previously supplied.
The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners.
© 2006 STMicroelectronics - All rights reserved
STMicroelectronics group of companies
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan -
Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America
www.st.com