Printed in USA 02/05 P/N 110738 rev. A
U-GAGE S18U Series Sensors with Analog Output
18 mm Ultrasonic Sensors with TEACH-mode programming
Features
Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments
Short dead zone
Scalable output automatically distributes the output signal over the width of the
programmed sensing window
Two bi-colored status LEDs
Rugged encapsulated design for harsh environments
Choose 2 meter or 9 meter unterminated cable, or 5-pin Euro-style QD connector
Wide operating range of -20° to +60°C (-4° to +140°F)
Choose either straight or right-angle housing
Temperature compensation
Selectable response times of 2.5 or 30 ms
Select analog models with either 0-10V dc or 4-20 mA output
Model
Number
Sensing
Range Cable* Supply
Voltage Output Housing
Configuration
S18UUA
30 to 300 mm
(1.2" to 11.8")
5-wire, 2 m (6.5') cable
10 to 30V dc
0 to 10V dc
Straight
S18UUAQ 5-pin Euro style QD
S18UIA 5-wire, 2 m (6.5') cable 4 to 20 mA
S18UIAQ 5-pin Euro style QD
S18UUAR 5-wire, 2 m (6.5') cable 0 to 10V dc
Right-Angle
S18UUARQ 5-pin Euro style QD
S18UIAR 5-wire, 2 m (6.5') cable 4 to 20 mA
S18UIARQ 5-pin Euro style QD
Models
WARNING . . . Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for
personnel protection.
!
* 9 m cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., S18UUA W/30).
A model with a QD connector requires a mating cable; see page 10.
Straight Housing
Right-Angle Housing
Information about discrete models is available on Banner’s website: www.bannerengineering.com
Ultrasonic Proximity Mode
Ultrasonic
B
Aug 2013
U-GAGE S18U Series Sensor Analog Output
2 P/N 110738 rev. A
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Principles of Operation
Ultrasonic sensors emit one or multiple pulses of ultrasonic energy, which travel
through the air at the speed of sound. A portion of this energy reflects off the target
and travels back to the sensor. The sensor measures the total time required for the
energy to reach the target and return to the sensor. The distance to the object is then
calculated using the following formula:
D = ct
2
To improve accuracy, an ultrasonic sensor may average the results of several pulses
before outputting a new value.
Temperature Effects
The speed of sound is dependent upon the composition, pressure and temperature of
the gas in which it is traveling. For most ultrasonic applications, the composition and
pressure of the gas are relatively fixed, while the temperature may fluctuate.
In air, the speed of sound varies with temperature according to the following
approximation:
Cm/s = 20 273 + TC
Or, in English units:
Cft/s = 49 460 + TF
Temperature Compensation
Changes in air temperature affect the speed of sound, which in turn affects the distance
reading measured by the sensor. An increase in air temperature shifts both sensing
window limits closer to the sensor. Conversely, a decrease in air temperature shifts
both limits farther away from the sensor. This shift is approximately 3.5% of the limit
distance for a 20° C change in temperature.
The S18U series ultrasonic sensors are temperature compensated. This reduces the
error due to temperature by about 90%. The sensor will maintain its window limits to
within 1.8% over the -20° to +60° C range.
NOTES:
Exposure to direct sunlight can affect the sensors ability to accurately compensate for
changes in temperature.
If the sensor is measuring across a temperature gradient, the compensation will be
less effective.
The temperature warmup drift upon power-up is less than 1.7% of the sensing
distance. After 10 minutes, the apparent distance will be within 0.3% of the actual
position. After 25 minutes, the sensing distance will be stable.
D = distance from the sensor to the target
c = speed of sound in air
t = transit time for the ultrasonic pulse
Cm/s = speed of sound in meters per second
TC = temperature in °C
Cft/s = speed of sound in feet per second
TF = temperature in °F
B
P/N 110738 rev. A 3
U-GAGE S18U Series Sensor Analog Output
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Sensor Programming
Two TEACH methods may be used to program the sensor:
Teach individual minimum and maximum limits, or
Use Auto-Window feature to center a sensing window around the taught position.
The sensor may be programmed either via its push button, or via a remote switch.
Remote programming also may be used to disable the push button, preventing
unauthorized personnel from adjusting the programming settings. To access this
feature, connect the gray wire of the sensor to 0 - 2V dc, with a remote programming
switch between the sensor and the voltage.
NOTE: The impedance of the Remote Teach input is 12 kΩ.
Programming is accomplished by following the sequence of input pulses (see
programming procedures starting on page 4). The duration of each pulse
(corresponding to a push button “click”), and the period between multiple pulses, are
defined as “T”:
0.04 seconds < T < 0.8 seconds
Power/
Signal Strength
LED
TEACH/
Output Indicator
LED
TEACH
Push Button
PWR OUT
TEACH
Figure 1. Sensor features
Minimum
Operating
Range
Near
Setpoint
Far
Setpoint
Maximum
Operating
Range
Target
Target
Target
Target
Dead Zone
Output
Power
Output
Power
Output
Power
ON:
Green
OFF
Output
Power
OFF ON:
Green
ON:
Yellow
ON:
Green
OFF ON:
Red
OFF
Figure 2. TEACH Interface
Status Indicators
Power ON/OFF LED Indicates
OFF Power is OFF.
ON Red Target is weak or outside sensing range.
ON Green Sensor is operating normally, good target.
Output/Teach LED Indicates
OFF Target is outside window limits.
Yellow Target is within window limits.
ON Red (solid) In Teach Mode, waiting for first limit.
ON Red (flashing) In Teach Mode, waiting for second limit.
B
U-GAGE S18U Series Sensor Analog Output
4 P/N 110738 rev. A
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Teaching Minimum and Maximum Limits
General Notes on Programming
The sensor will return to Run mode if the first Teach condition is not registered
within 120 seconds.
After the first limit is taught, the sensor will remain in Program mode until the Teach
sequence is finished.
To exit Program mode without saving any changes, press and hold the programming
push button > 2 seconds (before teaching the second limit). The sensor will revert to
the last saved limits.
Analog Output Slope:
The U-GAGE S18U sensor may be programmed for either a positive or a negative
output slope, based on which limit is taught first (see Figure 3). If the Near limit is
taught first, the slope will be positive. If the Far limit is taught first, the slope will be
negative. Banner’s scalable output automatically distributes the output signal over the
width of the programmed sensing window.
In the event of signal loss, the analog output goes to 3.6 mA or 0V dc, which may be
used to trigger an alarm.
Figure 3. Analog output slope
Procedure
Result
Push Button
0.04 < “click” < 0.8 sec.
Remote Wire
0.04 sec. < T < 0.8 sec.
Programming
Mode
Push and hold the
push button
No action required; sensor is ready for
1st limit teach
Output LED: ON Red
Power LED: ON Green (good signal) or
ON Red (no signal)
Teach
First Limit
Position the target for
the first limit Position the target for the first limit Power LED: Must be ON Green
“Click” the push button • Single-pulse the remote line
Teach Accepted
(Sensor learns the 0V dc or 4 mA limit)
Output LED: Flashing Red
Teach Unacceptable
Output LED: ON Red
Teach
Second Limit
Position the target for
the second limit • Position the target for the second limit Power LED: Must be ON Green
“Click” the push button • Single-pulse the remote line
Teach Accepted
(Sensor learns the 10V dc or 20 mA limit)
Output LED: Yellow or OFF
Teach Unacceptable
Output LED: Flashing Red
T
T
T
T
T
T T
TTT
T T
T T
T
T T
T T
T
T
T
T
T
T
T T
TTT
T T
T T
T
T T
T T
T
...
...
D
or
...
...
D
or
...
...
D
or
B
P/N 110738 rev. A 5
U-GAGE S18U Series Sensor Analog Output
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Procedure
Result
Push Button
0.04 < “click” < 0.8 sec.
Remote Wire
0.04 sec. < T < 0.8 sec.
Programming
Mode
Push and hold the
push button
No action required; sensor is ready for
first limit teach
Output LED: ON Red
Power LED: ON Green (good signal) or
ON Red (no signal)
Teach Limit
Position the target for
the center of the window
Position the target for the center of the
window Power LED: Must be ON Green
“Click” the push button • Single-pulse the remote line
Teach Accepted
Output LED: Flashing Red
Teach Unacceptable
Output LED: ON Red
Re-Teach
Limit
Without moving the
target, “click” the
push button again
Without moving the target,
single-pulse the remote line
again
Teach Accepted
Output LED: Yellow or OFF
Teach Unacceptable
Output LED: Flashing Red
T
T
T
T
T
T T
TTT
T T
T T
T
T T
T T
T
T
T
T
T
T
T T
TTT
T T
T T
T
T T
T T
T
...
...
D
or
...
...
D
or
...
...
D
or
Teaching Limits Using the Auto-Window Feature
Teaching the same limit twice for the same output automatically centers a 100 mm
window on the taught position.
General Notes on Programming
The sensor will return to Run mode if the first Teach condition is not registered
within 120 seconds.
After the first limit is taught, the sensor will remain in Program mode until the Teach
sequence is finished.
To exit Program mode without saving any changes, press and hold the programming
push button > 2 seconds (before teaching the second limit). The sensor will revert to
the last saved limits.
Using this procedure the analog output will be centered on the taught position at
approximately 5V dc or 12 mA.
B
U-GAGE S18U Series Sensor Analog Output
6 P/N 110738 rev. A
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Push Button Lockout
Enables or disables the push button to prevent unauthorized adjustment of the program
settings.
Procedure
Result
Push Button Remote Wire
0.04 sec. < T < 0.8 sec.
Enable/Disable
Push Button
• Not available via push button • Four-pulse the remote line Push buttons are either enabled or disabled,
depending on previous condition.
T
T
T
T
T
T T
TTT
T T
T T
T
T T
T T
T
B
P/N 110738 rev. A 7
U-GAGE S18U Series Sensor Analog Output
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Sensing Range 30 to 300 mm (1.2" to 11.8")
Supply Voltage 10 to 30V dc (10% maximum ripple); 65 mA max. (exclusive of load), 40 mA typical @ 25V input
Ultrasonic Frequency 300 kHz, rep. rate 2.5 ms
Supply Protection Circuitry Protected against reverse polarity and transient voltages
Output Configuration Analog Output: 0 to 10V dc or 4 to 20 mA, depending on model
Output Protection Protected against short circuit conditions
Output Ratings Analog Voltage Output: 2.5 kΩ minimum load resistance
Minimum supply for a full 10V output is 12V dc (for supply voltages between 10
and 12, V out max is at least V supply -2)
Analog Current Output: 1 kΩ max @ 24V input
Max load resistance = (Vcc-4)/0.02 ohms
For current output (4-20 mA) models, ideal results are achieved when the total load resistance
R = [(Vin 3)/0.020]Ω. Example, at Vin = 24V dc, R 1 kΩ (1 watt). A worst-case shift of 1% of sensing
distance is caused by operating the sensor at Vin = 30V dc and R = 0 Ω.
Output Response Time
(for a 95% step change)
2.5 milliseconds: Black wire at 5-30V dc
30 milliseconds: Black wire at 0-2V dc (or open)
Consult factory for other response speed options
Delay at Power-Up 300 milliseconds
Temperature Effect 0.02% of distance/ °C
Linearity* 2.5 ms response: ±1 mm 30 ms response: ± 0.5 mm
Resolution* 2.5 ms response: 1 mm 30 ms response: 0.5 mm
Minimum Window Size 5 mm
Adjustments Sensing window limits: TEACH-Mode programming of near and far window limits may be set using the
push button or remotely via TEACH input (see page 3).
Indicators Range Indicator (Red/Green) GreenTarget is within sensing range
RedTarget is outside sensing range
OFFSensing power is OFF
Teach/Output Indicator (Yellow/Red) Yellow Target is within taught limits
OFFTarget is outside taught window limits
RedSensor is in TEACH mode
Remote TEACH Input Impedance: 12 kΩ
Construction Threaded Barrel: Thermoplastic polyester Push Button Housing: ABS/PC
Push Button: Santoprene Lightpipes: Acrylic
Operating Conditions Temperature: -20° to +60° C (-4° to +140° F) Maximum relative humidity: 100%
Connections 2 m (6.5') or 9 m (30') shielded 5-conductor (with drain) PVC jacketed attached cable or 5-pin
Euro-style quick-disconnect (see page 10 for quick-disconnect cable options)
Environmental Rating Leakproof design is rated IEC IP67; NEMA 6P
Vibration and Mechanical
Shock
All models meet Mil. Std. 202F requirements method 201A (vibration: 10 to 60 Hz max., double amplitude
0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G 11 ms duration, half sine
wave.
Temperature Warmup Drift Less than 1.7% of sensing distance upon power-up (see Temperature Compensation, page 2)
Application Notes Objects passing inside the specified near limit may produce a false response.
Certifications
Specifications
* Linearity and resolution are specified using a 50 mm x 50 mm (2" x 2") aluminum plate at 22°C under fixed sensing conditions.
B
U-GAGE S18U Series Sensor Analog Output
8 P/N 110738 rev. A
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Effective Beam Pattern (Typical)
Sensor Response Curves
Maximum Target Rotation Angle
Lateral Distance
-5 mm
-10 mm
-15 mm
5 mm
0
10 mm
15 mm
20 mm
-20 mm
0 100 mm 150 mm50 mm 200 mm 250 mm 300 mm
Sensing Distance
2.25 mm rod
8 mm rod
50 mm x 50 mm
Target Rotation
Sensing Distance
-5°
-10°
-15°
5°
0
10°
15°
0 50 mm 100 mm 150 mm 200 mm 250 mm 300 mm
Aluminum target used: 50 mm x 50 mm
Hookups
Cabled Models QD Models
bn
shield
bk
gy
bn
bu
wh
+10 - 30V dc
shield shield
Remote Teach 0 - 2V dc
4 - 20 mA or
0 - 10V dc
5 - 30V dc (fast)
0 - 2V dc (slow)
bn
bu
+10 - 30V dc
4 - 20 mA or
0 - 10V dc
wh
gy
0 - 2V dc
bk
5 - 30V dc (fast)
0 - 2V dc (slow)
Remote Teach
NOTE: It is recommended that the shield wire be connected to earth ground or DC common.
B
P/N 110738 rev. A 9
U-GAGE S18U Series Sensor Analog Output
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Dimensions
53.8 mm
(2.12")
90.9 mm
(3.58")
95.1 mm
(3.75")
8.5 mm
(0.33")
58.0 mm
(2.29")
85.1 mm
(3.35")
53.8 mm
(2.12")
80.8 mm
(3.18")
8.5 mm
(0.33")
18.1 mm
(0.71")
18.0 mm
(0.71")
18.0 mm
(0.71")
58.0 mm
(2.29")
3.6 mm
(0.14")
10.6 mm
(0.42")
10.6 mm
(0.42")
Transducer
6.0 mm (0.24")
6.0 mm (0.24")
Transducer
Straight Housing
Right-Angle Housing
Cabled Models QD Models
Cabled Models QD Models
B
U-GAGE S18U Series Sensor Analog Output
10 P/N 110738 rev. A
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Quick-Disconnect Cables
Style Model Length Dimensions Pinout
5-pin
Euro-style
straight, with
shield
MQDEC2-506
MQDEC2-515
MQDEC2-530
2 m (6.5')
5 m (15')
9 m (30')
5-pin
Euro-style
right-angle,
with shield
MQDEC2-506RA
MQDEC2-515RA
MQDEC2-530RA
2 m (6.5')
5 m (15')
9 m (30')
White
Blue
Black
Brown
Gray
M12 x 1
ø 15 mm
(0.6")
44 mm max.
(1.7")
38 mm max.
(1.5")
M12 x 1
ø 15 mm
(0.6")
38 mm max.
(1.5")
Accessories
B
P/N 110738 rev. A 11
U-GAGE S18U Series Sensor Analog Output
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
SMB18A
12-gauge, stainless steel, right-angle
mounting bracket with a curved mounting
slot for versatility and orientation
Clearance for M4 (#8) hardware
SMB18SF
18 mm swivel bracket
Black thermoplastic polyester
Includes stainless steel hardware
SMB18UR
2-piece universal 18 mm swivel bracket
300 series stainless steel
Includes stainless steel swivel locking
hardware
18.5 mm
(0.73")
25.4 mm
(1.00")
41 mm
(1.6")
46 mm
(1.8")
30°
30 mm
(1.2")
R 24.2 mm
(0.95")
ø 4.6 mm*
(0.18")
4.6 mm*
(0.18")
* Use 4 mm (#8) screws
to mount bracket.
Drill screw holes
24.2 mm (0.95") apart.
7.6 mm
(0.30")
SMB18A BRACKET
36.0 mm
(1.42")
50.8 mm
(2.00")
42.0 mm
(1.65") 22.9 mm
(0.9")
25.4 mm
(1.00")
10.6 mm
(0.42")
M18 x 1
internal
thread
Mounting Brackets
50.8 mm
(2.0")
66.0 mm
(2.60")
41.7 mm
(1.64")
24.6 mm
(0.97")
20.8 mm
(0.82")
16.0 mm
(0.63 ")
45.2 mm
(1.78")
ø18.3 mm
(0.72")
2.7 mm
(0.10")
2.7 mm
(0.10")
27.2 mm
(1.07")
ø20.3 mm
(0.80")
ø30.5 mm
(1.20")
R2.5 mm
(0.10")
60º
60º
46.7 mm
(1.84")
9.7 mm
(0.38")
71.1 mm
(2.80")
20.3 mm
(0.80")
4X 6.9 mm
(0.27")
20.3 mm
(0.80")
33.8 mm
(1.33")
60º
25.4 mm
(1.00")
25.4 mm
(1.00")
8.1 mm
(0.32")
41.7 mm
(1.64")
20.8 mm
(0.82")
6X #10-32 Thru
ø30.5 mm
(1.20")
63.5 mm
(2.50")
SMB18UR Top
SMB18UR Bottom
B
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com
U-GAGE S18U Series Sensor Analog Output
P/N 110738 rev A.
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for
one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its
manufacture found to be defective at the time it is returned to the factory during the warranty
period. This warranty does not cover damage or liability for the improper application of
Banner products. This warranty is in lieu of any other warranty either expressed or implied.
B
Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner
Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been
defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the
Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT
LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF
PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER
ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF
PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR
INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR
OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to
any product previously manufactured by Banner Engineering Corp.