DTM250-D Series
0HGLFDO 7HVW
250W Medical / ITE External
Power Supplies
DTM250-D Series 1
www.emea.tdk-lambda.com/dtm250d
&RPP
%URDGFDVW
Specication
Model DTM250-D
Input Voltage range VAC 90 - 264VAC (47 - 63Hz)
Inrush Current A <80A at 230VAC input, 25°C ambient cold start
Input Current A 2.5A @115VAC; 1.3A @230VAC Maximum
Touch Current - <100uA @ 264VAC
Power Factor - Meets EN61000-3-2, >0.9 at 230VAC full load
Hold Up Time (Typ) ms 10ms at 115VAC input
TemperatureCoefcient %/°C ±0.05%/°C
Adjustment Range - None
Minimum Load A None
TotalRegulation % ±5%
Ripple & Noise (pk-pk) mV 12V: 240mV, 19 - 54V: 300mV
Overload&ShortCircuitProtection - 105-160%-hiccupmode
Overvoltage Protection V Auto-recovery
Efciency % >89%,averageefciency
OperatingTemperature °C -20°Cto+60°Cderatelinearlyto50%loadfrom40°Cto60°C
Deratelinearlyto80%loadfrom0°Cto-20°C
Storage Temperature °C -20°C to +85°C
Humidity(noncondensing) %RH 0-95%RH
Cooling - Convection
Withstand Voltage VAC Input to Output 4kVAC (2xMoPP), Input and Output to Ground 1.5kVAC (1xMoPP)
SafetyAgencyCertication - IEC/ES/CSA/EN60601-1,IEC/UL/CSA/EN62368-1,60950-1,CE
OfoadPowerConsumption W <0.15W
EMC - IEC60601-1-2 Ed4:2014, EN55011 Class B, EN55032 Class B,
FCC Part 15 Class B, FCC Part 18 Class B
Altitude m 5,000m maximum
Weight (Typ) g 1300g
Size (WxLxH) (mm) 90 x 200 x 45mm
Cable Length mm 800mm
AC Input Connector - IEC 320-C14 (3 prong)
Output Mating Connector - Molex Mini Fit 39-28-1063 or equivalent; Pins 1 - 3: -Vout, Pins 4 - 6: +Vout
Warranty yrs 3
Features Benets
•MeetsDoELevelVI&EUTier2Efciency •EasierSystemDesign
•Medical&ITECertications •SuitableforB&BFRatedSystems
•<0.15WOff-loadPowerDraw •ConsumesLessEnergy
•MeetsIEC60601-1-2Ed4 •SimpliesEquipmentDesign
Notes: Other connectors are available. Contact factory.