www.recom-power.com REV.: 1/2018 ECO-1
Features
Unregulated
Converters
1kVDC/1 second basic isolation
Optional continuous short circuit protection
UL94 V-0 package material
No heatsink required
Efficiency up to 85%
RI
Description
The RI series has been specifically designed for applications where board space is at a premium since
these 2 Watt converters have only a slightly larger foot print than the RO series 1 Watt converters. With
efficiencies up to 85%, the full output power is available over the operating temperature range -40°C to
+85°C and the converters can be used in ambient temperatures of up to 100°C with derating. The wide
selection of input voltage and output voltage options plus an I/O-Isolation of 1kVDC as standard makes
these converters suitable for many industrial applications.
DC/DC Converter
2 Watt
SIP4
Sinlge Output
EN60950-1 certified
IEC60950-1 certified
Selection Guide
Part nom. Input Output Output Efficiency max. Capacitive
Number Voltage Voltage Current typ.
(1) Load
(2)
[VDC] [VDC] [mA] [%] [µF]
RI-xx05S (3) 5, 12, 15, 24 5 400 78-83 1200
RI-xx12S (3) 5, 12, 15, 24 12 167 80-85 680
RI-xx15S (3) 5, 12, 15, 24 15 133 80-85 680
Model Numbering
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Ordering Examples:
RI-123.3S/P: 12V Input Voltage, 3.3V Output Voltage, Single Output with continuous short circuit protection
RI-0509S: 5V Input Voltage, 9V Output Voltage, Single Output
Input Voltage
Output Voltage
RI- __ __S/_
Protection (3)
Single
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
www.recom-power.com REV.: 1/2018 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RI
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range ±10%
Minimum Load (4) 0%
Internal Operating Frequency 20kHz 50kHz 85kHz
Output Ripple and Noise 20MHz BW 200mVp-p
Notes:
Note4: Operation below 10% load will not harm the converter, but specifications may not be met
Efficiency vs. Load
RI-xx05S
RI-xx15S
RI-xx12S
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0512
1212
2412
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0505
1205
2405
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0515
1215
2415
www.recom-power.com REV.: 1/2018 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RI
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line, full load ±1.2% of 1.0% Vin typ.
Load Regulation 10% to 100% load 5Vout
12, 15Vout
15.0% max.
10.0% max.
Deviation vs. Load
25
15
5
-5
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0505
1205
2405
25
15
5
-5
20
10
0
-10
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
Deviation [%]
0515
1215
2415
25
15
5
-5
20
10
0
-10
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
Deviation [%]
0512
1212
2412
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP) without suffix
with suffix “/P”
1 second
continuous
Isolation Voltage (5) I/P to O/P tested for 1 second
tested for 1 minute
1kVDC
500VAC/60Hz
Isolation Resistance 10G min.
Isolation Capacitance 30pF min./ 85pF max.
Insulation Grade basic
RI-xx05S
RI-xx15S
RI-xx12S
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T2A slow blow type
www.recom-power.com REV.: 1/2018 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RI
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range full load @ free air convection (see graph) -40°C to +85°C
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B. +25°C
+85°C
17900 x 103 hours
7800 x 103 hours
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
85
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ free air convection)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety
1602031 IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
EAC RU-AT.49.09571 TP TC 004/2011
RoHs 2+ RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case
potting
PCB
non-conductive black plastic (UL94 V-1)
epoxy, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH) 11.5 x 7.6 x 10.2mm
Weight 2.0g typ.
continued on next page
www.recom-power.com REV.: 1/2018 ECO-5
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RI
Series
Dimension Drawing (mm)
Recommended Footprint Details
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm
Packaging Quantity tube 42pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
Pinning information
Pin # Dual
1 -Vin
2 +Vin
3 -Vout
4 +Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Top View
0.51
1.27 10.2
7.6
Marking
1.00 Ø +0.15/-0
11.5
7.62
2.03
2.54
2.54
4.10
Bottom View
1 2 3 4 1 2 3 4
embossed logo
0.51+0.10/-0.05
0.25
±0.05