WIZ107SR User Manual
Version 1.71
©2015 WIZnet Co., Ltd. All Rights Reserved.
For more information, visit our website at http://www.wiznet.co.kr
WIZ107SR User Manual (WIZnet Co., Ltd)
Document Revision History
Date Revision Changes
2010-04-23 V1.00 Official Release
2010-04-28 V1.10
Modify the serial command list
2010-08-24 V1.20
1. Added cautions for uploading F/W
2. Added illustration for serial command responses.
3. Added Table 5 to demonstrate the corresponding
serial command responses
2011-01-04 V1.30
Modify the serial command list
1. IT. The time unit is sec, not ms.
2. RT/SV/EX attentions
2012-11-07 V1.50
Added explanation about WIZ107SR revision
1. Added Module Revision Notification.
2. Modified “1.2 Product Contents”.
3. Modified “1.3 Product Spec ification”.
4. Added “Table 4. Available firmware version with
hardware version”.
2013-02-05 V1.60
Added explanation about WIZ107SR-EVB revision
1. Added EVB Revision Notification.
2. Modified “4.2 WIZ107SR Int erface Board Schematic”.
3. Added “4.3 Booting Time” and “4.4 HW_TRIG Pin”.
4. Added attention for using serial command. <Page25>
2013-06-11 V1.61
Modified the part name of “Ordering Information” in section
“Module & EVB Revisi on Notification”.
Changed the name of this part as follo ws.
1. WIZ107SR-UART -> WIZ107SR-RS232
2. WIZ107SR-UART-EVB -> WIZ107SR-RS232-EVB
2015-03-25 V1.70
Added explanation about WIZ107SR-EVB revision 1.4
1. Added EVB Revision Notification
2. Added “4.3 Booting Time” and “4.4 HW_TRIG Pin”.
3. Added “Table 4. Available firmware version with
hardware version”.
Added descriptions for firmware 4.04 or above
1. Added description for H/W Factory reset function
removal and No-PHY link detection function using
HW_TRIG pin.
Modified the Table 5. Serial command response list
1. Added the additional return value (3:ATMODE) of
Device status (ST) command.
2015-04-15 V1.71
Fixed the Typo in “3.2 Serial Command List”
1. Modified the Time unit for Inactivity timer(sec)
WIZ107SR User Manual (WIZnet Co., Ltd)
Module & EVB Revision Notification
<WIZ107SR V1.3 / V1.4 Module>
WIZnet mainly revised the hardware and software of WIZ107SR with the discontinuance of the
main MCU, W7100, in November 2012.
We replaced the W7100 with W7100A, and upgra ded several functions for better performance
and convenience. The change detail is as following.
Part # Hardware
Revision Description of Changes
WIZ107SR
V1.3
1. Operation Temperature : Supports industrial temperature range
Hardware Version V1.1 or below V1.3
Temp. Range 0 ~70 -40 ~ 85
2. Reinforce ESD protection by adding TVS arrays on the RJ45 side.
3.
Change main MCU from W7100 to W7100A with the discontinuance of W7100
.
4. Serial signals support 3.3V TTL level.(Optional)
V1.4
1. Operation Temperature : Supports industrial temperature range
Hardware Version V1.4 or above
Temp. Range -40 ~ 85
2. Removed the MIC811RU for MCU hardware reset.
3. Added the TPS3823-33 as external watchdog for MCU.
Since the hardware form factors and pin maps of all revisions are compatible, ones can
replace the old one with the new one without changing their existing hardware design.
However, they have to use the appropriate firmware according to hardware version. If they
upload the wrong firmware, the module may be work properly.
Part # Hardware Version Available Firmware Version Remark
WIZ107SR
V1.1 or below V2.20 (the latest one)
If you upload the wrong firmware, the module may
not work properly.
There is no difference in all functions and features.
V1.3 V3.04 ~ V3.14
V1.4 or above V4.04 or above
WIZ107SR User Manual (WIZnet Co., Ltd)
<WIZ107SR-EVB>
From the WIZ107SR rev1.3, the module optionally supports the TTL signal on the serial side.
With this change, we changed the base board of WIZ107SR-EVB to test both of WIZ107SR-
RS232 and WIZ107SR-TTL. Therefore, when you order the WIZ107SR or WIZ107SR-EVB, please
specify the version by referring below ordering information.
To test WIZ107SR UART version To test WIZ107SR TTL version
<Ordering Information>
Category Part No Description
Module WIZ107SR-RS232 Compact Size Serial to Ethernet Module
Serial : RS-232 / Network : RJ-45
WIZ107SR-TTL Compact Size Serial to Ethernet Module
Serial : TTL / Network : RJ-45
EVB WIZ107SR-RS232-EVB Evaluation Board for WIZ107SR-RS232
WIZ107SR-TTL-EVB Evaluation Board for WIZ107SR-TTL
WIZ107SR User Manual (WIZnet Co., Ltd)
WIZnet’s Online Technical Support
If you have something to ask about WIZnet products, write down your question on
Q&A Board in WIZWiki Forum (http://wizwiki.net/forum/). WIZnet will give an
answer as soon as possible.
COPYRIGHT NOTICE
Copyright 2015 WIZnet Co., Ltd. All Rights Reserved.
Technical Support: Our Forum, http://wizwiki.net/forum/
Sales & Distribut ion: sales@wiznet.co.kr
For more information, visit our website at http://www.wiznet.co.kr
WIZ107SR User Manual (WIZnet Co., Ltd)
Table of Contents
1. Introduction ............................................................................................... 1
1.1 Key Features ....................................................................................... 1
1.3.1 WIZ107SR Module Specification ......................................................... 3
1.3.2 WIZ107SR Module Interface .............................................................. 4
1.3.3 Pin Header Connector Pin-Assignment ................................................. 5
2. Getting Started ........................................................................................... 6
2.1 Configuration Tool ................................................................................. 6
2.1.1 Network Configuration .................................................................... 6
2.1.2 Serial Configuration ...................................................................... 11
2.1.3 Option Configuration ..................................................................... 13
2.2 Firmware Upload ................................................................................. 15
3. Serial Configuration ..................................................................................... 18
3.1 Serial Command Format ......................................................................... 18
3.2 Serial Command List ............................................................................. 18
3.3 Serial Command Executing Example .......................................................... 24
4. Hardware Specification ................................................................................ 26
4.1 WIZ107SR Dimension ............................................................................. 26
4.2 WIZ107SR Interface Board Schematic ......................................................... 27
4.3 Booting Time ...................................................................................... 28
4.4 HW_TRIG PIN ..................................................................................... 28
5. Warranty .................................................................................................. 29
WIZ107SR User Manual (WIZnet Co., Ltd)
Figures
FIGURE 1. WIZ107SR INTERFACE ............................................................................... 4
FIGURE 2. WIZ107SR CONNECTOR PIN ASSIGNMENT ............................................................ 5
FIGURE 3. WIZ107SR CONFIGURATION TOOL (NETWORK CONFIGURATION PAGE) ................................ 6
FIGURE 4. SEARCHING WITH UDP BROADCAST METHOD .......................................................... 7
FIGURE 5. SEARCHING WITH TCP UNICAST METHOD .............................................................. 7
FIGURE 6. SIMPLE PING TEST PROGRAM ......................................................................... 8
FIGURE 7. WIZ107SR CONFIGURATION TOOL (SERIAL CONFIGURATION PAGE) .................................. 11
FIGURE 8. WIZ107SR CONFIGURATION TOOL (OPTION CONFIGURATION PAGE) ................................. 13
FIGURE 9. FILE OPEN DIALOG BOX FOR FIRMWARE UPLOADING ................................................... 15
FIGURE 10. FIRMWARE UP LOADE D SUCCESSFULLY ................................................................ 16
FIGURE 11. ERROR MESSAGE ABOUT UPLOADING DIFFERENT VERSION FIRMWARE .................................. 17
FIGURE 12. SERIAL COMMAND FORMAT .......................................................................... 18
FIGURE 13. SERIAL COMMAND EXECUTING EXAMPLE ............................................................. 25
FIGURE 14. WIZ107SR DIMENSIONS (UNIT : MM) ............................................................... 26
FIGURE 15. WIZ107SR INTERFACE BOARD SCHEMATIC ......................................................... 27
FIGURE 16. WIZ107SR’S OPERATION FLOW ................................................................... 28
Tables
TABLE 1. PRODUCT CONTENTS................................................................................... 2
TABLE 2. WIZ107SR MODULE SPECIFICATION ................................................................... 3
TABLE 3. PIN HEADER CONNECTOR PIN-ASSIGNMENT DESCRIPTION .............................................. 5
TABLE 4. AVAILABLE FIRMWARE VERSION WITH HARDWARE VERSION ............................................... 17
TABLE 5. SERIAL COMMAND LIST ................................................................................ 19
TABLE 6. WIZ107SR’S BOOTING TIME ......................................................................... 28
WIZ107SR User Manual (WIZnet Co., Ltd.) 1
1. Introduction
WIZ107SR is a gateway module that converts serial protocol (RS-232) into TCP/IP protocol.
It enables remote management and control of a serial device through TCP/IP network.
In other words WIZ107SR is the protocol converter that transmits the data sent by serial
equipment as TCP/IP data type, and converts back the TCP/IP data received through the
network into serial data to transmit back to the equipment.
1.1 Key Features
Compact Sized RS-232 to Ethernet Converting Module
Quick and Simple Internet Connection to Serial Devices
Supports Firmware Customization ac cordin g to Custome rs Requirement
Guarantees Stable and Reliable Data Communication by using W7100A One chip
solution
Provides User -Friendly Configuration Tool Program
User Password Configurable for Security
Supports Serial Command for Serial configuration
10/100 Mbps Ethernet & Max 230Kbps Serial Interface
Supports IP Configuration - Static, DHCP
Supports DNS
Compact design 48mm X 30mm X 18mm ( L x W x H )
RoHS Compliant
WIZ107SR User Manual (WIZnet Co., Ltd.) 2
1.2 Product Contents
WIZ107SR
EVB
WIZ107SR
WIZ107SR Interface Board
Accessories
12-pin Cable
( Connect WIZ107SR with Interface Board )
LAN Cable
Serial Cable
Power
( DC 5V / 2A Adaptor )
Table 1. Product Contents
If there is any missing item, contact to the shop where you purchased.
WIZ107SR User Manual (WIZnet Co., Ltd.) 3
1.3 Product Specification
1.3.1 WIZ107SR Module Specification
WIZ107SR includes WIZnet’s hardwired TCP/IP chip that embeds the most of TCP/IP protocols
such as TCP, UDP, IP, ARP, ICMP, IGMP and Ethernet MAC. 10Mbps and 100Mbps Ethernet are all
supported and a standard RJ-45 is mounted on the board of WIZ107SR. One serial port is
provided in WIZ107SR via 12-pin connector which features the standard RS-232 specification.
WIZ107SR can be powered by a DC 3.3V power supply with the max 250mA current supply. The
detailed specifications are listed in Table 2
Architecture
TCP / IP W7100A
PHY
Included in W7100A
Auto negotiation (Full-duplex and Half-duplex)
Auto MDI/MDIX
Serial WIZ107SR : RS-232C
MCU
Included in W7100A
(Fully software compatible with industrial standard 8051)
Internal 2KBytes Boot ROM
Internal 64KBytes embedded program FLASH memory
Internal 256Bytes embedded data FLASH memory
Internal 64KBytes embedded SRAM
Internal 32KBytes me mory for TCP/IP data communication
Serial
Interface WIZ107SR : Included RS-232C Transceiver,
Signals WIZ107SR : TXD, RXD, RTS, CTS, GND
Parameters
WIZ107SR
- Parity : None, Odd, Even
- Data bits : 7, 8 bit
- Flow control : None, RTS / CTS, XON / XOFF
Speed Up to 230Kbps
Dimensions 48mm x 30mm x 18mm ( Include connector size )
Connector type 2.54mm Pitch Pin-header, 12Pin (2*6)
Input voltage DC 3.3V
Max power consumption 250mA
Temperature -40C ~ 85C (Operation), -40C ~ 85C (Storage)
Humidity 10 ~ 90%
Table 2. WIZ107SR Module Specification
WIZ107SR User Manual (WIZnet Co., Ltd.) 4
1.3.2 WIZ107SR Module Interface
Figure 1. WIZ107SR Interface
WIZ107SR User Manual (WIZnet Co., Ltd.) 5
1.3.3 Pin Header Connector Pin-Assignment
WIZ107SR provides an external connector to connect it with your application board. The pin
assignment and definition of the connector are introduced in Figure 2 and the specification of
each pin is described in Table 3.
1 VCC 2 VCC
3 RXD 4 nRESET
5 RTS 6 nFAC_RST
7 TXD 8 HW_TRIG
9 CTS 10 NC
11 GND 12 GND
Figure 2. WIZ107SR Conn ec tor Pin Assignment
Pin Number Signal Description
1 VCC System Power input (3.3V)
2 VCC System Power input (3.3V)
3 RXD RS-232C Receive Data
4 nRESET System Reset signal input / Active Low
5 RTS RS-232C Request To Send / Optional
6 nFAC_RST Factory Reset sign al input / Active Low
[ Function Removed: Firmware v4.04 or above]
The H/W F actory reset function pin removed for more stable operation. but S/W
Factory reset still exists.
7 TXD RS-232C Transmit Data
8 HW_TRIG Hardware Trigger signal input / Low : CMD mode
[ In the initial time, this pin is INPUT for Hardware Tri gger(for serial command
mode). After that, this pin is OUTPUT for connection status. When the connection
is established, this pin goes Low. And, it will go HIGH when connection is closed. ]
[ Function Added: Firmware v4.04 or above]
In No-PHY link (like Ethernet cable is disconnected) case, HW_TRIG pin
generates High and low signal in turns every second. When returning to normal
condition, HW_TRIG displays TCP connection status as usual.
9 CTS RS-232C Clear To Send / Optional
10 NC Not connect
11 GND System Ground
12 GND System Ground
Table 3. Pin Header Connector PIN-Assignment Description
WIZ107SR User Manual (WIZnet Co., Ltd.) 6
2. Getting Started
2.1 Configuration Tool
2.1.1 Network Configuration
Figure 3. WIZ107SR Configuration Tool (Network Configuration Page)
1) Search
The Search function is used to search all devices existing in the same LAN or in WAN. By
using UDP broadcast as shown in Figure 4, all connected devices in the same subnet will
be found. If the TCP unicast method is checked, the specified IP address must be given as
shown in Figure 5. The founded device will be listed in the “Serial to Ethernet” tree with
its MAC address.
Please, note the identification code must be input if the device has been configured with
one identification code.
WIZ107SR User Manual (WIZnet Co., Ltd.) 7
Figure 4. Searching with UDP broadcast method
Figure 5. Searching with TCP unicast method
2) Setting
This function is to complete the configuration change.
If you select the MAC Address from the “Serial to Ethernet” tree, the default
configuration value of the module will be displayed. Change the configuration and click
“Setting” button to complete the configuration. The module will re-initialize with the
changed configuration. Changed value is saved in the EEPROM of the module. Thus, the
value is not removed even though power is disconnected.
3) Upload
Firmware will be uploaded through network
WIZ107SR User Manual (WIZnet Co., Ltd.) 8
4) Reset
Reset and restart the selected module if you select the MAC Address from the tree and
click “Reset” button.
5) Factory
All value is initialized to Factory default value if you select the MAC Address from the
tree and click “Factory” button.
6) Ping
Popup the Simple Ping application progra m, you can test the ping operation.
Figure 6. Simple Ping Test Program
7) Firewall
Popup the Windows Firewall setup program.
8) Exit
Close the configuration Tool Program.
9) Search window
If you click “Search” button, all the MAC address on a same subnet, will be displayed this
area. You can see the basic information such as Model name, Firmware version Etc.
10) Network Setting Method
Select IP setting mode, you can select one of Static, DHCP.
(PPPoE mode is not suppor t ed in the WI Z107SR)
- Using the follow IP Address (Static)
This is option for setting WIZ107SR module’s IP with static IP address. Firstly, select
MAC address which you wanted to set as static IP in the board list. Then “Device IP,
Subnet, Gateway box” will be enabled. Input Static IP address and click “setting”
button. Then set the IP address as you want.
- DHCP
Set this option to use DHCP mode. Firstly, check ‘DHCP’ and click ‘Setting’ button. If IP
WIZ107SR User Manual (WIZnet Co., Ltd.) 9
address is successfully acquired from DHCP server, the MAC address will be displayed on
the configuration window. (It takes some time to acq u ire I P address from DHCP server)
When a module on the board list is selected, IP address, Subnet mask and Gateway are
displayed. If module could not acquire network information from DHCP server, IP
address, Gateway Address and Subnet mask will be initialized to 0.0.0.0.
11) Network Operation Mode
Client / server / mixed : This is to select the communication method based on TCP. TCP is
the protocol to establish the connection before data communication, but UDP just
processes the data communication without connection establishment. The Network mode
of WIZ107SR can be divided into TCP Server, TCP Client and Mixed mode according to the
connection establishing method. At the TCP server mode, WIZ107SR operates as server on
the process of connection, and waits for the connection trial from the client. WIZ107SR
operates as client at the TCP Client mode on the process of connection, and tries to
connect to the servers IP and Port. Mixed modes supports both of Server and Client. The
communication process of each mode is as below.
<TCP server mode Communication>
At the TCP Server mode, WIZ107SR waits for the connection requests.
TCP Server mode can be useful when the monitoring center tries to connect to the device
(where WIZ107SR is installed) in order to check the status or provide the commands. In
normal time WIZ107SR is on the waiting status, and if there is any connection request
(SYN) from the monitoring center, the connection is established (ESTABLISH), and data
communication is processed (Data Transaction). Finally connection is closed (FIN).
In order to operate this mode, Lo cal IP, Subnet, Gateway Address and Local Port Number
should be configured first.
The Data transmission proceeds as follows,
1. The host connects to the WIZ107SR which is configured as TCP Server mode.
2. As the connection is established, data can be transmitted in both directions – from the
host to the WIZ107SR, and from the WIZ107SR to the host
<TCP client mode Communication>
If WIZ107SR is set as TCP Client, it tries to establish connection to the server.
To operate this mode, Local IP, Subnet, Gateway Address, Server IP, and Server port
number should be set. If server IP had domain name, use DNS function.
WIZ107SR User Manual (WIZnet Co., Ltd.) 10
In TCP Client mode, WIZ107SR can actively establish a TCP connection to a host computer
when power is supplied.
The Data transmission proceeds as follows:
1. As power is supplied, WIZ107SR board operating as TCP client mode actively
establishes a connection to the server.
2. If the connection is complete, data can be transmitted in both directions – from the
host to the WIZ107SR and from WIZ107SR to the host
<Mixed mode Communication>
In this mode, WIZ107SR normally operates as TCP Server and waits for the connection
request from the peer. However, if WIZ107SR receives data from the serial device before
connection is established, it changes to the client mode and sends the data to the server
IP. Therefore, at the mixed mode, the server mode is operated prior to the client mode.
As like TCP Server mode, the Mixed mode is useful for the case that the monitoring
center tries to connect to the serial device (in which WIZ107SR is used) to check device
status. In addition to this, if any emergency occurs in the serial device, the module will
change to Client mode to establish the connection to the server and deliver the
emergency status of the device.
<UDP mode Communication>
UDP is not a connection oriented protocol. But the communication port should also be
defined well. If the UDP mode is selected, the data from serial interface can be defined
where to delivery via the “Sever IP Address” and “Port”, and the WIZ107SR can also be
defined where to receive Ethernet data from via the “Remote Peer IP Address” definition.
If the data destination and source are the same, the two IP address will also be the same.
Please note the destination and source are using the same port.
12) DDNS Setting
DDNS function is not supported in the WIZ107SR.
WIZ107SR User Manual (WIZnet Co., Ltd.) 11
2.1.2 Serial Configuration
Figure 7. WIZ107SR Configuration Tool (Serial Configuration Page)
1) Enable debug message output
If this mode is checked, you can monitor the status of module and socket message like
listen OK, connect fail etc. through serial terminal. If debug mode is on, debug message
can cause abnormal operation of the serial device. Therefore, just use this mode only for
debug mode.
2) COM port Setting
The parameters of COM port of WIZ107SR are listed well in this page. Us ers can set the COM
port of WIZ107SR by selecting the value of each parameter in the drop down list.
By clicking the “Setting” button, changed value can be applied.
3) Serial data packing condition settings
You can designate how the serial data can be packed to send to the Ethernet.
In default mode, WIZ107SR checks the serial buffer and sends any received data to Ethernet
without any standard. Therefore, the data can be regarded as error data due to
WIZ107SR User Manual (WIZnet Co., Ltd.) 12
inconsistent data length. In order to solve this problem, the data from serial can be packed
according to the specifie d condition before sending to Ethernet. The condition is as below.
Time: If there is not any new data during designated time, all data in the serial buffer is
converted to Ethernet packet. If new data is received, the time is re-calculated and
the received data is saved in the serial buffer. Time condition can be utilized when
the serial data size is variable and has no ending char acter, but needs to be delivered
in frame unit. (If the value is ‘0’, option is not used)
Size: When data is collected as much as the defined size in the serial buffer, it is
transmitted to Ethernet (If the value is ‘0’, option is not used)
Character: The data is collected in the serial buffer until specified character is received,
and transmitted to Ethernet. The character can be specified in Hex formation.
(The value is ‘0’, this option is not used)
One of three conditions is sati sfied, the data is transmitted to the Ethernet.
Ex) Delimiter : Size=10, Char=0x0D
Serial data : 0123456789abc
Ethernet data : 0123456789
“abc” data remains in the serial buffer of module.
4) Serial command mode switch code
This function is for module configuration not through network with Configuration tool but
through serial communication. At the default status, the serial command mode is disabled.
When you want to set via serial communication, check “enable”.
WIZ107SR User Manual (WIZnet Co., Ltd.) 13
2.1.3 Option Configuration
Figure 8. WIZ107SR Conf iguratio n Tool (Option Configuration Page)
1) T imer interval
- Inactivity Timer : The connection holding pe riod when no data transmission.
- Reconnection Interval : The connection retry interval (client mode only)
After the connection is established, if there is not data transmission within the time
defined in Inactivity time, the connection is closed automatically. The default value is ‘0’.
If ‘0’ is set, this function is not activated. In this default setting, the connection is
maintained even though there is no data transmission. In order to close the connection, the
‘Close’ command should be given.
This function can be used for more than two or more systems to connect to a WIZ107SR
module. If one system holds the connection to the WIZ107SR, other systems cannot connect
to the module. If there is no data transmission during the time defined in Inactivity time,
the connection will be closed for other system to be connected.
WIZ107SR User Manual (WIZnet Co., Ltd.) 14
Inactivity Time also can be useful for the case when the server system is unexpectedly shut
down. In this status, if there is not any data communication during the time defined in the
Inactivity time, WIZ107SR will close the connection and enter into waiting status.
2) Search identification code
For the security issues, WIZ107SR can have it s own password for searching. The password is
stored in the EEPROM of WIZ107SR, and it can be modified via this configuration tool. The
password can be any alphabet or number. Its length can be variable and its maximum length
is 8 bytes. The password is case sensitive.
3) Connection password
This function is available only when WIZ107SR works in server mode. If this function is
enabled, the remote client should send the password to WIZ107SR before data transmission.
Please, note the password is case sensitive.
4) Network protocol settings
There are two kinds of data transmission protocol: one is raw data transmission, and the
other is using Telnet (RFC2217).
But in current version, only the raw data transmission is supported.
If the ‘Keep alive’ function is enabled, WIZ107SR will send keep alive packet in every user
set minutes if no reply received after the user set period.
WIZ107SR User Manual (WIZnet Co., Ltd.) 15
2.2 Firmware Upload
1) Run the Configuration Tool program and click “Search” button, and input search
password in the password popup dialog if you set the search password.
2) If the module is properly connected to the network then MAC address will be displayed
on the “Serial to Ethernet” search result area.
3) Select a MAC address shown in search result and click “Upload” button.
Before uploading through Ethernet, you should set the network information of
WIZ107SR first by Configuration Tool program.
4) When the window as shown below Figure is displayed, select file for upload and click
“Open” button.
Do not upload any other files except for WIZ107SR application firmware file. If you
uploaded other files by accident, Configuration Tool cannot search out WIZ107SR so
that uploading a correct one via Ethernet is impossible. In this case, you should erase
code and data flash in W7100 and upload a correct file by using “WIZISP for iMCU
W7100”
Don’t turn power off while F/W is being uploaded.
Figure 9. File open dialog box for Firmware uploading
WIZ107SR User Manual (WIZnet Co., Ltd.) 16
5) When the firmware is uploaded successfully, the following message box will be shown.
Figure 10. Firmware uploaded successfully
WIZ107SR User Manual (WIZnet Co., Ltd.) 17
If you try to upload the wrong version of firmware, the following message box will be
displayed.
Figure 11. Error message about uploading different version firmware
Please check the firmware version. And upload the appropriate one according to the h ardware
version
Part # Hardware Version Available Firmware Version Remark
WIZ107SR
V1.2 or below V2.20 (the latest one) If you upload the wrong firmware, the
module may not work properly.
There is no difference in all functions and
features.
V1.3 V3.03 ~ V3.14
V1.4 or above V4.04 or above
Table 4. Available firmware version with hardware version
WIZ107SR User Manual (WIZnet Co., Ltd.) 18
3. Serial Configuration
3.1 Serial Command Format
If WIZ107SR is in serial configuration mode, users can use the following predefined commands
to configure WIZ107SR via serial interface. The format of serial command is shown in Figure
12. Each command starts with a command name (2 characters) and ends with ‘\r\n’. If the
data field is null, it means the command does a reading operation. Otherwise, the command
do writing operation. Ones can get response in case of reading operation of Commands, the
format of response is the same with Serial command format.
Command Data \r \n
Figure 12. Serial command format
3.2 Serial Command List
The commands are listed in the following Table 5.
CMD Data Description
MC -- MAC address (read only)
VR -- Firmware version (read only)
MN -- Model name (read only)
ST -- Device status (read only)
0:OPEN, 1:CONNECT, 2:UPGRADE 3:ATMODE
UN -- Total UART number (read only)
LG -- Debug log message (read only)
ER -- Error message (read only)
IM 0:STATIC, 1:DHCP, 2:PPPoE Obtain IP method
OP 0:CLIENT, 1:SERVER, 2:MIXED, 3:UDP Operation mode
DD 1:ENABLE, 0:DISABLE DDNS enable/disable flag
CP 1:ENABLE, 0:DISABLE Connection password enable/di sable flag
PO 0:RAW, 1:TELNET Data transmission protocol
(only raw data transmission is supported for
current version)
DG 1:ENABLE, 0:DISABLE Debug message output flag
KA 1:ENABLE, 0:DISABLE Keep alive flag
KI 0 ~ 65535 Tx KeepAlive interval (0~65535ms)
KE 0 ~ 65535 KeepAlive enable interval (0~65535ms)
RI 0 ~ 65535 Reconnection interval
WIZ107SR User Manual (WIZnet Co., Ltd.) 19
Table 5. Serial command list
(client mode only, 0~65535ms)
LI 192.168.11.2 (Default value) Local IP address
SM 255.255.255.0 (Default value) Subnet mask
GW 192.168.11.1 (Default value) Gateway
DS 0.0.0.0 (Default value) DNS server IP
LP 5000 (Default value) Local port number
RP 5000 (Default value) Remote host port number
RH 192.168.101.200 (Default value) Remote host IP/name
BR 0:300bps, 1:600bps, 2:1200bps,
3:1800bps, 4:2400bps, 5:4800bps,
6:9600bps, 7:14400bps, 8:19200bps,
9:28800bps, 10:38400bps,
11:57600bps, 12:115200bps,
13:230400bps
Baud rate index
DB 0:7bit, 1:8bit, 2:9bit Data bit
PR 0:NONE, 1:ODD, 2:EVEN parity
SB 0:1bit, 1:2bit Stop bit
FL 0:NONE, 1:XON/XOFF, 2:CTS/RTS Flow Control
IT 0 ~ 65535 Inactivity timer (0~65535sec)
PT 0 ~ 65535 Serial data packing interval (0~65535ms)
PS 0 ~ 255 Packing size (0~255)
PD 0 ~ 255 Packing indicator (0~255)
TE 1:Enable, 0:Disable Software trigger enable flag
SS 010203 (Default value) software trigger (fixed 3 bytes in hex)
NP ******** Connection password (Max. 8 bytes)
SP ******** Search password (Max. 8 bytes)
EC 1:Enable, 0:Disable Show serial input echo or not
WIZ108SR is not supported this CMD.
SV -- Save setting message
(After command, WIZ107SR needs some
delay about 50ms)
RT -- Reboot the device
EX -- Exit from command mode
FR -- Factory Reset
WIZ107SR User Manual (WIZnet Co., Ltd.) 20
The corresponding responses samples of serial commands are listed in the following Table 5.
Command Input Response
MC
Read only
commands: Data
field is null.
In ASCII: MC\r\n
In HEX: 4D 43 0D 0A
MC00:08:DC:##:##:##\r\n
VR In ASCII: VR\r\n
In HEX: 56 52 0D 0A
VR1.4\r\n
MN In ASCII: MN\r\n
In HEX: 4D 4E 0D 0A
MNWIZ107SR\r\n
ST In ASCII: ST\r\n
In HEX: 53 54 0D 0A
STATMODE\r\n
UN In ASCII: UN\r\n
In HEX: 55 4E 0D 0A
UN1\r\n
LG
Users are not allowed to input this
command. This command can only
be displayed by system. See
example on right side.
LGIP:192.168.11.2\r\n
ER
Users are not allowed to input this
command. This command can only
be displayed by system. See
example on right side.
ERNOCOMMAND:kk\r\n
IM
Null data In ASCII: IM\r\n
In HEX: 49 4D 0D 0A
IM0
With data In ASCII: IM0\r\n or IM1\r\n
In HEX: 49 4D 31 0D 0A or …
No Response
OP
Null data In ASCII: OP\r\n
In HEX: 4F 50 0D 0A
OP0
With data
In ASCII: OP0\r\n or OP1\r\n or
OP3\r\n
In HEX: 4F 50 31 0D 0A or …
No Response
DD
Null data In ASCII: DD\r\n
In HEX: 44 44 0D 0A
DD0\r\n
With data In ASCII: DD0\r\n or DD1\r\n
In HEX: 44 44 31 0D 0A or …
No Response
CP Null data In ASCII: CP\r\n CP0\r\n
WIZ107SR User Manual (WIZnet Co., Ltd.) 21
In HEX: 43 50 0D 0A
With data In ASCII: CP0\r\n or CP1\r\n
In HEX: 43 50 31 0D 0A or …
No Response
PO
Null data In ASCII: PO\r\n
In HEX: 50 4F 0D 0A
PO0\r\n
With data In ASCII: PO0\r\n or PO1\r\n
In HEX: 50 4F 31 0D 0A or …
No Response
DG
Null data In ASCII: DG\r\n
In HEX: 44 47 0D 0A
DG1\r\n
With data In ASCII: DG0\r\n or DG1\r\n
In HEX: 44 47 31 0D 0A or …
No Response
KA
Null data In ASCII: KA\r\n
In HEX: 4B 41 0D 0A
KA0\r\n
With data In ASCII: KA0\r\n or KA1\r\n
In HEX: 4B 41 31 0D 0A or …
No Response
KI
Null data In ASCII: KI\r\n
In HEX: 4B 49 0D 0A
KI0\r\n
With data In ASCII : KI100 \r\n
In HEX: 4B 49 31 30 30 0D 0A
No Response
KE
Null data In ASCII: KE\r\n
In HEX: 4B 45 0D 0A
KE0\r\n
With data In ASCII: KE100\r\n
In HEX: 4B 45 31 30 30 0D 0A
No Response
RI
Null data In ASCII: RI\r\n
In HEX: 52 49 0D 0A
RI0\r\n
With data In ASCII : RI100 \r\n
In HEX: 52 49 31 30 30 0D 0A
No Response
LI
Null data In ASCII: LI\r\n
In HEX: 4C 49 0D 0A
LI192.168.11.2\r\n
With data
In ASCII: LI192.168.11.20\r\n
In HEX: 4C 49 31 39 32 2E 31 36 38
2E 31 31 2E 32 3 0 0D 0A
No Response
SM
Null data In ASCII: SM\r\n
In HEX: 53 4D 0D 0A
SM255.255.255.0\r\n
With data In ASCII: SM255.255.255.0\r\n
In HEX: 53 4D 32 35 35 2E 32 35 35
No Response
WIZ107SR User Manual (WIZnet Co., Ltd.) 22
2E 32 35 35 2E 30 0D 0A
GW
Null data In ASCII: GW\r\n
In HEX: 47 57 0D 0A
GW192.168.11.1\r\n
With data
In ASCII: GW192.168.11.1\r\n
In HEX: 47 57 31 39 32 2E 31 36 38
2E 31 31 2E 31 0D 0A
No Response
DS
Null data In ASCII: DS\r\n
In HEX: 44 53 0D 0A
DS192.168.11.22\r\n
With data
In ASCII: DS1.2.3.4\r\n
In HEX: 44 53 31 2E 32 2E 33 2E 34
0D 0A
No Response
LP
Null data In ASCII: LP\r\n
In HEX: 4C 50 0D 0A
LP5000\r\n
With data In ASCII: LP5000\r\n
In HEX: 4C 50 35 30 30 30 0D 0A
No Response
RP
Null data In ASCII: RP\r\n
In HEX: 52 50 0D 0A
RP5000\r\n
With data In ASCII: RP5000\r\n
In HEX: 52 50 35 30 30 30 0D 0A
No Response
RH
Null data In ASCII: RH\r\n
In HEX: 52 48 0D 0A
RH1.2.3.4\r\n
With data
In ASCII: RH1.2.3.4\r\n
In HEX: 52 48 31 2E 32 2E 33 2E 34
0D 0A
No Response
BR
Null data In ASCII: BR\r\n
In HEX: 42 52 0D 0A
BR11\r\n
With data In ASCII: BR11\r\n
In HEX: 42 52 31 31 0D 0A
No Response
DB
Null data In ASCII: DB\r\n
In HEX: 44 42 0D 0A
DB1\r\n
With data In ASCII: DB1\r\n
In HEX: 44 42 31 0D 0A
No Response
PR
Null data In ASCII: PR\r\n
In HEX: 50 52 0D 0A
PR0\r\n
With data In ASCII: PR0\r\n
In HEX: 50 52 30 0D 0A
No Response
WIZ107SR User Manual (WIZnet Co., Ltd.) 23
SB
Null data In ASCII: SB\r\n
In HEX: 53 42 0D 0A
SB0\r\n
With data In ASCII: SB0\r\n
In HEX: 53 42 30 0D 0A
No Response
FL
Null data In ASCII: FL\r\n
In HEX: 46 4C 0D 0A
FL0\r\n
With data In ASCII: FL0\r\n
In HEX: 46 4C 30 0D 0A
No Response
IT
Null data In ASCII: IT\r\n
In HEX: 49 54 0D 0A
IT0\r\n
With data In ASCII: IT100\r\n
In HEX: 49 54 31 30 30 0D 0A
No Response
PT
Null data In ASCII: PT\r\n
In HEX: 50 54 0D 0A
PT0\r\n
With data In ASCII: PT100\r\n
In HEX: 50 54 31 30 30 0D 0A
No Response
PS
Null data In ASCII: PS\r\n
In HEX: 50 53 0D 0A
PS0\r\n
With data In ASCII: PS0 \r\n
In HEX: 50 53 30 0D 0A
No Response
PD
Null data In ASCII: PD\r\n
In HEX: 50 44 0D 0A
PD0\r\n
With data In ASCII: PD0 \r\n
In HEX: 50 44 30 0D 0A
No Response
TE
Null data In ASCII: TE\r\n
In HEX: 54 45 0D 0A
TE0\r\n
With data In ASCII: TE1\r\n
In HEX: 54 45 31 0D 0A
No Response
SS
Null data In ASCII: SS\r\n
In HEX: 53 53 0D 0A
SS2B2B2B\r\n
With data
In ASCII: SS010101\r\n
In HEX: 53 53 30 31 30 31 30 31 2B
2B 0D 0A
No Response
NP Null data In ASCII: NP\r\n
In HEX: 4E 50 0D 0A
NP110\r\n
With data In ASCII: NP110 \r\n No Response
WIZ107SR User Manual (WIZnet Co., Ltd.) 24
In HEX: 4E 50 31 31 30 0D 0A
SP
Null data In ASCII: SP\r\n
In HEX: 53 50 0D 0A
SP110\r\n
With data In ASCII: SP110\r\n
In HEX: 53 50 #31 31 30 0D 0A
No Response
EC
Null data In ASCII: EC\r\n
In HEX: 45 43 0D 0A
EC0\r\n
With data In ASCII: EC1 \r\n
In HEX: 45 43 31 0D 0A
No Response
SV
Data field is null
In ASCII: SV\r\n
In HEX: 53 56 0D 0A
No Response
RT In ASCII: R T\r\n
In HEX: 52 54 0D 0A
Reboot display
EX In ASCII: EX\r\n
In HEX: 45 58 0D 0A
No Response
FR In ASCII: FR\r\n
In HEX: 46 52 0D 0A
Reboot display
Table 5. Serial command response list
3.3 Serial Command Executing Example
Figure 13. shows an example with several commands executed. At first, WIZ107SR should be
set into serial configuration mode (both hardware trigger and software trigger can be used).
For hardware trigger, the trigger should be turned on and reset the WIZ107SR, and the
software trigger code should be sent to change WIZ107SR into serial configuration mode.
In this example, the serial echo message is on and the software trigger is used to enter the
serial configuration mode. And then, the user inputs command ‘MC’ with ‘Enter’ key pressed
to read the MAC address of the WIZ107SR. You can find that the WIZ107SR responses with
‘MC00:08:DC:01:02:03’. In the same way, we can read the IP address of WIZ107SR. This
example also shows how to modify the parameters of WIZ107SR. After reading IP address, the
user inputs ‘LI192.168.11.20’ with ‘Enter’ key pressed in hyper terminal. You can find that the
IP address is set to ‘192.168.11.20’ a fter ‘LI’ command executed correctly.
Attentions:
1) The ‘SV’ command must be executed if you want to save your new parameters.
2) The ‘RT’command must be executed if you want to execute your new parameters
3) The ‘EX’ command must be executed if you want to leave the serial configuration
mode.
WIZ107SR User Manual (WIZnet Co., Ltd.) 25
4) Example:
Refer to 1)~3), usually if you want to change the operation mode from Server to
Client, you should input something like this:
OP0 --->SV--->RT
Please, note that the data connection will be closed once the WIZ107SR goes into serial
configuration mode.
Figure 13. Serial command executing example
Attentions:
1) The ‘SV’ command must be executed with some delay (about 50ms) for WIZ107SR’s
stable operation.
2) Recommend to use the serial commands with some delay (about 10ms) for stable
operation
3) After execute serial command, We recommend to check the parameters using
response serial command like “LI\r\n”.
Example
Input> LI192.16 8.11.2\r\n
Input> LI\r\n
Output> LI192.168.11. 2
WIZ107SR User Manual (WIZnet Co., Ltd.) 26
4. Hardware Specification
4.1 WIZ107SR Dimension
A 30.00 B 3.50 C 11.50 D 11.50
E 3.50 F 3.00 G 3.50 H 38.00
I 3.50 J 48.00 K 2.54 L 2.73
M 8.65 N 2.54
Figure 14. WIZ107SR Dimensions (unit : mm)
WIZ107SR User Manual (WIZnet Co., Ltd.) 27
4.2 WIZ107SR Interface Board Schematic
Figure 15. WIZ107SR Interface Board Schematic
WIZ107SR User Manual (WIZnet Co., Ltd.) 28
4.3 Booting Time
H/W
version Firmware Version Bo oting Time
Rev 1.1
~ v1.93 70ms
v2.1 ~ v2.13 70ms + (400ms)
v2.14 ~ 70ms
Rev 1.3 ~ v3.04 70ms + (400ms)
v3.06 ~ v3.14 70ms
Rev 1.4 v4.03 ~ 70ms
Table 6. WIZ107SR’s Boot ing Time
4.4 HW_TRIG PIN
The way of detection connect status is monitoring the HW_TRIG Pin. When the connection is
established, HW_TRIG pin goes Low. And, it will go HIGH when connection is closed. Actually,
this pin works both direction, like Input and Output.
In the initial time, this pin is INPUT for Hardware Trigger (for serial command mode).
After that, this pin is OUTP UT for connection status.
Figure 16. WIZ107SR’s Operation Flow
WIZ107SR User Manual (WIZnet Co., Ltd.) 29
5. Warranty
WIZnet Co., Ltd offers the following limited warranties applicable only to the original
purchaser. This offer is non-transferable.
WIZnet warrants our products and its parts against defects in materials and workmanship
under normal use for period of standard ONE(1) YEAR for the WIZ107SR board and labor
warranty after the date of original retail purchase. During this period, WIZnet will repair or
replace a defective produ cts or part free of charge.
Warranty Conditions:
1. The warranty applies only to products distributed by WIZnet or our official
distributors.
2. The warranty applies only to defects in material or workmanship as mentioned above
in 6.Warranty. The warranty applies only to defects which occur during normal use
and does not extend to damage to products or parts which results from alternation,
repair, modification, faulty installation or service by anyone other than someone
authorized by WIZnet Inc. ; damage to products or parts caused by accident, abuse,
or misuse, poor maintenance, mishandling, misapplication, or used in violation of
instructions furnished by us ; damage occurring in shipment or any damage caused by
an act of God, such as lightening or line surge.
Procedure for Obtaining W arranty Service
1. Contact an authorized distributors or dealer of WIZnet Inc. for obtaining an RMA
(Return Merchandise Authorization) request form within the applicable warranty
period.
2. Send the products to the distributors or dealers together with the completed RMA
request form. All products returned for warranty must be carefully repackaged in the
original packin g materials.
3. Any service issue, please contact to sales@wiznet.co.kr