Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES
Selection
Guide
U-shaped
Convergent
Reective
PM-64
PM-24
PM-44/
PM-54
434
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Cable extension
• Cable extension is possible up to an overall length of
100 m 328.084 ft with a 0.3 mm2, or more, cable.
However, since a voltage drop shall occur due to the
cable extension, ensure that the power supply voltage
at the end of the cable attached to the sensor or at the
sensor terminals is within the rating.
Supply voltage:
4.5 V or more
Extension cable
Output
+
5 to 24V DC
±10 %
–
0 V
+V
Total cable length 100 m 328.084 ft
Connector
attached cable
But, when the overall cable length, including the cable
attached to the sensor, is as given below, there is no
need to conrm the voltage.
Conductor cross-
section area of
extension cable
Total cable length
0.08 to 0.1 mm2Up to 5 m 16.404 ft
0.2 mm2Up to 10 m 32.808 ft
0.3 mm2Up to 20 m 65.617 ft
Others
• Since the sensor is intended for
use inside machines, no special
countermeasures have been
taken against extraneous light.
Take care that extraneous light is
not directly incident on the beam
receiving section.
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
• If the sensor is used in a place having excessive dust,
periodically clean the emitting and receiving sections with
a dry, soft cloth.
• If there is a large surge generating equipment, such as,
motor, solenoid, electromagnetic valve, etc., in the vicinity
of the sensor, use a surge absorber on that equipment.
Further, do not run the sensor cables along power lines
and use a capacitor between +V and 0 V, if required.
Use the sensor after conrming that the surge has been
eliminated.
Mounting
• When xing the sensor with screws, use M3 screws and
the tightening torque should be 0.5 N·m or less.
Further, use small, round type plain washers (ø6 mm
ø0.236 in).
Spring washer
Plain washer
Outer diameter
ø6 mm
ø0.236 in
)(
Wiring
Connection method
CN-14A(-R)-C□
Projection
<Connector>
Housing: PAP-04V-S
Manufactured by J.S.T.
Mfg. Co., Ltd.
)(
• Insert the connector attached cable
CN-14A(-R)-C□ in the connector part
of this product as shown in the right
gure.
<Connector pin position>
Connector pin No.
Terminal designation
+V 0V
Output 1Output 2
1
1234
234
Disconnection method
• Pressing the projection of the connector attached cable,
pull out the connector.
Note: Take care that if the cable is pulled out without pressing the projection,
the cable may break.
PRECAUTIONS FOR PROPER USE Refer to p.1458~ for general precautions.
Make sure to connect terminals correctly as the
sensor does not incorporate a reverse polarity
protection circuit.
Further, the output is not incorporated with a
short-circuit protection circuit. Do not connect it
directly to a power supply or a capacitive load.
Faulty wiring may result in damage.
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.