351Varispeed J7
CIMR-J7AZ
Varispeed J7
Small, simple and smart
V/f controlled inverter
Compact size
Good torque performance: 100% torque at 1.5 Hz,
150% at 3 Hz
150% overload / 60sec
Overload detection function.
Motor thermal function
Freely configurable V/f curve
4 programmable digital input
1 programmable digital output
1 programmable analog output
Optional RS-232C/485 communication - Modbus
PC Configuration tool: CX-drive
CE, UL, and cUL marking
Ratings
200 V class single-phase 0.1 to 1.5 kW
200 V class three-phase 0.1 to 4.0 kW
400 V class three-phase 0.2 to 4.0 kW
System configuration
SI-232/J7
SI-232/J7C
SI-485/J7
3G3IV-PCN329-E
Inverter to PC cable
3G3IV-PCN126/326
Digital operator
extension cable
3G3IV-PEZZ8122_
DIN attachment
JVOP-144
Remote digital oper.
with potentiometer
CX-Drive
Line filter
Varispeed
J7
JVOP-146
Remote digital oper.
with potentiometer
Y203-EN2-02-Katalog.book Seite 351 Mittwoch, 24. Mai 2006 2:22 14
352 Frequency inverters
Type designation
Specifications
Voltage class 200 V single/three-phase 400 V three-phase
Model CIMR-J7AZ#Three-phase 20P1 20P2 20P4 20P7 21P5 22P2 24P0 40P2 40P4 40P7 41P5 42P2 43P0 44P0
Single-phase1
1. Single-phase series inverter output is three-phase (for three-phase motors)
B0P1B0P2B0P4B0P7B1P5–––––––––
Max. applicable
motor output kW (HP)2
2. Based on a standard 4-pole motor for max. applicable motor output. Select the inverter model whose rated current is larger than motor rated current.
0.12 0.25 0.55 1.1 1.5 2.2 4.0 0.37 0.55 1.1 1.5 2.2 3.0 4.0
Output
characteristics
Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7 0.9 1.4 2.6 3.7 4.2 5.5 7.0
Rated output current A 0.8 1.6 3 5 8 11 17.5 1.2 1.8 3.4 4.8 5.5 7.2 9.2
Max. output voltage V 3-phase, 200 to 230 V (proportional to input voltage)
Single-phase, 200 to 240 V (proportional to input voltage) 3-phase, 380 to 460 V (proportional to input voltage)
Max. output frequency 400 Hz (programmable)
Power
supply
Rated input voltage
and frequency 3-phase, 200 to 230 V, 50/60 Hz
Single-phase, 200 to 240 V, 50/60 Hz 3-phase, 380 to 460 V, 50/60 Hz
Allowable voltage
function –15 to +10%
Allowable frequency
function ±5%
Voltage
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
Z: European standard
specifications
Inverter
J7 series
A: With digital operator (with potentiometer)
CIMR—J7AZ20P1
Max. applicable motor output
0P1: 0.1 kW
4P0: 4.0 kW
~
"P" indicates a decimal
point
[ ]
Y203-EN2-02-Katalog.book Seite 352 Mittwoch, 24. Mai 2006 2:22 14
Varispeed J7 353
Commom specifications
Model
CIMR-J7AZ#Specifications
Control functions
Control method Sine wave PWM (V/f control)
Output frequency range 0.1 to 400 Hz
Frequency tolerance Digital reference: ±0.01% (–10 to +50 °C),
Analog reference: ±0.5% (25±10 °C)
Resolution of frequency set value Digital reference: 0.01 Hz (less than 100 Hz), 0.1 Hz (100 Hz or more)
Analog reference: 1/1000 of max. output frequency
Resolution of output frequency 0.01 Hz
Overload capability 150% rated output current for one minute
Frequency set value 0 to 10 VDC (20 kΩ), 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω), frequency setting volume (selectable)
Accel/decel time 0.1 to 999 sex. (accel/decel time are independently programmed)
Braking torque Short-term average deceleration torque1: 0.1, 0.2 kW (0.13 HP, 0,25 HP): 150% or more;
0.4/0.75 kW (0,5 HP, 1HP): 100% or more;
1.5 kW (2 HP): 50% or more;
2.2 kW (3 HP) or more: 20% or more
Continuous regenerative torque: Approx 20%
1. Shows deceleration torque for uncoupled motor decelerating from 60 Hz with the shortest possible deceleration time.
V/f characteristics Possible to program any V/f pattern
Functionality
Digital inputs Four of the following input signals are selectable: forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
contact input), multi-step speed operation, jog command, accel/decel time select, external baseblock (NO/NC contact input),
speed search command, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/
control circuit terminal selection, emergency stop fault, emergency stop alarm, self test
Digital outputs Following output signals are selectable (NO/NC contact output): Fault, running, zero speed, speed agreed,
frequency detection (output frequency or set value), during overtorque detection, minor error, during baseblock,
operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search,
data output through communication
Standard functions Full-range automatic torque boost, slip compensation, 9-step speed operation (max.), restart after momentary power loss,
DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, fault
retry, speed search, frequency upper/lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/
decel prohibited, S-curve accel/decel, frequency reference with built-in volume, constants copy (option) MEMOBUS commu-
nications (option)
Display Status indicator LED: RUN and ALARM provided as standard LED’s
Digital operator: available to monitor frequency reference, output frequency, output current
Protection
Motor overload protection Electronic thermal overload relay
Instantaneous overcurrent Motor coasts to a stop at approx. 250% of inverter rated current
Overload Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Overvoltage Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Undervoltage Stops when DC bus voltage is approx. 200 V or less (double for 400 V class)
(approx. 160 V or less for single-phase series)
Momentary power loss Following items are selectable: Nnot provided (stop if power loss is 15ms or longer),
continuous operation if power loss is approx. 0.5 s or shorter, continuous operation
Cooling fin overheat Protected by thermister
Stall prevention level Individual level stall prevention can be set during acceleration or constant running,
provided/not provided setting available during deceleration.
Cooling fan fault Detected by electronic circuit (fan lock detection)
Ground fault Protected by electronic circuit (operation level is approx. 250% of rated output current)
Power charge indication ON until the DC bus voltage becomes 50 V or less, RUN lamp stays ON or digital operator LED stays ON.
(Charge LED is provided for 400 V)
Ambient conditions
Degree of protection IP20
Cooling Self cooling for 200 V 0,1..0,75 kW (single-phase) 0,1..0,4 kW (Three-phase) and for 400 V 0,2..0,75l kW
Cooling fan for 200 V (single-phase), 0.75 kW..4.0 kW (3-phase) and for 400 V 1,5..4.0 kW
Ambient temperature -10 ºC to 50 ºC (non-freezing)
Ambient humidity 90% RH or less (non-condensing)
Storage temperature -20 ºC..+60 ºC (short-term temperature during trasnportation)
Installation Indoor (no corrosive gas, dust, etc.)
Installation height Max. 1000 m
Vibration 10 to 20 Hz, 9.8 m/s2 max; 20 to 50 Hz, 2m/s2 max
Y203-EN2-02-Katalog.book Seite 353 Mittwoch, 24. Mai 2006 2:22 14
354 Frequency inverters
Digital operator
Data display
Increment key
Increase constant no. or data.
Switch functions among function
display LEDs.
Decrement key
Decrease constant no. or data.
Enter key
Enter data when setting constants.
After selecting constant no. at
PRGM mode, data are displayed.
Display selection key
Digital operator
Function display LEDs
Selected function is lit (see the
functions below). Its data is
displayed on data display.
Operation key
Press to run the motor. The RUN
light is ON while running.
Stop/Reset key
Press to stop the motor. If fault
occurs, reset the inverter.
Frequency setting volume
Set operational frequency with
volume.
Run LED
Alarm LED
Frequency reference
setting/monitoring
FREF
Output frequency
monitoring
FOUT
Output current
monitoring
IOUT
Multi-function
monitoring
MNTR
Operator RUN command
FWD/REV selection
F/R
LOCAL/REMOTE
selection
LO/RE
Constant no./data
PRGM
Y203-EN2-02-Katalog.book Seite 354 Mittwoch, 24. Mai 2006 2:22 14
Varispeed J7 355
IP 20 type 0.1 to 4 kW
Dimensions
Voltage class Max. applicable
motor output kW Inverter model
CIMR-J7AZ#Figure Dimensions in mm Weight kg Cooling
method
W H D W1 H1 H2
200 V
three-phase
0.12 20P1 1 68 128 70 56 118 5 0.5 Self cooled
0.25 20P2 7.7
0.55 20P4 102 0.8
1.1 20P7 122 0.9 Fan cooled
1.5 21P5 2 108 129 96 118 1.3
2.2 22P2 154 1.5
4.0 24P0 140 161 128 2.1
200 V
single-phase
0.1 B0P1 1 68 128 70 56 118 5 0.5 Self cooled
0.2 B0P2
0.4 B0P4 112 0.9
0.75 B0P7 2 108 129 96 1.5 Fan cooled
1.5 B1P5 154
400 V
three-phase
0.37 40P2 2 108 128 81 96 118 5 1.0 Self cooled
0.55 40P4 99 1.1
1.1 40P7 129 1.5
1.5 41P5 154
2.2 42P2 Fan cooled
3.0 43P0 140 161 128 2.1
4.0 44P0
8.5
(0.34)
8.5
(0.34)
2
M
44
M
4
Figure 1 Figure 2
Y203-EN2-02-Katalog.book Seite 355 Mittwoch, 24. Mai 2006 2:22 14
356 Frequency inverters
Filters
Schaffner model Dimensions
A B C D E F G H I J K L
3x200 V 3G3JV-PFI2010-SE 194 82 50 160 181 62 5.3 M5 25 56 118 M4
3G3JV-PFI2020-SE 169 111 50 135 156 91 5.5 M5 25 96 118 M4
1x200 V 3G3JV-PFI1010-SE 169 71 45 135 156 51 5.3 M5 22 56 118 M4
3G3JV-PFI1020-SE 169 111 50 135 156 91 5.3 M5 25 96 118 M4
3x400 V 3G3JV-PFI3005-SE 169 111 50 135 156 91 5.3 M5 22 96 118 M4
3G3JV-PFI3010-SE 169 111 50 135 156 91 5.3 M5 22 96 118 M4
3G3JV-PFI3020-SE 174 144 50 135 61 120 5 M5 28 128 118 M4
Rasmi model Dimensions
W H L X Y Inverter fixing
3x200 V 3G3JV-PFI2010-E 82 50 194 181 62 M5
3G3JV-PF2020-E 111 50 169 156 91 M5
3G3JV-PFI2030-E 144 50 174 161 120 M5
1x200 V 3G3JV-PFI1010-E 71 45 169 156 51 M5
3G3JV-PFI1020-E 111 50 169 156 91 M5
3x400 V 3G3JV-PFI3005-E 111 50 169 156 91 M5
3G3JV-PFI3010-E 111 50 169 156 91 M5
3G3JV-PFI3020-E 144 50 174 161 120 M5
Drive mounts
Output
flexes
Y203-EN2-02-Katalog.book Seite 356 Mittwoch, 24. Mai 2006 2:22 14
Varispeed J7 357
DIN rail mounting bracket
Inverter DIN rail mounting bracket
3-phase 200 VAC CIMR-J7AZ20P1/20P2/20P4/20P7 3G3IV-PEZZ08122A
CIMR-J7AZ21P5/22P2 3G3IV-PEZZ08122B
CIMR-J7AZ24P0 3G3IV-PEZZ08122C
Single-phase 200 VAC CIMR-J7AZB0P1/B0P2/B0P4 3G3IV-PEZZ08122A
CIMR-J7AZB0P7/B1P5 3G3IV-PEZZ08122B
3-phase 400 VAC CIMR-J7AZ40P2/40P4/40P7/41P5/42P2 3G3IV-PEZZ08122B
CIMR-J7AZ43P0/44P0 3G3IV-PEZZ08122C
3G3IV-PEZZ08122A 3G3IV-PEZZ08122B
(35.1)
DIN rail
Four, M4 tap Four, M4 tap
(35.1)
DIN rail
3G3IV-PEZZ08122C
Four, M4 tap
Y203-EN2-02-Katalog.book Seite 357 Mittwoch, 24. Mai 2006 2:22 14
358 Frequency inverters
Standard connections
Installation
UX
MCCB
R
S
T
Varispeed J7AZ
2 k
Ω
PP
AM
AC
0 To 10 VDC (2 mA)
PFM
+2 +1 -
U/T1
V/T2
W/T3
R/L1
S/L2
T/L3
S1
S2
S3
S4
S5
FS
FR
FC
SC
0 To 10 V (20 k
Ω
) or 4 to 20mA (250
Ω
)
or O to 20 mA (250
Ω
)
0V
MA
MB
MC
IM
indicates twisted pair
shielded wire.
indicates shielded wire.
P
: shows the connection for the following two kinds of sequence input (S1 to S5)
signals: no-voltage contact and NPN transistors (0 V common).
For a PNP transistor (+24 V common), a 24 V external power supply is necessary.
DC reactor (option)
Forward run/stop
Reverse run/stop
External fault
(no contact)
Fault reset
Multi-step speed
reference 1
Multi-
function
input
Frequency
reference
Frequency setter
Frequency meter
adjusting potentiometer
Analog monitor
output
Output frequency
Digital operator
frequency
setting
volume
min
max
Shield connection
terminal
Speed reference
pulse train
(33 kHz max.)
Frequency setting power
supply (+12 V 20 mA)
Speed frequency reference
Running
Grounding
Multi-function
output
250 VAC 1 A or less
30 VDC 1 A or less
Pulse train input
short
bar
Y203-EN2-02-Katalog.book Seite 358 Mittwoch, 24. Mai 2006 2:22 14
Varispeed J7 359
Main circuit
Control circuit
Terminal Name Function (signal level)
R/L1, S/L2, T/L3 AC power supply input Main circuit power supply input (Use R/L1 and S/L2 for single-phase power supply inverter.
Do not use T/L3 of the models less than 0.75kW for other usage, such as a junction terminal.)
U/T1, V/T2, W/T3 Inverter output For inverter output
+2, +1 DC reactor connection Remove the short bar between +2 and +1 when connecting DC reactor (option)
+1, – DC power supply input For power supply input (+1: positive electrode; – : negative electrode)*
Grounding For grounding (grounding should conform to the local grounding code.)
Type No. Signal name Function Signal level
Digital input signals
S1 Multi-function input selection 1 Factory setting: runs when CLOSED, stops when OPEN. 24VDC, 8mA
photocoupler
isolation
S2 Multi-function input selection 2 Factory setting: runs when CLOSED, stops when OPEN.
S3 Multi-function input selection 3 Factory setting: "fault reset"
S4 Multi-function input selection 4 Factory setting: "external fault (NO contact)"
S5 Multi-function input selection 5 Factory setting: "multi-step speed reference 1"
SC Multi-function input selection
common Common for control signal
Analog
input
signals
FS Power supply terminal for
frequency setting +12V (allowable current: 20 mA max.)
FR Speed frequency reference 0 to +10 VDC (20 kΩ) or 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) (resolution 1/1000)
FC Frequency reference common 0 V
Digital
output
signals
MA NO contact output Factory setting: "running" Contact capacity
250 VAC, 1A or less
30 VDC, 1A or less
MB NC contact output
MC Contact output common
Analog
output
signals
AM Analog monitor output Factory setting: "output frequency" 0 to +10 V output 0 to 10 V 2 mA or less
Resolution: 8bits
AC Analog monitor common 0 V
Y203-EN2-02-Katalog.book Seite 359 Mittwoch, 24. Mai 2006 2:22 14
360 Frequency inverters
Inverter heat loss
Three-phase 200 V class
Single-phase 200 V class
Three-phase 400 V class
CIMR-J7AZ#20P1 20P2 20P4 20P7 21P5 22P2 24P0
Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7
Rated current A 0.8 1.6 3.0 5.0 8.0 11.0 17.5
Heat
loss W
Fin 3.7 10.3 15.8 28.4 53.7 60.4 96.7
Inside unit 9.3 18.0 12.3 16.7 19.1 34.4 52.4
Total heat loss 13.0 18.0 28.1 45.1 72.8 94.8 149.1
CIMR-J7AZ#B0P1 B0P2 B0P4 B0P7 B1P5
Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0
Rated current A 0.8 1.6 3.0 5.0 8.0
Heat
loss W
Fin 3.7 7.7 15.8 28.4 53.7
Inside unit 10.4 12.3 16.1 23.0 29.1
Total heat loss 14.1 20.1 31.9 51.4 82.8
CIMR-J7AZ#40P2 40P4 40P7 41P5 42P2 43P0 44P0
Inverter capacity kVA 0.9 1.4 2.6 3.7 4.2 5.5 7.0
Rated current A 1.2 1.8 3.4 4.8 5.5 7.2 9.2
Heat
loss W
Fin 9.4 15.1 30.3 45.8 50.5 58.2 73.4
Inside unit 13.7 15.0 24.6 29.9 32.5 37.6 44.5
Total heat loss 23.7 30.1 54.9 75.7 83.0 95.8 117.9
W=
Inverter Inverter Inverter
50 mm min. (5.5 and 7.5 KW)
30 mm min. (0.1 to 4.0 KW) 100 mm min.
100 mm min.
Side
Air
Air
Y203-EN2-02-Katalog.book Seite 360 Mittwoch, 24. Mai 2006 2:22 14
Varispeed J7 361
AC reactor
DC reactor
200 V class 400 V class
Max. applicable
motor output kW Current value
AInductance
mH Max. applicable
motor output kW Current value
AInductance
mH
0.1 2.0 2.0 ------
0.22.02.00.21.3 18.0
0.42.54.20.4
0.75 5 2.1 0.75 2.5 8.4
1.5 10 1.1 1.5 5 4.2
2.2 15 0.71 2.2 7.5 3.6
4.0 20 0.53 4.0 10 2.2
200 V class 400 V class
Max. applicable
motor output kW Current value
AInductance
mH Max. applicable
motor output kW Current value
AInductance
mH
0.12 5.4 8 --------
0.25 0.37 3.2 28
0.55 0.55
1.1 1.1
1.5 18 3 1.5 5.7 11
2.2 2.2
4.0 4.0 12 6.3
L1(R) U
V
W
X
Y
Z
L2(S)
L3(T)
L1(R)
L2(S)
L3(T)
T1(U)
T2(V)
T3(W)
CIMR-J7AZ
MCCB Motor
AC reactor
IM
Be sure to connect
AC reactor on inverter
input side [L1 (R),
L2 (S), L3 (T)].
CIMR-J7AZ
DC reactor
Motor
MCCB
Y203-EN2-02-Katalog.book Seite 361 Mittwoch, 24. Mai 2006 2:22 14
362 Frequency inverters
Varispeed J7
200 V 400 V
Ordering information
A
B
B
SI-232/J7
SI-232/J7C
SI-485/J7
3G3IV-PCN329-E
Inverter to PC cable
3G3IV-PCN126/326
Digital operator
extension cable
3G3IV-PEZZ8122_
DIN attachment
JVOP-144
Remote digital oper.
with potentiometer
CX-Drive
Line filter
Varispeed
J7
JVOP-146
Remote digital oper.
with potentiometer
Specifications Model
1x200 V 0.12 Kw 0.8 A CIMR-J7AZB0P10
0.25 Kw 1.6 A CIMR-J7AZB0P20
0.55 Kw 3.0 A CIMR-J7AZB0P40
1.1 Kw 5.0 A CIMR-J7AZB0P70
1.5 Kw 8.0 A CIMR-J7AZB1P50
3x200 V 0.12 Kw 0.8 A CIMR-J7AZ20P10
0.25 Kw 1.6 A CIMR-J7AZ20P20
0.55 Kw 3.0 A CIMR-J7AZ20P40
1.1 Kw 5.0 A CIMR-J7AZ20P70
1.5 Kw 8.0 A CIMR-J7AZ21P50
2.2 Kw 11.0 A CIMR-J7AZ22P20
4.0 Kw 17.5 A CIMR-J7AZ24P00
Specifications Model
3x400 V 0.37 Kw 1.2 A CIMR-J7AZ40P20
0.55 Kw 1.8 A CIMR-J7AZ40P40
1.1 Kw 3.4 A CIMR-J7AZ40P70
1.5 Kw 4.8 A CIMR-J7AZ41P50
2.2 Kw 5.5 A CIMR-J7AZ42P20
3.0 Kw 7.2 A CIMR-J7AZ43P00
4.0 Kw 9.2 A CIMR-J7AZ44P00
Y203-EN2-02-Katalog.book Seite 362 Mittwoch, 24. Mai 2006 2:22 14
Varispeed J7 363
ALine filters
B Accessories
Inverter Line filter
Voltage Model CIMR-J7AZ Schaffner Rasmi Rated current (A) Weight (kg)
3-phase 200 VAC
20P1 / 20P2 / 20P4 / 20P7 3G3JV-PFI2010-SE 3G3JV-PFI2010-E 10 0.68
21P5 / 22P2 3G3JV-PFI2020-SE 3G3JV-PFI2020-E 16 0.84
24P0 --- 3G3JV-PFI2030-E 26 1.0
Single-phase 200 VAC B0P1 / B0P2 / B0P4 3G3JV-PFI1010-SE 3G3JV-PFI1010-E 10 0.45
B0P7 / B1P5 3G3JV-PFI1020-SE 3G3JV-PFI1020-E 20 0.68
3-phase 400 VAC
40P2 / 40P4 3G3JV-PFI3005-SE 3G3JV-PFI3005-E 5 0.57
40P7 / 41P5 / 42P2 3G3JV-PFI3010-SE 3G3JV-PFI3010-E 10 0.67
43P0 / 44P0 3G3JV-PFI3020-SE 3G3JV-PFI3020-E 20 / 15 1.0
Type Model Description Funtions
Digital operator
JVOP-146
Remote digital operator
without potentiometer
JVOP-144
Remote digital operator
with potentiometer
DATA (15.5)
STOP
78 (3.07) 18.2
(0.72)
88 (3.46)
5
(0.2)
80 (3.15)
4-4.4 dia. MTG holes
58 (2.28)
11
(0.43)
155(061)
23.1
(0.91)
50 (1.97)
10.5
(0.41)
30.4
(1.20)
1.7
(0.07)
12.2
(0.48)
68 (2.68)
56 (2.20)
4-M4 spot facing
deep 3.5 (0.14)
DSPL
STOP
RESET
DATA
ENTER
78 (3.07) 18.2
(0.72)
88 (3.46)
5
(0.2)
80 (3.15)
4-4.4 dia. MTG holes
58 (2.28)
11
(0.43)
15.5 (0.61)
23.1
(0.91)
50 (1.97)
10.5
(0.41)
30.4
(1.20)
68 (2.68)
56 (2.20)
4-M4 spot facing
deep 3.5 (0.14)
RUN
DIGITAL
OPERATOR
JVOP-140
MIN MAX
12.2 (0.48)
12.2 (0.48)
12.2 (0.48)
9.3 (0.37)
9.3 (0.37)
9.3 (0.37)
1.7 (0.07)
1.7 (0.07)
1.7 (0.07)
Y203-EN2-02-Katalog.book Seite 363 Mittwoch, 24. Mai 2006 2:22 14
364 Frequency inverters
B Accessories
Interface units
SI-232/J7 (3G3JV-PSI232J)
RS232 adapter
Another option SI-232/J7C (3G3JV-PSI232JC) is available, the only difference is
that this one is removable.
SI-485/J7 (3G3JV-PSI485J)
RS485 adapter
Accessories
3G3IV-PCN126
3G3IV-PCN326 Digital operator extension cable
1 meter
3 meters
SI232/J7 must be connected
3G3IV-PCN329-E PC configuration cable SI232/J7 must be connected
Type Model Description Installation
Software
CX-drive Computer software Configuration and monitoring software tool for drives.
CX-One Computer software Complete OMRON automation software including CX-drive.
Type Model Description Funtions
21.5
(0.85)
2.5
(0.1) 19
(0.75)
63(2.48) 8(0.31
15.5
(0.61)
16
(0.63)
29
(1.14)
12
(0.47)
819
(0.3) (0.75) (0.3)
63
(2.48)
13(0.51)
16(0.63)
29
(1.14)
4 3.8(0.15)=15.2(0.6)
8
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I19E-EN-02
Y203-EN2-02-Katalog.book Seite 364 Mittwoch, 24. Mai 2006 2:22 14
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
CIMR-J7AZ-22P20 CIMR-J7AZ-B0P20 CIMR-J7AZB0P20 CIMR-J7AZ22P20