Y203-EN2-02-Katalog.book Seite 351 Mittwoch, 24. Mai 2006 2:22 14 CIMR-J7AZ Varispeed J7 Small, simple and smart * V/f controlled inverter * Compact size * Good torque performance: 100% torque at 1.5 Hz, 150% at 3 Hz * 150% overload / 60sec * Overload detection function. * Motor thermal function * Freely configurable V/f curve * 4 programmable digital input * 1 programmable digital output * 1 programmable analog output * Optional RS-232C/485 communication - Modbus * PC Configuration tool: CX-drive * CE, UL, and cUL marking Ratings * 200 V class single-phase 0.1 to 1.5 kW * 200 V class three-phase 0.1 to 4.0 kW * 400 V class three-phase 0.2 to 4.0 kW System configuration SI-485/J7 SI-232/J7 SI-232/J7C CX-Drive JVOP-144 Remote digital oper. with potentiometer Line filter JVOP-146 Remote digital oper. with potentiometer 3G3IV-PEZZ8122_ DIN attachment 3G3IV-PCN329-E Inverter to PC cable 3G3IV-PCN126/326 Digital operator extension cable Varispeed J7 Varispeed J7 351 Y203-EN2-02-Katalog.book Seite 352 Mittwoch, 24. Mai 2006 2:22 14 Specifications Type designation CIMR--J7AZ20P1 Inverter Max. applicable motor output 0P1: 0.1 kW ~ J7 series 4P0: 4.0 kW [ A: With digital operator (with potentiometer) Z: European standard specifications Voltage class 200 V single/three-phase Output characteristics Power supply 400 V three-phase 20P1 20P2 20P4 20P7 21P5 22P2 24P0 40P2 40P4 40P7 41P5 42P2 43P0 Single-phase1 B0P1 B0P2 B0P4 B0P7 B1P5 - - - - - - - - - 0.12 0.25 0.55 1.1 1.5 2.2 4.0 0.37 0.55 1.1 1.5 2.2 3.0 4.0 Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7 0.9 1.4 2.6 3.7 4.2 5.5 7.0 Rated output current A 0.8 1.6 3 5 8 11 17.5 1.2 1.8 3.4 4.8 5.5 7.2 9.2 Max. applicable motor output kW (HP)2 352 Voltage B: Single-phase 200 VAC 2: Three-phase 200 VAC 4: Three-phase 400 VAC Three-phase Model CIMR-J7AZ# 1. 2. ] "P" indicates a decimal point Max. output voltage V Max. output frequency Rated input voltage and frequency 3-phase, 200 to 230 V (proportional to input voltage) Single-phase, 200 to 240 V (proportional to input voltage) 44P0 3-phase, 380 to 460 V (proportional to input voltage) 400 Hz (programmable) 3-phase, 200 to 230 V, 50/60 Hz Single-phase, 200 to 240 V, 50/60 Hz 3-phase, 380 to 460 V, 50/60 Hz Allowable voltage function -15 to +10% Allowable frequency function 5% Single-phase series inverter output is three-phase (for three-phase motors) Based on a standard 4-pole motor for max. applicable motor output. Select the inverter model whose rated current is larger than motor rated current. Frequency inverters Y203-EN2-02-Katalog.book Seite 353 Mittwoch, 24. Mai 2006 2:22 14 Commom specifications Model CIMR-J7AZ# Control method Output frequency range Control functions Frequency tolerance Resolution of frequency set value Resolution of output frequency Sine wave PWM (V/f control) 0.1 to 400 Hz Digital reference: 0.01% (-10 to +50 C), Analog reference: 0.5% (2510 C) Digital reference: 0.01 Hz (less than 100 Hz), 0.1 Hz (100 Hz or more) Analog reference: 1/1000 of max. output frequency 0.01 Hz Overload capability 150% rated output current for one minute Frequency set value 0 to 10 VDC (20 k), 4 to 20 mA (250 ), 0 to 20 mA (250 ), frequency setting volume (selectable) Accel/decel time Braking torque V/f characteristics Digital inputs Digital outputs Functionality Specifications Standard functions Display 0.1 to 999 sex. (accel/decel time are independently programmed) Short-term average deceleration torque1: 0.1, 0.2 kW (0.13 HP, 0,25 HP): 150% or more; 0.4/0.75 kW (0,5 HP, 1HP): 100% or more; 1.5 kW (2 HP): 50% or more; 2.2 kW (3 HP) or more: 20% or more Continuous regenerative torque: Approx 20% Possible to program any V/f pattern Four of the following input signals are selectable: forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC contact input), multi-step speed operation, jog command, accel/decel time select, external baseblock (NO/NC contact input), speed search command, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/ control circuit terminal selection, emergency stop fault, emergency stop alarm, self test Following output signals are selectable (NO/NC contact output): Fault, running, zero speed, speed agreed, frequency detection (output frequency or set value), during overtorque detection, minor error, during baseblock, operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search, data output through communication Full-range automatic torque boost, slip compensation, 9-step speed operation (max.), restart after momentary power loss, DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, fault retry, speed search, frequency upper/lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/ decel prohibited, S-curve accel/decel, frequency reference with built-in volume, constants copy (option) MEMOBUS communications (option) Status indicator LED: RUN and ALARM provided as standard LED's Digital operator: available to monitor frequency reference, output frequency, output current Motor overload protection Electronic thermal overload relay Instantaneous overcurrent Motor coasts to a stop at approx. 250% of inverter rated current Overload Overvoltage Protection Undervoltage Momentary power loss Stops when DC bus voltage is approx. 200 V or less (double for 400 V class) (approx. 160 V or less for single-phase series) Following items are selectable: Nnot provided (stop if power loss is 15ms or longer), continuous operation if power loss is approx. 0.5 s or shorter, continuous operation Cooling fin overheat Protected by thermister Stall prevention level Individual level stall prevention can be set during acceleration or constant running, provided/not provided setting available during deceleration. Cooling fan fault Ground fault Power charge indication Degree of protection Ambient conditions Motor coasts to a stop after 1 minute at 150% of inverter rated output current Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class) Cooling Ambient temperature Ambient humidity Storage temperature Installation Installation height Vibration 1. Detected by electronic circuit (fan lock detection) Protected by electronic circuit (operation level is approx. 250% of rated output current) ON until the DC bus voltage becomes 50 V or less, RUN lamp stays ON or digital operator LED stays ON. (Charge LED is provided for 400 V) IP20 Self cooling for 200 V 0,1..0,75 kW (single-phase) 0,1..0,4 kW (Three-phase) and for 400 V 0,2..0,75l kW Cooling fan for 200 V (single-phase), 0.75 kW..4.0 kW (3-phase) and for 400 V 1,5..4.0 kW -10 C to 50 C (non-freezing) 90% RH or less (non-condensing) -20 C..+60 C (short-term temperature during trasnportation) Indoor (no corrosive gas, dust, etc.) Max. 1000 m 10 to 20 Hz, 9.8 m/s2 max; 20 to 50 Hz, 2m/s2 max Shows deceleration torque for uncoupled motor decelerating from 60 Hz with the shortest possible deceleration time. Varispeed J7 353 Y203-EN2-02-Katalog.book Seite 354 Mittwoch, 24. Mai 2006 2:22 14 Digital operator Digital operator Function display LEDs Selected function is lit (see the functions below). Its data is displayed on data display. Data display Operation key Display selection key Press to run the motor. The RUN light is ON while running. Switch functions among function display LEDs. Alarm LED Enter key Enter data when setting constants. After selecting constant no. at PRGM mode, data are displayed. Run LED Increment key Frequency setting volume Increase constant no. or data. Set operational frequency with volume. Decrement key Decrease constant no. or data. Stop/Reset key Press to stop the motor. If fault occurs, reset the inverter. FREF FOUT Frequency reference Output frequency setting/monitoring monitoring 354 IOUT MNTR Output current monitoring Multi-function monitoring F/R LO / RE PRGM Operator RUN command FWD/REV selection LOCAL/REMOTE selection Constant no./data Frequency inverters Y203-EN2-02-Katalog.book Seite 355 Mittwoch, 24. Mai 2006 2:22 14 Dimensions IP 20 type 0.1 to 4 kW 4-M4 2-M4 8.5 (0.34) 8.5 (0.34) Figure 1 Voltage class 200 V three-phase 200 V single-phase 400 V three-phase Varispeed J7 Figure 2 Max. applicable motor output kW Inverter model CIMR-J7AZ# Figure 0.12 20P1 1 0.25 20P2 Dimensions in mm W H D W1 H1 H2 68 128 70 56 118 5 Weight kg Cooling method 0.5 Self cooled 7.7 0.55 20P4 102 0.8 1.1 20P7 122 0.9 1.5 21P5 2.2 22P2 4.0 24P0 0.1 B0P1 0.2 B0P2 0.4 B0P4 0.75 B0P7 1.5 B1P5 0.37 40P2 0.55 40P4 2 108 129 96 140 161 128 70 56 118 154 1 68 2 108 128 1.5 2.1 118 5 112 129 Fan cooled 1.3 0.5 Self cooled 0.9 96 1.5 Fan cooled 1.0 Self cooled 154 2 108 128 81 96 118 5 99 1.1 1.5 1.1 40P7 129 1.5 41P5 154 2.2 42P2 3.0 43P0 4.0 44P0 Fan cooled 140 161 128 2.1 355 Y203-EN2-02-Katalog.book Seite 356 Mittwoch, 24. Mai 2006 2:22 14 Filters Dimensions Schaffner model 3x200 V 1x200 V 3x400 V A B C D E F G H I J K L 3G3JV-PFI2010-SE 194 82 50 160 181 62 5.3 M5 25 56 118 M4 3G3JV-PFI2020-SE 169 111 50 135 156 91 5.5 M5 25 96 118 M4 3G3JV-PFI1010-SE 169 71 45 135 156 51 5.3 M5 22 56 118 M4 3G3JV-PFI1020-SE 169 111 50 135 156 91 5.3 M5 25 96 118 M4 3G3JV-PFI3005-SE 169 111 50 135 156 91 5.3 M5 22 96 118 M4 3G3JV-PFI3010-SE 169 111 50 135 156 91 5.3 M5 22 96 118 M4 3G3JV-PFI3020-SE 174 144 50 135 61 120 5 M5 28 128 118 M4 Drive mounts Output flexes Rasmi model 3x200 V 1x200 V 3x400 V 356 Dimensions W H L X Y 3G3JV-PFI2010-E 82 50 194 181 62 Inverter fixing M5 3G3JV-PF2020-E 111 50 169 156 91 M5 3G3JV-PFI2030-E 144 50 174 161 120 M5 3G3JV-PFI1010-E 71 45 169 156 51 M5 3G3JV-PFI1020-E 111 50 169 156 91 M5 3G3JV-PFI3005-E 111 50 169 156 91 M5 3G3JV-PFI3010-E 111 50 169 156 91 M5 3G3JV-PFI3020-E 144 50 174 161 120 M5 Frequency inverters Y203-EN2-02-Katalog.book Seite 357 Mittwoch, 24. Mai 2006 2:22 14 DIN rail mounting bracket 3G3IV-PEZZ08122A .1) DIN (35 Four, M4 tap rail (35 .1) DIN rail 3G3IV-PEZZ08122B Four, M4 tap 3G3IV-PEZZ08122C Four, M4 tap 3-phase 200 VAC Single-phase 200 VAC 3-phase 400 VAC Varispeed J7 Inverter CIMR-J7AZ20P1/20P2/20P4/20P7 CIMR-J7AZ21P5/22P2 CIMR-J7AZ24P0 CIMR-J7AZB0P1/B0P2/B0P4 CIMR-J7AZB0P7/B1P5 CIMR-J7AZ40P2/40P4/40P7/41P5/42P2 CIMR-J7AZ43P0/44P0 DIN rail mounting bracket 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 357 Y203-EN2-02-Katalog.book Seite 358 Mittwoch, 24. Mai 2006 2:22 14 Installation Standard connections DC reactor (option) short X bar U MCCB +1 R/L1 S S/L2 T T/L3 - U/T1 V/T2 Varispeed J7AZ Forward run/stop S1 Reverse run/stop Multifunction input +2 R W/T3 Grounding S2 Fault reset External fault (no contact) Multi-step speed reference 1 IM S3 MA S4 MB Running MC S5 Multi-function output 250 VAC 1 A or less 30 VDC 1 A or less SC Shield connection terminal Pulse train input Frequency setting power Frequency reference FS supply (+12 V 20 mA) 2 k Speed reference Speed frequency reference P P Frequency setter FR 0 To 10 V (20 k ) or 4 to 20mA (250 ) pulse train (33 kHz max.) FC or O to 20 mA (250 ) 0V Digital operator frequency setting min max volume AM AC Frequency meter adjusting potentiometer Analog monitor P FM output 0 To 10 VDC (2 mA) Output frequency indicates shielded wire. P indicates twisted pair shielded wire. : shows the connection for the following two kinds of sequence input (S1 to S5) signals: no-voltage contact and NPN transistors (0 V common). For a PNP transistor (+24 V common), a 24 V external power supply is necessary. 358 Frequency inverters Y203-EN2-02-Katalog.book Seite 359 Mittwoch, 24. Mai 2006 2:22 14 Main circuit Terminal R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 +2, +1 +1, - Name AC power supply input Function (signal level) Inverter output Main circuit power supply input (Use R/L1 and S/L2 for single-phase power supply inverter. Do not use T/L3 of the models less than 0.75kW for other usage, such as a junction terminal.) For inverter output DC reactor connection Remove the short bar between +2 and +1 when connecting DC reactor (option) DC power supply input For power supply input (+1: positive electrode; - : negative electrode)* Grounding For grounding (grounding should conform to the local grounding code.) Control circuit Type No. Digital input signals S1 S2 S3 S4 S5 Analog input signals SC FS FR FC Digital output signals MA MB Analog output signals MC AM AC Varispeed J7 Signal name Function Signal level Multi-function input selection 1 Factory setting: runs when CLOSED, stops when OPEN. 24VDC, 8mA photocoupler isolation Multi-function input selection 2 Factory setting: runs when CLOSED, stops when OPEN. Multi-function input selection 3 Factory setting: "fault reset" Multi-function input selection 4 Factory setting: "external fault (NO contact)" Multi-function input selection 5 Factory setting: "multi-step speed reference 1" Multi-function input selection common Power supply terminal for frequency setting Speed frequency reference Common for control signal Frequency reference common 0V NO contact output Factory setting: "running" Contact capacity 250 VAC, 1A or less 30 VDC, 1A or less Analog monitor output Factory setting: "output frequency" 0 to +10 V output 0 to 10 V 2 mA or less Resolution: 8bits Analog monitor common 0V +12V (allowable current: 20 mA max.) 0 to +10 VDC (20 k) or 4 to 20 mA (250 ), 0 to 20 mA (250 ) (resolution 1/1000) NC contact output Contact output common 359 Y203-EN2-02-Katalog.book Seite 360 Mittwoch, 24. Mai 2006 2:22 14 W= 30 mm min. (0.1 to 4.0 KW) 50 mm min. (5.5 and 7.5 KW) Inverter 100 mm min. Inverter Air Inverter Side 100 mm min. Air Inverter heat loss Three-phase 200 V class 20P1 20P2 20P4 20P7 21P5 22P2 0.3 0.6 1.1 1.9 3.0 4.2 6.7 Rated current A 0.8 1.6 3.0 5.0 8.0 11.0 17.5 96.7 Heat loss W CIMR-J7AZ# Inverter capacity kVA 24P0 Fin 3.7 10.3 15.8 28.4 53.7 60.4 Inside unit 9.3 18.0 12.3 16.7 19.1 34.4 52.4 Total heat loss 13.0 18.0 28.1 45.1 72.8 94.8 149.1 Single-phase 200 V class B0P1 B0P2 B0P4 B0P7 B1P5 0.3 0.6 1.1 1.9 3.0 Rated current A 0.8 1.6 3.0 5.0 8.0 Fin 3.7 7.7 15.8 28.4 53.7 Inside unit 10.4 12.3 16.1 23.0 29.1 Total heat loss 14.1 20.1 31.9 51.4 82.8 Heat loss W CIMR-J7AZ# Inverter capacity kVA Heat loss W Three-phase 400 V class 360 CIMR-J7AZ# 40P2 40P4 40P7 41P5 42P2 43P0 44P0 Inverter capacity kVA 0.9 1.4 2.6 3.7 4.2 5.5 7.0 Rated current A 1.2 1.8 3.4 4.8 5.5 7.2 9.2 Fin 9.4 15.1 30.3 45.8 50.5 58.2 73.4 Inside unit 13.7 15.0 24.6 29.9 32.5 37.6 44.5 Total heat loss 23.7 30.1 54.9 75.7 83.0 95.8 117.9 Frequency inverters Y203-EN2-02-Katalog.book Seite 361 Mittwoch, 24. Mai 2006 2:22 14 AC reactor AC reactor MCCB L1(R) L2(S) L3(T) U X V Y W Z Motor L1(R) T1(U) L2(S) T2(V) L3(T) T3(W) IM CIMR-J7AZ Be sure to connect AC reactor on inverter input side [L1 (R), L2 (S), L3 (T)]. 200 V class Max. applicable motor output kW 0.1 0.2 0.4 0.75 1.5 2.2 4.0 400 V class Max. applicable motor output kW Current value Inductance A mH 2.0 2.0 2.0 2.0 2.5 4.2 5 2.1 10 1.1 15 0.71 20 0.53 Current value Inductance A mH ------ 0.2 0.4 0.75 1.5 2.2 4.0 1.3 18.0 2.5 5 7.5 10 8.4 4.2 3.6 2.2 DC reactor DC reactor MCCB Motor CIMR-J7AZ 200 V class Max. applicable motor output kW 0.12 Current value A 5.4 Inductance mH 8 0.37 0.55 0.55 1.5 Current value A Inductance mH -------- 0.25 1.1 Varispeed J7 400 V class Max. applicable motor output kW 3.2 28 5.7 11 12 6.3 1.1 18 3 1.5 2.2 2.2 4.0 4.0 361 Y203-EN2-02-Katalog.book Seite 362 Mittwoch, 24. Mai 2006 2:22 14 Ordering information SI-485/J7 SI-232/J7 SI-232/J7C CX-Drive JVOP-144 Remote digital oper. with potentiometer JVOP-146 Remote digital oper. with potentiometer 3G3IV-PEZZ8122_ DIN attachment 3G3IV-PCN329-E Inverter to PC cable 3G3IV-PCN126/326 Digital operator extension cable B Line filter B Varispeed J7 A Varispeed J7 400 V 200 V Specifications 1x200 V 3x200 V 362 Specifications Model 3x400 V 0.37 Kw Model 1.2 A CIMR-J7AZ40P20 0.12 Kw 0.8 A CIMR-J7AZB0P10 0.25 Kw 1.6 A CIMR-J7AZB0P20 0.55 Kw 1.8 A CIMR-J7AZ40P40 0.55 Kw 3.0 A CIMR-J7AZB0P40 1.1 Kw 3.4 A CIMR-J7AZ40P70 1.1 Kw 5.0 A CIMR-J7AZB0P70 1.5 Kw 4.8 A CIMR-J7AZ41P50 1.5 Kw 8.0 A CIMR-J7AZB1P50 2.2 Kw 5.5 A CIMR-J7AZ42P20 0.12 Kw 0.8 A CIMR-J7AZ20P10 3.0 Kw 7.2 A CIMR-J7AZ43P00 4.0 Kw 9.2 A CIMR-J7AZ44P00 0.25 Kw 1.6 A CIMR-J7AZ20P20 0.55 Kw 3.0 A CIMR-J7AZ20P40 1.1 Kw 5.0 A CIMR-J7AZ20P70 1.5 Kw 8.0 A CIMR-J7AZ21P50 2.2 Kw 11.0 A CIMR-J7AZ22P20 4.0 Kw 17.5 A CIMR-J7AZ24P00 Frequency inverters Y203-EN2-02-Katalog.book Seite 363 Mittwoch, 24. Mai 2006 2:22 14 ALine filters Inverter Voltage 3-phase 200 VAC Single-phase 200 VAC 3-phase 400 VAC Line filter Model CIMR-J7AZ Schaffner Rasmi Rated current (A) Weight (kg) 20P1 / 20P2 / 20P4 / 20P7 3G3JV-PFI2010-SE 3G3JV-PFI2010-E 10 0.68 21P5 / 22P2 3G3JV-PFI2020-SE 3G3JV-PFI2020-E 16 0.84 24P0 --- 3G3JV-PFI2030-E 26 1.0 B0P1 / B0P2 / B0P4 3G3JV-PFI1010-SE 3G3JV-PFI1010-E 10 0.45 B0P7 / B1P5 3G3JV-PFI1020-SE 3G3JV-PFI1020-E 20 0.68 40P2 / 40P4 3G3JV-PFI3005-SE 3G3JV-PFI3005-E 5 0.57 40P7 / 41P5 / 42P2 3G3JV-PFI3010-SE 3G3JV-PFI3010-E 10 0.67 43P0 / 44P0 3G3JV-PFI3020-SE 3G3JV-PFI3020-E 20 / 15 1.0 B Accessories Type Model Description Funtions JVOP-146 1.7 5 (0.07) 12.2 (0.2) (0.48) 23.1 (0.91) 78 (3.07) 88 (3.46) 10.5 (0.41) 68 (2.68) (15.5) STOP Remote digital operator without potentiometer 56 (2.20) 18.2 30.4 (0.72) (1.20) 4-M4 spot facing deep 3.5 (0.14) 15 5 (0 61) JVOP-144 Remote digital operator with potentiometer RUN STOP RESET MIN MAX 78 (3.07) 88 (3.46) 5 (0.2) 1.7 (0.07) 12.2 (0.48) 23.1 (0.91) 9.3 (0.37) 10.5 (0.41) 18.2 30.4 (0.72) (1.20) 68 (2.68) DSPL DATA ENTER 50 (1.97) DIGITAL OPERATOR JVOP-140 80 (3.15) 4-4.4 dia. MTG holes 11 58 (2.28) (0.43) Digital operator 50 (1.97) DATA 80 (3.15) 58 (2.28) 11 (0.43) 4-4.4 dia. MTG holes 56 (2.20) 4-M4 spot facing deep 3.5 (0.14) 15.5 (0.61) Varispeed J7 363 Y203-EN2-02-Katalog.book Seite 364 Mittwoch, 24. Mai 2006 2:22 14 Type Model Description SI-232/J7 (3G3JV-PSI232J) Funtions Another option SI-232/J7C (3G3JV-PSI232JC) is available, the only difference is that this one is removable. 15.5 (0.61) 29 (1.14) 21.5 (0.85) 63(2.48) 2.5 19 (0.1) (0.75) 8(0.31 16 (0.63) 12 (0.47) 4 3.8(0.15)=15.2(0.6) 29 (1.14) SI-485/J7 (3G3JV-PSI485J) 13(0.51) Interface units RS232 adapter 63 (2.48) 8 19 8 (0.3) (0.75) (0.3) Accessories 16(0.63) RS485 adapter 3G3IV-PCN126 3G3IV-PCN326 3G3IV-PCN329-E Digital operator extension cable SI232/J7 must be connected 1 meter 3 meters PC configuration cable SI232/J7 must be connected B Accessories Software Type Model Description Installation CX-drive Computer software Configuration and monitoring software tool for drives. CX-One Computer software Complete OMRON automation software including CX-drive. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I19E-EN-02 364 In the interest of product improvement, specifications are subject to change without notice. Frequency inverters Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: CIMR-J7AZ-22P20 CIMR-J7AZ-B0P20 CIMR-J7AZB0P20 CIMR-J7AZ22P20