The PFC500 products of the PerFormanCe Power Series combine high performance midrange power with high power density (4.4 watts/in3) and high reliability to meet the requirements of communications, commercial, and industrial systems. Providing tightly regulated DC power, the PFC500 delivers full output performance with only 300 Linear Feet per Minute (LFM) forced-air cooling (factory-installed fan optional). Main channel current sharing is provided for redundant applications. Units are available with SAE mountings or optional metric mountings. The PFC500 product line is approved to the latest international regulatory standards, and displays the CE Mark. RoHS Compliant Power Factor Correction meets EN61000-3-2 (AC input versions) Fully-regulated outputs Remote sense Logic level Inhibit Current Share, Power Fail, and Power Good Signals Overtemperature, overvoltage, and overcurrent protected Available with metric or SAE mountings Input transient & ESD compliance to EN61000-4-2/-3/-4/-5 Fan output voltage and optional fan Optional isolation diodes for parallel or redundant operation DC input versions (36-75 VDC) Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 (c) 2015 Bel Power Solutions, Inc. North America +1 866 513 2839 BCD.00595_AB 2 MODEL5 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX. OUTPUT CURRENT2 LINE REGULATION LOAD REGULATION3 RIPPLE & NOISE % p-p4 INITIAL SETTING ACCURACY PFC500-1024G 24V 21.6V to 26.4V 21A 0.5% 0.2% 1% 23.88V to 24.12V PFC500-1028G 1 28V 25.2V to 30.8V 17.9A 0.5% 0.2% 1% 27.86V to 28.14V PFC500-1048G 1 48V 46.0V to 56.0V 10.4A 0.5% 0.5% 1% 47.52V to 48.48V NOTES: 1 2 3 4 5 Consult factory for availability of 28V and 48V units with DC input. Output currents ratings are expressed with 300 LFM forced air. Remote sense connected. See Application Note #P1 for load regulation when using the D option for 24V units. Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. For ripple/noise on "D" option models, see options data. Models without suffix G use the lead solder exemption PARAMETER CONDITIONS / DESCRIPTION MAX UNITS Input Voltage - AC Continuous input range. MIN 85 264 VAC Input Frequency AC Input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-Up Time Over full AC input voltage range at full rated load. 20 ms Input Current 85 VAC at full rated load. Input Protection Non-user serviceable internally located AC input line fuse, F10A, 250 V. Inrush Surge Current Internally limited by thermistor, one cycle, 25C. Power Factor Per EN61000-3-2. Operating Frequency Switching frequency of main transformer. PARAMETER CONDITIONS / DESCRIPTION Efficiency Full rated load, 110 VAC. 110 VAC 220 VAC Output Power 300 LFM forced air cooling required for operation. See optional fan. Continuous power, multiple output models. Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. PFC500-1024G Without connection of remote sense. PFC500-1028G PFC500-1048G Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation. Turn-on Delay Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 35 65 APK W/VA MIN Full load, 20 MHz bandwidth. Transient Response ARMS 100 Ripple and Noise Regulation 7.8 0.98 PFC500-1024G PFC500-1028G PFC500-1048G Minimum loads NOM NOM kHz MAX UNITS 75 % 0.6 0.6 1.2 Amps See Model Selection Charts 500 Watts 0 V 0.8 0.7 1.0 % 1 ms 1 10 Sec ms tech.support@psbel.com 3 PARAMETER CONDITIONS / DESCRIPTION MIN PFC500-1024G PFC500-1028G PFC500-1048G Overvoltage Protection NOM 27.0 32.0 60.0 MAX UNITS 30.7 35.0 70.0 V Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Remote Sense Total voltage compensation for cable losses with respect to the main output. 250 mV Current Share Accuracy of shared current with up to 6 parallel units. 10 % Inhibit Input Power Fail Warning Power Good Fan Voltage TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. TTL compatible logic signal. Time before regulation dropout due to loss of input power at 110 VAC. TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal. For models without PFC500-1024G the "D" option, internal pull-up resistor is 1k> For "D" PFC500-1028G option, pull-up resistor is 475. See Apps Note #P1 for PFC500-1048G details. 4 ms 22.08 25.20 44.20 27.36 30.80 54.72 Provides 170 mA current to user supplied fan if fan option is not selected. 12 CONDITIONS / DESCRIPTION Agency Approvals Approved to the latest edition of the following standards. UL/CSA60950-1, EN60950-1 and IEC60950-1 Dielectric Withstand Meets reinforced insulation of IEC60950. Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. B B Class ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 4. 4 kV 1 2 kV Per EN61000-4-5 class 3. Insulation Resistance Input to output. Leakage Current Per EN60950, 264 VAC. Line to Line Line to Ground NOM V PARAMETER Input Transient Protection MIN V MAX UNITS Approved 10 M 2.0 mA tech.support@psbel.com 4 PARAMETER CONDITIONS / DESCRIPTION Altitude Operating. Non-Operating. Operating Temperature Derate linearly above 50C by 2.5% per C. MIN At 100% load At 50% load Storage Temperature Forced Air Cooling Forced air cooling of 300 LFM is required if the internal fan is not specified. Cooling air velocity is measured at the output exiting window (2.5" x 5"). Airflow direction is from the input section to the output section. Temperature Coefficient 0C to 70C (after 15 minute warm-up). Relative Humidity Non-Condensing. Shock Vibration PARAMETER CONDITIONS / DESCRIPTION Dimensions Overall Length With Fan Weight Isolation Diodes Fan Metric Mounting CONDITIONS / DESCRIPTION Add "D" as a suffix to the model number to order factory installed isolation diodes for parallel or redundant operation. For 24V models with the "D" option, external caps are required to meet the 1% noise/ripple spec. Power Good has a pull-up resistor of 475 on the 24V models. See Application Note #P1 for details. Add "F" as a suffix to the model number to order integral fan. Fan provides the required 300 LFM of forced air cooling, or otherwise provided by the end user. Add "M" as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. MAX UNITS 0 0 10k 40k 50 70 -55 85 C 0.05 %/C 95 %RH 0.02 5 Operating: 103mSec, 3 axis, Half Sine. Non-operating: 103mSec, 3 axis, Half Sine. Operating: 5-32 Hz 32-2000 Hz Sinusoidal Non-operating: Overall Size PARAMETER NOM MIN NOM NOM C 20 40 0.02 1 6.15 in (DA) GPK GRMS MAX UNITS 228.6 x 127.0 x 63.5 9.00 x 5.00 x 2.50 266.7 10.50 1.95 4.3 MIN ASL Ft. MAX G mm in mm in kg lb UNITS N/A 266.7 x 127.0 x 63.5 10.50 x 5.00 x 2.50 mm in N/A tech.support@psbel.com 5 NOTES: Chassis: 0.090" (2.3mm) Aluminum Alloy, With Clear Finish *Airflow should be measured at the exiting window (5" x 2.5"). Figure 1. Mechanical Drawing PFC500 NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com