Born to drive machines
MX2 INVERTER
» High programming functionality
» Built-in safety
» Omron Quality with a capital ‘Q’
3
The MX2 is specifically designed to drive
machines. It has been developed to
harmonise advanced motor and machine
control. Thanks to its advanced design and
algorithms the MX2 provides smooth control
down to zero speed, plus precise operation
for fast cyclic operations and torque control
capability in open loop. The MX2 also gives
you comprehensive functionality for machine
control such as positioning, speed
synchronisation and logic programming. The
MX2 is fully integrated within the Omron
smart automation platform. The MX2 is the
child of a true leader in machine automation.
Special motors
One parameter
auto-tuning
Torque control
in open loop
200%
starting torque
Permanent magnet motors
High speed motors up to 1000 Hz
Just by entering the kW rating of the
motor the MX2 gives you smooth
and safe operation
Ideal for low to medium torque
applications
Can replace a flux vector or servo
drive in suitable systems
Near stand-still operation (0.5 Hz)
Smooth control of high inertia loads
Control of fast cyclic loads
MOTOR CONTROL
Harmonised motor and
machine control
Positioning
Logic
programming
Safety inside
CX-Drive programming tool connected
via integrated USB port on MX2.
Modbus RS485 built-in
Option units for EtherCAT, Profibus,
DeviceNet, ML-II and more…
Conforms to safety norm ISO-13849
CAT3 performance level PL d
2 Safety inputs
External device monitoring (EDM)
MACHINE CONTROL
Up to 8 pre-set positions with
“Homing”
Speed synchronisation
Flow chart programming
Text editor
Intuitive - up to 5 tasks in parallel
Integrated in the
Omron Smart
Automation
MOTOR CONTROL
24 VDC
220 VAC
0.5 3 6 10 20 30 40 50 60
0
100
200
Hz
100% Control...
Torque master
The MX2 delivers 200% starting
torque near stand-still (0.5 Hz) and
can operate in torque control in open
loop mode. This allows the MX2 to
be used in applications where
closed loop AC vector drives were
previously used.
Easy network integration
Built-in RS485 Modbus
communications and standard
industrial networks, such as EtherCAT
(compliant with CoE - CiA402 Drive
profile -), MECHATROLINK-II,
DeviceNet, Profibus or
CompoNet as options.
External 24 VDC for
continuous operation
With no additional hardware, a 24 VDC
connection to the MX2 ensures the
CPU is always in control, even if the
main input is removed. This feature
is vital in providing a controlled stop
in emergency situations and in
keeping the network communications
operating.
High starting torque and torque control capability in
open loop mode give you full control of your machine
dynamics and performance. Options for all of the major
fieldbus systems and a 24 VDC external supply keeps
you in full control of your machine operation.
Frequency response vs Torque variation
Example with 7.5 kW 4-pole motor
Torque (%)
...0% risk!
Safety embedded;
ISO 13849-1, cat 3
Dual contactors at the output of the
inverter are no longer required.
Direct connection to a safety
controller ensures compliance to ISO
13849-1, cat 3.
EDM monitoring output
An External Device Monitoring (EDM)
output confirms the safety status of
the inverter, saving you the cost and
wiring of external devices to carry out
the same function.
Direct integration into the
safety circuit
MX2 inverters can fit easily into the
safety circuit. The safety inputs can
be linked from one inverter to
another without additional safety
relays.
Safety is embedded in the MX2, according to ISO 13849-1,
Cat 3, with two safety inputs and an External Device
Monitoring (EDM) output.
No external contactors on the motor side are required,
meaning simpler wiring for the user.
Safety redundancy input Dual safety input chain
EDM output
EDM safety output chain
Position and run!
Positioning functionality
Specially developed application functionality enables
the MX2 to solve simple positioning tasks without the
need for an external controller. Up to 8 positions, plus
home, can be selected by the user, and furthermore, the
MX2 can be switched between speed and position
mode.
Speed synchronisation
With no external hardware required, and via standard
parameter settings, speed synchronisation can be
achieved. The MX2 will act as a speed follower to an
external pulse generator/ encoder signal up to 32 KHz.
The MX2 is a drive and position controller in one, ideal
for modular machines where moderate positional
accuracy is required. Speed synchronisation is also
possible, with no additional programming required.
35
6
7
8
9
1
2
0
4
10
Program and play!
Free to program
Intuitive and user friendly flow chart programming
Integrated in CX-Drive
Up to 1000 lines in a program
5 tasks can run in parallel
The MX2 gives you the power to create smart solutions
using PLC functionality, as standard. Via an intuitive
flow chart programming tool, you can create programs
with up to 1000 lines of code and with 5 tasks running
in parallel.
Entry
End
Lbl0001
Lbl0002
Label
Label
If X(00)=1 GoTo
U(01):=20
Wait TD(0)=1
Timer Off TD (0)
False
True
Next Block
Next Block
GoTo GoTo
Timer Set TD (0) U(01)
8Frequency inverters
MX2
Born to drive machines
Current vector control
High starting torque: 200% at 0.5 Hz
Double rating VT 120%/1 min and CT 150%/1 min
IM & PM motor control
Torque control in open loop vector
Positioning functionality
Built-in application functionality (i.e. Brake control)
Built-in logic programing
Safety embedded compliant with ISO13849-1 (double input
circuit and external device monitor EDM)
USB port for PC programming
24 VDC backup supply for control board
Fieldbus communications: Modbus, DeviceNet, Profibus,
CompoNet, EtherCAT, ML-II and EtherNet/IP
PC configuration tool: CX-Drive
RoHS, CE, cULus
Ratings
200 V Class single-phase 0.1 to 2.2 kW
200 V Class three-phase 0.1 to 15.0 kW
400 V Class three-phase 0.4 to 15.0 kW
System configuration
Choke
LCD 5 lines remote
operator
Remote operator
extension cable
Output AC reactor
Communication option board
USB cable
Braking resistor
Installation accessory
CX-Drive
CX-One
MCCB
MX2
Filter
Input AC reactor
Motor
Ground
Power
supply
DC reactor
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 8 Dienstag, 4. November 2014 12:02 12
8Frequency inverters
MX2
Born to drive machines
Current vector control
High starting torque: 200% at 0.5 Hz
Double rating VT 120%/1 min and CT 150%/1 min
IM & PM motor control
Torque control in open loop vector
Positioning functionality
Built-in application functionality (i.e. Brake control)
Built-in logic programing
Safety embedded compliant with ISO13849-1 (double input
circuit and external device monitor EDM)
USB port for PC programming
24 VDC backup supply for control board
Fieldbus communications: Modbus, DeviceNet, Profibus,
CompoNet, EtherCAT, ML-II and EtherNet/IP
PC configuration tool: CX-Drive
RoHS, CE, cULus
Ratings
200 V Class single-phase 0.1 to 2.2 kW
200 V Class three-phase 0.1 to 15.0 kW
400 V Class three-phase 0.4 to 15.0 kW
System configuration
Choke
LCD 5 lines remote
operator
Remote operator
extension cable
Output AC reactor
Communication option board
USB cable
Braking resistor
Installation accessory
CX-Drive
CX-One
MCCB
MX2
Filter
Input AC reactor
Motor
Ground
Power
supply
DC reactor
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 8 Dienstag, 4. November 2014 12:02 12
MX2 9
Type designation
200 V class
400 V class
Specifications
Single-phase: 3G3MX2-@B001 B002 B004 B0071
1. Three phase model use forced-air-cooling but single phase model is self cooling.
B015 B022 - - - - -
Three-phase: 3G3MX2-@2001 2002 2004 2007 2015 2022 2037 2055 2075 2110 2150
Motor
kW2
2. Based on a standard 3-Phase standard motor.
For VT setting 0.2 0.4 0.55 1.1 2.2 3.0 5.5 7.5 11 15 18.5
For CT setting 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Output
characteristics
Inverter capacity kVA
200 VT 0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
200 CT 0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
240 VT 0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
240 CT 0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
Rated output current (A) at VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Rated output current (A) at CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
Max. output voltage Proportional to input voltage: 0..240 V
Max. output frequency 400 Hz
Power
supply
Rated input voltage
and frequency
Single-phase 200..240 V 50/60 Hz
3-phase 200..240 V 50/60 Hz
Allowable voltage fluctuation -15%..+10%
Allowable frequency fluctuation 5%
Braking torque
At short-time
deceleration
At capacitor
feedback
100%: <50Hz
50%: <60Hz
70%:
<50Hz
50%:
<60Hz
Approx 20% -
Cooling method Self cooling3
3. Forced air cooling for IP54 models.
Forced-air-cooling
Three-phase: 3G3MX2-@4004 4007 4015 4022 4030 4040 4055 4075 4110 4150
Motor
kW1
1. Based on a standard 3-Phase standard motor.
For VT setting 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
For CT setting 0.4 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15
Output
characteristics
Inverter capacity kVA
380 VT 1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
380 CT 1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
480 VT 1.7 3.4 4.4 5.7 7.3 9.2 14.5 19.1 25.7 31.5
480 CT 1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
Rated output current (A) at VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
Rated output current (A) at CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
Max. output voltage Proportional to input voltage: 0..480 V
Max. output frequency 400 Hz
Power
supply
Rated input voltage
and frequency 3-phase 380..480 V 50/60 Hz
Allowable voltage
fluctuation -15%..+10%
Allowable frequency
fluctuation 5%
Braking torque
At short-time
deceleration
At capacitor
feedback
100%: <50Hz
50%: <60Hz
70%:
<50Hz
50%:
<60Hz
-
Cooling method Self cooling2
2. Forced air cooling for IP54 models.
Forced-air-cooling
MX2 series
3G3MX2-AB002-@-E@
A: IP20
D: IP54 (Includes Class 2 EMC lter)
Voltage:
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
Max. applicable motor output
002: 0,2 kW
~
150: 15,0 kW
P: Finless
C: IP54 ready for customization
E: Europe standard
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 9 Dienstag, 4. November 2014 12:02 12
10 Frequency inverters
Common specifications
Specifications
Model number
3G3MX2 Specifications
Control functions
Control methods Phase-to-phase sinusoidal pulse with modulation PWM (Sensorless vector control, V/F)
Output frequency range 0.10..400.00 Hz
Frequency precision Digital set value: ±0.01% of the max. frequency
Analogue set value: ±0.2% of the max. frequency (25 ±10ºC)
Resolution of frequency set value Digital set value: 0.01 Hz
Analogue set value: 1/1000 of maximum frequency
Resolution of output frequency 0.01Hz
Starting torque 200% / 0.5 Hz
Overload capability
Dual rating:
Heavy duty (CT): 150% for 1 minute
Normal Duty (VT): 120% for 1 minute
Frequency set value 0 to 10 VDC (10 K), 4 to 20 mA (100 ), RS485 Modbus, Network options
V/f Characteristics Constant/ reduced torque, free V/f
Functionality
Inputs signals
FW (forward run command), RV (reverse run command), CF1~CF4 (multi-stage speed setting), JG (jog command), DB (ex-
ternal braking), SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external
trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), AT (analog input selection), RS (reset), PTC
(thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (re-
mote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control),
SF1~SF7 (multi-stage speed setting; bit operation), OLR (overload restriction), TL (torque limit enable), TRQ1 (torque limit
changeover1), TRQ2 (torque limit changeover2), BOK (Braking confirmation), LAC (LAD cancellation), PCLR (position devi-
ation clear), ADD (add frequency enable), F-TM (force terminal mode), ATR (permission of torque command input), KHC (Cu-
mulative power clear), MI1~MI7 (general purpose inputs for Drive Programming), AHD (analog command hold), CP1~CP3
(multistage-position switches), ORL (limit signal of zero-return), ORC (trigger signal of zero-return), SPD (speed/position
changeover), GS1~GS2 (STO inputs, safety related signals), 485 (Starting communication signal), PRG (executing Drive
Programming), HLD (retain output frequency), ROK (permission of run command), EB (rotation direction detection of B-
phase), DISP (display limitation), OP (option control signal), NO (no function), PSET (preset position)
Output signals
RUN (run signal), FA1~FA5 (frequency arrival signal), OL,OL2 (overload advance notice signal), OD (PID deviation error sig-
nal), AL (alarm signal), OTQ (over/under torque threshold), UV (under-voltage), TRQ (torque limit signal), RNT (run time ex-
pired), ONT (power ON time expired), THM (thermal warning), BRK (brake release), BER (brake error), ZS (0Hz detection),
DSE (speed deviation excessive), POK (positioning completion), ODc (analog voltage input disconnection), OIDc (analog
current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), LOG1~LOG3 (Logic out-
put signals), WAC (capacitor life warning), WAF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warn-
ing), LOC (Low load), MO1~MO3 (general outputs for Drive Programming), IRDY (inverter ready), FWR (forward operation),
RVR (reverse operation), MJA (major failure), WCO (window comparator O), WCOI (window comparator OI), FREF (frequen-
cy command source), REF (run command source), SETM (second motor in operation), EDM (STO (safe torque off) perfor-
mance monitor), OP (option control signal), NO (no function)
Standard functions
Free-V/f, manual/automatic torque boost, output voltage gain adjustment, AVR function, reduced voltage start, motor data
selection, auto-tuning, motor stabilization control, reverse running protection, simple position control, simple torque control,
torque limiting, automatic carrier frequency reduction, energy saving operation, PID function, non-stop operation at
instantaneous power failure, brake control, DC injection braking, dynamic braking (BRD), frequency upper and lower
limiters, jump frequencies, curve accel and decel (S, U, inversed U,EL-S), 16-stage speed profile, fine adjustment of start
frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2-stage accel/decel, stop mode
selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/hold
function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display
restriction, password function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry,
frequency pull-in restart, frequency matching, overload restriction, over current restriction, DC bus voltage AVR
Analogue inputs 2 analogue inputs 0 to 10 V (10 K), 4 to 20 mA (100 )
Pulse train input terminal 0 to 24 V, up to 32 kHz
Accel/Decel times 0.01 to 3600.0 s (line/curve selection), 2nd accel/decel setting available
Display Status indicator LED’s Run, Program, Alarm, Power, Hz, Amps
Digital operator: Available to monitor 32 items: frequency reference, output current, output frequency...
Protection functions
Motor overload protection Electronic Thermal overload relay and PTC thermistor input
Instantaneous overcurrent 200% of rated current
Overload
Dual rating:
Heavy duty (CT): 150% for 1 minute
Normal Duty (VT): 120% for 1 minute
Overvoltage 800 V for 400 V type and 400 V for 200 V type
Undervoltage 345 V for 400 V type and 172.5 V for 200 V type
Momentary power loss Following items are selectable: Alarm, decelerates to stop, decelerates to stop with DC bus controlled, restart
Cooling fin overheat Temperature monitor and error detection
Stall prevention level Stall prevention during acceleration/deceleration and constant speed
Ground fault Detection at power-on
Power charge indication On when power is supplied to the control part
Ambient conditions
Degree of protection IP20, Varnish coating on PCB & IP54 (For 3G3MX2-D@ type)
Ambient humidity 90% RH or less (without condensation)
Storage temperature -20ºC..+65ºC (short-term temperature during transportation)
Ambient temperature1
1. Some types of 3G3MX2-D requires special derating depending on installation conditions and carrier frequency selected. Check the manual for details.
10C to 50ºC (Both the carrier frequency and output current need to be reduced over 40ºC)
Installation Indoor (no corrosive gas, dust, etc.)
Installation height Max. 1000 m
Vibration 5.9 m/s2 (0.6G), 10 to 55 Hz
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 10 Dienstag, 4. November 2014 12:02 12
10 Frequency inverters
Common specifications
Specifications
Model number
3G3MX2 Specifications
Control functions
Control methods Phase-to-phase sinusoidal pulse with modulation PWM (Sensorless vector control, V/F)
Output frequency range 0.10..400.00 Hz
Frequency precision Digital set value: ±0.01% of the max. frequency
Analogue set value: ±0.2% of the max. frequency (25 ±10ºC)
Resolution of frequency set value Digital set value: 0.01 Hz
Analogue set value: 1/1000 of maximum frequency
Resolution of output frequency 0.01Hz
Starting torque 200% / 0.5 Hz
Overload capability
Dual rating:
Heavy duty (CT): 150% for 1 minute
Normal Duty (VT): 120% for 1 minute
Frequency set value 0 to 10 VDC (10 K), 4 to 20 mA (100 ), RS485 Modbus, Network options
V/f Characteristics Constant/ reduced torque, free V/f
Functionality
Inputs signals
FW (forward run command), RV (reverse run command), CF1~CF4 (multi-stage speed setting), JG (jog command), DB (ex-
ternal braking), SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external
trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), AT (analog input selection), RS (reset), PTC
(thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (re-
mote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control),
SF1~SF7 (multi-stage speed setting; bit operation), OLR (overload restriction), TL (torque limit enable), TRQ1 (torque limit
changeover1), TRQ2 (torque limit changeover2), BOK (Braking confirmation), LAC (LAD cancellation), PCLR (position devi-
ation clear), ADD (add frequency enable), F-TM (force terminal mode), ATR (permission of torque command input), KHC (Cu-
mulative power clear), MI1~MI7 (general purpose inputs for Drive Programming), AHD (analog command hold), CP1~CP3
(multistage-position switches), ORL (limit signal of zero-return), ORC (trigger signal of zero-return), SPD (speed/position
changeover), GS1~GS2 (STO inputs, safety related signals), 485 (Starting communication signal), PRG (executing Drive
Programming), HLD (retain output frequency), ROK (permission of run command), EB (rotation direction detection of B-
phase), DISP (display limitation), OP (option control signal), NO (no function), PSET (preset position)
Output signals
RUN (run signal), FA1~FA5 (frequency arrival signal), OL,OL2 (overload advance notice signal), OD (PID deviation error sig-
nal), AL (alarm signal), OTQ (over/under torque threshold), UV (under-voltage), TRQ (torque limit signal), RNT (run time ex-
pired), ONT (power ON time expired), THM (thermal warning), BRK (brake release), BER (brake error), ZS (0Hz detection),
DSE (speed deviation excessive), POK (positioning completion), ODc (analog voltage input disconnection), OIDc (analog
current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), LOG1~LOG3 (Logic out-
put signals), WAC (capacitor life warning), WAF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warn-
ing), LOC (Low load), MO1~MO3 (general outputs for Drive Programming), IRDY (inverter ready), FWR (forward operation),
RVR (reverse operation), MJA (major failure), WCO (window comparator O), WCOI (window comparator OI), FREF (frequen-
cy command source), REF (run command source), SETM (second motor in operation), EDM (STO (safe torque off) perfor-
mance monitor), OP (option control signal), NO (no function)
Standard functions
Free-V/f, manual/automatic torque boost, output voltage gain adjustment, AVR function, reduced voltage start, motor data
selection, auto-tuning, motor stabilization control, reverse running protection, simple position control, simple torque control,
torque limiting, automatic carrier frequency reduction, energy saving operation, PID function, non-stop operation at
instantaneous power failure, brake control, DC injection braking, dynamic braking (BRD), frequency upper and lower
limiters, jump frequencies, curve accel and decel (S, U, inversed U,EL-S), 16-stage speed profile, fine adjustment of start
frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2-stage accel/decel, stop mode
selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/hold
function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display
restriction, password function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry,
frequency pull-in restart, frequency matching, overload restriction, over current restriction, DC bus voltage AVR
Analogue inputs 2 analogue inputs 0 to 10 V (10 K), 4 to 20 mA (100 )
Pulse train input terminal 0 to 24 V, up to 32 kHz
Accel/Decel times 0.01 to 3600.0 s (line/curve selection), 2nd accel/decel setting available
Display Status indicator LED’s Run, Program, Alarm, Power, Hz, Amps
Digital operator: Available to monitor 32 items: frequency reference, output current, output frequency...
Protection functions
Motor overload protection Electronic Thermal overload relay and PTC thermistor input
Instantaneous overcurrent 200% of rated current
Overload
Dual rating:
Heavy duty (CT): 150% for 1 minute
Normal Duty (VT): 120% for 1 minute
Overvoltage 800 V for 400 V type and 400 V for 200 V type
Undervoltage 345 V for 400 V type and 172.5 V for 200 V type
Momentary power loss Following items are selectable: Alarm, decelerates to stop, decelerates to stop with DC bus controlled, restart
Cooling fin overheat Temperature monitor and error detection
Stall prevention level Stall prevention during acceleration/deceleration and constant speed
Ground fault Detection at power-on
Power charge indication On when power is supplied to the control part
Ambient conditions
Degree of protection IP20, Varnish coating on PCB & IP54 (For 3G3MX2-D@ type)
Ambient humidity 90% RH or less (without condensation)
Storage temperature -20ºC..+65ºC (short-term temperature during transportation)
Ambient temperature1
1. Some types of 3G3MX2-D requires special derating depending on installation conditions and carrier frequency selected. Check the manual for details.
10C to 50ºC (Both the carrier frequency and output current need to be reduced over 40ºC)
Installation Indoor (no corrosive gas, dust, etc.)
Installation height Max. 1000 m
Vibration 5.9 m/s2 (0.6G), 10 to 55 Hz
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 10 Dienstag, 4. November 2014 12:02 12
MX2 11
Standard models (IP20)
Option board
Note: Option boards could be fitted inside the IP54 model.
Dimensions
Voltage class Inverter model
3G3MX2-A@Figure Dimensions in mm
WW1 HH1 t D D1 D2 dWeight (kg)
Single-phase
200 V
B001-E
1 68 56 128 118
-
109 13.5 --
1.0
B002-E 1.0
B004-E 122.5 27 1.1
B007-E
2 108 96 128 118 170.5 55 4.4 4.5
1.4
B015-E 1.8
B022-E 1.8
Three-phase
200 V
2001-E
1 68 56 128 118
-
109 13.5
--
1.0
2002-E 1.0
2004-E 122.5 27 1.1
2007-E 145.5 50 1.2
2015-E 2 108 96 128 118 170.5 55 4.4 4.5
1.6
2022-E 1.8
2037-E
3
140 128 128 118 5 170.5 55 4.4 2.0
2055-E 140 122 260 248 6 155 73.3 6 6 3.0
2075-E 3.4
2110-E 180 160 296 284 7 175 97 57 5.1
2150-E 220 192 350 336 84 7.4
Three-phase
400 V
4004-E
2 108 96 128 118 -
143.5 28
--
1.5
4007-E
170.5 55
1.6
4015-E 1.8
4022-E 1.9
4030-E 1.9
4040-E
3
140
128 128 118 5 170.5 55 4.4 4.5 2.1
4055-E 122 260 248 6 155 73.3 6 6 3.5
4075-E 3.5
4110-E 180 160 296 284 7 175 97 5 7 4.7
4150-E 5.2
‚o‚v‚q
‚`‚k‚l
‚q‚t‚m
‚g‚š
‚` ‚o‚q‚f
‚q‚t‚m
‚r‚s‚n‚o
‚q‚d‚r‚d‚s
‚R‚f‚R‚l‚w‚Q
?@
‚h‚m‚u‚d‚q‚s‚d‚q
H
H1
W1
W2-d
t
D2
D1
D
Figure 3
‚o‚v‚q
‚`‚k‚l
‚q‚t‚m
‚g‚š
‚` ‚o‚q‚f
‚q‚t‚m
‚r‚s‚n‚o
‚q‚d‚r‚d‚s
‚R‚fR‚l‚w‚Q
?@
‚h‚m‚u‚d‚q‚s‚d‚q
HH1
W1
W
5
2,6
D1
D
4.5
Figure 1
‚o‚v‚q
‚`‚k‚l
‚q‚t‚m
‚g‚š
‚` ‚o‚q‚f
‚q‚t‚m
‚r‚s‚n‚o
‚q‚d‚r‚d‚s
‚R‚f‚R‚l‚w‚Q
?@
‚h‚m‚u‚d‚q‚s‚d‚q
H
W1
W
t
2-d
D1
D
D2
H1
Figure 2
67.6
27.9
53.1
28.6
60.0
44.9
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 11 Dienstag, 4. November 2014 12:02 12
12 Frequency inverters
Finless models
Voltage class Inverter model
3G3MX2-A@Figure Dimensions in mm
WW1 HH1 DD1 Weight (kg)
Single-phase
200 V
B001-P-E
1 68 56 128 118 103 7.5 1.1B002-P-E
B004-P-E
B007-P-E
2 108 96 128 118 123 7.5 1.8B015-P-E
B022-P-E
Three-phase
200 V
2001-P-E
1 68 56 128 118 103 7.5 1.1
2002-P-E
2004-P-E
2007-P-E
2015-P-E 2 108 96 128 118 123 7.5 1.8
2022-P-E
2037-P-E 3 140 128 128 118 123 7.5 2.1
Three-phase
400 V
4004-P-E
2 108 96 128 118 123 7.5 1.8
4007-P-E
4015-P-E
4022-P-E
4030-P-E
4040-P-E 3 140 128 128 118 123 7.5 2.1
8.8.8.8.
W
Ø
4.5
W1
H
H1
5
D
D1
Figure 3
8.8.8.8.
W
W1
H
H1
5
D
D1
Ø
4.5
Figure 2
8.8.8.8.
W
W1
Ø
4.5
H
H1
5
D
D1
Figure 1
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 12 Dienstag, 4. November 2014 12:02 12
12 Frequency inverters
Finless models
Voltage class Inverter model
3G3MX2-A@Figure Dimensions in mm
WW1 HH1 DD1 Weight (kg)
Single-phase
200 V
B001-P-E
1 68 56 128 118 103 7.5 1.1B002-P-E
B004-P-E
B007-P-E
2 108 96 128 118 123 7.5 1.8B015-P-E
B022-P-E
Three-phase
200 V
2001-P-E
1 68 56 128 118 103 7.5 1.1
2002-P-E
2004-P-E
2007-P-E
2015-P-E 2 108 96 128 118 123 7.5 1.8
2022-P-E
2037-P-E 3 140 128 128 118 123 7.5 2.1
Three-phase
400 V
4004-P-E
2 108 96 128 118 123 7.5 1.8
4007-P-E
4015-P-E
4022-P-E
4030-P-E
4040-P-E 3 140 128 128 118 123 7.5 2.1
8.8.8.8.
W
Ø
4.5
W1
H
H1
5
D
D1
Figure 3
8.8.8.8.
W
W1
H
H1
5
D
D1
Ø
4.5
Figure 2
8.8.8.8.
W
W1
Ø
4.5
H
H1
5
D
D1
Figure 1
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 12 Dienstag, 4. November 2014 12:02 12
MX2 13
IP54 models
Figure 1 Figure 2 Figure 3 Figure 4
3G3MX2-DB001-E 3G3MX2-DB001-EC 3G3MX2-D2055-EC 3G3MX2-D2110-EC
3G3MX2-DB002-E 3G3MX2-DB002-EC 3G3MX2-D2075-EC 3G3MX2-D2150-EC
3G3MX2-DB004-E 3G3MX2-DB004-EC 3G3MX2-D4055-EC 3G3MX2-D4110-EC
3G3MX2-D2001-E 3G3MX2-DB007-EC 3G3MX2-D4075-EC 3G3MX2-D4150-EC
3G3MX2-D2002-E 3G3MX2-DB015-EC
3G3MX2-D2004-E 3G3MX2-DB022-EC
3G3MX2-D2007-E 3G3MX2-D2001-EC
3G3MX2-D2002-EC
3G3MX2-D2004-EC
3G3MX2-D2007-EC
3G3MX2-D2015-EC
3G3MX2-D2022-EC
3G3MX2-D2037-EC
3G3MX2-D4004-EC
3G3MX2-D4007-EC
3G3MX2-D4015-EC
3G3MX2-D4022-EC
3G3MX2-D4030-EC
3G3MX2-D4040-EC
464.74
179.5
274
292.7
150
444
12.5
62.44
169.5
Figure 1
309.5
482.8
462.33
279.5
12.5
298.9
317.7
63.5
299.5
Figure 2
299.5
281
325
607
627.04
12.5
295
315
63
Figure 3
379
710.35
311
349
369
689.85
329.7
18.7
Figure 4
11.5
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 13 Dienstag, 4. November 2014 12:02 12
14 Frequency inverters
Rasmi footprint filters
Schaffner footprint filters
Input AC Reactor
Single-phase
Three-phase
Rasmi model Dimensions
W H L X Y M
1x200 V
AX-FIM1010-RE@71 45 169 156 51 M4
AX-FIM1014-RE@111 50 169 156 91 M4
AX-FIM1024-RE@111 50 169 156 91 M4
3x200 V
AX-FIM2010-RE@82 50 194 181 62 M4
AX-FIM2020-RE@111 50 169 156 91 M4
AX-FIM2030-RE@144 50 174 161 120 M4
AX-FIM2060-RE@150 52 320 290 122 M5
AX-FIM2080-RE@188 62 362 330 160 M5
AX-FIM2100-RE@220 62 415 380 192 M6
3x400 V
AX-FIM3005-RE@114 46 169 156 96 M4
AX-FIM3010-RE@114 46 169 156 96 M4
AX-FIM3014-RE@144 50 174 161 120 M4
AX-FIM3030-RE@150 52 306 290 122 M5
AX-FIM3050-RE@182 62 357 330 160 M5
Schaffner model Dimensions
W H L X Y A B M
1x200 V
AX-FIM1010-SE@70 40 166 156 51 150 50 M5
AX-FIM1014-SE@110 45 166 156 91 150 80 M5
AX-FIM1024-SE@110 50 166 156 91 150 80 M5
3x200 V
AX-FIM2010-SE@80 40 191 181 62 150 50 M5
AX-FIM2020-SE@110 50 166 156 91 150 80 M5
AX-FIM2030-SE@142 50 171 161 120 150 112 M5
AX-FIM2060-SE@140 55 304 290 122 286 112 M5
AX-FIM2080-SE@180 55 344 330 160 323 140 M5
AX-FIM2100-SE@220 65 394 380 192 376 180 M5
3x400 V
AX-FIM3005-SE@110 50 166 156 91 150 80 M5
AX-FIM3010-SE@110 50 166 156 91 150 80 M5
AX-FIM3014-SE@142 50 171 161 120 150 112 M5
AX-FIM3030-SE@140 55 304 290 122 286 112 M5
AX-FIM3050-SE@180 55 344 330 160 323 140 M5
Voltage Reference Dimensions Weight
kg
A B C D E F G H
200 V
AX-RAI02000070-DE 84 113 96 101 66 5 7.5 2 1.22
AX-RAI01700140-DE 84 113 116 101 66 5 7.5 2 1.95
AX-RAI01200200-DE 84 113 131 101 66 5 7.5 2 2.55
AX-RAI00630240-DE 84 113 116 101 66 5 7.5 2 1.95
Voltage Reference Dimensions Weight
kg
AB2 C2 D E F
200 V
AX-RAI02800080-DE 120 70 120 80 52 5.5 1.78
AX-RAI00880200-DE 120 80 120 80 62 5.5 2.35
AX-RAI00350335-DE 180 85 190 140 55 6 5.5
AX-RAI00180670-DE 180 85 190 140 55 6 5.5
400 V
AX-RAI07700050-DE 120 70 120 80 52 5.5 1.78
AX-RAI03500100-DE 120 80 120 80 62 5.5 2.35
AX-RAI01300170-DE 120 80 120 80 62 5.5 2.50
AX-RAI00740335-DE 180 85 190 140 55 6 5.5
L1 N
N'
L1'
AX-FIM1024-SE-V1
LO AD
LINE
X
A
Y
B
L
HW
drive mounts
W
H
Y
XL
output
flexes
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 14 Dienstag, 4. November 2014 12:02 12
14 Frequency inverters
Rasmi footprint filters
Schaffner footprint filters
Input AC Reactor
Single-phase
Three-phase
Rasmi model Dimensions
W H L X Y M
1x200 V
AX-FIM1010-RE@71 45 169 156 51 M4
AX-FIM1014-RE@111 50 169 156 91 M4
AX-FIM1024-RE@111 50 169 156 91 M4
3x200 V
AX-FIM2010-RE@82 50 194 181 62 M4
AX-FIM2020-RE@111 50 169 156 91 M4
AX-FIM2030-RE@144 50 174 161 120 M4
AX-FIM2060-RE@150 52 320 290 122 M5
AX-FIM2080-RE@188 62 362 330 160 M5
AX-FIM2100-RE@220 62 415 380 192 M6
3x400 V
AX-FIM3005-RE@114 46 169 156 96 M4
AX-FIM3010-RE@114 46 169 156 96 M4
AX-FIM3014-RE@144 50 174 161 120 M4
AX-FIM3030-RE@150 52 306 290 122 M5
AX-FIM3050-RE@182 62 357 330 160 M5
Schaffner model Dimensions
W H L X Y A B M
1x200 V
AX-FIM1010-SE@70 40 166 156 51 150 50 M5
AX-FIM1014-SE@110 45 166 156 91 150 80 M5
AX-FIM1024-SE@110 50 166 156 91 150 80 M5
3x200 V
AX-FIM2010-SE@80 40 191 181 62 150 50 M5
AX-FIM2020-SE@110 50 166 156 91 150 80 M5
AX-FIM2030-SE@142 50 171 161 120 150 112 M5
AX-FIM2060-SE@140 55 304 290 122 286 112 M5
AX-FIM2080-SE@180 55 344 330 160 323 140 M5
AX-FIM2100-SE@220 65 394 380 192 376 180 M5
3x400 V
AX-FIM3005-SE@110 50 166 156 91 150 80 M5
AX-FIM3010-SE@110 50 166 156 91 150 80 M5
AX-FIM3014-SE@142 50 171 161 120 150 112 M5
AX-FIM3030-SE@140 55 304 290 122 286 112 M5
AX-FIM3050-SE@180 55 344 330 160 323 140 M5
Voltage Reference Dimensions Weight
kg
A B C D E F G H
200 V
AX-RAI02000070-DE 84 113 96 101 66 5 7.5 2 1.22
AX-RAI01700140-DE 84 113 116 101 66 5 7.5 2 1.95
AX-RAI01200200-DE 84 113 131 101 66 5 7.5 2 2.55
AX-RAI00630240-DE 84 113 116 101 66 5 7.5 2 1.95
Voltage Reference Dimensions Weight
kg
AB2 C2 D E F
200 V
AX-RAI02800080-DE 120 70 120 80 52 5.5 1.78
AX-RAI00880200-DE 120 80 120 80 62 5.5 2.35
AX-RAI00350335-DE 180 85 190 140 55 6 5.5
AX-RAI00180670-DE 180 85 190 140 55 6 5.5
400 V
AX-RAI07700050-DE 120 70 120 80 52 5.5 1.78
AX-RAI03500100-DE 120 80 120 80 62 5.5 2.35
AX-RAI01300170-DE 120 80 120 80 62 5.5 2.50
AX-RAI00740335-DE 180 85 190 140 55 6 5.5
L1 N
N'
L1'
AX-FIM1024-SE-V1
LO AD
LINE
X
A
Y
B
L
H W
drive mounts
W
H
Y
XL
output
flexes
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 14 Dienstag, 4. November 2014 12:02 12
MX2 15
DC Reactor
Output AC Reactor
Chokes
Voltage Reference Dimensions Weight
kg
A B C D E F G H
200 V
AX-RC21400016-DE
84 113
96
101 66 5 7.5 2
1.22
AX-RC10700032-DE
AX-RC06750061-DE 105 1.60
AX-RC03510093-DE
AX-RC02510138-DE 116 1.95
AX-RC01600223-DE 108 135 124 120 82 6.5
9.5
9.5 3.20
AX-RC01110309-DE 120 152 136 135 94
7-
5.20
AX-RC00840437-DE 146 6.00
AX-RC00590614-DE 150 177 160 160 115 2 11.4
AX-RC00440859-DE 182.6 14.3
400 V
AX-RC43000020-DE
84 113
96
101 66 5 7.5 2
1.22
AX-RC27000030-DE 105 1.60
AX-RC14000047-DE
AX-RC10100069-DE 116 1.95
AX-RC08250093-DE 131 2.65
AX-RC06400116-DE 108 135 133 120 82 6.5
9.5
9.5 3.70
AX-RC04410167-DE 120 152 136 135 94 7
-
5.20
AX-RC03350219-DE 146 6.00
AX-RC02330307-DE 150 177 160 160 115 7 2 11.4
AX-RC01750430-DE 182.6 14.3
Voltage Reference Dimensions Weight
kg
AB2 C2 D E F
200 V
AX-RAO11500026-DE 120 70 120 80 52 5.5 1.78
AX-RAO07600042-DE 120 70 120 80 52 5.5 1.78
AX-RAO04100075-DE 120 80 120 80 62 5.5 2.35
AX-RAO03000105-DE 120 80 120 80 62 5.5 2.35
AX-RAO01830180-DE 180 85 190 140 55 6 5.5
AX-RAO01150220-DE 180 85 190 140 55 6 5.5
AX-RAO00950320-DE 180 85 205 140 55 6 6.5
AX-RAO00630430-DE 180 95 205 140 65 6 9.1
AX-RAO00490640-DE 180 95 205 140 65 6 9.1
400 V
AX-RAO16300038-DE 120 70 120 80 52 5.5 1.78
AX-RAO11800053-DE 120 80 120 80 52 5.5 2.35
AX-RAO07300080-DE 120 80 120 80 62 5.5 2.35
AX-RAO04600110-DE 180 85 190 140 55 6 5.5
AX-RAO03600160-DE 180 85 205 140 55 6 6.5
AX-RAO02500220-DE 180 95 205 140 55 6 9.1
AX-RAO02000320-DE 180 105 205 140 85 6 11.7
Reference D
diameter
Motor
kW
Dimensions Weight
kg
L W H X Y m
AX-FER2102-RE 21 < 2.2 85 22 46 70 - 5 0.1
AX-FER2515-RE 25 < 15 105 25 62 90 - 5 0.2
AX-FER5045-RE 50 < 45 150 50 110 125 30 5 0.7
X
H
YW
Ø
m
L
Ø
d
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 15 Dienstag, 4. November 2014 12:02 12
16 Frequency inverters
Resistor dimensions
Type Fig. Dimensions Weight
L H M I T G N kg
AX-REM00K1400-IE
1
105 27 36 94 - - - 0.2
AX-REM00K2070-IE
AX-REM00K2120-IE
AX-REM00K2200-IE
AX-REM00K4075-IE
200 27 36 189 - - - 0.425AX-REM00K4035-IE
AX-REM00K4030-IE
AX-REM00K5120-IE 260 27 36 249 - - - 0.58
AX-REM00K6100-IE 320 27 36 309 - - - 0.73
AX-REM00K6035-IE
AX-REM00K9070-IE
2 200 61 100 74 211 40 230 1.41AX-REM00K9020-IE
AX-REM00K9017-IE
AX-REM01K9070-IE 3 365 73 105 350 70 - - 4
AX-REM01K9017-IE
AX-REM02K1070-IE
4
310 100 240 295 210 - - 7
AX-REM02K1017-IE
AX-REM03K5035-IE 365 100 240 350 210 - - 8
AX-REM03K5010-IE
AX-REM00K1xxx
Fig 1
Fig 3
Fig 4
Fig 2
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 16 Dienstag, 4. November 2014 12:02 12
16 Frequency inverters
Resistor dimensions
Type Fig. Dimensions Weight
L H M I T G N kg
AX-REM00K1400-IE
1
105 27 36 94 - - - 0.2
AX-REM00K2070-IE
AX-REM00K2120-IE
AX-REM00K2200-IE
AX-REM00K4075-IE
200 27 36 189 - - - 0.425AX-REM00K4035-IE
AX-REM00K4030-IE
AX-REM00K5120-IE 260 27 36 249 - - - 0.58
AX-REM00K6100-IE 320 27 36 309 - - - 0.73
AX-REM00K6035-IE
AX-REM00K9070-IE
2 200 61 100 74 211 40 230 1.41AX-REM00K9020-IE
AX-REM00K9017-IE
AX-REM01K9070-IE 3 365 73 105 350 70 - - 4
AX-REM01K9017-IE
AX-REM02K1070-IE
4
310 100 240 295 210 - - 7
AX-REM02K1017-IE
AX-REM03K5035-IE 365 100 240 350 210 - - 8
AX-REM03K5010-IE
AX-REM00K1xxx
Fig 1
Fig 3
Fig 2
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 16 Dienstag, 4. November 2014 12:02 12
MX2 17
Standard connections
Terminal Block Specifications
Terminal Name Function (signal level)
R/L1, S/L2, T/L3
Main circuit power supply input Used to connect line power to the drive.
Drives with single-phase 200 V input power use only terminals R/L1 and N (T/L3), terminal
S/L2 is not available for these units
U/T1, V/T2, W/T3 Inverter output Used to connect the motor
PD/+1, P/+ External DC reactor terminal Normally connected by the short-circuit bar. Remove the short-circuit bar between +1 and P/
+2 when a DC reactor is connected.
P/+, N/- Regenerative braking unit terminal Connect optional regenerative braking units (If a braking torque is required)
P/+, RB Braking resistor terminals Connect option braking resistor (if a braking torque is required)
Grounding For grounding (grounding should conform to the local grounding code.)
Input
circuits
24V
P 24 + -
1
2
3/GS1
4/GS2
5/PTC
Forward
Thermistor
GND for logic inputs
AM
Meter
H
L
Analog reference
0~10VDC
4~20mA
GND for analog signals
MX2
Motor
PD/+1
P/+
R
(L1)
S
(L2)
T
N(L3)
U
(T1)
V
(T2)
W
(T3)
N/-
AL2
A L 0
A L 1
6
7/EB
EO
Meter
RB
11/EDM
Load
Freq. arrival signal
Open collector output
Output circuit
GND for logic outputs
12 Load
+
-
CM2
L
L
+
-
O
OI
EA
Apprx.10k
10Vdc
Apprx.100
L
L
Option port connector
L
L
L
L
L
L
SP
SN
)
L
PLC
Short bar
(Source type)
Breaker, MCCB
or GFI
Power source,
3-phase or
1-phase, per
inverter model
Intelligent inputs,
7 terminals
NOTE: For the wiring
of intelligent I/O and
analog inputs, be sure
to use twisted pair/
shielded cable. Attach
the shielded wire for
each signal to its
respective common
terminal at the inverter
end only.
Input impedance of
each intelligent input is
4.7k
[5] configurable as
discrete input or
thermistor input
Pulse train input
24Vdc 32kHz max.
RS485
transceiver
USB
transceiver
Option port
controller
USB (mini-B) port
(PC communication port)
USB power: Self power
RJ45 port
(Optional operator port)
RS485
transceiver
Serial communication port
(RS485/ModBus)
Termination resistor (200
(Change by slide switch)
Relay contacts,
type 1 Form C
Brake
resistor
(optional)
Braking
unit
(optional)
DC reactor
(optional)
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 17 Dienstag, 4. November 2014 12:02 12
18 Frequency inverters
Control Circuit
Side by side mounting
Inverter heat loss
Single-phase 200 V class
Type No. Signal name Function Signal level
Digital input signals
PLC Intelligent input common Source type: connecting [P24] to [1]-[7] turns inputs ON
Sink type: connecting [L] to [1]-[7] turns inputs ON -
P24 Internal 24 VDC 24 VDC, 30mA 24 VDC, 100 mA
1Multi-function Input selection 1 Factory setting: Forward/ Stop
27 VDC max
2Multi-function Input selection 2 Factory setting: Reverse/ Stop
3/GS1 Multi-function Input selection 3 / safe stop input 1 Factory setting: External trip
4/GS2 Multi-function Input selection 4 / safe stop input 2 Factory setting: Reset
5/PTC Multi-function Input selection 5 / PTC thermistor input Factory setting: Multi-step speed reference 1
6Multi-function input selection 6 Factory setting: Multi-step speed reference 2
7/EB Multi-function input selection 7 / Pulse train input B Factory setting: Jog
LMulti-function Input selection common (in upper row) -- --
Pulse
train
EA Pulse train input A Factory setting: Speed reference 32 kHz max
5 to 24 VDC
EO Pulse train output LAD frequency 10 VDC 2 mA
32 kHz max
Analog input
signal
HFrequency reference power supply 10 VDC 10 mA max
OVoltage frequency reference signal 0 to 10 VDC (10 k)
OI Current frequency reference signal 4 to 20 mA (250 )
LFrequency reference common (bottom row) --
Digital output
signals
11/EDM Discrete logic output 1 / EDM output Factory setting: During Run
27 VDC, 50 mA max
EDM based on
ISO13849-1
12 Discrete logic output 2 Factory setting: Frequency arrival type 1
CM2 GND logic output --
AL0 Relay common contact Factory setting: Alarm signal
Under normal operation
AL1 - AL0 Closed
AL2 - AL0 Open
R load
250 VAC 2.5 A
30 VDC 3.0 A
I load
250 VAC 0.2 A
30 VDC 0.7 A
AL1 Relay contact, normally open
AL2 Relay contact, normally closed
Monitor
Signal
AM Analog voltage output Factory setting: LAD frequency 0 to 10 VDC 1 mA
Comms
SP
Serial communication terminal RS485 Modbus communication
SN
Model 3G3MX2 AB001 AB002 AB004 AB007 AB015 AB022
Inverter
capacity
kVA
200V VT 0.4 0.6 1.2 2.0 3.3 4.1
200V CT 0.2 0.5 1.0 1.7 2.7 3.8
240V VT 0.4 0.7 1.4 2.4 3.9 4.9
240V CT 0.3 0.6 1.2 2.0 3.3 4.5
Rated current (A) VT 1.2 1.9 3.4 6.0 9.6 12.0
Rated current (A) CT 1.0 1.6 3.0 5.0 8.0 11.0
Total heat loss 12 22 30 48 79 104
Efficiency at rated load 89.5 90 93 94 95 95.5
Cooling Method Self cooling Forced-air-cooling
Enclosure 100mm
100mm
50mm
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 18 Dienstag, 4. November 2014 12:02 12
18 Frequency inverters
Control Circuit
Side by side mounting
Inverter heat loss
Single-phase 200 V class
Type No. Signal name Function Signal level
Digital input signals
PLC Intelligent input common Source type: connecting [P24] to [1]-[7] turns inputs ON
Sink type: connecting [L] to [1]-[7] turns inputs ON -
P24 Internal 24 VDC 24 VDC, 30mA 24 VDC, 100 mA
1Multi-function Input selection 1 Factory setting: Forward/ Stop
27 VDC max
2Multi-function Input selection 2 Factory setting: Reverse/ Stop
3/GS1 Multi-function Input selection 3 / safe stop input 1 Factory setting: External trip
4/GS2 Multi-function Input selection 4 / safe stop input 2 Factory setting: Reset
5/PTC Multi-function Input selection 5 / PTC thermistor input Factory setting: Multi-step speed reference 1
6Multi-function input selection 6 Factory setting: Multi-step speed reference 2
7/EB Multi-function input selection 7 / Pulse train input B Factory setting: Jog
LMulti-function Input selection common (in upper row) -- --
Pulse
train
EA Pulse train input A Factory setting: Speed reference 32 kHz max
5 to 24 VDC
EO Pulse train output LAD frequency 10 VDC 2 mA
32 kHz max
Analog input
signal
HFrequency reference power supply 10 VDC 10 mA max
OVoltage frequency reference signal 0 to 10 VDC (10 k)
OI Current frequency reference signal 4 to 20 mA (250 )
LFrequency reference common (bottom row) --
Digital output
signals
11/EDM Discrete logic output 1 / EDM output Factory setting: During Run
27 VDC, 50 mA max
EDM based on
ISO13849-1
12 Discrete logic output 2 Factory setting: Frequency arrival type 1
CM2 GND logic output --
AL0 Relay common contact Factory setting: Alarm signal
Under normal operation
AL1 - AL0 Closed
AL2 - AL0 Open
R load
250 VAC 2.5 A
30 VDC 3.0 A
I load
250 VAC 0.2 A
30 VDC 0.7 A
AL1 Relay contact, normally open
AL2 Relay contact, normally closed
Monitor
Signal
AM Analog voltage output Factory setting: LAD frequency 0 to 10 VDC 1 mA
Comms
SP
Serial communication terminal RS485 Modbus communication
SN
Model 3G3MX2 AB001 AB002 AB004 AB007 AB015 AB022
Inverter
capacity
kVA
200V VT 0.4 0.6 1.2 2.0 3.3 4.1
200V CT 0.2 0.5 1.0 1.7 2.7 3.8
240V VT 0.4 0.7 1.4 2.4 3.9 4.9
240V CT 0.3 0.6 1.2 2.0 3.3 4.5
Rated current (A) VT 1.2 1.9 3.4 6.0 9.6 12.0
Rated current (A) CT 1.0 1.6 3.0 5.0 8.0 11.0
Total heat loss 12 22 30 48 79 104
Efficiency at rated load 89.5 90 93 94 95 95.5
Cooling Method Self cooling Forced-air-cooling
Enclosure 100mm
100mm
50mm
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 18 Dienstag, 4. November 2014 12:02 12
MX2 19
Three-phase 200 V class
Three-phase 400 V class
Input AC Reactor
DC Reactor
Output AC Reactor
Model 3G3MX2 A2001 A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150
Inverter
capacity
kVA
200 VT 0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
200 CT 0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
240 VT 0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
240 CT 0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
Rated current (A) VT 1.2 1.9 3.4 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Rated current (A) CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
Total heat loss 12 22 30 48 79 104 154 229 313 458 625
Efficiency at rated load 89.5 90 93 94 95 95.5 96 96 96 96 96
Cooling Method Self cooling Forced-air-cooling
Model 3G3MX2 A4004 A4007 A4015 A4022 A4030 A4040 A4055 A4075 A4110 A4150
Inverter
capacity
kVA
380V VT 1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
380V CT 1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
480V VT 1.7 3.4 4.4 5.7 7.3 9.2 14.5 19.1 25.7 31.5
480V CT 1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
Rated current (A) VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
Rated current (A) CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
Total heat loss 35 56 96 116 125 167 229 296 411 528
Efficiency at rated load 92 93 94 95 96 96 96 96.2 96.4 96.6
Cooling Method Self cooling Forced-air-cooling
1 phase 200 V class 3 phase 200 V class 400 V class
Max. ap-
plicable
motor
output kW
Reference
Current
value
A
Induc-
tance
mH
Max. ap-
plicable
motor
output kW
Reference
Current
value
A
Induc-
tance
mH
Max. ap-
plicable
motor out-
put kW
Reference
Current
value
A
Induc-
tance
mH
0.4 AX-RAI02000070-DE 7.0 2.0 1.5 AX-RAI02800080-DE 8.0 2.8 1.5 AX-RAI07700050-DE 5.0 7.7
0.75 AX-RAI01700140-DE 14.0 1.7 3.7 AX-RAI00880200-DE 20.0 0.88 4.0 AX-RAI03500100-DE 10.0 3.5
1.5 AX-RAI01200200-DE 20.0 1.2 7.5 AX-RAI00350335-DE 33.5 0.35 7.5 AX-RAI01300170-DE 17.0 1.3
2.2 AX-RAI00630240-DE 24.0 0.63 15 AX-RAI00180670-DE 67.0 0.18 15 AX-RAI00740335-DE 33.5 0.74
200 V class 400 V class
Max. applicable
motor output kW Reference Current value
A
Inductance
mH
Max. applicable
motor output kW Reference Current value
A
Inductance
mH
0.2 AX-RC21400016-DE 1.6 21.4 0.4 AX-RC43000020-DE 2.0 43.0
0.4 AX-RC10700032-DE 3.2 10.7 0.7 AX-RC27000030-DE 3.0 27.0
0.7 AX-RC06750061-DE 6.1 6.75 1.5 AX-RC14000047-DE 4.7 14.0
1.5 AX-RC03510093-DE 9.3 3.51 2.2 AX-RC10100069-DE 6.9 10.1
2.2 AX-RC02510138-DE 13.8 2.51 3.0 AX-RC08250093-DE 9.3 8.25
3.7 AX-RC01600223-DE 22.3 1.60 4.0 AX-RC06400116-DE 11.6 6.40
5.5 AX-RC01110309-DE 30.9 1.11 5.5 AX-RC04410167-DE 16.7 4.41
7.5 AX-RC00840437-DE 43.7 0.84 7.5 AX-RC03350219-DE 21.9 3.35
11.0 AX-RC00590614-DE 61.4 0.59 11.0 AX-RC02330307-DE 30.7 2.33
15.0 AX-RC00440859-DE 85.9 0.44 15.0 AX-RC01750430-DE 43.0 1.75
200 V class 400 V class
Max. applicable
motor output kW Reference Current value
A
Inductance
mH
Max. applicable
motor output kW Reference Current value
A
Inductance
mH
0.4 AX-RAO11500026-DE 2.6 11.50
1.5 AX-RAO16300038-DE 3.8 16.30
0.75 AX-RAO07600042-DE 4.2 7.60
1.5 AX-RAO04100075-DE 7.5 4.10
2.2 AX-RAO03000105-DE 10.5 3.00 2.2 AX-RAO11800053-DE 5.3 11.80
3.7 AX-RAO01830160-DE 16.0 1.83 4.0 AX-RAO07300080-DE 8.0 7.30
5.5 AX-RAO01150220-DE 22.0 1.15 5.5 AX-RAO04600110-DE 11.0 4.60
7.5 AX-RAO00950320-DE 32.0 0.95 7.5 AX-RAO03600160-DE 16.0 3.60
11 AX-RAO00630430-DE 43.0 0.63 11 AX-RAO02500220-DE 22.0 2.50
15 AX-RAO00490640-DE 64.0 0.49 15 AX-RAO02000320-DE 32.0 2.00
MCCB
Power supply
AC reactor MX2
R/L1U
V
W
X
Y
Z
S/L2
T/L3
Power
supply
MX2
DC reactor
R/L1
+1 P/+2
MCCB
S/L2
T/L3
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 19 Dienstag, 4. November 2014 12:02 12
20 Frequency inverters
3G3MX2
Ordering information
Specifications Model
Voltage class Constant torque Variable torque Standard (IP20) Finless IP54
Max motor kW Rated current A Max motor kW Rated current A
Single-phase
200 V
0.1 1.0 0.2 1.2 3G3MX2-AB001-E 3G3MX2-AB001-P-E 3G3MX2-DB001-E/EC
0.2 1.6 0.4 1.9 3G3MX2-AB002-E 3G3MX2-AB002-P-E 3G3MX2-DB002-E/EC
0.4 3.0 0.55 3.5 3G3MX2-AB004-E 3G3MX2-AB004-P-E 3G3MX2-DB004-E/EC
0.75 5.0 1.1 6.0 3G3MX2-AB007-E 3G3MX2-AB007-P-E 3G3MX2-DB007-EC
1.5 8.0 2.2 9.6 3G3MX2-AB015-E 3G3MX2-AB015-P-E 3G3MX2-DB015-EC
2.2 11.0 3.0 12.0 3G3MX2-AB022-E 3G3MX2-AB022-P-E 3G3MX2-DB022-EC
Three-phase
200 V
0.1 1.0 0.2 1.2 3G3MX2-A2001-E 3G3MX2-A2001-P-E 3G3MX2-D2001-E/EC
0.2 1.6 0.4 1.9 3G3MX2-A2002-E 3G3MX2-A2002-P-E 3G3MX2-D2002-E/EC
0.4 3.0 0.55 3.5 3G3MX2-A2004-E 3G3MX2-A2004-P-E 3G3MX2-D2004-E/EC
0.75 5.0 1.1 6.0 3G3MX2-A2007-E 3G3MX2-A2007-P-E 3G3MX2-D2007-E/EC
1.5 8.0 2.2 9.6 3G3MX2-A2015-E 3G3MX2-A2015-P-E 3G3MX2-D2015-EC
2.2 11.0 3.0 12.0 3G3MX2-A2022-E 3G3MX2-A2022-P-E 3G3MX2-D2022-EC
3.7 17.5 5.5 19.6 3G3MX2-A2037-E 3G3MX2-A2037-P-E 3G3MX2-D2037-EC
5.5 25.0 7.5 30.0 3G3MX2-A2055-E - 3G3MX2-D2055-EC
7.5 33.0 11 40.0 3G3MX2-A2075-E - 3G3MX2-D2075-EC
11 47.0 15 56.0 3G3MX2-A2110-E - 3G3MX2-D2110-EC
15 60.0 18.5 69.0 3G3MX2-A2150-E - 3G3MX2-D2150-EC
Three-phase
400 V
0.4 1.8 0.75 2.1 3G3MX2-A4004-E 3G3MX2-A4004-P-E 3G3MX2-D4004-EC
0.75 3.4 1.5 4.1 3G3MX2-A4007-E 3G3MX2-A4007-P-E 3G3MX2-D4007-EC
1.5 4.8 2.2 5.4 3G3MX2-A4015-E 3G3MX2-A4015-P-E 3G3MX2-D4015-EC
2.2 5.5 3.0 6.9 3G3MX2-A4022-E 3G3MX2-A4022-P-E 3G3MX2-D4022-EC
3.0 7.2 4.0 8.8 3G3MX2-A4030-E 3G3MX2-A4030-P-E 3G3MX2-D4030-EC
4.0 9.2 5.5 11.1 3G3MX2-A4040-E 3G3MX2-A4040-P-E 3G3MX2-D4040-EC
5.5 14.8 7.5 17.5 3G3MX2-A4055-E - 3G3MX2-D4055-EC
7.5 18.0 11 23.0 3G3MX2-A4075-E - 3G3MX2-D4075-EC
11 24.0 15 31.0 3G3MX2-A4110-E - 3G3MX2-D4110-EC
15 31.0 18.5 38.0 3G3MX2-A4150-E - 3G3MX2-D4150-EC
A
BB
A
A
C
A
D
B
B
E
A
Choke
LCD 5 lines remote
operator
Remote operator
extension cable
Output AC reactor
Communication option
USB cable
Braking resistor
CX-Drive
CX-One
Installation accessory
MCCB
MX2
Filter
Input AC reactor
Motor
Ground
Power
supply
DC reactor
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 20 Dienstag, 4. November 2014 12:02 12
20 Frequency inverters
3G3MX2
Ordering information
Specifications Model
Voltage class Constant torque Variable torque Standard (IP20) Finless IP54
Max motor kW Rated current A Max motor kW Rated current A
Single-phase
200 V
0.1 1.0 0.2 1.2 3G3MX2-AB001-E 3G3MX2-AB001-P-E 3G3MX2-DB001-E/EC
0.2 1.6 0.4 1.9 3G3MX2-AB002-E 3G3MX2-AB002-P-E 3G3MX2-DB002-E/EC
0.4 3.0 0.55 3.5 3G3MX2-AB004-E 3G3MX2-AB004-P-E 3G3MX2-DB004-E/EC
0.75 5.0 1.1 6.0 3G3MX2-AB007-E 3G3MX2-AB007-P-E 3G3MX2-DB007-EC
1.5 8.0 2.2 9.6 3G3MX2-AB015-E 3G3MX2-AB015-P-E 3G3MX2-DB015-EC
2.2 11.0 3.0 12.0 3G3MX2-AB022-E 3G3MX2-AB022-P-E 3G3MX2-DB022-EC
Three-phase
200 V
0.1 1.0 0.2 1.2 3G3MX2-A2001-E 3G3MX2-A2001-P-E 3G3MX2-D2001-E/EC
0.2 1.6 0.4 1.9 3G3MX2-A2002-E 3G3MX2-A2002-P-E 3G3MX2-D2002-E/EC
0.4 3.0 0.55 3.5 3G3MX2-A2004-E 3G3MX2-A2004-P-E 3G3MX2-D2004-E/EC
0.75 5.0 1.1 6.0 3G3MX2-A2007-E 3G3MX2-A2007-P-E 3G3MX2-D2007-E/EC
1.5 8.0 2.2 9.6 3G3MX2-A2015-E 3G3MX2-A2015-P-E 3G3MX2-D2015-EC
2.2 11.0 3.0 12.0 3G3MX2-A2022-E 3G3MX2-A2022-P-E 3G3MX2-D2022-EC
3.7 17.5 5.5 19.6 3G3MX2-A2037-E 3G3MX2-A2037-P-E 3G3MX2-D2037-EC
5.5 25.0 7.5 30.0 3G3MX2-A2055-E - 3G3MX2-D2055-EC
7.5 33.0 11 40.0 3G3MX2-A2075-E - 3G3MX2-D2075-EC
11 47.0 15 56.0 3G3MX2-A2110-E - 3G3MX2-D2110-EC
15 60.0 18.5 69.0 3G3MX2-A2150-E - 3G3MX2-D2150-EC
Three-phase
400 V
0.4 1.8 0.75 2.1 3G3MX2-A4004-E 3G3MX2-A4004-P-E 3G3MX2-D4004-EC
0.75 3.4 1.5 4.1 3G3MX2-A4007-E 3G3MX2-A4007-P-E 3G3MX2-D4007-EC
1.5 4.8 2.2 5.4 3G3MX2-A4015-E 3G3MX2-A4015-P-E 3G3MX2-D4015-EC
2.2 5.5 3.0 6.9 3G3MX2-A4022-E 3G3MX2-A4022-P-E 3G3MX2-D4022-EC
3.0 7.2 4.0 8.8 3G3MX2-A4030-E 3G3MX2-A4030-P-E 3G3MX2-D4030-EC
4.0 9.2 5.5 11.1 3G3MX2-A4040-E 3G3MX2-A4040-P-E 3G3MX2-D4040-EC
5.5 14.8 7.5 17.5 3G3MX2-A4055-E - 3G3MX2-D4055-EC
7.5 18.0 11 23.0 3G3MX2-A4075-E - 3G3MX2-D4075-EC
11 24.0 15 31.0 3G3MX2-A4110-E - 3G3MX2-D4110-EC
15 31.0 18.5 38.0 3G3MX2-A4150-E - 3G3MX2-D4150-EC
A
BB
A
A
C
A
D
B
B
E
A
Choke
LCD 5 lines remote
operator
Remote operator
extension cable
Output AC reactor
Communication option
USB cable
Braking resistor
CX-Drive
CX-One
Installation accessory
MCCB
MX2
Filter
Input AC reactor
Motor
Ground
Power
supply
DC reactor
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 20 Dienstag, 4. November 2014 12:02 12
MX2 21
A Line filters
A Input AC reactors
A DC reactors
Inverter Standard line filter Low leakage line filter
Rasmi Schaffner Rasmi Schaffner
Voltage Model 3G3MX2-@Reference
AX-FIM Current (A) Reference
AX-FIM Current (A) Reference
AX-FIM Current (A) Reference
AX-FIM Current (A)
1Phase
200 VAC
AB001 / AB002 /
AB004 1010-RE 10 1010-SE-V1 8 1010-RE-LL 10 1010-SE-LL 10
AB007 1014-RE 14 1014-SE-V1 14 1014-RE-LL 14 1014-SE-LL 14
AB015 / AB022 1024-RE 24 1024-SE-V1 27 1024-RE-LL 24 1024-SE-LL 24
3Phase
200 VAC
A2001 / A2002 /
A2004 / A2007 2010-RE 10 2010-SE-V1 7.8 2010-RE-LL 10 --
A2015 / A2022 2020-RE 20 2020-SE-V1 16 2020-RE-LL 20 2020-SE-LL 20
A2037 2030-RE 30 2030-SE-V1 25 2030-RE-LL 30 2030-SE-LL 30
A2055 / A2075 2060-RE 60 2060-SE-V1 50 2060-RE-LL 60 2060-SE-LL 50
A2110 2080-RE 80 2080-SE-V1 70 2080-RE-LL 80 --
A2150 2100-RE 100 2100-SE-V1 75 2100-RE-LL 100 --
3Phase
400 VAC
A4004 / A4007 3005-RE 5 3005-SE-V1 6 3005-RE-LL 5 3005-SE-LL 5
A4015 / A4022 /
A4030 3010-RE 10 3010-SE-V1 12 3010-RE-LL 10 3010-SE-LL 10
A4040 3014-RE 14 3014-SE-V1 15 3014-RE-LL 14 3014-SE-LL 15
A4055 / A4075 3030-RE 30 3030-SE-V1 29 3030-RE-LL 30 3030-SE-LL 30
A4110 / A4150 3050-RE 50 3050-SE-V1 48 3050-RE-LL 50 3050-SE-LL 50
Inverter AC Reactor
Voltage Model 3G3MX2-@Reference
1-Phase 200 VAC
AB002 / AB004 AX-RAI02000070-DE
AB007 AX-RAI01700140-DE
AB015 AX-RAI01200200-DE
AB022 AX-RAI00630240-DE
3-Phase 200 VAC
A2002 / A2004 / A2007 AX-RAI02800080-DE
A2015 / A2022 / A2037 AX-RAI00880200-DE
A2055 / A2075 AX-RAI00350335-DE
A2110 / A2150 AX-RAI00180670-DE
3-Phase 400 VAC
A4004 / A4007 / A4015 AX-RAI07700050-DE
A4022 / A4030 / A4040 AX-RAI03500100-DE
A4055 / A4075 AX-RAI01300170-DE
A4110 / A4150 AX-RAI00740335-DE
200V 1-phase 200V 3-phase 400V 3-phase
Inverter DC Reactor Inverter DC Reactor Inverter DC Reactor
3G3MX2-AB001 AX-RC10700032-DE 3G3MX2-A2001 AX-RC21400016-DE 3G3MX2-A4004 AX-RC43000020-DE
3G3MX2-AB002 3G3MX2-A2002 3G3MX2-A4007 AX-RC27000030-DE
3G3MX2-AB004 AX-RC06750061-DE 3G3MX2-A2004 AX-RC10700032-DE 3G3MX2-A4015 AX-RC14000047-DE
3G3MX2-AB007 AX-RC03510093-DE 3G3MX2-A2007 AX-RC06750061-DE 3G3MX2-A4022 AX-RC10100069-DE
3G3MX2-AB015 AX-RC02510138-DE 3G3MX2-A2015 AX-RC03510093-DE 3G3MX2-A4030 AX-RC08250093-DE
3G3MX2-AB022 AX-RC01600223-DE 3G3MX2-A2022 AX-RC02510138-DE 3G3MX2-A4040 AX-RC06400116-DE
-
3G3MX2-A2037 AX-RC01600223-DE 3G3MX2-A4055 AX-RC04410167-DE
3G3MX2-A2055 AX-RC01110309-DE 3G3MX2-A4075 AX-RC03350219-DE
3G3MX2-A2075 AX-RC00840437-DE 3G3MX2-A4011 AX-RC02330307-DE
3G3MX2-A2011 AX-RC00590614-DE 3G3MX2-A4015 AX-RC01750430-DE
3G3MX2-A2015 AX-RC00440859-DE -
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 21 Dienstag, 4. November 2014 12:02 12
22 Frequency inverters
A Chokes A Output AC reactor
B Accessories
C Communication option boards
Model Diameter Description
AX-FER2102-RE 21 For 2.2 KW motors or below
AX-FER2515-RE 25 For 15 KW motors or below
AX-FER5045-RE 50 For 45 KW motors or below
Inverter AC Reactor
Voltage Model 3G3MX2-@Reference
200 VAC
AB001 / AB002 / AB004
A2001 / A2002 / A2004 AX-RAO11500026-DE
AB007 / A2007 AX-RAO07600042-DE
AB015 / A2015 AX-RAO04100075-DE
AB022 / A2022 AX-RAO03000105-DE
A2037 AX-RAO01830160-DE
A2055 AX-RAO01150220-DE
A2075 AX-RAO00950320-DE
A2110 AX-RAO00630430-DE
A2150 AX-RAO00490640-DE
400 VAC
A4004 / A4007 / A4015 AX-RAO16300038-DE
A4022 AX-RAO11800053-DE
A4030 / A4040 AX-RAO07300080-DE
A4055 AX-RAO04600110-DE
A4075 AX-RAO03600160-DE
A4110 AX-RAO02500220-DE
A4150 AX-RAO02000320-DE
Types Model Description Functions
Digital
operator
AX-OP05-E LCD remote operator 5 Line LCD remote operator with copy function, cable length max. 3m.
3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator
3G3AX-OP01 LED remote operator LED remote operator, cable length max. 3m
4X-KITMINI Mounting kit for LED operator Mounting kit for LED operator on panel
3G3AX-OP05-H-E Operator holder Holder to put the AX-OP05-E inside of the cabinet
Accessories
AX-CUSBM002-E PC configuration cable Mini USB to USB connector cable
Types Model Description Functions
Communication options
3G3AX-MX2-PRT Profibus option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through communications with the host con-
troller.
3G3AX-MX2-DRT DeviceNet option card
3G3AX-MX2-ECT EtherCAT option card
3G3AX-MX2-CRT CompoNet option card
3G3AX-MX2-MRT MECHATROLINK-II option card
3G3AX-MX2-EIP EtherNet/IP option card
I/O option
3G3AX-MX2-EIO15-E Extra input/output option board 1 analog voltage input, 1 analog current input, 1 analog voltage output, 8 discrete logic inputs,
4 discrete logic outputs
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 22 Dienstag, 4. November 2014 12:02 12
22 Frequency inverters
A Chokes A Output AC reactor
B Accessories
C Communication option boards
Model Diameter Description
AX-FER2102-RE 21 For 2.2 KW motors or below
AX-FER2515-RE 25 For 15 KW motors or below
AX-FER5045-RE 50 For 45 KW motors or below
Inverter AC Reactor
Voltage Model 3G3MX2-@Reference
200 VAC
AB001 / AB002 / AB004
A2001 / A2002 / A2004 AX-RAO11500026-DE
AB007 / A2007 AX-RAO07600042-DE
AB015 / A2015 AX-RAO04100075-DE
AB022 / A2022 AX-RAO03000105-DE
A2037 AX-RAO01830160-DE
A2055 AX-RAO01150220-DE
A2075 AX-RAO00950320-DE
A2110 AX-RAO00630430-DE
A2150 AX-RAO00490640-DE
400 VAC
A4004 / A4007 / A4015 AX-RAO16300038-DE
A4022 AX-RAO11800053-DE
A4030 / A4040 AX-RAO07300080-DE
A4055 AX-RAO04600110-DE
A4075 AX-RAO03600160-DE
A4110 AX-RAO02500220-DE
A4150 AX-RAO02000320-DE
Types Model Description Functions
Digital
operator
AX-OP05-E LCD remote operator 5 Line LCD remote operator with copy function, cable length max. 3m.
3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator
3G3AX-OP01 LED remote operator LED remote operator, cable length max. 3m
4X-KITMINI Mounting kit for LED operator Mounting kit for LED operator on panel
3G3AX-OP05-H-E Operator holder Holder to put the AX-OP05-E inside of the cabinet
Accessories
AX-CUSBM002-E PC configuration cable Mini USB to USB connector cable
Types Model Description Functions
Communication options
3G3AX-MX2-PRT Profibus option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through communications with the host con-
troller.
3G3AX-MX2-DRT DeviceNet option card
3G3AX-MX2-ECT EtherCAT option card
3G3AX-MX2-CRT CompoNet option card
3G3AX-MX2-MRT MECHATROLINK-II option card
3G3AX-MX2-EIP EtherNet/IP option card
I/O option
3G3AX-MX2-EIO15-E Extra input/output option board 1 analog voltage input, 1 analog current input, 1 analog voltage output, 8 discrete logic inputs,
4 discrete logic outputs
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 22 Dienstag, 4. November 2014 12:02 12
MX2 23
D Braking unit, braking resistor unit
E Computer software
Inverter Braking resistor unit
Voltage
Max.
motor
kW
Inverter 3G3MX2@Connectable
min.
resistance
Inverter mounted type
(3 %ED, 10 sec max) Braking
torque %
Inverter mounted type
(10%ED, 10 sec max) Braking
torque %
1-phase 3-phase Type AX- Resist Type AX- Resist
200 V
(Single-/
Three-
phase)
0.12 B001 2001
100 REM00K1400-IE 400 200 REM00K1400-IE 400 200
0.25 B002 2002 180 180
0.55 B004 2004 REM00K1200-IE 200 180 REM00K1200-IE 200 180
1.1 B007 2007 50 100 REM00K2070-IE 70 200
1.5 B015 2015 REM00K2070-IE 70 140 REM00K4075-IE 75 130
2.2 B022 2022 35 90 REM00K4035-IE 35 180
4.0 2040 REM00K4075-IE 75 50 REM00K6035-IE 35 100
5.5 2055 20 REM00K4035-IE 35 75 REM00K9020-IE 20 150
7.5 2075 17 55 REM01K9017-IE 17 110
11 2110 REM00K6035-IE 35 40 REM02K1017-IE 17 75
15 2150 10 REM00K9017-IE 17 55 REM03K5010-IE 10 95
400 V
(Three-
phase)
0.55 4004
180 REM00K1400-IE 400 200 REM00K1400-IE 400 200
1.1 4007 200 200
1.5 4015 REM00K1200-IE 200 190 REM00K2200-IE 200 190
2.2 4022
100
REM00K2200-IE 200 130 REM00K5120-IE 120 200
3.0 4030 REM00K2120-IE 120 160 160
4.0 4040 120 REM00K6100-IE 100 140
5.5 4055
70 REM00K4075-IE 75 140 REM00K9070-IE 70 150
7.5 4075 100 REM01K9070-IE 70 110
11 4110 REM00K6100-IE 100 50 REM02K1070-IE 70 75
15 4150 35 REM00K9070-IE 70 55 REM03K5035-IE 35 110
Types Model Description Installation
Software
CX-Drive Computer software Configuration and monitoring software tool
CX-One Computer software Configuration and monitoring software tool
€Saver Computer software Software tool for Energy Saving calculation
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I113E-EN-05
I113E-EN-05+MX2+Datasheet_KPP.fm Seite 23 Dienstag, 4. November 2014 12:02 12
Sales & Support Offices
Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant
or make any representations regarding the correctness or completeness of the information described in this document.
We reserve the right to make any changes at any time without prior notice.
KPP_MX2_EN_INT05
Would you like to know more?
OMRON EUROPE
+31 (0) 23 568 13 00
industrial.omron.eu
omron.me/socialmedia_eu
Austria
Tel: +43 (0) 2236 377 800
industrial.omron.at
Belgium
Tel: +32 (0) 2 466 24 80
industrial.omron.be
Czech Republic
Tel: +420 234 602 602
industrial.omron.cz
Denmark
Tel: +45 43 44 00 11
industrial.omron.dk
Finland
Tel: +358 (0) 207 464 200
industrial.omron.fi
France
Tel: +33 (0) 1 56 63 70 00
industrial.omron.fr
Germany
Tel: +49 (0) 2173 680 00
industrial.omron.de
Hungary
Tel: +36 1 399 30 50
industrial.omron.hu
Italy
Tel: +39 02 326 81
industrial.omron.it
Netherlands
Tel: +31 (0) 23 568 11 00
industrial.omron.nl
Norway
Tel: +47 (0) 22 65 75 00
industrial.omron.no
Poland
Tel: +48 22 458 66 66
industrial.omron.pl
Portugal
Tel: +351 21 942 94 00
industrial.omron.pt
Russia
Tel: +7 495 648 94 50
industrial.omron.ru
South Africa
Tel: +27 (0)11 579 2600
industrial.omron.co.za
Spain
Tel: +34 902 100 221
industrial.omron.es
Sweden
Tel: +46 (0) 8 632 35 00
industrial.omron.se
Switzerland
Tel: +41 (0) 41 748 13 13
industrial.omron.ch
Turkey
Tel: +90 212 467 30 00
industrial.omron.com.tr
United Kingdom
Tel: +44 (0) 1908 258 258
industrial.omron.co.uk
More Omron representatives
industrial.omron.eu
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
3G3AX-REM00K4035-IE 3G3AX-REM02K1017-IE 3G3AX-REM00K2070-IE 3G3AX-MX2-PRT 3G3AX-
REM00K9070-IE 3G3AX-REM00K6035-IE 3G3AX-REM03K5035-IE 3G3AX-REM03K5010-IE 3G3AX-MX2-ML2
3G3AX-REM00K5120-IE 3G3AX-REM00K4075-IE 3G3AX-REM01K9017-IE 3G3AX-MX2-CRT 3G3AX-REM01K9070-
IE 3G3AX-REM00K9020-IE 3G3AX-OP05 3G3AX-REM00K2200-IE 3G3AX-REM00K6100-IE 3G3AX-REM00K1400-
IE 3G3AX-MX2-DRT 3G3AX-REM00K9017-IE 3G3AX-REM02K1070-IE 3G3AX-REM00K2120-IE