1071-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZWQ Series
Features
Universal Input (85 - 265VAC)
Power Factor Corrected
Floating Adjustable Fourth Output
Low Pro le <1U High
80W to 170W Quad Output Power Supplies
(1) 100/200VAC
(2) Avoid prolong operation in overload
(3) /A version - additional derating, see installation manual
ZWQ80 ZWQ80 ZWQ80 ZWQ80 ZWQ130 ZWQ130 ZWQ130 ZWQ130
Model -5222 -5223 -5224 -5225 -5222 -5223 -5224 -5225
Input Voltage - 85-265VAC (47-63Hz), 120-370VDC*
Input Current (1) A 1.6 / 0.8 2.6 / 1.3
Inrush Current (1) A 14/28
Power Factor - Meets EN61000-3-2
Temperature Coef cient - <0.02%/°C
Max Output Power (convection) W 80 130
Max Output Power (forced air) W 104 88.7 104 104 170 149.6 170 170
Overpower Protection (2) W >109 >93 >109 >109 >173 >152 >173 >173
Minimum Load A V1: 0.9A Conv, 1.4A Forced Air V1: 1.5A Conv, 2.1A Forced Air
Output Voltage Accuracy % ±5% for outputs V2 and V3
Ef ciency (Typ) % 72
Hold Up Time (1) ms 20
Leakage Current - 0.75mA max, 0.2mA (Typ) at 100VAC / 0.44mA(Typ) at 230VAC
Remote On / Off - See installation manual (Not available with /A cover option)
Oper Temp (convection cooled) °C -10°C to 60°C, derate linearly to 50% load from 40°C to 60°C. (3)
Oper Temp (forced air cooled) °C -10°C to 70°C, derate linearly to 50% load from 50°C to 70°C. (>30cfm air ow)(3)
Storage Temperature °C -30° to +85°C
Humidity (non condensing) - Operating: 30 - 90% RH; Non-operating 10-95% RH
Withstand Voltage - I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
Isolation Resistance - >100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock - < 196.1 m/s2
Safety Agency Approvals - UL60950-1, CSA60950-1, EN60950-1, CE Mark, EN50178
Conducted & Radiated EMI - EN55011, EN55022-B, FCC Class B, VCCI-B
Immunity - EN61000-4-2,-3,-4,-5,-6,-8,-11
Weight (Typ) g 550 730
Size (W x H x D) mm 93.5 x 35 x 210 (refer to outline drawing) 106 x 35 x 225 (refer to outline drawing)
Warranty yrs One Year
Speci cations
Key Market Segments & Applications
*Safety certi ed for AC input only
1081-800-526-2324 • www.us.tdk-lambda.com/lp/ Revision A4.1: Apr 2014
ZWQ Series
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zwq-series.htm
(4) The peak current draw must not exceed a 10 sec. duration with a
duty cycle of 35%.
(5) An overvoltage condition on any output will shut down all outputs,
the power supply must be re-set by cycling the AC input.
Voltage Peak or Max Max Ripple
Adjust Convect. Forced Air Load Reg Line Reg Noise OVP
Model Output Voltage (V) Range (V) (A) (A)(4) (mV) (mV) (mV) (V)(5)
ZWQ80-5222 V1 5 5.0-5.25 8.0 10.0 100 20 120 5.7-7.0
V2 +12/15* +12/+15 2.0 2.5 300 48 150 16.5-22.5
V3 -12/15* -12/-15 2.0 2.5 300 48 150 16.5-22.5
V4 12 11.4-12.6 3.0 4.0 300 48 150 13.8-16.2
ZWQ80-5223 V1 5 5.0-5.25 8.0 10.0 100 20 120 5.7-7.0
V2 +12/15* +12/+15 2.0 2.5 300 48 150 16.5-22.5
V3 -12/15* -12/-15 2.0 2.5 300 48 150 16.5-22.5
V4 3.3 2.0-3.63 7.0 9.0 100 20 120 3.79-4.95
ZWQ80-5224 V1 5 5.0-5.25 8.0 10.0 100 20 120 5.7-7.0
V2 +12/15* +12/+15 2.0 2.5 300 48 150 16.5-22.5
V3 -12/15* -12/-15 2.0 2.5 300 48 150 16.5-22.5
V4 24 22.8-25.2 1.5 2.0 400 96 200 27.6-32.4
ZWQ80-5225 V1 5 5.0-5.25 8.0 10.0 100 20 120 5.7-7.0
V2 +12/15* +12/+15 2.0 2.5 300 48 150 16.5-22.5
V3 -12/15* -12/-15 2.0 2.5 300 48 150 16.5-22.5
V4 5 2.0-5.25 7.0 9.0 100 20 120 5.7-7.0
ZWQ130-5222 V1 5 5.0-5.25 15.0 19.0 100 20 120 5.7-7.0
V2 +12/15* +12/+15 4.0 5.0 300 48 150 16.5-22.5
V3 -12/15* -12/-15 4.0 5.0 300 48 150 16.5-22.5
V4 12 11.4-12.6 4.0 5.0 300 48 150 11.4-12.6
ZWQ130-5223 V1 5 5.0-5.25 15.0 19.0 100 20 120 5.7-7.0
V2 +12/15* +12/+15 4.0 5.0 300 48 150 16.5-22.5
V3 -12/15* -12/-15 4.0 5.0 300 48 150 16.5-22.5
V4 3.3 2.0-3.63 10.0 12.0 100 20 120 3.79-4.95
ZWQ130-5224 V1 5 5.0-5.25 15.0 19.0 100 20 120 5.7-7.0
V2 +12/15* +12/+15 4.0 5.0 300 48 150 16.5-22.5
V3 -12/15* -12/-15 4.0 5.0 300 48 150 16.5-22.5
V4 24 22.8-25.2 2.0 2.5 400 96 200 27.6-32.4
ZWQ130-5225 V1 5 5.0-5.25 15.0 19.0 100 20 120 5.7-7.0
V2 +12/15* +12/+15 4.0 5.0 300 48 150 16.5-22.5
V3 -12/15* -12/-15 4.0 5.0 300 48 150 16.5-22.5
V4 5 2.0-5.25 10.0 12.0 100 20 120 5.7-7.0
* User selectable via connector or PCB. Outputs are oating from V1 & V4. Can be connected in series for 24/30V.
Model Selector
ZWS/ZWD 5W to 480W Single and dual output
SC 30W to 120W Single, dual, & triple output
NV 175 to 700W Single and multiple output
HWS 15 to 1500W Single output
Other Industrial Products
Suf x Description
blank No cover or L Bracket
/L L Bracket
/A Cover and L Bracket
Options
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TDK-Lambda:
ZWQ1305222/L ZWQ1305223/A ZWQ1305223/L ZWQ1305224 ZWQ1305224/A ZWQ805222 ZWQ805222/L
ZWQ805223 ZWQ805223/L ZWQ805224 ZWQ805225/A ZWQ1305223 ZWQ805225/L