ZWQ Series 80W to 170W Quad Output Power Supplies Features Universal Input (85 - 265VAC) Power Factor Corrected Floating Adjustable Fourth Output Low Profile <1U High Key Market Segments & Applications Specifications Model Input Voltage Input Current (1) Inrush Current (1) Power Factor Temperature Coefficient Max Output Power (convection) Max Output Power (forced air) Overpower Protection (2) Minimum Load Output Voltage Accuracy Efficiency (Typ) Hold Up Time (1) Leakage Current Remote On / Off Oper Temp (convection cooled) Oper Temp (forced air cooled) Storage Temperature Humidity (non condensing) Withstand Voltage Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated EMI Immunity Weight (Typ) Size (W x H x D) Warranty ZWQ80 -5222 A A W W W A % % ms C C C g mm yrs ZWQ80 -5223 ZWQ80 ZWQ80 ZWQ130 ZWQ130 ZWQ130 ZWQ130 -5224 -5225 -5222 -5223 -5224 -5225 85-265VAC (47-63Hz), 120-370VDC* 1.6 / 0.8 2.6 / 1.3 14/28 Meets EN61000-3-2 <0.02%/C 80 130 104 88.7 104 104 170 149.6 170 170 >109 >93 >109 >109 >173 >152 >173 >173 V1: 0.9A Conv, 1.4A Forced Air V1: 1.5A Conv, 2.1A Forced Air 5% for outputs V2 and V3 72 20 0.75mA max, 0.2mA (Typ) at 100VAC / 0.44mA(Typ) at 230VAC See installation manual (Not available with /A cover option) -10C to 60C, derate linearly to 50% load from 40C to 60C. (3) -10C to 70C, derate linearly to 50% load from 50C to 70C. (>30cfm airflow)(3) -30 to +85C Operating: 30 - 90% RH; Non-operating 10-95% RH I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min. >100M at 25C & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 UL60950-1, CSA60950-1, EN60950-1, CE Mark, EN50178 EN55011, EN55022-B, FCC Class B, VCCI-B EN61000-4-2,-3,-4,-5,-6,-8,-11 550 730 93.5 x 35 x 210 (refer to outline drawing) 106 x 35 x 225 (refer to outline drawing) One Year (1) 100/200VAC (2) Avoid prolong operation in overload (3) /A version - additional derating, see installation manual 1-800-526-2324 * www.us.tdk-lambda.com/lp/ *Safety certified for AC input only 107 Disclaimer: us.tdk-lambda.com/lp/legal.htm ZWQ Series Model Selector Voltage Peak or Max Max Ripple Adjust Convect. Forced Air Load Reg Line Reg Noise Model Output Voltage (V) Range (V) (A) (A)(4) (mV) (mV) (mV) ZWQ80-5222 V1 5 5.0-5.25 8.0 10.0 100 20 120 V2 +12/15* +12/+15 2.0 2.5 300 48 150 V3 -12/15* -12/-15 2.0 2.5 300 48 150 V4 12 11.4-12.6 3.0 4.0 300 48 150 ZWQ80-5223 V1 5 5.0-5.25 8.0 10.0 100 20 120 V2 +12/15* +12/+15 2.0 2.5 300 48 150 V3 -12/15* -12/-15 2.0 2.5 300 48 150 V4 3.3 2.0-3.63 7.0 9.0 100 20 120 ZWQ80-5224 V1 5 5.0-5.25 8.0 10.0 100 20 120 V2 +12/15* +12/+15 2.0 2.5 300 48 150 V3 -12/15* -12/-15 2.0 2.5 300 48 150 V4 24 22.8-25.2 1.5 2.0 400 96 200 ZWQ80-5225 V1 5 5.0-5.25 8.0 10.0 100 20 120 V2 +12/15* +12/+15 2.0 2.5 300 48 150 V3 -12/15* -12/-15 2.0 2.5 300 48 150 V4 5 2.0-5.25 7.0 9.0 100 20 120 ZWQ130-5222 V1 5 5.0-5.25 15.0 19.0 100 20 120 V2 +12/15* +12/+15 4.0 5.0 300 48 150 V3 -12/15* -12/-15 4.0 5.0 300 48 150 V4 12 11.4-12.6 4.0 5.0 300 48 150 ZWQ130-5223 V1 5 5.0-5.25 15.0 19.0 100 20 120 V2 +12/15* +12/+15 4.0 5.0 300 48 150 V3 -12/15* -12/-15 4.0 5.0 300 48 150 V4 3.3 2.0-3.63 10.0 12.0 100 20 120 ZWQ130-5224 V1 5 5.0-5.25 15.0 19.0 100 20 120 V2 +12/15* +12/+15 4.0 5.0 300 48 150 V3 -12/15* -12/-15 4.0 5.0 300 48 150 V4 24 22.8-25.2 2.0 2.5 400 96 200 ZWQ130-5225 V1 5 5.0-5.25 15.0 19.0 100 20 120 V2 +12/15* +12/+15 4.0 5.0 300 48 150 V3 -12/15* -12/-15 4.0 5.0 300 48 150 V4 5 2.0-5.25 10.0 12.0 100 20 120 * User selectable via connector or PCB. Outputs are floating from V1 & V4. Can be connected in series for 24/30V. Other Industrial Products Options ZWS/ZWD SC NV HWS Suffix Description blank /L /A No cover or L Bracket L Bracket Cover and L Bracket 5W to 480W Single and dual output 30W to 120W Single, dual, & triple output 175 to 700W Single and multiple output 15 to 1500W Single output (4) The peak current draw must not exceed a 10 sec. duration with a duty cycle of 35%. (5) An overvoltage condition on any output will shut down all outputs, the power supply must be re-set by cycling the AC input. 1-800-526-2324 * www.us.tdk-lambda.com/lp/ OVP (V)(5) 5.7-7.0 16.5-22.5 16.5-22.5 13.8-16.2 5.7-7.0 16.5-22.5 16.5-22.5 3.79-4.95 5.7-7.0 16.5-22.5 16.5-22.5 27.6-32.4 5.7-7.0 16.5-22.5 16.5-22.5 5.7-7.0 5.7-7.0 16.5-22.5 16.5-22.5 11.4-12.6 5.7-7.0 16.5-22.5 16.5-22.5 3.79-4.95 5.7-7.0 16.5-22.5 16.5-22.5 27.6-32.4 5.7-7.0 16.5-22.5 16.5-22.5 5.7-7.0 For Additional Information, please visit us.tdk-lambda.com/lp/products/zwq-series.htm 108 Revision A4.1: Apr 2014 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: ZWQ1305222/L ZWQ1305223/A ZWQ1305223/L ZWQ1305224 ZWQ1305224/A ZWQ805222 ZWQ805222/L ZWQ805223 ZWQ805223/L ZWQ805224 ZWQ805225/A ZWQ1305223 ZWQ805225/L